HomeMy WebLinkAbout06-630Ni6ol6 Cochran - Re: CO @ 901 Scoffield Dr
From: Terry Boriskie
To: Benjamin McCarty; Chris Haver; Gina Southerla...
Date: 2/27/2007 10:06 am
Subject: Re: CO @ 901 Scoffield Dr
Contacted Pam at Ed froehling at 776-8266.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Paul Schoenfeld 2/27/2007 9:36 am >>>
Water is ok.
Sewer is buried put Flag where is located.
Paul
>>> Nicole Cochran 2/23/2007 12:21 PM >>>
Issues??
BP# 06-630
Thanks!
Nicole Cochran
CSR - Planning & Development
City of College Station
979.764.3570
www.cstx.00v
City• of College Station
1101 TEXAS AVENUE
COLLEGE STATION TX 77840
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . . . .
Owner
Contractor . . . . . .
Application number
Description of Work
Construction type . . .
Occupancy type . . . .
Flood Zone . . . . . .
Approved
2/27/07
537300-0101-0050
901 SCOFFIELD DR
COLLEGE STATION TX 77845
REATTA MEADOWS SEC 1 PH 1
REATTA MEADOWS, BLOCK 1, LOT 5
SINGLE FAMILY RESIDENTIAL
BARRON ROAD MEADOWS L.P.
ED FROEHLING BUILDERS
979 776-8266
06-00000630 000 000
RESIDENTIAL, 1 UNIT DETACHED NEW
COMBUSTIBLE (UNPROTECTED)
RESIDENTIAL-SFR/DUPLEX
Bui ding Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
PREPARED 2/23/07, 12:01:08 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/23/07
------------------------------------------------------------------------------------------------
ADDRESS . : 901 SCOFFIELD DR SUBDIV: REATTA MEADOWS SEC 1 PH 1
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER BARRON ROAD MEADOWS L.P. PHONE
PARCEL 537300-0101-0050
APPL NUMBER: 06-00000630 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/24/06 RH BLDG, FOUNDATION -SLAB TIME: 17:00
4/24/06 AP April 21, 2006 1:10:00 PM bkorthauer
04/24/2006. 10:36 AM RH PDA
Strings up ,slab ground installed.
B115 01 6/13/06 JGM BLDG, FRAMING TIME: 17:00
6/13/06 AE May 25, 2006 1:06:34 PM kwolfe
06/13/2006 03:44 PM JGM PDA
need interior anchors and bracing per print
B130 01 6/20/06 BI BLDG, INSULATION TIME: 17:00
6/20/06 CA June 20, 2006 8:56:36 AM bkorthauer
June 20, 2006 10:17:04 AM glsouth
B130 02 6/21/06 RH BLDG, INSULATION TIME: 17:00
6/21/06 AP June 21, 2006 11:51:51 AM bkorthauer
B125 01 V
BLDG, FINAL TIME: 17:00
Q7ieoci_
February 23, 2007 11:22:08 AM kwolfe.
-------------------------------------- COMMENTS AND NOTES--------------------------------------
1(`0 G / b\L
Nicole Cochran - Re: CO @ 901 Scoffield Dr Page 1
From:
Paul Schoenfeld
To:
Benjamin McCarty; Chris Haver; Gina Southerla...
Date:
2/27/2007 9:36 am
Subject:
Re: CO @ 901 Scoffield Dr
Water is ok.
Sewer is buried put flag where is located.
Paul
>>> Nicole Cochran 2/23/2007 12:21 PM >>>
Issues??
BP# 06-630
Thanks!
Nicole Cochran
CSR - Planning & Development
City of College Station
979.764.3570
www.cstx.aov
WF0751346 / 001 City of College Station PAGE 1
REQ. DATE:
03/08/06
03/08/06
13:18:51
LOCATION:
901 SCOFFIELD DR
LOC ID:
200828
REQUESTOR:
ED FROEHLING BUILDER ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
4" SWR TAP
3/4" WTR TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
03/08/06 SCHED COMPLETION:
03/08/06
********************************************************************************
JOB ORDER RESULT COMU24TS
Date: 2/23/2007
Inspection Comments for Finals
Permit Year: 6 Permit Number: 630
Address: 901 SCOFFIELD DR
Insp.
