HomeMy WebLinkAbout06-657PREPARED 6/29/06, 12:08:25 INSPECTION TICKET PAGE 21 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/29/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 116 WALCOURT LOOP SUBDIV: EDELWEISS GARTENS PH 9 CONTRACTOR CHARLES THOMAS HOMES, INC. PHONE (979) 696-4384 OWNER . . PHONE PARCEL . . 244030-0927-0090 APPL NUMBER: 06-00000657 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------- ----------------------------------------------------------------------------------- 00-01 T3/21/06 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 3/21/06 AP March 21, 2006 11:33:10 AM kwolfe Strings On Setbacks O.K. Slab Ground Installed B115 01 4/19/06 OC BLDG, FRAMING TIME: 17:00 4/19/06 DP April 19, 2006 8:24:19 AM bkorthauer early afternoon Garage APA Portal Framing Incorrect Need To Add Windbracing j Loose Or Missing Anchor Bolt Nuts B17 5 02 4/20/06 OC BLDG, FRAMING TIME: 17:00 tt 4/20/06 AP April 20, 2006 8:28:47 AM kwolfe B130 01 4/26/06 BH BLDG, INSULATION TIME: 17:00 4/26/06_ AP April 26, 2006 8:34:30 AM bkorthauer April 26, 2006 8:34:35 AM bkorthauer B125 01 6/ 9/0 BI BLDG, FINAL TIME: 17:00 June 29, 2006 9:56:43 AM glsouth -------------------------------------- COMMENTS AND NOTES -------------------------------------- t &&-I -;t;ts (4l b6_�1S 5 D Brittan Korthauer - Insulation request ins ection result, 116 Walcourt, #06-657 Page 1 Y P , From: Brian Henry To: Southerland, Gina Date: 4/25/2006 4:35 pm Subject: Insulation request inspection result, 116 Walco #06-657 CC: Korthauer, Brittany; Wolfe, Kim Print for file Inspected insulation, 116 Walcourt, #06-657, Thomas Homes, 4-25-06 Inspection result: Inspected OK for Good Cents i WF0753049 / 001 City of College Station , PAGE 1 nra1-1 r�Tmra _ nn /-1 r_ /n - 66 V' 5Q n - I I _ I LOCATION: 116 WALCOURT LOOP LOC ID: 203540 REQUESTOR: CHARLES THOMAS ORIGIN: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/15/06 SCHED COMPLETION: 03/15/06 ******************************************************************************** JOB ORDER RESULT COMVf TTS (*hrq" CITY OF COLLEGE STATION Planning 6- Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS PLAN REVIEW/PERMIT NUMBER# _ S DATE: 3 / 7 / BUILDING ADDRESS: 1, a ,Id-4 L-eo I. Foundation Requirements NA/ A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings (30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements N OK A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four (24) inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. CITY OF COLLEGE STATION Planning 6-Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. N Ar 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes AIA 111. Stairway Requirements OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6") inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4) inch sphere IV. Fireplace Requirements (to be indicated on plans) NA/ A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal (*hrq" CITY OF COLLEGE STATION Planning d' Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS V. Electrical Service Requirements NA(M) A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements NA(OK) A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VI1. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements N A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N O Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements hAtM Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 NA/09 Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required CITY OF COLLEGE STATION Planning d Development Services Comments: PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS 3--7 PLANS EXAMINER DATE S 1 , t-: ?Lwa - L9jf3�.1- E��IwEi� Gars-Phs9 � D 1AIa9 co uf.,-r LoD, p �R CHARLES THOMAS HOMES, INC. P.O. BOX 10106 COLLEGE STATION, TX 77842 PLAIN 19 D9 5CALf- . 1'=1-b MECcheck Compliance Report 2000 IECC MECcheck Software Version 3.2 Release lb TITLE: College Station Building Permits CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 02/27/06 DATE OF PLANS: 03/01/2006 PROJECT INFORMATION: 116 Walcourt Loop - Edlws Grtns 9 COMPANY INFORMATION: Charles Thomas Homes, Inc COMPLIANCE: Passes Maximum UA = 774 Your Home = 546 29.5% Better Than Code Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame, Double Pane with Low-E Door 1: Solid Door 2: Solid Door 3: Glass Slab 1: Unheated, 0.0' insul. Air Conditioner 1: Electric Central Air, 14 SEER Furnace 1: Forced Hot Air, 80 AFUE Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1909 0.0 30.0 59 1743 15.4 0.0 113 198 0.640 127 20 0.013 0 18 0.013 0 18 0.440 8 229 0.0 239 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to m t 2000 IECC require n MECcheck Version 3.2 Release 1 . Builder/Designer ate i 200 (p CHARLES THOMAS HOMES, INC. P.O. BOX 10106 COLLEGE STATION, TX 77842 WF0751162 / 001 City of College Station PAGE 1 REQ. DATE: 03/07/06 `� 03/07/06 15:31:16 LOCATION: 116 WALCOURT LOOP LOC ID: 203540 REQUESTOR: CHARLES THOMAS HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT 4" SEWER TAP AND 3/4" WATER TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/07/06 SCHED COMPLETION: 03/07/06 ******************************************************************************** JOB ORDER RESULT COMVIENTS BUILDING PERMIT ...,.