HomeMy WebLinkAbout06-601PREPARED 6/09/06, 11:37:56 INSPECTION TICKET PAGE 7 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/09/06 ------------------------------------------------------------------------------------------------ ADDRESS . : 4706 WILLIAMS CREEK DR SUBDIV: WILLIAMS CREEK PH 2 CONTRACTOR BENCHMARK HOMES/DBA G.D.T.INC PHONE (979) 690-7117 OWNER . . PHONE PARCEL . . 660050-0204-0090 APPL NUMBER: 06-00000601 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 3/08/06 JGM BLDG, FOUNDATION -SLAB TIME: 17:00 3/08/06 AP March 8, 2006 11:03:55 AM bkorthauer Strings On Setbacks O.K. Slab Ground Installed B11- 01 4/03/06 OC BLDG, FRAMING TIME: 17:00 4/03/06 AP March 31, 2006 1:01:28 PM glsouth B130 01 4/06/06 BH BLDG, INSULATION TIME: 17:00 4/06/06 AP April 6, 2006 9:22:48 AM kwolfe April 6, 2006 9:23:02 AM kwolfe B125 Olt' 6/09/06 BLDG, FINAL TIME: 17:00 �j�,of a.W!X June 9, 2006 11 : O l: 2 6 AM bkorthauer ------+------------------� --------- COMMENTS AND NOTES -------------------------------------- JUN. 9,2006 11:26AM Brazos County Health Department N0,0340 P. 2 Brazos County Health Department 201 North Texas Ave. } Bryan, TX 77803 5317 (D 6k (979) 361-444006- LICENSE TO OPERATE AN ON SITE SEWAGE FACILITY THIS IS TO CERTIFY that the on slte sewage facility owned by: OSSF #: 2006 - 2382 WENDEL, SHANE A. WILLIAMS CREEK CT. 4706, College Station TX 77845 Grid: WILLIAMS CREEK Block: 4 Lot: 9 Certificate of Compliance: IN C.S. installed By: WAGER, JAY C.-WAGER BACKHOE Engineered By: GONZALEZ, STEVEN- PREMIER ENVIRONMENTAL DESIGNS Date Purchased: 5/30/2006 Final Inspection Date: 6/5/2006 Disinfectant: Liquid Chl Bedrooms: 4 Employees: 0 MaxGPD: 365 The private sewage facility licensed above was installed according to the current and minimum guidelines of the Texas Commission on Environmental Quality (TCEQ) and Brazos County. This aerobic system with gray diomal requires a disinfectant for final treatment of the sprayed effluent. It is the responsibility of the homeowner to monitor the disinfectant and to add more when needed. (Swimming pool chlorine tablets are not acceptable substitutes). Under no circumstance are any food crops or edible foods to be grown in the spray area. Mowing of the sprayfield on a regular basis should also be done to help with the evaporation process. The current maintenance contract for this system will expire 2-years from the above final inspection date. A new maintenance contract must be in force at that time, and a copy of the new contract filed with this office 30 days before contract expires. This is a NON -TRANSFERABLE license. Upon transfer of ownership, the new owner shall be required to transfer the original license into his/her ;name. Should the system malfunction in the future, it will be the licensee's responsibility to bring the system in compliance with all current state and county regulations. This license does not extend to the material's, workmanship, or fabrication, of the system, so as to expressly or impliedly grant the owner, or installer of the system any warranty by / or rights against Brazos County and / or the Brazos County Health Department, as to the quality or durability of the system, nor compliance with licensee's individual specifications and requirements, but solely relates to the system meeting the requirements of the above named regulatory body in effect as of this date. R-1 G Environmental Health cialist Kim Wolfe - Insulation request inspection result, 4706 Williams Creek Dr. #66-661 Page 1 - From: Brian Henry To: Southerland, Gina Date: 4/6/2006 9:14:00 AM Subject: Insulation request inspection result, 4706 Williams Creek #06-601 Print for File Inspected insulation, 4706 Williams Creek Dr. #06-601, Benchmark Homes, 4-6-05 Inspection result: Inspected OK for Good Cents Notes: Repair wall insulation at garage wall and dining room wall. CC: Korthauer, Brittany; Wolfe, Kim CITY OF COLLEGE STATION Planning 6- Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS PLAN REVIEW/PERMIT NUMBER# _ o DATE: 3 /.r /o BUILDING ADDRESS: o L&); If A��4 C&_ek I. Foundation Requirements N K A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated r� II. Framing: Floor, Wall, Ceiling and Roof Requirements N K A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall -covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. (*hrq" CITY OF COLLEGE STATION Planning d' Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. NA/ 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes III. Stairway Requirements O A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1 /2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6") inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements (to be indicated on plans) NA/ A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal (*hr4" CITY OF COLLEGE STATION Planning d Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS V. Electrical Service Requirements NA/ A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements NA/ A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/ K A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements NAj A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size ' Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements N Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 K Does not block any water course or divert any flow Elevation certificate if required 1 A, 1" I� CITY OF COLLEGE STATION Planning 6 Development Services Comments: PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS AAn�r ` - O` C PLANS EXAMINER ! J♦ DATGE7 50' REAR SETBACK ------- YI I vI 1 coI i 1 wI U)LU EC,ES� U z m WI / jai aI -/ ►o . I �- 12 lot OF --�— — — — — — — — ------ I I 50' FRONT S ACK"----_ ,_ I� r I I WILLIAMS CREEK DRIVE FOR WILLIAM5 CREEK BENCHMARK HOLES S I TE FLAN V LOT: CI PHASE 3 HFATED AREA, 2,433 so. Fr. GLENN THOMAS BLOCK: 4 5LAB AREA- 3,470 30, Ff. PHONE. FAX, SCALE- I' - 4& WILLIAMS CREEK DRIVE (409) iao-nn (ti+) wio-nie REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release la Data filename: C:\Program Files\Check\REScheck\REScheck docs\283BM.rck TITLE: Benchmark Homes Job 283 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 02/ 18/06 DATE OF PLANS: February 20, 2006 PROJECT INFORMATION: BM Job #283 Lot 9 Block 4 Williams Creek Phase 2 4706 Williams Creek Court College Station, TX 77845 COMPANY INFORMATION: GDT Incorporated dba Benchmark Homes 1110 12th Man Court College Station, TX 77845 NOTES: New Home COMPLIANCE: Passes Maximum UA = 845 Your Home UA = 821 2.8% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.34 Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Ceiling (no attic) Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.34 Door 1: Solid Door 2: Glass SHGC: 0.33 Floor 1: Slab-On-Grade:Unheated Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 2212 30.0 0.0 77 221 0.0 0.0 132 1966 13.0 0.0 123 387 0.650 252 20 0.140 3 53 0.310 16 209 0.0 218 Insulation depth: 0.0' Heat Pump 1: Electric Central Air, 7.2 HSPF, 14 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in RES checkVersion 3.5 Release la (formerly MECchec/ and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer Date REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.5 Release la DATE: 02/ 18/06 TITLE: Benchmark Homes Job 283 Bldg. Dept. Use I I [ ] I I I [ ] [ ] [ ] [ ] Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 2. Ceiling 2: Cathedral Ceiling (no attic), R-0 (uninsulated) Comments: Above -Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: 1. Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.650 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 1: Solid, U-factor: 0.140 Comments: 2. Door 2: Glass, U-factor: 0.310 Comments: Floors: 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: [ ] I 1. Heat Pump 1: Electric Central Air, 7.2 HSPF, 14 SEER or higher I Make and Model Number I Solar Heat Gain Coefficient: [ ] I The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. I Air Leakage: [ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] I Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a I 3" clearance from insulation. I Materials Identification: [ ] I Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] I Materials and equipment must be identified so that compliance can be determined. [ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ( ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the I levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems ' Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) WF0752077 / 001 City of College Station 1I PAGE 1 u_U6. REQ. DATE: 03/10/06 03/10/06 15:33:50 LOCATION: 4706 WILLIAMS CREEK DR LOC ID: 202202 REQUESTOR: BENCHMARK HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/10/06 SCHED COMPLETION: 03/10/06 ******************************************************************************** JOB ORDER RESULT COMMENTS BP50OU04 City of College Station 3/07/06 Request For Inspection - Inspection History 17:08:07 Application number 06 00000602 000 000 Application type TEMP POLE Tenant number, name Permit type/seq/VRU : TEMP 00 0'00422006 TEMP POLE PERMIT Property address . . 4706 WILLIAMS CREEK DR Type options, press Enter. 2=Change 4=Delete 5=View Status Inspector Request Results Opt Date Inspection Description ID Date Time Stat Date 3/07/06 TEMP, FINAL JGM 3/07/06 17:00 AP 3/07/06 Bottom F3=Exit F6=Add inspection F12=Cancel F15=Override TRANSMISSION VERIFICATION REPORT TIME 03/06/2006 23:55 NAME COCS DEVELOPMENT SER FAX 9797643496 TEL 9797643570 SER.# BROE2J341073 DATEJIME 03/06 23:54 FAX NO./NAME 98215796 DURATION 00:00:17 PAGE(S) 01 RESULT OK MODE STANDARD ECM BUILDING PERMIT —CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STA-rrON, TX 77840 PHONE: (979)764-3570,' FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000601 Date 3/06/06 Property Address . . . . . . 