HomeMy WebLinkAboutRES2003-00901PREPARED 9/12/03, 12:07:46 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 9/12/03
------------------------------------------------------------------------------------------------
ADDRESS . : 439 CHIMNEY HILL DR SUBDIV: VILLAS OF CHIMNEY HILLS
TENANT, NBR: SFR-VILLAS OF CHIMNEYHILL
CONTRACTOR BAIRRINGTON HOMES PHONE (979) 690-7801
OWNER COLTRIN, ROBERT B & GLENDA Y PHONE
PARCEL 190300-0000-0060
APPL NUMBER: 03-00000901 RESIDENTIAL, 1 UNIT DETACHED NEW
-------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/25/03 OC BLDG, FOUNDATION -SLAB TIME: 13:00
4/25/03 AP 04/24/2003 08:49 AM LLONG
B1• 01 6/19/03 DS
6/19/03
AP
B150 01
6/20/03
CH
6/20/03
AP
B15 01
9/11/03
CH
9/11/03
DP
SLAB GROUND @ LEFT BACK CORNER
BLDG, FRAMING TIME: 17:00
06/18/2003 01:55 PM SSTANLEY
BLDG, INSULATION TIME: 17:00
06/19/2003 03:27 PM KELMENDORF
after lunch
BLDG, FINAL TIME: 17:00
09/11/2003 09:51 AM SSTANLEY
a NEED ADDRESS BACK SIDE OF HOUSE.
! EVES. LAWN IRRIGATION SYSTEM
B4 5 02 9/1?//0 BI O� BLDG, FINAL TIME: 17:00
//
i a l4 P 09/12/2003 10:13 AM MRODGERS
--------------------------------------
i
RAISE FLUE PIPE 2' ABOVE
COMMENTS AND NOTES --------------------- t4-�------------
CITY OF COLLEGE STATION
WORK
REQUEST
PAGE
1
REQ/JOB:
WF0392381 /
001 PROJECT:
REQUEST DATE:
4/17/03
PRINT DATE:
4/17703
CREW:
PRINT TIME:
13:58:14
SCHSTAARR.T.DATES
LOCATION:
439 CHIMNEY
HILL DR
4/17/03
77840
COMPLETION:
4/17703
GEN. LOC:
COLLEGE STATION LOC ID: 118172
REF NBR:
REQ DEPT:
DE -BUILDING
INSPECTION PRIORITY:
NORMAL
REQUESTOR:
BAIRRINGTON
HOMES (690-7801) ORIGIN:
CUSTOMER -WALK
IN
USER ID:
LLONG
AUTH: LLONG WORK TYPE:
ROUTINE
TEMP POLE
PASSED
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
w,
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
. . . . . 03-00000901 Date 4/14/03
Property Address .
. . . . . 439 CHIMNEY HILL DR
Property ID
190300-0000-0060
R # . . . . . . . .
R21947
Tenant nbr, name .
. . . . . SFR-VILLAS OF CHIMNEYHILL
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name .
. . . . . VILLAS OF CHIMNEY HILLS
Property Use . . .
. . . . . RESIDENTIAL
Property Zoning . .
. . . . . TOWNHOUSE
Application valuation . . . . 171402
Owner
Contractor
------------------------
COLTRIN, ROBERT B &
------------------------
GLENDA Y BAIRRINGTON HOMES
9122 KAPRI LN
DARRELL BAIRRINGTON
HOUSTON
TX 770254202 5010 SPEARMAN DRIVE
COLLEGE STATION TX 77845
(979) 690-7801
--------------------------
Structure Information ----------------------
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL-SFR/DUPLEX
Other struct info .
. . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
HEATED AREA 2597.00
INTERIOR WALL TYPE SHEETROCK.
NUMBER OF BATHROOMS 3.50
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
LL
Permit Fee . . . .
676.00 Plan Check Fee .00
Issue Date . . . .
4/14/03 Valuation . . . . 171402
Expiration Date . .
10/11/03
Qty Unit Charge Per Extension
BASE FEE 460.00
72.00 3.0000 THOU BLDG, VAL 100001-500000 216.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER (S )
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUI MENT
BUILDING DEPT RRE�PRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATIO:
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 03-00000901 Date 4/14/03
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
Door between master bedroom and garage is not allowed.
need to remove door/opening.(international residential
code section R309.1)
Provide landing at each doorway (exterior) min depth of
landing is 36"
Provide hearth in front of fireplace.
PROJECTIONS (OVERHANGS) BEYOND THE EXTERIOR WALL SHALL
-------COMPLY WITH SECTION R302.1, 2000 IRC
---------------�---------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CI ST L 350.00
-------------------------------------------------
BUILDING DEPTTR�EPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY'OF COLLEGE STATIO:
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
3
Application Number
. . . . .
03-00000901
Date
4/14/03
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
WATER TAP 3/4"
CITY INSTL
400.00
Fee summary
-----------------
Charged
Paid
Credited
Due
Permit Fee Total
----------
676.00
----------
676.00
--------------------
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1426.00
1426.00
.00
.00
BUILDING DEPT�REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATIO:
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
03-00000902 Date 4/14/03
Property Address . . . . . .
439 CHIMNEY HILL DR
Property ID . .
190300-0000-0060
R # . . . . . . . . . . . . .