-CITY OF COLLEGE STATION 1101 AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ------------------------------------- i-------------------------------------- Application Number . . . . . 06-00000657 Date 3/07/06 Property Address . . . . . . 116 WALCOURT LOOP Property ID: 244030-0927-0090 R #• Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 130000 Owner Contractor ------------------------ ------------------------ CHARLES THOMAS HOMES, INC. CHARLES THOMAS P 0 BOX 10106 COLLEGE STATION TX 77842 (979) 696-4384 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1909.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 405.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . BK Permit Fee . . . . 550.00 Plan Check Fee .00 Issue Date . . . . 3/07/06 Valuation . . . . 130000 Expiration Date . . 9/03/06 Qty Unit Charge Per Extension BASE FEE 460.00 30.00 3.0000 THOU BLDG, VAL 100001-500000 90.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) ------------------- BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000657 Page 2 Date 3/07/06 Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE BUILDING D APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number 06-00000657 Page 3 Date 3/07/06 Special Notes and Comments POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Fully sheathed with Interior anchor bolts and bracing in master bedroom. ---------------------------------------------------------------------------- -----Other Fees .---------------SEWER-TAP-4" N350.00 ----------2-----A_"------------------ BUILDING DEPT R$'PRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00000657 Date 3/07/06 ---------------------------------------------------------------------------- Other Fees - WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited -------------------- Due ---------- ----------------- Permit Fee Total 550.00 550.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1300.00 1300.00 .00 .00 ------------------- BUILDING DE APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Property Address . . . . . . Property ID: R #. Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 06-00000658 116 WALCOURT LOOP 244030-0927-0090 TEMP POLE Date 3/07/06 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 0 Owner Contractor ------------------------ ------------------------ CHARLES THOMAS HOMES, INC. CHARLES THOMAS P O BOX 10106 COLLEGE STATION TX 77842 (979) 696-4384 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . BK Permit Fee . . . . 20.00 Issue Date . . . . 3/07/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 --------------------------------------------- BUILDING DEPT RFIPRESENTATIVE: APPLICANT: - - - - - - - - - - - - - - - - - - - - - f550 = 4 35o - ME APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3670 (979) 764-3496 FAX W W W.CI.COLLEG E-STATION.TX.US ADDRESS/LOCATION: l LOT V BLOCK a-)- ✓ SUBDIVISION DATE: V rW^ D W APPLICATION # 00 TEMP POLE * ' SEC/PH ✓ / BUSINESS/OWNER NAME: PHONE: CHARLES THOMAS HOMES, INC. CONTRACTOR/HOMEOWNER: pa BG1Y 10106 PHONE: CO TR f' ACTOR'ADDRESS: COLLEGE STATION, TX 77842 ti ELECTRICIAN:; ��� PLUMBER: '.1. C HVAC:2QMtoe-71 CENTS (Residential onl E CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION ',MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION• SWIMMING POOL Required) DESCRIPTION OF WORK: 4Ln5 TEXAS ACCESSIBILI STANDARD (fAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ 140 TOTAL AREA: HEATED AREA: D (Cost of Labor and Materials) g Tf PUBLIC SEWER NUMBER OF BEDROOMS:_ SEPTIC/TREATMENT SYST M NUMBER OF BATHROOMS: SEWER TAP: , INTERIOR WALL TYPE: E r`WATER TAP: / (I EXTERIOR WALL TYPE: tIZIE OTHER TAP: FOUNDATION TYPE: SIZE TEMP POLE ROOF TYPE: I [05 GARAGE TYPE: SINGLE DOUBLE TRIPLE a ATTACHED DETACHED CARP F7 SIGNATURE OF APPLICANT: *If proposed proposed work involves new commercial construction or eimpr`ove nts/renovations to an existing commercial property, building elevations are required. Official Use Only OwMents Y or NO fll� Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1(flat areas) Insulation R value of ceiling 2 (vaulted areastno attic) NIA Glazing SHGC / Glazing U-Factor R value of ductwork A/C SEER rating