Inspection Type Code
p.
status
Inspection Result Comments
Description
B100
BLDG, FOUNDATION -SLAB
IC
04/24/2006 10:36 AM RH PDA
B100
BLDG, FOUNDATION -SLAB
IC
Strings up ,slab ground installed.
13115
BLDG, FRAMING
IC
06/13/2006 03:44 PM JGM PDA
13115
BLDG, FRAMING
IC
need interior anchors and bracing per print
B130
BLDG, INSULATION
IC
June 20, 2006 10:17:04 AM glsouth
P125
PLBG, FINAL
IC
February 22, 2007 9:59:46 AM kwolfe.
Page 1
BUILDING PERMIT
CITY C,F COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 06-00000630 Date 3/08/06
Property Address . .
. . . . 901 SCOFFIELD DR
Property ID:
537300-0101-0050
R #:
R300660
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . REATTA MEADOWS SEC 1 PH 1
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 112068
Owner
Contractor
------------------------
BARRON ROAD MEADOWS L.P.
------------------------
ED FROEHLING BUILDERS
PO BOX 277
ED FROEHLING
NORMANGEE
TX 778710277 3887 HIGH LONESOME RD
COLLEGE STATION TX 77845
(979) 776-8266
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1698.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 427.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
KW
Permit Fee . . . .
499.00 Plan Check Fee .00
Issue Date . . . .
3/08/06 Valuation . . . . 112068
Expiration Date . .
9/04/06
Qty Unit Charge
Per Extension
BASE FEE 460.00
13.00 3.0000
THOU BLDG, VAL 100001-500000 39.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
BUILDING DEPT ;ZEPRESENTAT;VE:
APPLICANT:
BUILDING PERMIT
CITY CIF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 06-00000630 Date 3/08/06
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
BUILDING DEPT REPRESENTATIVE:
.nn �
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000630
Page 3
Date 3/08/06
Special Notes and Comments
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
4
Application Number . . . . . 06-00000630 Date
3/08/06
----------------------------------------------------------------------------
Special Notes and Comments
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
Narrow wall bracing fully sheathed with APA garage framing
and interior anchors and bracing at rear porch area
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited
------------------------------
Due
---------------------------
Permit Fee Total 499.00 499.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1249.00 1249.00 .00
.00
BUILDING DEPT REPRESENTATIVE:
.n
APPLICANT:
CITY OF COLLEGE STATION
Planning & Dewlapment Sermitei
ADDRESS/LOCATION
APPLICATION FOR BUILDING PERMIT
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CSTX.GOV
go\
�j Foe Oft e Use Only
DATE:-. I( TRCC REG
APPLICATION # t/� w✓��
TEMP POLE #
LOT 'U11,-BLOCK SUBDIVISION RtPT1101, MEAjYjW5 SEC/PH 1 Pt
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER: E0 FRQa4Ut�k�• Bl1l�..C�-3�.� Pr C.
'17(Q- �Zf�
CONTRACTOR ADDRESS: 51*7 06d Ly090K]E ROAD C_:5-T-j< %1-7184S
ELECTRICIAN:,, �? es C,L.irmatc., PLUMBER: -r2►PL.G S
HVAC: IJ�NNC1jA rttVE GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION,MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY
DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK:
PROPOSED USE: 4ot
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ I ! Z j rye TOTAL AREA: Z.Z$ t HEATED AREA: l ro 9 4
(Cost of Labor and Materials)
�UBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
L� If
TAP: T'
WATER TAP:
OTHER TAP:
❑ TEMP POLE
GARAGE TYPE
/JIZE
3 4u
SIZE
SIZE
SINGLE
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE d TRIPLE
ATTACHED I ✓If DETACHED I I CARPORT
SIGNATURE OF APPLICANT: L' IV \ (C-"1 w
*If proposed work involves new commercial corisly.uGYjptiefefacade impr
commercial property, building elevations are required.