R21947
Application description . . .
TEMP POLE
Subdivision Name . . . . . .
VILLAS OF CHIMNEY HILLS
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
TOWNHOUSE
Application valuation . . . .
0
Owner
Contractor
------------------------
COLTRIN, ROBERT B & GLENDA Y
------------------------
BAIRRINGTON HOMES
9122 KAPRI LN
DARRELL BAIRRINGTON
HOUSTON TX 770254202
5010 SPEARMAN DRIVE
COLLEGE STATION
TX 77845
(979) 690-7801
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . LL
Permit Fee . . . . 20.00
Issue Date . . . . 4/14/03
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
Fee summary Charged
-----------------
Paid Credited
Due
----------
Permit Fee Total 20.00
------------------------------
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
BUILDING DEPT REPRESENTATIVE:
APPLICANT
CITY OF COLLEGE STATION
W0: ZEQUEST
PAGE
1
REQ/JOB: WF0391670 i 001 PROJECT:
REQUEST DATE:
4/15/03
PRINT DATE:
4/15/03
CREW:
PRINT TIME:
10:56:52
SCHSTAARRT.DATES
LOCATION: 439 CHIMNEY HILL DR
4/15/03
77840
COMPLETION:
4/15703
GEN. LOC: COLLEGE STATION LOC ID: 118172
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR: BARRINGTON HOMES ORIGIN:
CUSTOMER -WALK
IN
USER D: SSTANLEY AUTH: SSTANLEY WORK TYPE:
ROUTINE
3�4" WATER 4" SEWER
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
3/4" WATER 4" SEWER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
kJ"
F-W Oak* use any
_ _..'LICATION FOR BUILDING PER
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEG E-STATION.TX. US
DATE. 3'?)I-o 3
APPLICATION M U5 0
TEMP POLE # D �`'10
ADDRESS`/LOCATION: •V31 61#1 lVey k" A94"19
LOT 6 BLOCK A SUBDIVISION 4,114AAS Of C#11#4 i y -116 e-
BUSINESS/OWNER NAME: /.nou GPHONE: -?jo/
CONTRACTOWHOMEOWNER: AAw&`/,� B/�/J^/'l1ut.Tm�U PHONE: Ce�� i a/
CONTRACTOR ADDRESS:
ELECTRICIAN: Tomes WEST
HVAC: I¢G` 6A.4U17 A?<
PLUMBER: .O d oq
GOOD CENTS (Residential only): o
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) EW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK:
STRUCTURE USE: ,51' GG& A0M6
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: Ye4
TEXAS ACCESSIBILITY STANDARD AS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ Ad � TOTAL AREA: 3/YO HEATED AREA: �707
(Cost-61 LatZr and Matedials
PUBLIC SEWER
NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM
NUMBER OF BATHROOMS:
SEWER TAP: 1
INTERIOR WALL TYPE:
cW&-4-T1FbC,/C
SI
WATER TAP: 3 7EXTERIOR
WALL TYPE:
,ai/LJrC ,5 %0/a E
SME
❑ OTHER TAP:
FOUNDATION TYPE:
S¢E
TEMP POLE
ROOF TYPE:�f�j�(,-=
GARAGE TYPE: SINGLE
DOUBLE � TRIPLE
ATTACHED a
DETACHED a CARPORT
SIGNATURE OF APPLICANT:
Official Use Only
ants:
A
ES Or NO
Plans Examiner
Zoning Official
6`
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
X .13
tf 3o
Insulation R value of ceiling 2 (vaulted areas/no attic) ho-/?
Glazing SHGC
Glazing U-Factor
R value of ductwork - -,
A/C SEER rating
A�
• •' yM V
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 03- DATE:
0 � a o3
BUILDING ADDRESS:
439 _ i►mnev t ►ve.
I. Foundation Requirements
NA/OK
A. Concrete minimum f c of 3000 PSI
p
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' Ion
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Re uirements
NA/OK
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
NIN
1. One -hour rated extending to roof deck
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall coverin indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, rade and direction of span indicated on plans
L. Attic access location and size indicated on plans
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
NA/OK
M. Span exceeding code tables must be engineered
Q
N. Rafter size, spacing, grade, roof slope & bracing (if required to reduce span) indicated
on plans
O. Roof covering
1. Roof decking indicated on plans
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
14 o e,
R. Overhangs not allowed on zero lot line construction
S. Protected openings on walls < three feet from property line
III. Stairway Requirements
N OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated on plans
NA/OK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward)B.
Masonry fireplace requires 2" clearance from all combustible materials
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of
the buildingwithin ten 10 feet horizontal
�K
V. Electrical Service Requirements
NA/OK
A. Electrical plan to include:
o
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
NA/OK
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N OK
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NA10K
A. Compliance_ software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
p
Zoning Ordinance Requirements — Ordinance 850
NA/OK
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Overhangs not allowed on zero lot line construction
20' triangle clear at comer
Required parking
Street Ordinance Requirements
NA/OK
Maximum drive width for residence is 28'
Minimum 30 feet from driveway to side(intersecting) street
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
Subdivision Regulations — Ordinance 690 NA/OK
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301 OK
Does not block any water course
Need elevation certificate
ZONING OFFICIAL
DATE
q a 163
PLANS EXAMINER bATE