4706 WILLIAMS CREEK DR Property ID: 660050-0204-0090 R #: R**** Application type description RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WILLIAMS CREEK PH 2 Property Use . . . . . . . . Property Zoning . . . . . . . RURAL RESIDENTIAL SUB. Application valuation . . . . 160578 Owner Contractor ------------------------ ------------------------ BENCHMARK HOMES/DBA G.D.T.INC GLENN THOMAS 1110 12TH MAN COURT COLLEGE STATION TX 77845 (979) 690-7117 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2433.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 329.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . BK Permit Fee . . . . 643.00 Plan Check Fee .00 Issue Date . . . . 3/06/06 Valuation . . . . 160578 Expiration Date . . 9/02/06 Qty Unit Charge Per Extension BASE FEE 460.00 61.00 3.0000 THOU BLDG, VAL 100001-500000 183.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) BUILDING DEPT REPR-HSENTA'dIVE:,P„� APPLICANT: .__�� BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000601 Page 2 Date 3/06/06 Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY OBTAIN HEALTH DEPARTMENT APPROVAL: CALL 979-361-4440 FOR MORE INFORMATION. SEPTIC SYSTEMS INSTALLED PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 06-00000601 Date 3/06/06 ---------------------------------------------------------------------------- Special Notes and Comments RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 4 Application Number . . . . . 06-00000601 Date 3/06/06 ---------------------------------------------------------------------------- Special Notes and Comments PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK 272' Minimum finished floor for sewer only Narrow wall bracing fully sheathed. ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 643.00 643.00 Plan Check Total .00 .00 Grand Total 643.00 643.00 BUILDING DEPT REPR,F4$ENTA APPLICANT: .00 .00 .00 .00 .00 .00 ----_h--.----------------------- TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000602 Date 3/06/06 Property Address . . . . . . 4706 WILLIAMS CREEK DR Property ID: 660050-0204-0090 R #: R**** Application type description TEMP POLE Subdivision Name . . . . . . WILLIAMS CREEK PH 2 Property Use . . . . . . . . Property Zoning . . . . . . . RURAL RESIDENTIAL SUB. Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ BENCHMARK HOMES/DBA G.D.T.INC GLENN THOMAS 1110 12TH MAN COURT COLLEGE STATION TX 77845 (979) 690-7117 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . BK Permit Fee . . . . 20.00 Issue Date . . . . 3/06/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged ---------- Paid Credited ------------------------------ Due Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------- BUILDING DE APPLICANT: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION - 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 CITY OF COLLEGE STATION (979) 764-3570 (979) 764-3496 FAX Planninj d Development Service; WWW.CSTX.GOV For Oftke Use Only DATE:??1da, TRCCREG APPLICATION # IZ j TEMP POLE # Q D;;� ADDRESS/LOCATION: - LOT �_/BLOCK SUBDIVISION O 1 a�11 0 -C-1 ilk SEC/PH BUSINESS/OWNER NAME: - GV \ -1Ae, PHONE:_ (9 D•T 11 �CONTRACTOR/HOMEOWNER: k . 1�00 k&S PHONE: 112- CONTRACTOR ADDRESS: X I to 12— T VA M wn,( 0,D Vt ELECTRICIAN: t C'Ft %L, PLUMBER: HVAC: -�' 1% toZ, GOOD CENTS (Residential only): �- CLASS OF WORK , ACCESSORY/STORAGE LOCATION - RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION ' SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION* SWIMMING -POOL " Required) DESCRIPTION OF WORK: STRUCTURE USE: �,� HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT 13EGISTRATION# EABPRJ 1•-! VALUATION:;$-4 146,) j O TOTAL AREA: 34A"ID HEATED AREA: 07 �-33 . (Cost of Labor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: ® SEPTIC/TREATMENT SYSTEM NUMBER OF'BATHROOMS: a SEWER TAP: ; INTERIOR WALL TYPE: S AO SIZE , W���e�.l► � WATER TAP: EXTERIOR WALL TYPE: r SIZE 1 _ OTHER TAP: FOUNDATION TYPE: S Mb 014 16- 5' SIZE TEMP POLE S u S e4W ROOF TYPE: GARAGE TYPE: SINGLE a DOUBLE TRIPLE " ATTACHED aDECHED aCARPO TSIGNATURE OF APPLICANT:'• 1`If proposed work involves new commerciaction'or facade Improvements/renovations to an existing commercial property, building elevations are required. ' - OfficialUse Only ents: c ' � ES r NO �47 Plan$ Examiner Zoning Official , .27LIt N►i.h � �«t. S�Jr.G '�IFurl�. S1•ea.�ed - Energy Code- Compliance Information U 4t •,y Y F /o G1a,?ing �of exterior walls Insulation R value of exterior walls Insulation R value, of ceiling 1. (flat areas)' Insulation R yalue:of•ceiling 2 (vaulted areas/no attic) kj Q w }. Glazing SHGC . 3 . T � Glazing U-Factor r , R-alue'ofductwork A/C SEER Rating i t 4