HomeMy WebLinkAbout06-668PREPARED 8/17/06, 6:36:21 INSPECTION TICKET PAGE 3
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/16/06
------------------------------------------------------------------------------------------------
ADDRESS . : 8427 LAUREN DR SUBDIV: NORTH FOREST
CONTRACTOR DOUBLE D HOMES, LLC PHONE (979) 778-3199
OWNER MUCO VERDE, LLC PHONE
PARCEL 222222-0003-0140
APPL NUMBER: 06-00000668 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/10/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00
4/10/06 AP T/S: 04/10/2006 10:22 AM GLSOUTH -----------------------
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 5/16/06 OC BLDG, FRAMING TIME: 17:00
5/17/06 AP May 17, 2006 9:50:23 AM kwolfe
May 17, 2006 11:07:09 AM kwolfe
B130 01 5/22/06 BH BLDG, INSULATION TIME: 17:00
5/22/06 AE May 22, 2006 3:13:07 PM bkorthauer
May 22, 2006 3:13:22 PM bkorthauer
SEAL ALL EXTERIOR WALL "T" & CORNER BEAMS
B121 01 8 16/06 BI BLDG, FINAL TIME: 17:00
eal August 16, 2006 3:35:15 PM kwolfe
------------------------ 1�----------- COMMENTS AND NOTES --------------------------------------
a ��
Date: 8/17/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 668
Address: 8427 LAUREN DR
Type
Inspection Type Code
Status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
Strings On Setbacks O.K.
B100
BLDG, FOUNDATION -SLAB
IC
Slab Ground Installed
B115
BLDG, FRAMING
IC
May 17, 2006 11:07:09 AM kwolfe
B130
BLDG, INSULATION
IC
May 22, 2006 3:13:22 PM bkorthauer
B130
BLDG, INSULATION
IC
SEAL ALL EXTERIOR WALL "T" & CORNER BEAMS
Page 1
WF0756586 / 001 City of College Station PAGE 1
REQ. DATE: 03/30/0603/30/06 14:40:58
LOCATION: 8427 LAUREN DR "` LOC ID: 200278
REQUESTOR: DOUBLE D HOMES ORIGIN: CUSTOMER -WALK IN
REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/30/06 SCHED COMPLETION: 03/30/06
********************************************************************************
JOB ORDER RESULT COM 4KNTS
Brittany Korthauer - Insulation request inspection result, 8427 Lauren Dr. #06-668 1
From: Brian Henry
To: Southerland, Gina
Date: 5/22/2006 3:00 pm
Subject: Insulation request inspection result, 8427 Lauren Dr. #06-668
CC: Korthauer, Brittany; Wolfe, Kim
Print for file
Inspected insulation, 8427 Lauren Dr. #06-668, Double D Homes, 5-22-06
Inspection result, Inspected OK for Good Cents
Notes:
Seal all exterior wall "T" & corner beams
WF0755904 / 001 City of College Station PAGE 1
REQ. DATE: 03/28/06 r 0 03/28/06 8:56:09
LOCATION: 8427 LAUREN DR LOC ID: 200278
REQUESTOR: DOUBLE D HOMES ORIGIN: CUSTOMER -WALK IN
REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT
4" SEWER TAP AND 3/4" WATER TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/28/06 SCHED COMPLETION: 03/28/06
********************************************************************************
JOB ORDER RESULT COM UUTrS
BUILDING PERMIT
CITY O&. _�EGE STATION
1101 TEXAS ` AVE
COLLEGE STATION,- TX 77840
PHONE: (979)764-3570. FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 06-00000668 Date 3/28/06
Property Address . . . . . . 8427 LAUREN DR
Property ID: 222222-0003-0140
R #: R*****
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 135000
Owner Contractor
------------------------ ------------------------
MUCO VERDE, LLC DOUBLE D HOMES, LLC
1305 W VILLA MARIA 4037 AUSTIN'S LANDING
BRYAN TX 77801 BRYAN TX 77808
(979) 778-3199
--- Structure Information 000 000 SINGLE FAMILY
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1718.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 299.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . BK
Permit Fee . . . . 565.00 Plan Check Fee .00
Issue Date . . . . 3/28/06 Valuation . . . . 135000
Expiration Date . . 9/24/06
Qty Unit Charge Per Extension
BASE FEE 460.00
35.00 3.0000 THOU BLDG, VAL 100001-500000 105.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
BUILDING DEPT RE T,�fIIVE: `
/,
APPLICANT:
BUILDING PERMIT
CITY OF. COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000668
Page 2
Date 3/28/06
Special Notes and Comments
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
----------------- ---------- -- ------
BUILDING DEPT REP SE- IS7 AT
APPLICANT:
BUILDING PERMIT
CITY OF. COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 06-00000668 Date 3/28/06
----------------------------------------------------------------------------
Special Notes and Comments
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Narrow wall bracing by Prescriptive Methods of 41X8' OSB
and 32" Alternate braced wall on right side of garage.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" 350.00
WATER TAP 3/4" 400.00
--------------------------- ---------- - -----------------------------
BUILDING DEPT RE 'ES `TAT- E :
APPLICANT: / /�
BUILDING PERMIT
CITY OF.COLEEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number
. . . . .
