HomeMy WebLinkAbout06-692WF0752080 / 001 City of College Station
PAGE
REQ. DATE:
03/10/06
03/10/06
15:43:04
LOCATION:
2000 MOSES CREEK CT
�' ' ' LOC ID:
201550
REQUESTOR:
H L C HOMES
ORIGIN: CUSTOMER -WALK IN
REQ. USER:
BKORTHAUER AUTH. USER:
BKORTHAUER WORK TYPE:
ROUT
3/4" WATER
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET READY
SCHED START:
03/10/06 SCHED
COMPLETION:
03/10/06
********************************************************************************
JOB ORDER RESULT COMMENTS
City of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . . 4/18/07
Parcel Number . . . . . - -
Property Address . . . 2000 MOSES CREEK CT
COLLEGE STATION TX 77845
Subdivision Name . . . WILLIAMS CREEK PH 1
Legal Description . . . WILLIAMS CREEK PH 1
BLOCK 2
LOT 9
Property Zoning . . . . RURAL RESIDENTIAL SUB.
Owner . . . . . . . . .
Contractor . . . . . . H L C HOMES LLC
979 696-9049
Application number 06-00000692 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX
Flood Zone . . . . . .
Approved . . . . . . . xu.
Buildi g Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
Nicole Cochran - Re: Calling for C.O. @ 2000 Moses Creek Ct. Page 1
From:
Paul Schoenfeld
To:
Benjamin McCarty; Chris Haver; Gina Southerla...
Date:
3/8/2007 8:13 am
Subject:
Re: Calling for C.O. @ 2000 Moses Creek Ct.
ALL OK.
PAUL
>>> Gina Southerland 3/8/2007 8:12 AM >>>
BP# 06-1033
Gina Southerland
CSR - Planning & Development Services
City of College Station
979-764-3570
www.cstx.4ov
SEP. 7,2006 3:58PM Brazos County Health Department N0,1898 P. 2
Brazos County Health Department
201 North Texas Ave.
Bryan, TX 77803-5317
(979) 361-4440
LICENSE TO OPERATE AN ON SITE SEWAGE FACILITY
THIS IS TO CERTIFY that the on site sewage facility owned by:
HLC HOMES
MOSES CREEK 2000, College Station TX 77845
WILLLIAMS CREEK
OSSF #: 2006 - 4048
Grid:
Block: 2 Lot: 9 Certificate of Compliance: IN C.S.
Installed By: HEATH, JAMES - HEATH'S BACKHOE SERVICE
Engineered By: PICKENS ENVIRONMENTAL SERVICE
Date Purchased: 9/1/2006 Final Inspection Date: 9/7/2006
Disinfectant: Chlorine
Bedrooms: 4
Employees: 0
MaxGPD: 319
The private sewage facility licensed above was installed according to the current and
minimum guidelines of the Texas Commission on Environmental Quality (TCEQ) and
Brazos County.
This aerobics stem with s ra di ersal requires a disinfectant for final treatment of the
sprayed effluent. It is the responsibility of the homeowner to monitor the disinfectant
and to add more when needed. (Swimming pool chlorine tablets are not acceptable
substitutes). Under no circumstance are any food crops or edible foods to be grown in
the spray area. Mowing of the sprayfield on a regular basis should also be done to help
with the evaporation process.
The current maintenance contract for this system will expire 2-years from the above final
inspection date. A new maintenance contract must be in force at that time, and a copy of
the new contract filed with this office 30 days before contract expires.
This is a NON -TRANSFERABLE license. Upon transfer of ownership, the new owner
shall be required to transfer the original license into his/her name. Should the system
malfunction in the future, it will be the licensee's responsibility to bring the system in
compliance with all current state and county regulations.
This license does not extend to the material's, workmanship, or fabrication, of the
system, so as to expressly or impliedly grant the owner, or installer of the system any
warranty by / or rights against Brazos County and / or the Brazos County Health
Department, as to the quality or durability of the system, nor compliance with licensee's
individual specifications and requirements, but solely relates to the system meeting the
requirements of the above named regulatory body in effect as of this date.
