HomeMy WebLinkAboutRMDL2003-00348 402 NAGLE ST BUILDING PERMITyr,
r•�+= ��r� BUILDING PERMIT
_. Ti�
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
-----------------------------------------------------------------------------
Application Number . . . . . 03-00000348 Date 2/07/03
Property Address . . . . . . 402 NAGLE ST
Property ID . . . . . . . . . - -
R# . . . . . . . . . . . . .
Tenant nbr, name NEWPORT CONDOS
Application description RESIDENTIAL, REMODEL & RENOVATION
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . . UNKNOWN
Application valuation . . . . 30000
Owner Contractor
------------------------ ------------------------
G —
Co I ke �eo� I Es-l�t-fie
peY In e. n
------ Structure Information REPLACE SHEETROCK FIRE SEPERATION @ GARG-----
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . **NEEDS TO BE ENTERED**
Other struct info . . . . . IMPACT/PRORATA FEES PAID NA
HEATED AREA 1.00
INTERIOR WALL TYPE SHEETROCK
SEWER TYPE PUBLIC
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . LL
Permit Fee . . . . 160.00 Plan Check Fee .00
Issue Date . . . . 2/07/03 Valuation . . . . 30000
Expiration Date . . 8/06/03
Qty Unit Charge Per Extension
BASE FEE 15.00
29.00 5.0000 THOU BLDG, VAL 1001-50000 145.00
----------------------------------------------------------------------------
Special Notes and Comments
Post permit card on site
Provide blocking between 211x 8" joists for bracing
Provide fire caulk around penetrations (plumbing
lines,etc.) per manufactures' recommendations.
Feb.7, 2003, For trial portion to be complete within 7 days
and the remainder to be complete within the next 3 weeks.
Total time to finish project and have inspection within 30
days.
Fee summary Charged Paid Credited Due
---------------------------------------------
BUILDING DEPT REI?,2ESENTATIVE:
APPLICANT: I r-i,(llA L I1/,ar\`
BUILDING PERMIT
CITY OF COLLEGE STATIO]
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE:
----------------------------------------------------------------------------
(979)764-3570 FAX: (979)764-3496
Page
2
Application Number
. . . . . 03-00000348
Date
2/07/03
-----------------
Permit Fee Total
------------------------------
160.00 160.00
----------
.00
.00
Plan Check Total
.00 .00
.00
.00
Grand Total
160.00 160.00
.00
.00
----------------------------------------------------
BUILDING DEPT REPREgENTATIVE:
APPLICANT:
1s7 i .
E3APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COOLLEGESTATION.TX.US / L
ADDRESS/LOCATION: Log, hl('ap
For Office Use Only
DATE 116 / Q 7:�->
APPLICATION # 03 -3421
TEMP POLE #
ka —
LOT BLOCK SUBDIVISION Q�l
BUSINESS/OWNER NAME: 1'b- 0C, PHONE:
CONTRACT HOMEOWNER: 1 ` PHONE:_
CONTRACTOR ADDRESS: _ _ r OIL 9ft
ELECTRICIAN:
HVAC:
PLUMBER:
GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL
DESCRIPTION OF WORK: plaC(q 0 5%-e cc tk (afeo Jet"
ANrcl, e �P c rrlU
STRUCTURE USE:
HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 30, 000
TOTAL AREA: HEATED AREA:
(Cost of Labor and Materials)
PUBLIC SEWER
NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM
NUMBER OF BATHROOMS:
SEWER TAP:
INTERIOR WALL TYPE:
SIZE
WATER TAP:
EXTERIOR WALL TYPE:
SIZE
OTHER TAP:
FOUNDATION TYPE:
SIZE
TEMP POLE
ROOF TYPE:
GARAGE TYPE: SINGLE F--]
DOUBLE F—] TRIPLE
ATTACHED F1
DETACHED F--] CARPORT
SIGNATURE OF APPLICANT:
R'.' L
Official Use Only Comments:
YES or NO
Plans Examiner
Zoning Official
Slcei
'Yj�an1
Gard
ED I I
C
props Work
A-
0
FJY 7F4
jd;-
Fx//
_.c$.ON
FLOOR-CEILING=SYSTEMS, WOOD FRAMED
GA-FILEAO. FC 5300:
WOOD JOISTS, GYPSUM WALLBOARD, RESILIENT CHANNELS
One layer 1/2" type X gypsum wallboard or gypsum veneer base applied at right angles to
resilient furring channels 24" o.c. with 1" Type S drywall screws 12" o.c. Gypsum board
end joints located midway between continuous channels and attached to additional
pieces of channels 53" long with screws 12" o.c. Resilient furring channels applied at
right angles to 2 x 10 wood joists 16" o.c. with two 4d coated nails, 11/2" long, 0.080"
shank, and 7/32" heads, per joist. Wood joists supporting 1" nominal T & G wood subfloor
and 1" nominal wood finish floor, or 5/s" plywood finished floor with long edges T & G and
15/32" interior plywood with exterior glue subfloor perpendicular to joists with joints
staggered.
GA FILE NO., FC,5310- GENERIC
WOOD JOISTS, GYPSUM WALLBOARD
One layer 5/s" type X gypsum wallboard or gypsum veneer base applied at right angles to
rigid furring channels 24" o.c. with 1 " Type S drywall screws 12" o.c. Gypsum board end
joints located midway between continuous channels and attached to additional pieces
of channel 60" long with screws 12" o.c. Rigid furring channels applied at right angles to
4 x 10 or double 2 x 10 wood joists 48" o.c. with two 11/4" Type S drywall screws at each
joist. Wood joists supporting 11/a " T & G plywood floor.
GA FILE NO. FC 54M 1 1 . ,.GENERIC
WOOD JOISTS, GYPSUM WALLBOARD
Base layer 5/e" type X gypsum wallboard applied at right angles to 2 x 10 wood joists 24"
o.c. with 11/4" Type W or S drywall screws 24" o.c. Face layer 5/8" type X gypsum
wallboard or gypsum veneer base applied at right angles to joists with 17/e" Type S
drywall screws 12" o.c. at joints and intermediate joists and 11/2" Type G drywall screws
12" o.c. placed 2" back on either side of end joints. Joints offset 24" from base layer
joints. Wood joists supporting 1/2" plywood with exterior glue applied at right angles to
joists with 8d nails. Ceiling provides one hour fire resistance protection for wood
framing, Including trusses.
This Space Left Blank
HOUR 40 to 44,STC
FIRE I I SOUND
----------- ----------------- "I -----------
1 1
1 1
oil
Approx. Ceiling
Weight:
2 psf
Fire Test:
UL R3501-29, 3-23-64,
UL Design L515
Sound Test:
NGC 4010, 3-21-66
(Rev. 12-23-70)
IIC & Test:
38 (63 C & P)
NGC 5016, 3-17-66
1 HOUR 40 to 44 STC.
FIRE I I SOUND
Approx. Ceiling
Weight: 2.5 psf
Fire Test: UL R1319-47, 5-8-63,
UL Design L508
Sound Test: Estimated
1. HOUR I 35 to 39 STC
FIRE SOUND
Approx. Ceiling
Weight: 5 psf
Fire Test: FM FC 172, 2-25-72
Sound Test: Estimated
GA-600-2000 1 Contact the manufacturer for more detailed information on proprietary products. 109
¢ a-
z 0
" j,
zX
ot,
��Y13