06-00000668
Date 3/28/06
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid
----------
Credited
----------
Due
----------
-----------------
Permit Fee Total
565.00
565.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1315.00
1315.00
.00
.00
---------------------------- ----------- -- -------------
BUILDING DEPT RE --E �T E J
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF.COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID:
R #•
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
06-00000669
8427 LAUREN DR
222222-0003-0140
R*****
TEMP POLE
Date 3/28/06
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner
Contractor
------------------------
MUCO VERDE, LLC
------------------------
DOUBLE D HOMES, LLC
1305 W VILLA MARIA
4037 AUSTIN'S LANDING
BRYAN
TX 77801
BRYAN
TX 77808
(979) 778-3199
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. BK
Permit Fee . . .
. 20.00
Issue Date . . .
. 3/28/06
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
20.00
-20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
-
------------------ - -
---- -------------- ------�--- -- ------------
BUILDING DEPT R R ENT IVE:
APPLICANT:
(*tl""
CITY OF COLLEGE STATION
PGtnnind & Developmmt Serwnr
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWWW.CSTX.GOV
ADDRES�S/LO ATION:_ C'`1 2 % L-AV (ZCN L
LOT l(l ' BLOCK
SUBDIVISION A-'OR-►'rf
f =z>&LqS i
For Office Use Only
DAT C-REG� y�
APPLICATION # lY
TEMP POLE # 9
SEC/PH
BUSINESS/OWNER NAME: �L. Duf3c.JJ L� H-D IM ft } PHONE: -7 —7
4
CONTRACTOR/HOMEOWNER: M Lr PHONE: ',�IL 2 V
CONTRACTOR ADD
IRESS: 2$y T"W% 1 I—) 9 'is IX C 1(Sti , -ty -7 -7 �3 v $
ELECTRICIAN: G d w e—L ems" PLUMBER: '�-A Cl�— w
HVAC: W` AS To"- 4'-) GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION* SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK: 5
PROPOSED USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ /3 SO 0-0 ,' TOTAL AREA: � HEATED AREA: I-1 113
(Cost of Labor and Materials)
19 PUBLIC SEWER
//��❑ SEPTIC/TREATMENT SYSTEM
KSEWER TAP:
Itz WATER TAP:
OTHER TAP:
TEMP POLE
GARAGE TYPE:
SIZE
3/
SIZE
NZE
SINGLE EJ
ATTACHED
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE � TRIPLE
DETA�D� �,CARPOR
SIGNATURE OF APPLICANT:i� U(-
*If proposed work involves new corn erclal construction or facade improvements/renovations to an existing
commercial property, building elevations are required.
Official Use Only
,:a '?' Imo(
Plans Examiner Zoning Official
e,w� tear r(0°
ents:
ppurc iol ve— TA0-G 9 � (,r YE r NO
32-" A(�• �-,4 14. sfk
0 rF 60'U'1;'e
Fire Marshall
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
L-S75 Cc�
1-t4
t
3Z) ✓
36
-7 /
� 1
R
Iwt; L�# � M•- �Y �
CITY OF COLLEGE STATION
Planning d' Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLAN REVIEW/PERMIT NUMBER# 06�Q� g DATE: 3 A /o �
BUILDING ADDRESS: !�q A-2 z-Avaed &
I. Foundation Requirements
NAItSo
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four (24) inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing plan or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
t
'4
(*hrq5*
CITY OF COLLEGE STATION
Planning d Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NA/
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half (9-1/2) inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6") inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements (to be indicated on plans)
NA/
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
CITY OF COLLEGE STATION
Planning 6 Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
V. Electrical Service Requirements
NAIKW
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
Vil. Mechanical Requirements
NA/
K
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
NA/
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
NA/
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
T_
I.,
Subdivision Regulations — Ordinance 690
NA/
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
AWOK
Does not block any water course or divert any flow
Elevation certificate if required
(�
CITY OF COLLEGE STATION
Planning c3 Development Services
Comments:
PLANS EXAMINER
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
3-I-0�
DATE
REScheck Compliance Certificate
2000 IECC
RES check Software Version 3.5 Release le
Data filename: C:\Program Files\REScheck\8427 Lauren.rck
PROJECT TITLE: 8427 Lauren
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 03/07/06
DATE OF PLANS: 2/15/06
PROJECT DESCRIPTION:
8427 Lauren
College Station, TX
DESIGNER/CONTRACTOR:
Double D Homes
JECT N S:
14 percent fenestration
Front door exempted as allowed
COMPLIANCE: Passes
Maximum UA = 578
Your Home UA = 474
18.0% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0 36
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.36
Door 4: Glass
SHGC: 0.36
Wall 4: Wood Frame, 16" o.c.
Door 3: Solid
Floor 1: Slab -On -Grade -.Unheated
Insulation depth: 0.0'
Permit Number
Checked By/Date
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
1718 30.0
0.0
60
1384 13.0
5.4
74
187
0.670 125
20
0.670 13
214 13.0
0.0
16
20
0.150 3
176
0.0
183
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
)AI!
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in RES checkVers' n 3. Relea I (formerly MECchec� and to comply with the man atory requirements listed in
the REScheckInspection klis
Budder/Designer Date / ICJ