HomeMy WebLinkAbout06-702PREPARED
8/11/06, 12:01:18
INSPECTION TICKET PAGE 5
City of
College Station
INSPECTOR: BUILDING INSPECTOR DATE 8/11/06
------------------------------------------------------------------------------------------------
ADDRESS
. : 3807 RANSBERG CT
SUBDIV: EDELWEISS GARTENS PH 6
CONTRACTOR HERMAN E COUCH -
BUILDER PHONE (979) 690-7813
OWNER
EDELWEISS GARTEN
VENTURE PHONE
PARCEL
244030-0613-0040
APPL NUMBER: 06-00000702 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
4/13/06 OC
BLDG, FOUNDATION -SLAB TIME: 17:00
4/13/06 AP
T/S: 04/13/2006 10:14 AM GLSOUTH -----------------------
Strings On Setbacks O.K.
Slab Ground Installed
B115 01
5/19/06 OC
BLDG, FRAMING TIME: 17:00
5/19/06 AP
May 18, 2006 8:45:37 AM bkorthauer
B130 01
5/26/06 BH
BLDG, INSULATION TIME: 17:00
5/26/06 AP
May 26, 2006 10:57:39 AM bkorthauer
May 26, 2006 10:57:48 AM bkorthauer
INSURE THAT ALL OSB IS COVERED WITH HOUSE WRAP AND ALL
JOINTS ARE TAPED.
B125 01
8/11/0 BI
TAPE AROUND ALL WINDOWS AT 1X4 AND HOUSE WRAP.
BLDG, FINAL TIME: 17:00
i K
August 11, 2006 10:26:46 AM kwolfe
--------------------------------------
COMMENTS AND NOTES --------------------------------------
0
Date: 8/11 /2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 702
Address: 3807 RANSBERG CT
Insp.
Inspection Type Code
Description
p.
Status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B130
BLDG, INSULATION
IC
May 26, 2006 10:57:48 AM bkorthauer
B130
BLDG, INSULATION
IC
INSURE THAT ALL OSB IS COVERED WITH HOUSE
WRAP AND ALL
B130
BLDG, INSULATION
IC
JOINTS ARE TAPED.
B130
BLDG, INSULATION
IC
TAPE AROUND ALL WINDOWS AT 1X4 AND HOUSE
WRAP.
M110
MECH, FINAL
IC
May 12, 2006 10:27:27 AM bkorthauer
Page 1
Brittany Korthauer -Insulation request inspection result, 380� Ransberg, 06
From: Brian Henry
To: Southerland, Gina
Date: 5/26/2006 10:54:33 am
Subject: Insulation request inspection result, 3807 Ransberg, 06-702
CC: Korthauer, Brittany; Wolfe, Kim
Print for file
Inspected insulation, 3807 Ransberg, 06-702, Couch Homes, 5-26-06
Inspection result: Inspected OK for Good Cents
Notes:
Insure that all OSB is covered with house wrap and all joints are taped.
Tape around all windows at lx4 and house wrap.
WF0762573 / 001 City of. College Station PAGE 1
REQ. DATE: 04/24/06 (' -`I Q 04/24/06 13:42:57
LOCATION: 3807 RANSBERG CT LOC ID: 201906
REQUESTOR: HERMAN E COUCH BUILDER ORIGIN: CUSTOMER -WALK IN
REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 04/24/06 SCHED COMPLETION: 04/24/06
********************************************************************************
JOB ORDER RESULT COMIENTS
WF0752185 / 001 City of College Station PAGE 1
REQ. DATE: 03/13/06 r=i 03/13/06 11:20:17
LOCATION: 3807 RANSBERG CT ? LOC ID: 201906
REQUESTOR: HERMAN COUCH -COUCH HOMES ORIGIN: CUSTOMER -WALK IN
REQ. USER: BKORTHAUER AUTH. USER:, BKORTHAUER WORK TYPE: ROUT
4" SEWER TAP AND 3/4" WATER TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/13/06 SCHED COMPLETION: 03/13/06
********************************************************************************
4riT:wi):103Di I'm ti31,11IF$dKKe)uIzINZwY.`�
Cit�r of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . . 8/14/06
Parcel Number . . . .
. 244030-0613-0040
Property Address . .
. 3807 RANSBERG CT
COLLEGE STATION TX 77845
Subdivision Name . .
. EDELWEISS GARTENS PH 6
Legal Description . .
. EDELWEISS GARTENS #6, BLOCK 13
, LOT 4
Property Zoning . . .
. SINGLE FAMILY RESIDENTIAL
Owner . . . . . . . .
. EDELWEISS GARTEN VENTURE
Contractor . . . . .
. HERMAN E COUCH - BUILDER
979 690-7813
Application number
06-00000702 000 000
Description of Work
RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . .
. COMBUSTIBLE (UNPROTECTED)
Occupancy type . . .
. RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . .
Approved .
BuiVding Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
r
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLAN REVIEW/PERMIT NUMBER# Q� _ 7a
DATE: 3 /9 lob
BUILDING ADDRESS: 3ga
wj
I. Foundation Requirements
N
A.
Concrete minimum f'c of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier
1. 6 mil poly
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Narrow Wall Bracing Methods indicated on plans
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill -height of fort -four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M.
N.
Span exceeding code tables must be engineered
Rafters sizes, spacing, grade, slope and purlins if required.