FINAL OSSF INSPECTION APPROVED 917106 BY MSADA Y —�
(WITH IN CITY LIMITS OF COLLEGE STATION, Tx)
CLEAR ALL UNDERGROWTH/ TREES WITHIN 10 FT OF SPRAY NOZZLES II
R-10
1�lrwment,l aclatiet
WF0753817 / 001 City of College Station PAGE 1
REQ. DATE: 03/20/06 C,� -(_CqdD3/20/06 8:48:35
LOCATION: 2000 MOSES CREEK CT LOC ID: 201550
REQUESTOR: H L C HOMES ORIGIN: CUSTOMER -WALK IN
REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/20/06 SCHED COMPLETION: 03/20/06
********************************************************************************
JOB ORDER RESULT COMMENTS
BUILDING PERMIT
CITY OF COLLEGE STATION`
1101 TEXAS i AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00000692 Date 3/10/06
Property Address . . . . . . 2000 MOSES CREEK CT
Property ID: - -
R #: R*****
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . RURAL RESIDENTIAL SUB.
Application valuation . . . . 174000
Owner Contractor
------------------------ ------------------------
H L C HOMES LLC
LEON COUCH
PO BOX 735
CALDWELL TX 77836
(979) 696-9049
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 3.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2594.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE SEPTIC
TAZ 329.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . BK
Permit Fee . . . . 682.00 Plan Check Fee .00
Issue Date . . . . 3/10/06 Valuation . . . . 174000
Expiration Date . . 9/06/06
Qty Unit Charge Per Extension
BASE FEE 460.00
74.00 3.0000 THOU BLDG, VAL 100001-500000 222.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
BUILDING DEPT REPRESENTATIVE:
APPLI
BUILDING PERMIT
CITY OF COLLEGE STATION'
1101 TEXAS ,AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
Page 2
Application Number . . . . . 06-00000692 Date 3/10/06
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
OBTAIN HEALTH DEPARTMENT APPROVAL: CALL 979-361-4440 FOR
MORE INFORMATION. SEPTIC SYSTEMS INSTALLED
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
---------7------
BUILDINC
APPLICAT
BUILDING PERMIT
CITY OF COLLEGE STATION'
1101 TEXAS-AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number
06-00000692
Page 3
Date 3/10/06
Special Notes and Comments
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
15" Culvert required for driveway
Narrow wall bracing fully sheathed
--------------------------------- - ----- -----------------
41-
BUILDING DEPT REPRESENTATIVE:�7
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION*
1101 TEXAS-AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number
. . . . .
06-00000692
Date 3/10/06
----------------------------------------------------------------------------
Other Fees . . . .
. . . . .
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid
----------
Credited
----------
Due
----------
Permit Fee Total
682.00
682.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
400.00
400.00
.00
.00
Grand Total
1082.00
1082.00
.00
.00
-------------------
BUILDING DE
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION'
1101 TEXAS-AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00000693 Date 3/10/06
Property Address . . . . . . 2000 MOSES CREEK CT
Property ID: - -
R #: R*****
Application type description TEMP POLE
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . RURAL RESIDENTIAL SUB.
Application valuation . . . . 0
Owner
Contractor
------------------------
------------------------
H L C HOMES LLC
LEON COUCH
PO BOX 735
CALDWELL
TX 77836
(979) 696-9049
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. BK
Permit Fee . . .
. 20.00
Issue Date . . .
. 3/10/06
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
------------------------------------------------
BUILDING DEPT REPRESENTATIVE: !--7 i
APPLICANT:
----1-------------------
For off —Us OMy
v
APPLICATION FOR BUILDING PERMIT DATE tj
CITY OF COLLEGE STATIbN APPLICATION X
C3 1101 TEXAS AVENUE f 0
COLLEGE STATION, TX 77840 TEMP POLE
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US
p00
ADDRESS/LOCATION: M
LOT BLOCK �! SUBDI�V) - ���EC/PH /
VISION 1 - �:> 4-4�/�
BUSINESS/OWNER NAME: ,L. C ,2nn" �dJG - PHONE: (0�CL- -90��
CONTRACTOR/HOMEOWNER: PHONE:
CONTRACTOR ADDRESS: E,,, „� D3 1i C A�d w
ELECTRICIAN:
HVAC:
PLUMBER:
GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL
Required)
DESCRIPTION OF WORK: PL. t 4 a>":�
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PF�tOJECT REGISTRATION# EABPRJ
VALUATION: $ 17 L% , DJO 170
TOTAL AREA HEATED AREA -
(Cost of Lab6r and Materials)
/ PUBUC SEWER NUMBER OF BEDROOMS:
(Q ® SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
❑ SEWER TAP:
SVE
� WATER TAP: 31)4
SIzE
OTHER TAP:
_ Sim
�S TEMP POLE ^ c L 1
ff� GARAGE TYPE: SINGLE a
,1 ATTACHED
SIGNATURE OF APPLI
INTERIOR WALL TYPE: 2X 4z
EXTERIOR WALL TYPE: ,
FOUNDATION TYPE:
ROOF TYPE: '
DOUBLE a TRIPLE
IETASHED a SAaEow
♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦s-s—♦♦4♦♦♦♦♦♦♦♦i♦♦♦♦♦♦♦♦♦♦♦♦
;T--6 y , —'O
✓ iS "' CvlVeAf
Official Use Only
♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦
Comments:
E rN0
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)v
Insulation R value of ceiling 2 (vaulted areas/no attic)
t 9
Glazing SHGC
�b
Glazing U-Factor
R value of ductwork
A/C SEER rating
r
,ram ;`1� ' •S .