Official Use Only
V/Fhi Plans Examiner
Zoning Official
, 14 E or NO
)CAy 5 4c� &✓/#/f 6wo
2
v5RIGr.
C.ecalwj�Osl��01J
E i e
��zr/a4
renovations to anexisting
sting
Fire Marshall
Iw 1
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER Rating
S8'ZO"
l3�
30 �
.40/
- (P 4--'
1-45 - SeEE
CITY OF COLLEGE STATION
Planning t� Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLAN REVIEW/PERMIT NUMBER# o
DATE: 3 /(Q l ol.
BUILDING ADDRESS: qel Sao al
I. Foundation Requirements
NAJW
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
(*hrq"
CITY OF COLLEGE STATION
Planning & Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
N
2. Moisture barrier indicated on plans
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R.
Overhangs allowed on zero lot line construction up to 18"
K}
S.
T.
Protected openings on walls < three feet from property line
One hour tenant separation to roof deck between duplexes
AAA
111. Stairway Requirements
OK
A.
Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B.
Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C.
Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6") inches
5. All treads must be identical
D.
Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace
Requirements to be indicated onplans)
N
A.
Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B.
Masonry fireplace requires 2" clearance from all combustible materials
C.
Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten 10) feet horizontal
(*hrq"
CITY OF COLLEGE STATION
Planning t+Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
V. Electrical Service Requirements
NA
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
VI. Plumbing Requirements
N
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N O
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
Vill. Energy Requirements
N
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850 -
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
NAM
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
K
Does not block any water course or divert any flow
Elevation certificate if required
/��"
CITY OF COLLEGE STATION
Planning C ' Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
?-c/o-06
PLANS EXAMINER DATE
/ - -
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\I I I OCC.rck
TITLE: 901 SCOFFIELD DRIVE
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 02/24/06
DATE OF PLANS: JUNE 17, 2003
PROJECT INFORMATION:
ORIG 1110 COEBURN
SPEC HOME
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
COMPLIANCE: Passes
Maximum UA = 666
Your Home UA = 514
22.8% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.31
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Front
Projection factor: 0.19
Door 1: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Left Side
Projection factor: 0.27
Wall 3: Wood Frame, 16" o.c.
Window 3: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Back
Projection factor: 0.23
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
1698
30.0
0.0
59
428
15.0
0.0
27
44
0.600 26
38
383 15.0 0.0
1
418 15.0 0.0
68
0.400 15
29
0.600 1
27
0.600 41
Wall 4: Wood Frame, 16" o.c.
Window 4: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.:
Projection factor: 1.00
Door 2: Glass
SHGC: 0.78
Bldg. faces 135 deg. from North; Comp. orient.:
Projection factor: 0.81
Floor 1: Slab-On-Grade:Unheated
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 13 SEER
383
82
Right Side
18
Right Side
200
15.0 0.0 22
0.600 49
0.580 10
0.0 208
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in RES checkVersion 3.5 Release lb (formerly MECchec� and to comply with the mandatory requirements listed in
the RES checklnsp on ecklist.
Builder/Designer Date
_ :l i l i• i J rl F, °i� 1� ! 'J !r P n P [ n ' 'ti 1
L ,CL ot OhmBi�E atk01 if WbVOIASMW6Wd2�7 h AC • ��JiU10�1'� If 7W, .i/a� »• Co ,S}�rAW rem rZsO,1V?p #XWR
1
4ot 4
.
No,r or Fbrn+erfy
QWT011 Rmd WOOW3 LP.
r
Vol. 6118. Pg. 47
I
U)
42.1'
2e.5,a,ii
;o
m �:
CU
.��
ProPve�a
Driveway
IN
j
Residenceor
Y
_
\
, Block 1
a
heaUd
�
j
p
,Mead'aws
s&hd iL7)bm-
LL LZ
J
�V
I
'hl 25'
/
it
Lot S
Now or Formrriy
�7onon Rood Naadowa LP.
i
Vol. 6110, Pg. 47
Scale: 1" 20'
-- ,- -- CLOWE M-TA RAISIUS IENCN f"K091. ORC.
C1 473723' 50.00' 3y.20" S t2'1U'*6' W
M'