Loading...
HomeMy WebLinkAbout06-630Ni6ol6 Cochran - Re: CO @ 901 Scoffield Dr From: Terry Boriskie To: Benjamin McCarty; Chris Haver; Gina Southerla... Date: 2/27/2007 10:06 am Subject: Re: CO @ 901 Scoffield Dr Contacted Pam at Ed froehling at 776-8266. Terry Boriskie City of College Station Residential Plans Examiner 979-764-3744 >>> Paul Schoenfeld 2/27/2007 9:36 am >>> Water is ok. Sewer is buried put Flag where is located. Paul >>> Nicole Cochran 2/23/2007 12:21 PM >>> Issues?? BP# 06-630 Thanks! Nicole Cochran CSR - Planning & Development City of College Station 979.764.3570 www.cstx.00v City• of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner Contractor . . . . . . Application number Description of Work Construction type . . . Occupancy type . . . . Flood Zone . . . . . . Approved 2/27/07 537300-0101-0050 901 SCOFFIELD DR COLLEGE STATION TX 77845 REATTA MEADOWS SEC 1 PH 1 REATTA MEADOWS, BLOCK 1, LOT 5 SINGLE FAMILY RESIDENTIAL BARRON ROAD MEADOWS L.P. ED FROEHLING BUILDERS 979 776-8266 06-00000630 000 000 RESIDENTIAL, 1 UNIT DETACHED NEW COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX Bui ding Official VOID UNLESS SIGNED BY BUILDING OFFICIAL PREPARED 2/23/07, 12:01:08 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/23/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 901 SCOFFIELD DR SUBDIV: REATTA MEADOWS SEC 1 PH 1 CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER BARRON ROAD MEADOWS L.P. PHONE PARCEL 537300-0101-0050 APPL NUMBER: 06-00000630 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/24/06 RH BLDG, FOUNDATION -SLAB TIME: 17:00 4/24/06 AP April 21, 2006 1:10:00 PM bkorthauer 04/24/2006. 10:36 AM RH PDA Strings up ,slab ground installed. B115 01 6/13/06 JGM BLDG, FRAMING TIME: 17:00 6/13/06 AE May 25, 2006 1:06:34 PM kwolfe 06/13/2006 03:44 PM JGM PDA need interior anchors and bracing per print B130 01 6/20/06 BI BLDG, INSULATION TIME: 17:00 6/20/06 CA June 20, 2006 8:56:36 AM bkorthauer June 20, 2006 10:17:04 AM glsouth B130 02 6/21/06 RH BLDG, INSULATION TIME: 17:00 6/21/06 AP June 21, 2006 11:51:51 AM bkorthauer B125 01 V BLDG, FINAL TIME: 17:00 Q7ieoci_ February 23, 2007 11:22:08 AM kwolfe. -------------------------------------- COMMENTS AND NOTES-------------------------------------- 1(`0 G / b\L Nicole Cochran - Re: CO @ 901 Scoffield Dr Page 1 From: Paul Schoenfeld To: Benjamin McCarty; Chris Haver; Gina Southerla... Date: 2/27/2007 9:36 am Subject: Re: CO @ 901 Scoffield Dr Water is ok. Sewer is buried put flag where is located. Paul >>> Nicole Cochran 2/23/2007 12:21 PM >>> Issues?? BP# 06-630 Thanks! Nicole Cochran CSR - Planning & Development City of College Station 979.764.3570 www.cstx.aov WF0751346 / 001 City of College Station PAGE 1 REQ. DATE: 03/08/06 03/08/06 13:18:51 LOCATION: 901 SCOFFIELD DR LOC ID: 200828 REQUESTOR: ED FROEHLING BUILDER ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 4" SWR TAP 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/08/06 SCHED COMPLETION: 03/08/06 ******************************************************************************** JOB ORDER RESULT COMU24TS Date: 2/23/2007 Inspection Comments for Finals Permit Year: 6 Permit Number: 630 Address: 901 SCOFFIELD DR Insp. Inspection Type Code p. status Inspection Result Comments Description B100 BLDG, FOUNDATION -SLAB IC 04/24/2006 10:36 AM RH PDA B100 BLDG, FOUNDATION -SLAB IC Strings up ,slab ground installed. 13115 BLDG, FRAMING IC 06/13/2006 03:44 PM JGM PDA 13115 BLDG, FRAMING IC need interior anchors and bracing per print B130 BLDG, INSULATION IC June 20, 2006 10:17:04 AM glsouth P125 PLBG, FINAL IC February 22, 2007 9:59:46 AM kwolfe. Page 1 BUILDING PERMIT CITY C,F COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000630 Date 3/08/06 Property Address . . . . . . 901 SCOFFIELD DR Property ID: 537300-0101-0050 R #: R300660 Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . REATTA MEADOWS SEC 1 PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 112068 Owner Contractor ------------------------ BARRON ROAD MEADOWS L.P. ------------------------ ED FROEHLING BUILDERS PO BOX 277 ED FROEHLING NORMANGEE TX 778710277 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1698.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC TAZ 427.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KW Permit Fee . . . . 499.00 Plan Check Fee .00 Issue Date . . . . 3/08/06 Valuation . . . . 112068 Expiration Date . . 9/04/06 Qty Unit Charge Per Extension BASE FEE 460.00 13.00 3.0000 THOU BLDG, VAL 100001-500000 39.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) BUILDING DEPT ;ZEPRESENTAT;VE: APPLICANT: BUILDING PERMIT CITY CIF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 06-00000630 Date 3/08/06 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE BUILDING DEPT REPRESENTATIVE: .nn � APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000630 Page 3 Date 3/08/06 Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00000630 Date 3/08/06 ---------------------------------------------------------------------------- Special Notes and Comments SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES Narrow wall bracing fully sheathed with APA garage framing and interior anchors and bracing at rear porch area ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" 350.00 WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 499.00 499.