HomeMy WebLinkAboutSIGN2003-00007 THE CAMBRIDGE AT COLLEGE STATION 501 UNIVERSITY OAKS BLVD AThe exterior of this wall is 48 feet wide by 14 feet high
with studs every 16". We would then follow with a
4 color digital canvas banner (Facade A drawings
attached) that would be stretched and installed on
the wall. The wall itself would be anchored at the
base to the cement and braced to the trailer, it would
have to clear the trailer tongues (hitches) and leave
ample space for the AC's to get air.
FACADE
A
*All of this is contingent upon City approval,
1 spoke with Carl Warren (City of College Station)
today (12119102) and verbally walked him through it.
1 told him after your review and input 1 would submit
the package to them.
Student
Housing,, -
Cyber Loungi
KIN
Individual
Leases
State -of -the -Art
Fitness Center
48'
C C�'Icllg- e
Ca college station
student housing
Full Service Dining Center
k
i.
ti'I
V
e
Beach Entry Pool,
Water Volleyball
& Tanning Pool
Game Room with
Billiards
Ping Pong &
Video Games
Maid Service
12
College station
student housing
door
ge
14'
facade A
Facade B
14'
T
j
T
2'
1
9'
e
This wall will be 56 feet long by 14 feet high with vertical studs rising
every 16" and will attach directly to the face of the trailer. A cutout will
wrap around the deck and the front door. We would then come back with
a 4 color digital canvas banner (Facade 6 drawings attached) that would
be stretched and installed on the wall.
R im
CUT—OUT
AROUND DECK \
jj DOOR
(5
9- DECK
+~a
FACADE
8
The exterior of this wall is 48 feet wide by 14 feet high
AC with studs every 16". We would then follow with a
4 color digital canvas banner (Facade A drawings
attached) that would be stretched and installed on
the wall. The wall itself would be anchored at the
base to the cement and braced to the trailer, it would
have to clear the trailer tongues (hitches) and leave
ample space for the AC's to get air.
AC
AC
AC
FACADE
A
*All of this is contingent upon City approval,
1 spoke with Carl Warren (City of College Station)
today (12119102) and verbally walked him through it.
I told him after your review and input 1 would submit
the package to them.
Student
H o u s i n g L
_ , �
CyberLoungt
35'
Individual
Leases
State-of-the'l-Art
Fitness Center
4 8'
m b' rict
g e
college station
student housing
Full Service Dining Center
li
Beach Entry Pool,
Water Volleyball
& Tanning Pool1�
N
ZI
PC
Game Room with
Billiards
Ping Pong &
Video Games
Maid Service
12
Y I d
abridge
D e station
student housing
door
14'
facade A
Facade B
14'
T
2'
1
91
: SIGN PERMIT
"'CI'TY—OF � COLLEGE -STATION
1101 - TEXAS- AVE""P
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00000007 Date 1/30/03
Property Address — __ _. 501_ UNIVERSITY OAKS BLVD- A
Property ID - -
R #
Application description . . . SIGN PERMIT
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . . UNKNOWN
Application valuation . . . . 13580
Owner
Contractor
------------------------
------------------------
FOURCE COMMUNICATIONS
MURPHY WEBSTER
1351 REGAL ROW
DALLAS
TX 75247
(214) 630-2125
--------------------------
Structure
Information -------------------------
Construction Type . .
. . . **NEEDS
TO BE ENTERED**
Sign Type . . . . . .
. . . WALL
SIGN
----------------------------------------------------------------------------
Permit . . . . . .
SIGN PERMIT
Additional desc . .
LL/MURPHY
Permit Fee . . . .
80.00
Plan Check Fee
.00
Issue Date . . . .
1/30/03
Valuation . . . .
13580
Expiration Date . .
7/29/03
Qty Unit Charge
Per
Extension
BASE
FEE
15.00
13.00 5.0000
THOU BLDG,
VAL 1001-50000
65.00
----------------------------------------------------------------------------
Other Fees . . . . .
. . . . SIGN
PERMIT REVIEW FEE
25.00
Fee summary Charged
----------
----------
Paid Credited
--------------------
Due
-----------------
Permit Fee Total
80.00
80.00 .00
.00
Plan Check Total
.00
.00 .00
.00
Other Fee Total
25.00
25.00 .00
.00
Grand Total
105.00
105.00 .00
.00
----------------
BUILDING l
APPLICANT
CITY OF COLLEGE STATION
For O//Ice Use Only
1101 TEXAS AVENUE --DATE SUBMITTED:
COLLEGE STATION, TX 77840 �Q
;979) 764-3570 (979) 764-3496 FAX APPLICATION #
NWW.CI.COLLEGE-STATION.TX.US Plan Review Fee $25.00
—tom CAA,-(3 ia( C),.- 6C.-,*
ADDRESS/LOCATION:__I
LOT BLOCK SUBDIVISION
BUSINESS NAMEp. M�U�� LXt���_$7r_p^/_ PHONE:
77P�6
CONTRACTOR: _ cosrtiwi�c�S_LT13 PHONE: QT�• �Llt 5t l �`
CONTRACTOR ADDRESS:
ELECTRICIAN: PHONE:
f�*+r TYPE OF SIGN
ATTACHED/WALL: Pictures/Graphics that show where the sign(s) will be placed
h [Signs may not be 12" or more above the roofline or protrude out from the building more than 12"]
Q DEVELOPMENT SIGN
� Q' FREESTANDING
�► Site Plan — Be sure to include to Engineering scale:
Frontage:_[the length of the property line along the roadway to which the sign is oriented]
Location of the proposed sign; Distance from the curb to the front edge of the sign;
Distance from property line, if using Note 5 of the Sign Table
Sign Graphic — Be sure to include to Engineering scale and show:
Sign Height and Square Footage of the sign.
[Please note: The area of a freestanding sign is the area enclosed by the minimum imaginary
rectangle of vertical and horizontal lines which fully contain all extremities.]
Additional submittal requirements for signage in Wolf Pen Creek (WPC), Northgate (NG),
Overlay District (OV), and the City of College Station Business Center.
(VALUATION-(Labor/Materials): $
SIGNATURE OF APPLICANT:
,--SQUARE FT_._—�
♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦
Plans Examiner
COMMEN
YES o O
1'
12-23-02
Carl warren F O U R C E
City of College Station
1101 Texas Ave. COMMUNICATIONS
College Station,Tx. 77840
Carl,
Attached you'll find some layouts of the walls we discussed last Thursday (12-19-02).
As stated, the client has more money then sense and I'm willing to take all that I can get.
What we want to accomplish is actually pretty special and would bring valued attention
to the project, as you know the window for leasing up a student residence is very narrow
and any additional traffic we can stimulate will be needed.The digital facades are temporary
and will be constructed as needed to be structurally sound and safety conscious.
This will be the 5th time we've done something of this nature and we've not only done it
extremely well, we've learned something each time that now can be implemented into the
Cambridge project.
Carl, I've been given the go ahead by the client, I informed them that it was all contingent on
City approval, naturally their first question was..."when can we have it?"
Please give me a call upon the receipt and review of the enclosed, you stated you would need
to get this in front of others .... so if you need anything else ... let me know....
I appreciate any and all help you can give me in getting this project expedited.
Thank you,
GYI.
Murphy Webster 3
F-
w
N X Z W 3 � Z
U O ch
� V) 1 00
V
O
O
—�¢N
I w V M�
~¢O--J
I Q w
1351 REGAL ROW DALLAS, TEXAS 75247 FON 214-630-2125 FAX 214-630-2314