4
CITY OF COLLEGE STATION
Planning Cr Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NA/
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
ylk
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6") inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated on plans)
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
(*hr,o"
CITY OF COLLEGE STATION
Planning & Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
NAKH
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
N
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks -
Easements
Required parking
On zero lot side 18" max. overhang allowed
Vok
Street Ordinance Requirements
NA/
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side (intersecting) street
Subdivision Regulations — Ordinance 690
N AkUkj
Approved subdivision
77
Plat filed
Floodplain Regulations — Ordinance 1301
OK
Does not block any water course or divert any flow
Elevation certificate if required
�A'
CITY OF COLLEGE STATION
Planning & Development Services
Comments:
ANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
vo
DATE
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
--------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning. . . . . . .
Application valuation . . . .
06-00000702 Date 3/13/06
3807 RANSBERG CT
244030-0613-0040
R301755
RESIDENTIAL, 1 UNIT DETACHED NEW
EDELWEISS GARTENS PH 6
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
112926
Owner
Contractor
------------------------
EDELWEISS GARTEN VENTURE
------------------------
HERMAN E COUCH -
BUILDER
311 CECILIA LOOP
HERMAN E COUCH
COLLEGE STATION
TX 778456310 1282 STAUFFER CIRCLE
COLLEGE STATION
TX 77845
(979) 690-7813
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1711.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
BK
Permit Fee . . . .
499.00 Plan Check Fee
.00
Issue Date . . . .
3/13/06 Valuation . .
. . 112926
Expiration Date . .
9/09/06
Qty Unit -Charge
Per
Extension
BASE FEE
460.00
13.00 3.0000
THOU BLDG, VAL 100001-500000
39.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
-------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
- - - - - - - - -
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
06-00000702
Page 2
Date 3/13/06
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 . FAX; (979) 764-3496
Application Number . . . . . 06-00000702
Page 3
Date 3/13/06
Special Notes and Comments
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 • FAX,: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number
. . . . . 06-00000702
Date
3/13/06
----------------------------------------------------------------------------
Special Notes and
Comments
SUCH THAT THE IGNITION
SOURCE IS 18" ABOVE THE
FLOOR IN
PRIVATE GARAGES
Narrow wall bracing
fully sheathed with front door being
moved forward 12"
to get within 4' of front wall
----------------------------------------------------------------------------
Other Fees . . .
. . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
Charged Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
499.00 499.00
.00
.00
Plan Check Total
.00 .00
.00
.00
Other Fee Total
750.00 750.00
.00
.00
Grand Total
1249.00 1249.00
.00
.00
--------------------------------------------- - ---------- ----------------
BUILDING DEPT REPRE NTATIVE:
APPLICANT:��„��
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 • FAX,: (979) 764-3496
----------------------------------------------------------------------------
Application Number . . . . .
06-00000703 Date
3/13/06
Property Address
. . . . . .
3807 RANSBERG CT
Property ID:
244030-0613-0040
R #:
R301755
Application type
description
TEMP POLE
Subdivision Name
. . . . . .
EDELWEISS GARTENS PH 6
Property Use . .
. . . . . .
RESIDENTIAL
Property Zoning .
. . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
EDELWEISS GARTEN
VENTURE
------------------------
HERMAN E COUCH - BUILDER
311 CECILIA LOOP
HERMAN E COUCH
COLLEGE STATION
TX 778456310
1282 STAUFFER CIRCLE
COLLEGE STATION
TX 77845
(979) 690-7813
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. BK
Permit Fee . . .
. 20.00
Issue Date . . .
. 3/13/06
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid Credited
------------------------------
Due
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
BUILDING DEPT REPRE ENTATIVE:
APPLICANT: ����,
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840 '
CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX
Planning d Development Services
WWW.CSTX.GOV
ADDRESS//BLOCK
LOCATION:
LOT �
BUSINESS/OWNER NAME:
CONTRACTOR/HOMEOWNERZAC� /�,_4. _� "
For Office Use Only
r OATEN C REG
APPLICATION #
TEMP POLE
PHONE:
PHONE: 2 A
CONTRACTOR ADDRESS: 2r, 6'11 ��a,�%_p•?� ` ,, ' J��
ELECTRICIAN: PLUMBER:w-I
HVAC: ax(v GOOD CENTS (Resider(al only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Ashtos Survey) EW CONSTRUCTION • SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION" SWIMMING POOL
Required)
DESCRIPTION OF WORK: /)U.Ir.V-�
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
/j TEXAS ACCESSIBILITY STANDARD AS) PROJECT REGISTRATION# EABPRJ ` VALUATION: $ s DO TOTAL AREA:o� HEATED AREA-./ 2&
(Cost of La or and Materials)
FI PUBLIC SEWER
�} SEPTIC/TREATMENT SYSTEM
1``(b rS
� EWER TAP:
/�J SIZE
WATER TAP:
SIZE
OTHER TAP:
SIZE
P_tEMP POLE
GARAGE TYPE: SINGLE El
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS
INTERIOR WALL TYPE
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE TRIPLE
ATTACHED F-1 DETACHED a CARPORT
a
SIGNATURE OF APPLICANT: Z fj,�_i �0;-af
*If proposed work involves new comme al construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
3--9-o6
Plans Examiner
rj(f� , stove
IZn
Zoning Official
C,c.W4 4704 �a�,wht/
goWenits:
YES r NO
Energy Code Compliance Information
% Glazing- of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating