HomeMy WebLinkAbout06-657PREPARED 6/29/06, 12:08:25 INSPECTION TICKET PAGE 21
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/29/06
------------------------------------------------------------------------------------------------
ADDRESS . : 116 WALCOURT LOOP SUBDIV: EDELWEISS GARTENS PH 9
CONTRACTOR CHARLES THOMAS HOMES, INC. PHONE (979) 696-4384
OWNER . . PHONE
PARCEL . . 244030-0927-0090
APPL NUMBER: 06-00000657 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------- -----------------------------------------------------------------------------------
00-01 T3/21/06 JGM BLDG, FOUNDATION -SLAB TIME: 17:00
3/21/06 AP March 21, 2006 11:33:10 AM kwolfe
Strings On Setbacks O.K.
Slab Ground Installed
B115 01 4/19/06 OC BLDG, FRAMING TIME: 17:00
4/19/06 DP April 19, 2006 8:24:19 AM bkorthauer
early afternoon
Garage APA Portal Framing Incorrect
Need To Add Windbracing
j Loose Or Missing Anchor Bolt Nuts
B17 5 02 4/20/06 OC BLDG, FRAMING TIME: 17:00
tt 4/20/06 AP April 20, 2006 8:28:47 AM kwolfe
B130 01 4/26/06 BH BLDG, INSULATION TIME: 17:00
4/26/06_ AP April 26, 2006 8:34:30 AM bkorthauer
April 26, 2006 8:34:35 AM bkorthauer
B125 01 6/ 9/0 BI BLDG, FINAL TIME: 17:00
June 29, 2006 9:56:43 AM glsouth
-------------------------------------- COMMENTS AND NOTES --------------------------------------
t &&-I -;t;ts (4l
b6_�1S 5
D
Brittan Korthauer - Insulation request ins ection result, 116 Walcourt, #06-657 Page 1
Y P ,
From: Brian Henry
To: Southerland, Gina
Date: 4/25/2006 4:35 pm
Subject: Insulation request inspection result, 116 Walco #06-657
CC: Korthauer, Brittany; Wolfe, Kim
Print for file
Inspected insulation, 116 Walcourt, #06-657, Thomas Homes, 4-25-06
Inspection result: Inspected OK for Good Cents
i
WF0753049 / 001 City of College Station , PAGE 1
nra1-1 r�Tmra _ nn /-1 r_ /n - 66 V' 5Q n - I I _ I
LOCATION: 116 WALCOURT LOOP LOC ID: 203540
REQUESTOR: CHARLES THOMAS ORIGIN: CUSTOMER -WALK IN
REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/15/06 SCHED COMPLETION: 03/15/06
********************************************************************************
JOB ORDER RESULT COMVf TTS
(*hrq"
CITY OF COLLEGE STATION
Planning 6- Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLAN REVIEW/PERMIT NUMBER# _ S DATE: 3 / 7 /
BUILDING ADDRESS: 1, a ,Id-4 L-eo
I. Foundation Requirements
NA/
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings (30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N OK
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four (24) inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
CITY OF COLLEGE STATION
Planning 6-Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
N Ar
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
AIA
111. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6'-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6") inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4) inch sphere
IV. Fireplace Requirements (to be indicated on plans)
NA/
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10 feet horizontal
(*hrq"
CITY OF COLLEGE STATION
Planning d' Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
V. Electrical Service Requirements
NA(M)
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
NA(OK)
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VI1. Mechanical Requirements
N
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
N
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N O
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
hAtM
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
NA/09
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
OK
Does not block any water course or divert any flow
Elevation certificate if required
CITY OF COLLEGE STATION
Planning d Development Services
Comments:
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
3--7
PLANS EXAMINER DATE
S 1 , t-: ?Lwa -
L9jf3�.1- E��IwEi� Gars-Phs9
� D 1AIa9 co uf.,-r LoD, p
�R
CHARLES THOMAS HOMES, INC.
P.O. BOX 10106
COLLEGE STATION, TX 77842
PLAIN 19 D9 5CALf- . 1'=1-b
MECcheck Compliance Report
2000 IECC
MECcheck Software Version 3.2 Release lb
TITLE: College Station Building Permits
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 02/27/06
DATE OF PLANS: 03/01/2006
PROJECT INFORMATION:
116 Walcourt Loop - Edlws Grtns 9
COMPANY INFORMATION:
Charles Thomas Homes, Inc
COMPLIANCE: Passes
Maximum UA = 774
Your Home = 546
29.5% Better Than Code
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame, Double Pane with Low-E
Door 1: Solid
Door 2: Solid
Door 3: Glass
Slab 1: Unheated, 0.0' insul.
Air Conditioner 1: Electric Central Air, 14 SEER
Furnace 1: Forced Hot Air, 80 AFUE
Permit Number
Checked By/Date
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
1909 0.0
30.0
59
1743 15.4
0.0
113
198
0.640
127
20
0.013
0
18
0.013
0
18
0.440
8
229
0.0
239
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building
plans, specifications, and other calculations submitted with the permit application. The proposed building has
been designed to m t 2000 IECC require n MECcheck Version 3.2 Release 1 .
Builder/Designer ate i 200 (p
CHARLES THOMAS HOMES, INC.
P.O. BOX 10106
COLLEGE STATION, TX 77842
WF0751162 / 001 City of College Station
PAGE 1
REQ. DATE: 03/07/06 `� 03/07/06 15:31:16
LOCATION: 116 WALCOURT LOOP LOC ID: 203540
REQUESTOR: CHARLES THOMAS HOMES ORIGIN: CUSTOMER -WALK IN
REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT
4" SEWER TAP AND 3/4" WATER TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/07/06 SCHED COMPLETION: 03/07/06
********************************************************************************
JOB ORDER RESULT COMVIENTS
BUILDING PERMIT
...,.-CITY OF COLLEGE STATION
1101 AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
------------------------------------- i--------------------------------------
Application Number . . . . . 06-00000657 Date 3/07/06
Property Address . . . . . . 116 WALCOURT LOOP
Property ID: 244030-0927-0090
R #•
Application type description RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . .
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 130000
Owner
Contractor
------------------------
------------------------
CHARLES THOMAS HOMES,
INC.
CHARLES THOMAS
P 0 BOX 10106
COLLEGE STATION
TX 77842
(979) 696-4384
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1909.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
TAZ
405.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
BK
Permit Fee . . . .
550.00 Plan Check Fee
.00
Issue Date . . . .
3/07/06 Valuation . .
. . 130000
Expiration Date . .
9/03/06
Qty Unit Charge
Per
Extension
BASE FEE
460.00
30.00 3.0000
THOU BLDG, VAL 100001-500000
90.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
-------------------
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000657
Page 2
Date 3/07/06
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
BUILDING D
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number
06-00000657
Page 3
Date 3/07/06
Special Notes and Comments
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
Fully sheathed with Interior anchor bolts and bracing in
master bedroom.
----------------------------------------------------------------------------
-----Other Fees .---------------SEWER-TAP-4" N350.00
----------2-----A_"------------------
BUILDING DEPT R$'PRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 4
Application Number
. . . . .
06-00000657
Date 3/07/06
----------------------------------------------------------------------------
Other Fees
-
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
--------------------
Due
----------
-----------------
Permit Fee Total
550.00
550.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1300.00
1300.00
.00
.00
-------------------
BUILDING DE
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID:
R #.
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
06-00000658
116 WALCOURT LOOP
244030-0927-0090
TEMP POLE
Date 3/07/06
RESIDENTIAL
SINGLE FAMILY RESIDENTIAL
0
Owner
Contractor
------------------------
------------------------
CHARLES THOMAS HOMES,
INC.
CHARLES THOMAS
P O BOX 10106
COLLEGE STATION
TX 77842
(979) 696-4384
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. BK
Permit Fee . . .
. 20.00
Issue Date . . .
. 3/07/06
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
---------------------------------------------
BUILDING DEPT RFIPRESENTATIVE:
APPLICANT:
- - - - - - - - - - - - - - - - - - - - -
f550 =
4 35o -
ME
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3670 (979) 764-3496 FAX
W W W.CI.COLLEG E-STATION.TX.US
ADDRESS/LOCATION: l
LOT V BLOCK a-)- ✓ SUBDIVISION
DATE: V rW^ D W
APPLICATION # 00
TEMP POLE * '
SEC/PH ✓ /
BUSINESS/OWNER NAME: PHONE:
CHARLES THOMAS HOMES, INC.
CONTRACTOR/HOMEOWNER: pa BG1Y 10106 PHONE:
CO TR
f' ACTOR'ADDRESS: COLLEGE STATION, TX 77842
ti
ELECTRICIAN:; ��� PLUMBER: '.1. C
HVAC:2QMtoe-71 CENTS (Residential onl E
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION ',MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION• SWIMMING POOL
Required)
DESCRIPTION OF WORK: 4Ln5
TEXAS ACCESSIBILI STANDARD (fAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 140 TOTAL AREA: HEATED AREA: D
(Cost of Labor and Materials) g
Tf PUBLIC SEWER NUMBER OF BEDROOMS:_
SEPTIC/TREATMENT SYST M NUMBER OF BATHROOMS:
SEWER TAP: , INTERIOR WALL TYPE:
E
r`WATER TAP: / (I EXTERIOR WALL TYPE:
tIZIE
OTHER TAP: FOUNDATION TYPE:
SIZE
TEMP POLE ROOF TYPE:
I [05 GARAGE TYPE: SINGLE DOUBLE TRIPLE a
ATTACHED DETACHED CARP F7
SIGNATURE OF APPLICANT: *If proposed proposed work involves new commercial construction or eimpr`ove nts/renovations to an existing
commercial property, building elevations are required.
Official Use Only OwMents
Y or NO
fll�
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1(flat areas)
Insulation R value of ceiling 2 (vaulted areastno attic)
NIA
Glazing SHGC
/
Glazing U-Factor
R value of ductwork
A/C SEER rating