HomeMy WebLinkAboutRES2003-01771PREPARED 4/06/04, 7:54:06 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/06/04
------------------------------------------------------------------------------------------------
ADDRESS . : 1109 COEBURN CT SUBDIV: ALEXANDRIA PH 5
CONTRACTOR : ED FROEHLING BUILDERS PHONE : (979) 776-8266
OWNER : FROEHLING, EDWARD PHONE :
PARCEL : 106500-0505-0580
A179L NUMBER: 03-00001771 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 6/13/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00
6/16/03 AP AROUND LUNCH TIME
06/13/2003 07:54 AM LLONG
Setback strings , slab ground back right.
B115 O1 .7 -)/03 CH BLDG, FRAMING TIME: 17:00
9/03/03 AP 09/03/2003 09:34 AM MALFORD
09/03/2003 04:18 PM MALFORD
need double cripples under bay window hei
double joists in garage and upstairs bed:
doubled where headered off
B130 01 9/05/03 OC BLDG, INSULATION TIME: 17:00
9/05/03 AP 09/05/2003 07:00 AM MALFORD
B125 01 4 06/04 BI BLDG, FINAL TIME: 17:00
7 O 04/05/2004 12:33 PM MALFORD
-------------------------------------- COMMENTS AND NOTES -------------/
,o BUILDING PERMIT
CITY--OFft"L.LBGJ6STATIO— '
r 1101 TEXAS AVE
.:� COLLEGE STATION, TX 77840t
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number
. . . . . 03-00001771
Date 6/04/03
Property Address .
. . . . . 1109 COEBURN CT
Property ID
106500-0505-0580
R # . . . . . . .
R114162
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name .
. . . . . ALEXANDRIA PH 5
Property Use . . .
. . . . . RESIDENTIAL
Property Zoning . .
. . . . . UNKNOWN
Application valuation . . . . 151866
Owner
Contractor
------------------------
FROEHLING, EDWARD
------------------------
ED FROEHLING BUILDERS
3887 HIGH LONESOME
ED FROEHLING
COLLEGE STATION
TX 778459443 3887 HIGH LONESOME RD
COLLEGE STATION
TX 77845
(979) 776-8266
--------------------------
Structure Information -------------------------
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL -MULTI -FAMILY
Other struct info .
. . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2301.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
5.00
SEWER TYPE
PUBLIC
SERIAL ZONES
248.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
SS
Permit Fee . . . .
616.00 Plan Check Fee
.00
Issue Date . . . .
6/04/03 Valuation . .
. . 151866
Expiration Date . .
12/01/03
Qty Unit Charge Per Extension
BASE FEE 460.00
52.00 3.0000 THOU BLDG, VAL 100001-500000 156.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
-------------------------------------------------- - ----------------------
BUILDING DEW
RESENTATIVE:
APPLICANT:��
BUILDING PERMIT
CITY OF COLLEGE STATIO'
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00001771
Page 2
Date 6/04/03
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH
AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
GUARDS SHALL COMPLY WITH SECTION R-316 (2000 IRC) OR SECTION
1003.2.12 (2000 IBC) AS APPROPRIATE
HANDRAILS SHALL COMPLY WITH SECTION R-315 (2000 IRC) OR
SECTION 1003.3.11 (2000 IBC) AS APPROPRIATE
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND
7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA)
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
•PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
BUILDING DEPT—UP�RESENTATIVE :
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATIO--
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
3
Application Number . . . . . 03-00001771
Date
6/04/03
----------------------------------------------------------------------------
Special Notes and Comments
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-314 (2000 IRC)
OR SECTION
1003.3.3 (2000 IBC) AS APPROPRIATE
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL
SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER
HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY
INSTALL
350.00
WATER TAP 3/4" CITY INSTL
400.00
Fee summary Charged Paid Credited Due
----------------------------------------
-----------------
Permit Fee Total 616.00 616.00
.00
.00
Plan Check Total .00 .00
.00
.00
Other Fee Total 750.00 750.00
