HomeMy WebLinkAboutRES2003-01774PREPARED 9/23/03, 12:04:31 INSPECTION TICKET PAGE 12 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 9/23/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 1107 TYLER CT SUBDIV: ALEXANDRIA PH 5 CONTRACTOR : ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER : FROEHLING, EDWARD PHONE PARCEL : 106500-0505-0710 APPL NUMBER: 03-00001774 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------- PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 6/18/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00 6/18/03 AP 06/17/2003 02:36 PM KELMENDORF B11 01 8/25/03 CH 8/25/03 AP B130 01 8/27/03 CH B125 01 8/27/03 9/23 03 AP BI Lam-- A SLAB GROUND BACK LEFT SETBACK STRINGS PULLED BLDG, FRAMING TIME: 17:00 08/25/2003 07:59 AM SSTANLEY BLDG, INSULATION TIME: 17:00 08/26/2003 04:41 PM MALFORD BLDG, FINAL TIME: 17:00 09/23/2003 11:13 AM MALFORD - ---}L------------------------------ I v CONTINUED ONTO NEXT PAGE----------------------------------- 'ays.kUm 144 BUILDING PERMIT TAT STATION, COLLEGE ST , TX 778 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00001774 Date 6/04/03 Property Address . . . . . . 1107 TYLER CT Property ID . . 106500-0505-0710 R # . . . . . . . . . . . . . R114177 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . ALEXANDRIA PH 5 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . UNKNOWN Application valuation . . . . 132858 Owner Contractor ------------------------ FROEHLING, EDWARD ------------------------ ED FROEHLING BUILDERS 3887 HIGH LONESOME ED FROEHLING COLLEGE STATION TX 778459443 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL -MULTI -FAMILY Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1504.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 248.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 559.00 Plan Check Fee .00 Issue Date . . . . 6/04/03 Valuation . . . . 132858 Expiration Date . . 12/01/03 Qty Unit Charge Per Extension BASE FEE 460.00 33.00 3.0000 THOU BLDG, VAL 100001-500000 99.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER (S ) ---------------------------------------------------- - -- BUILDING DEP ,.,,REPRESENTATIVE: APPLICANT:1� Vjy� BUILDING PERMIT CITY OF COLLEGE STATIO" 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00001774 Date 6/04/03 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND 7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA) POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATI BUILDING DEP `n�P,(R�ESENTATIVE : APPLICANT: \�1\�1 BUILDING PERMIT CITY OF COLLEGE STATIO" 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00001774 Date 6/04/03 ---------------------------------------------------------------------------- Special Notes and Comments EQUIPMENT AND A PRESSURE REDUCING VALVE ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged ---------- Paid ---------- Credited -------------------- Due ----------------- Permit Fee Total 559.00 559.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1309.00 1309.00 .00 .00 ---------------------------------------------- n-�z ------------------- BUILDING DEPP\ PR,E`S\ENTATIVE : APPLICANT: 1NI �V CITY OF COLLEGE STATION WORv REQUEST PAGE 1 REQ/JOB: WF0414842 001 PROJECT: REQUEST DATE: 6/04/03 PRINT DATE: 6/04/03 CREW: PRINT TIME: 14:26:06 SCHSTAARR.T.DATES LOCATION: 1107 TYLER CT 6/04/03 77845 COMPLETION: 6/04703 GEN. LOC: COLLEGE STATION LOC ID: 196500 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: SS' ANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 4" SEWER 3/4" WATER 4" SEWER 2 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE Fa Office Use 0* A.. _ICATION FOR BUILDING PERT.... CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US 1-11 DATE: ,5 Z23110 3 APPLICATION # _0 ✓. (1.7+ TEMP POLE # ADDRESS/LOCATION: t 107 T YLE 4c_ c-©U fz7 LOT % `/ BLOCK SUBDIVISION A. I EY w f>et h- .S BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: f= fl Fe Dj5µL/.UG, S u ILpg PHONE: 774 • SZgG CONTRACTOR ADDRESS: 3$87 hl-lGN LoA/,= Sc�Nt� ?� 4dc..c-eGr- S?A-Ti2A Tk' 7784S ELECTRICIAN: Sf g P_-LEGTYi-/e— PLUMBER: "7A/PLE "S PLyn jRw4 HVAC: ZTO, IyP O YA-TiyE S�2✓tI.ES GOOD CENTS (Residential only):AJ A CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: STRUCTURE USE: S_1,,U4 G e FA m a y P-E-.. / DING iE HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (17AS PROJECT REGISTRATION# EABPR., VALUATION: $ 132, Cd6 TOTAL AREA; fT (Cost of Labor and Materials) 20 `2P ePUBLIC SEWER NUMBER OF BEDROOMS: F] SEPTIC/TREATMENT SYSTEM SEWER TAP: A SIZE ff"WATER TAP: SIZE OTHER TAP: TEMP POLE GARAGE TYPE: SIZE SINGLE a ATTACHED E5 SIGNATURE OF APPLICANT: Jro NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE FOUNDATION TYPE: ROOF TYPE: DOUBLE Eff DETACHED ED TRIPLE HEATED AREA: 3 15 d + —71- I��l LK SL A- 6 d.y GilL�l�-1� L�/9PbS�T/DAJ SfH�GiLE CARPORT El Official Use Only ents: YE/or NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls / , %/ Or Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) --3 Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating I. REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: Untitled.rck TITLE: 1107 TYLER COURT CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 05/23/03 DATE OF PLANS: JULY 31, 2002 PROJECT INFORMATION: BREWER HOME COMPANY INFORMATION: ED FROEHLING BUILDER, INC COMPLIANCE: Passes Maximum UA = 567 Your Home UA = 477 15.9% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.37 Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 135 deg. from North; Comp, orient.: Front Projection factor: 0.19 Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Left Side Projection factor: 0.43 Wall 3: Wood Frame, 16" o.c. Window 3: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Back Projection factor: 0.23 Wall 4: Wood Frame, 16" o.c. Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1504 30.0 0.0 53 394 13.0 0.0 27 0.640 29 0.400 8 3 13.0 0.0 28 5 0.640 10 410 13.0 0.0 4� 0.640 362 13.0 0.0 27 55 27 Igo 15P5 Window 4: Metal Frame:Double Pan( Low-E 0.640 8 SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Right Side Projection factor: 0.23 Door 2: Glass G 0.580 10 SHGC: 0.78 Bldg. faces 135 deg. from North; Comp. orient.: Right Side Projection factor: 0.81 Floor 1: Slab-On-Grade:Unheated 187 0.0 195 Insulation depth: 0.0' COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in RES checkVersion 3.5 Release lb (formerly MECchec4 and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer Date 5 C�3 r r xixigg 4 v n i L.S-P sod — -- — - - Q •- - -- - - - - - --- — -- - - �l C> � 1 At h �i {ri