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1249.00 1249.00 .00 .00 BUILDING DEPT REPRESENTATIVE: .n APPLICANT: CITY OF COLLEGE STATION Planning & Dewlapment Sermitei ADDRESS/LOCATION APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CSTX.GOV go\ �j Foe Oft e Use Only DATE:-. I( TRCC REG APPLICATION # t/� w✓�� TEMP POLE # LOT 'U11,-BLOCK SUBDIVISION RtPT1101, MEAjYjW5 SEC/PH 1 Pt BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: E0 FRQa4Ut�k�• Bl1l�..C�-3�.� Pr C. '17(Q- �Zf� CONTRACTOR ADDRESS: 51*7 06d Ly090K]E ROAD C_:5-T-j< %1-7184S ELECTRICIAN:,, �? es C,L.irmatc., PLUMBER: -r2►PL.G S HVAC: IJ�NNC1jA rttVE GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION,MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION * SLAB ONLY DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: PROPOSED USE: 4ot HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ I ! Z j rye TOTAL AREA: Z.Z$ t HEATED AREA: l ro 9 4 (Cost of Labor and Materials) �UBLIC SEWER ❑ SEPTIC/TREATMENT SYSTEM L� If TAP: T' WATER TAP: OTHER TAP: ❑ TEMP POLE GARAGE TYPE /JIZE 3 4u SIZE SIZE SINGLE NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE FOUNDATION TYPE: ROOF TYPE: DOUBLE d TRIPLE ATTACHED I ✓If DETACHED I I CARPORT SIGNATURE OF APPLICANT: L' IV \ (C-"1 w *If proposed work involves new commercial corisly.uGYjptiefefacade impr commercial property, building elevations are required. Official Use Only V/Fhi Plans Examiner Zoning Official , 14 E or NO )CAy 5 4c� &✓/#/f 6wo 2 v5RIGr. C.ecalwj�Osl��01J E i e ��zr/a4 renovations to anexisting sting Fire Marshall Iw 1 Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER Rating S8'ZO" l3� 30 � .40/ - (P 4--' 1-45 - SeEE CITY OF COLLEGE STATION Planning t� Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS PLAN REVIEW/PERMIT NUMBER# o DATE: 3 /(Q l ol. BUILDING ADDRESS: qel Sao al I. Foundation Requirements NAJW A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements N A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. (*hrq" CITY OF COLLEGE STATION Planning & Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. N 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" K} S. T. Protected openings on walls < three feet from property line One hour tenant separation to roof deck between duplexes AAA 111. Stairway Requirements OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6") inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) N A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10) feet horizontal (*hrq" CITY OF COLLEGE STATION Planning t+Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS V. Electrical Service Requirements NA A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements N A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N O A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements N A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 - N Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements NAM Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 N Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 K Does not block any water course or divert any flow Elevation certificate if required /��" CITY OF COLLEGE STATION Planning C ' Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS ?-c/o-06 PLANS EXAMINER DATE / - - REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\I I I OCC.rck TITLE: 901 SCOFFIELD DRIVE CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 02/24/06 DATE OF PLANS: JUNE 17, 2003 PROJECT INFORMATION: ORIG 1110 COEBURN SPEC HOME COMPANY INFORMATION: ED FROEHLING BUILDER, INC COMPLIANCE: Passes Maximum UA = 666 Your Home UA = 514 22.8% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.31 Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Front Projection factor: 0.19 Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Left Side Projection factor: 0.27 Wall 3: Wood Frame, 16" o.c. Window 3: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Back Projection factor: 0.23 Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1698 30.0 0.0 59 428 15.0 0.0 27 44 0.600 26 38 383 15.0 0.0 1 418 15.0 0.0 68 0.400 15 29 0.600 1 27 0.600 41 Wall 4: Wood Frame, 16" o.c. Window 4: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 135 deg. from North; Comp. orient.: Projection factor: 1.00 Door 2: Glass SHGC: 0.78 Bldg. faces 135 deg. from North; Comp. orient.: Projection factor: 0.81 Floor 1: Slab-On-Grade:Unheated Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 13 SEER 383 82 Right Side 18 Right Side 200 15.0 0.0 22 0.600 49 0.580 10 0.0 208 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in RES checkVersion 3.5 Release lb (formerly MECchec� and to comply with the mandatory requirements listed in the RES checklnsp on ecklist. Builder/Designer Date _ :l i l i• i J rl F, °i� 1� ! 'J !r P n P [ n ' 'ti 1 L ,CL ot OhmBi�E atk01 if WbVOIASMW6Wd2�7 h AC • ��JiU10�1'� If 7W, .i/a� »• Co ,S}�rAW rem rZsO,1V?p #XWR 1 4ot 4 . No,r or Fbrn+erfy QWT011 Rmd WOOW3 LP. r Vol. 6118. Pg. 47 I U) 42.1' 2e.5,a,ii ;o m �: CU .�� ProPve�a Driveway IN j Residenceor Y _ \ , Block 1 a heaUd � j p ,Mead'aws s&hd iL7)bm- LL LZ J �V I 'hl 25' / it Lot S Now or Formrriy �7onon Rood Naadowa LP. i Vol. 6110, Pg. 47 Scale: 1" 20' -- ,- -- CLOWE M-TA RAISIUS IENCN f"K091. ORC. C1 473723' 50.00' 3y.20" S t2'1U'*6' W M'