S
`r
CITY OF COLLEGE STATION
Planning 6-Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLAN REVIEW/PERMIT NUMBER# a
_ OA
DATE: -3/ 9 / o6
BUILDING ADDRESS: aleoo
M13see,<
I. Foundation Requirements
NAIMV
A.
Concrete minimum f'c of 3000 PSI
B.
Minimum four 4 inch slab thickness
C.
Vapor barrier
1. 6 mil poly
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E.
Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F.
Wood foundation details indicated
A
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A.
Girder or sill dimensions, grade & species
B.
Floor joist size, spacing, grade & direction of span indicted on plans
C.
Treated sill plate or bottom plate
D.
Narrow Wall Bracing Methods indicated on plans
E.
Header sizes indicated on plans
F.
Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G.
Operable bathroom window required when mechanical ventilation is not provided
H.
Stud grade andspacing
I.
Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, grade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M.
N.
Span exceeding code tables must be engineered
Rafters sizes, spacing, rade, slope and purlins if required.
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
Planning & Development Services
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NA/
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements
K
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6" inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated on plans)
NA/
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Mason fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than an portion of the buildingwithin ten 10 feet horizontal
(*hrq"
CITY OF COLLEGE STATION
Planning & Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
V. Electrical Service Requirements
N
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector location(s) indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
NA/
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
VIII. Energy Requirements
NAYOK
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N K
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
NA/fV
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side (intersecting) street
Subdivision Regulations — Ordinance 690
NAB
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
K
Does not block any water course or divert any flow
Elevation certificate if required
P_V_
CITY OF COLLEGE STATION
Planning er Development Services
Comments:
LANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
DATE
s--: 14
MECcheck Compliance Report
2000 IECC
MECcheck Software Version 3.2 Release lb
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 03/07/06
DATE OF PLANS: March 7, 2006
PROJECT INFORMATION:
2000 Moses
Lot 9; Blk 2
Williams Creek Phase I
COMPANY INFORMATION:
HLC Homes, Inc.
203 Hwy 21 West
Caldwell, Texas 77836
COMPLIANCE: Passes
Permit Number
Checked By/Date
Maximum UA = 693
Your Home = 590
14.9% Better Than Code
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor
UA
Ceiling 1: Flat Ceiling or Scissor Truss
4081
30.0
0.0
143
Wall 1: Wood Frame, 16" o.c.
2594
13.0
6.0
128
Window 1:
Metal Frame with Thermal Break, Double Pane with Low-E
348
0.640
223
Door 1: Glass
150
0.640
96
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the peW application. The proposed building has been
designed to meet the g000 IECC requirements in MECche ersion 3.2 Release lb.
,?` 7- 00
MECcheck Inspection Checklist
2000 IECC
MECcheck Software Version 3.2 Release 1 b
DATE: 03/07/06
Bldg.
Dept.
Use
Ceilings:
1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
Above -Grade Walls:
1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity + R-6.0 continuous insulation
Comments:
Windows:
1. Window 1: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.640
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
1. Door 1: Glass, U-factor: 0.640
# Panes Frame Type
Comments:
Thermal Break? [ ] Yes [ ] No
[ ] I The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
I values must be determined in accordance with the NFRC test procedure or taken from the default table.
I
Air Leakage:
[ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air
I leakage must be sealed.
[ ] I Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate
I air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation.
I
Materials Identification:
[ ] I Materials and equipment must be installed in accordint to the manufacturer's installation instructions.
[ ] I Materials and equipment must be identified so that compliance can be determined.
[ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating
I equipment must be provided.
[ ] I Insulation R-values and glazing U-values must be clearly marked on the building plans or specifications.
I
Duct Insulation:
[ ] I Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
I Duct Construction:
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
I (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at
I less than 2 in. w.g. (500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] Air filters are required in the return air system.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 °F or chilled fluids below 55 OF must be insulated to the
I levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in
Inches by Pipe Sizes
Heated Water
Non -Circulating
Runouts
Circulating
Mains and Runouts
Temperature ( F)
Up to 1„
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)