HomeMy WebLinkAboutRES2003-00896PREPARED 1/29/04, 12:07:40
INSPECTION TICKET PAGE 1
City of
College Station
INSPECTOR: BUILDING INSPECTOR DATE 1/29/04
------------------------------------------------------------------------------------------------
ADDRESS
. : 1106 ROYAL ADELADE
DR SUBDIV: PEBBLE CREEK
TENANT,
NBR: SFR
CONTRACTOR KITCHEN
DESIGNS
PHONE : (979) 774-4571
OWNER
NGUYEN,
JOHN Q T MD & PHONE :
PARCEL
497900-0040-0030
APPL NUMBER: 03-00000896 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B10_0 01
5/19/03
TB
BLDG, FOUNDATION -SLAB TIME: 17:00
5/20/03
AP
05/16/2003 02:11 PM KELMENDORF
after lunch
SLAB GROUND MIDDLE OF BACK WALL IN BATHROOM BETWEEN TUB AND
WATER CLOSET VENT
STRINGS ON SETBACKS OK - BACK RIGHT CORNER RIGHT ON
B115 01
7/21/03
TB
BLDG, FRAMING TIME: 17:00
7/22/03
DP
07/21/2003 08:23 AM KELMENDORF
NEED TO COVER OSB AROUND ENTRY WAY FOR MOISTURE BARRIER.
NEED TO SHEETROCK FIREPLACE FROM 10' LEVEL UP WITH EXPOSURE
TO ATTIC SPACE. CHECK MASTER BATH WINDOWS OR BLOCKS? NOT
YET INSTALLED TO CHECK TEMPERED. FIREBLOCK AREAS MARKED ON
FLOOR. NEED ANCHOR BOLTS IN PERIMETER WALL OF MASTER
BATH ALONG TUB AND SHOWER WALL. MISSING ANCHOR BOLT NUTS
OR LOOSE MARKED ON FLOOR. HAS FLOATING BEAM WITH WITH TIE
'
DOWN STRAPS HANGING BEAM.
B115.02
7/22/03
CW
BLDG, FRAMING TIME: 17:00
i
7/23/03
DP
07/22/2003 08:15 AM KELMENDORF
MISSING ANCHOR BOLT IN GARAGE
B130 01
7/24/03
TB
BLDG, INSULATION TIME: 17:00
7/24/03
AP
07/23/2003 02:16 PM KELMENDORF
first thing this morning if possible
C
B125 01
1/28/04
TB
BLDG, FINAL TIME: 17:00
1/28/04
CA
O1/28/2004 11:19 AM MALFORD
B125 02
1/29/04
BLDG, FINAL TIME: 17:00
01/29/2004 09:08 AM SSTANLEY
-------------------------------------- COMMENTS AND NOTES--------------------------------------
Cq- /
M fwv
CITY OF COLLEGE STATION
..
WORK QUEST
PAGE
1
REQ/JOB:
WF0405488 / 001 PROJECT:
REQUEST DATE:
5/15/03
PRINT DATE:
5/15/03
CREW:
PRINT TIME:
8:18:30
SCHEDULE
DATES
LOCATION:
3505 FARAH DR
START:
/
77845
COMPLETION:
515/03
GEN. LOC:
COLLEGE STATION LOC ID: 197584
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
M/W Construction ORIGIN:
CUSTOMER -WALK
IN
USER ID:
KELMENDORF AUTH: KELMENDORF WORK TYPE:
ROUTINE
temp pole
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
approved
temp pole approved
Category code .
Task code:
Facility ID .
Assigned Department:
CS -CUSTOMER SERVICES
SET UP NEW UTILITY ACCT
OT-CUSTOMER SERVICE
CSCS
SET
CITY OF COLLEGE STATION
WOR EQUEST PAGE 1
REQ/JOB: WF0402694 /'001 PROJECT: REQUEST DATE: 5/12/03
PRINT DATE: 5/12/03
CREW: PRINT TIME: 10:18:40
SCHEDULE DATES
LOCATION: 1106 ROYAL ADELADE DR START:
77845 COMPLETION: 5// 1203
GEN. LOC: COLLEGE STATION LOC ID: 187292
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: KITCHEN DESIGNS (774-4571) ORIGIN: CUSTOMER -WALK IN
USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE
4" SEWER AND 3/4" WATER
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
4" SEWER AND 3/4" WATER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
�4 BUILDING PERMIT
,k,,, , ' ION'
,�
_11101 T
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number
. . . . . 03-00000896 Date 5/12/03
Property Address .
. . . . . 1106 ROYAL ADELADE DR
Property ID
497900-0040-0030
R # -
- - R105215
Tenant nbr, name .
. . . . . SFR
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name .
. . . . . PEBBLE CREEK
Property Use . . .
. . . . . RESIDENTIAL
Property Zoning . .
. . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 250000
Owner
Contractor
------------------------
NGUYEN, JOHN Q T MD
------------------------
& KITCHEN DESIGNS
JACQULYN V
ANGEL NEGRETE
305 CECILIA LOOP
1861 BRIARCREST DR
COLLEGE STATION
TX 778456310 BRYAN TX 77802
(979) 774-4571
--------------------------
Structure Information -------------------------
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL-SFR/DUPLEX
Other struct info .
. . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 3.00
HEATED AREA 3686.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 4.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
LL/ANGEL
Permit Fee . . . .
910.00 Plan Check Fee .00
Issue Date . . . .
5/12/03 Valuation . . . . 250000
Expiration Date . .