.00
.00
Grand Total 1366.00 1366.00
.00
.00
---------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
CITY OF COLLEGE STATION
WO REQUEST
PAGE
1
REQ/JOB: WF0414846 , 001 PROJECT:
REQUEST DATE:
6/04/03
PRINT DATE:
6/04/03
CREW:
PRINT TIME:
14:27:35
SCHEDULE
LOCATION: 1109 COEBURN CT
START:DATES
6/04/03
77845
COMPLETION:
6/04/03
GEN. LOC: COLLEGE STATION LOC ID: 196474
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR: ED FROEHLING BUILDERS ORIGIN:
CUSTOMER -WALK
IN
USER SSTANLEY AUTH: SSTANLEY WORK TYPE:
ROUTINE
�D:
3 4" WATER 4" SEWER
3/4" WATER 4" SEWER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
E
0n
U
APPLICATION FOR BUILDING PERMi i
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US /
DATE: 1,4 Lf Z-!�,,�� •
APPLICATION #n�/ ✓' j 1 1 }�
TEMP POLE # NA
ADDRESS/LOCATION: 1 r 0 V .8i_) ad &0c. 12_- y
LOT BLOCK SUBDIVISION
BUSINESS/OWNER NAME:
PHONE:
CONTRACTOR/HOMEOWNER:.E D I+2 Dig I*4wen & V Ic.D15A PHONE: 7,7,1( • $Z6G
CONTRACTOR ADDRESS: 3867 J%I (if Lonl,� soi✓tE 12'!D Gc�l GE 57,4-Tio.rJ T,!' 77$oo
�j
ELECTRICIAN: Se & P_�LEGT/�!� PLUMBER: -to/PLE "S PC&/jR 4
HVAC: -,'TGn lyP o V/-T'i yE GOOD CENTS (Residential only): Al A
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK:
STRUCTURE USE: SGt)G G 6 FA J4 it, Y 1 Sf E)1,tJG
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ �yS �,6 TOTAL AREA: 2616 .6 HEATED AREA:
(Cost of Labor and Materials)
ePUBLIC SEWER NUMBER OF BEDROOMS:
SEPTICITREATMENT SYSTEM NUMBER OF BATHROOMS:
SEWER TAP: 1 INTERIOR WALL TYPE: S66.67 f2 G,
SV_E�
/WATER TAP: EXTERIOR WALL TYPE: Mwell
SIZE
OTHER TAP:
TEMP POLE
GARAGE TYPE:
SIZE
SINGLE a
ATTACHED
SIGNATURE OF APPLICANT:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE Eff
DETACHED a
TRIPLE
CARPORT
Official Use Only
- goYoEr
ents:
NO
Plans Examiner Zoning Official
i
7
Energy Code Compliance Information
Glazing of exterior walls { 3 2-3 4 --
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating - C/—
P
55�
.
n
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: Untitled.rck
TITLE: 1109 COEBURN COURT
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 05/29/03
DATE OF PLANS: MAY 2, 2003
PROJECT INFORMATION:
SPEC HOME
COMPANY INFORMATION:
ED FROEHLING BUILDER
COMPLIANCE: Passes
Maximum UA = 800
Your Home UA = 651
18.6% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.37
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Front
Projection factor: 0.19
Door l: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Left Side
Projection factor: 0.38
Wall 3: Wood Frame, 16" o.c.
Window 3: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Back
Projection factor: 0.23
Door 2: Glass
<s
Permit Number
Checked By/Date
Gross
Glazing
Area or Cavity
Cont.
or Door
Perimeter R-Value
R-Value
U-Factor UA
2301 30.0
0.0
81
667 13.0
0.0
47
61
0.640 39
38
601 13.0 0.0
56
0.400 15
45
0.640 36
667 13.0 0.0 43
121 0.640 77
18
0.580 10
SHGC: 0.78
Bldg. faces 135 deg. from North; Comp, orient.: Back
Projection factor: 0.56
Wall 4: Wood Frame, 16" o.c. 601 13.0 0.0 46
Window 4: Metal Frame:Double Pane with Low-E 34 0.640 22
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Right Side
Projection factor: 0.38
Floor 1: Slab-On-Grade:Unheated 182 0.0 190
Insulation depth: 0.0'
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in RES checkVersion 3.5 Release lb (formerly MECchec� and to comply with the mandatory requirements listed in
the RES checkInspection Checklist.
Builder/Designer za�'- Date
05/01/2003 TH[1 11.37 FAX 979 693 2554 McClure Engineering Inc, 444 Froehling, Edwar Z003/003
La Now cc
Mow w flmrf " 1
y��9 1
i
i�
Scale: 1" — 20'
lat 97 '
Muir of Flamm* �7 Ur
X3-11W k (i�p i 1(I
N 44:7e'11• F — e,%W'
1 w P.U.L
N
Matra Bldg. Setlladt Llflrf
7ar�nq Ord6�w �1�538
4o.W 7
zot R
,aeaerk sure
-�Phow M
Residence l
S' P.U.E
—
-�\A---J977:74'p
R--eaw'
Coeburn Court Lw4f.55'
5o' rsv w. - 27' pom m a A-.21."
s
LA So
Ed--d On�gg
Vol. 3162, t'q. 7�
I
Uj
tj
I
o
R—Mwo
PWASOV,
37-58bObawp
A&CUIREENGIA+EERIPM, IA/C• fAVtYoa*1WArOmq, .SMAP AV- COAVO.S&AW, 70"s77N •/979,1"M&W