11/08/03
Qty Unit Charge Per Extension
BASE FEE 460.00
150.00 3.0000 THOU BLDG, VAL 100001-500000 450.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER (S )
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUI ENT
BUILDING DEPT REP ESENTATIVE:
APPLICANT: i�
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00000896
Page 2
Date 5/12/03
Special Notes and Comments
ELECTRICAL SHALL BE INSTALLED PER.199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
Other Fees . . . . . . . . .
Fee summary Charged
SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Paid Credited Due
-------------------------------------------------------
BUILDING DEPT REP ESENTATIVE:
APPLICANT: 11\
BUILDING PERMIT
`
CITY OF COLLEGE STATIOZ
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE:
--------------------------------------------------------------------------
(979)764-3570 FAX: (979)764-3496
Page
3
Application Number
03-00000896
Date
5/12/03
Permit Fee Total
910.00 910.00
.00
.00
Plan Check Total
.00 .00
.00
.00
Other Fee Total
750.00 750.00
.00
.00
Grand Total
1660.00 1660.00
.00
.00
-------------------------------------------------- -- ----- -- --------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: a ` N
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number
. . . . .
03-00000897 Date
5/12/03
Property Address .
. . . . .
1106 ROYAL ADELADE DR
Property ID
. .
497900-0040-0030
R # . . . . . . . .
. . . . .
R105215
Application description
. . .
TEMP POLE
Subdivision Name .
. . . . .
PEBBLE CREEK
Property Use . . .
. . . . .
RESIDENTIAL
Property Zoning . .
. . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation
. . . .
0
Owner
Contractor
------------------------
NGUYEN, JOHN Q T MD
&
------------------------
KITCHEN DESIGNS
JACQULYN V
ANGEL NEGRETE
305 CECILIA LOOP
1861 BRIARCREST DR
COLLEGE STATION
TX 778456310
BRYAN
TX 77802
(979) 774-4571
----------------------------------------------------------------------------
Permit . . . . . .
TEMP POLE
PERMIT
Additional desc . .
LL/ANGEL
Permit Fee . . . .
20.00
Issue Date . . . .
5/12/03
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . .
. . . . .
TEMP ELECT POLE CONNECT
45.00
Fee summary
-----------------
Charged
----------
Paid Credited
------------------------------
Due
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
------------------------
BUILDING DEPT RE
APPLICANT:
\SENTATTVE :
LL
Fof afire use 0*
APPLICATION FOR BUILDING PERMIT
EaCITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW�l.CI.COLLEGE-STATION.TX.US
ADDRESS/LOCAT N: I RoALLI/ I
LOT BLOCK Lt L-D SUBDIVISION
i'11 ` 1
BUSINESS/OWNER NAME: � t
CONTRACTOR/HOMEOWNER:��r 01.
CONTRACTOR ADDRESS: "b Y )i
ELECTRICIAN:
HVAC: L- A V C �
PLUMBER:
DATE: J - 3 — 3
APPLICAT1oN #
TEMP POLE # Ow^l � 1 ✓/
PHONE:
PHONE: 77N —"I s 7
0
GOOD CENTS (Residenfial only):
CLASS OF WORK
�� -I-wo -a
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK: NeW IZC*4 0—
STRUCTURE USE: A avcV v
HOMEOWNER ASSOCIATIQN/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE' APPROVAL: '�-
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 2.5 L / 00 0 X TOTAL AREA: 536-7
(Cost of Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP:
SizE
WATER TAP:
Sim
OTHER TAP:
SIZE
TEMP POLE
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
GARAGE TYPE: SINGLE [—] DOUBLE
ATTACHED ��ETACHED
SIGNATURE OF APPLICANT:
HEATED AREA: 6 36
2X L
let
L. om
!' Of#vial Use Only ents:
+ 03' �E7SrNO
Plans Examiner Zoning Official
s
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas) 1�
Insulation R value of ceiling 2 (vaulted areas/no attic) ►—
Glazing SHGC
Glazing U-Factor
_
R value of ductwork
A/C SEER rating
�_
.4
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# DATE:
0- 'i3o3
BUILDING ADDRESS: ` r
I. Foundation Requirements
NA/OK
A. Concrete minimum f c of 3000 PSI
O
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' Ion
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
11. Framing: Floor, Wall, Coiling and Roof Requirements
NA/OK
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
1. One -hour rated extending to roof deck
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of fo -four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
1. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, rade and direction of span indicated on plans
L. Attic access location and size indicated on plans
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
NA/OK
M. Span exceeding code tables must be engineered
0(
N. Rafter size, spacing, grade, roof slope & bracing (if required to reduce span) indicated
. on plans
O. Roof covering
1. Roof decking indicated on plans
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
L
R. Overhangs not allowed on zero lot line construction
S. Protected openings on walls < three feet from property line
III. Stairway Requirements
K
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
NA10K
A. Hearth extensions
—
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
-
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of
the building within ten 10 feet horizontal
V. Electrical Service Requirements
N - PK
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
N OK
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/OK
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
NA/OK
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NAIOK
Permitted use for district
r-
Density requirements
MA
Minimum lot size
Setbacks
Easements
Overhangs not allowed on zero lot line construction
Required parking
Street Ordinance Requirements
NA/OK
Maximum drive width for residence is 28' combined for circular
Minimum 30 feet from driveway to side(intersecting) street
Driveway access to lesser street for comer lots
1p
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
Subdivision Regulations — Ordinance 690 NA/OK
ADDroved subdivision Av
Plat filed
Flood lain Regulations — Ordinance 1301 N vK
Does not block any water course or divert any flow
Elevation certificate needed
Comments:
ZONING OFFICIAL
CIS
PLANS EXAMINER
Lena, n
DATE
0
DATE