HomeMy WebLinkAbout06-587— a . ---%,
TInspection Results Entry - City of College Station
Inspection Results Entry
Application number, type: 06 00000587 RESIDENTIAL, 1 UNIT DETACHED NEW
Structure, permit: 000 000 BLDG 00
Inspection type, sequence: B125 0001 BLDG, FINAL i
Property address: 414 ROCK SPRING CT �
i
Request date, time, by: 9122/06 17.00 GS
Inspector ID: 1JGM ►
i
Results date: 09/22/2006
Results status: FET7
Final Inspection flag: 1
t jRt Edit comments
i Display inspection penalties
i Point value: F 1
s
s
t
i
a'13a
Kim Wolfe - Re: Calling for C.O. @ 414 Rock Spring Ct. Y - 4 _ "- age 1
From: Joe Garcia
To: Benjamin McCarty; Chris Haver; Gina Southerland; Kim Wolfe; Nicole Cochran;
Terry Boriskie
Date: 10/26/2006 4:33:01 PM
Subject: Re: Calling for C.O. @ 414 Rock Spring Ct.
THIS ONE IS GOOD TO GO. JMG
>>> Terry Boriskie 10/26/06 11:08 AM >>>
It has been fixed per the builder.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Terry Boriskie 10/4/2006 9:24 am >>>
The builder has been notified and will fix.
Terry Boriskie
City of College Station
Residential Plans Examiner
979-764-3744
>>> Joe Garcia 10/3/2006 4:27 pm >>>
the sewer box is broken, and the sewer lid is missing. the sewer lid must me solid. Hughes Supply on
Graham Rd., and ACT in the Brazos county industrial park on 2818 both carry the sewer lid. JMG
>>> Gina Southerland 10/03/06 11:55 AM >>>
Are there any issues?
Gina Southerland
Customer Service Rep.
City Of College Station
1101 Texas Ave.
979-764-3570
glsoutherland(a)cstx.gov
WF0750711 / 001 City of College Station PAGE 1
REQ. DATE: 03/06/06 03/06/06 10:25:46
LOCATION: 414 ROCK SPRING CT LOC ID: 199474
REQUESTOR: T-2 PROPERTIES, INC ORIGIN: CUSTOMER -WALK IN
REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT
TEMP POLE PASSED
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/06/06 SCHED COMPLETION: 03/06/06
********************************************************************************
JOB ORDER RESULT COMVMNTS
WF0750528 / 001 City of College Station
PAGE 1
REQ. DATE: 03/03/06 03/03/06 15:58:36
LOCATION: 414 ROCK SPRING CT LOC ID: 199474
REQUESTOR: T-2 PROPERTIES ORIGIN: CUSTOMER -WALK IN
REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT
4" SEWER TAP AND 3/4" WATER TAP
********************************************************************************
TASK: SET UP NEW UTILITY ACCT SET READY
SCHED START: 03/03/06 SCHED COMPLETION: 03/03/06
********************************************************************************
JOB ORDER RESULT C014KENTS
BUILDING PERMIT
CITY OF COLLEGE;STATION
1101 TE NAS-AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 ","'FAX: (979) 764-3-1-06
----------------------------------------------------------------------------
Application Number .
. . . . 06-00000587 Date 3/03/06
Property Address . .
. . . . 414 ROCK SPRING CT
Property ID:
582830-0203-0350
R #:
R116917
Application type description
RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . SPRING MEADOWS PH 2
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 1400-00
Owner
Contractor
------------------------
T-2 PROPERTIES INC
------------------------
T-2 PROPERTIES, INC.
1700 BARAK LN
DBA CLASSIC HOMES
BRYAN
TX 778023311 TIM THURMOND
BRYAN TX 77802
(979) 846-8845
--- Structure Information
000 000 SINGLE FAMILY
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1975.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
TAZ 410.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
BK
Permit Fee . . . .
580.00 Plan Check Fee .00
Issue Date . . . .
3/03/06 Valuation . . . . 140000
Expiration Date . .
8/30/06
Qty Unit Charge
Per Extension
BASE FEE 460.00
40.00 3.0000
THOU BLDG, VAL 100001-500000 120.00
----------------------------------------------------------------------------
Special Notes and Comments
Exterior walls located
on property line shall have a one
hour fire resistance
rating without openings. Overhangs
extending over the property
line shall have a one hour fire
------------------------------------------ ------------
-------------- ---
BUILDING DEPT REPRESENTATIVE: ��_
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEzveAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-34.96
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 06-00000587 Date 3/03/06
----------------------------------------------------------------------------
Special Notes and Comments
resistant construction on the under side,without openings
and shall extend a maximum of 18". Slab edge shall be
built on property line.
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
BUILDING DEPT REPRESENTATIVE.
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 "TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000587
Page 3
Date 3/03/06
Special Notes and Comments
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
------------------------------------------ --------- --------------
1
BUILDING DE
APPLICANT: 1
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
—PHONE:—(-979T764-3570 FAX: (979) 764-3496
Page
4
Application Number . . . . . 06-00000587 Date
3/03/06
----------------------------------------------------------------------------
Special Notes and Comments
EQUIPMENT AND A PRESSURE REDUCING VALVE
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
Narrow wall bracing Fully sheathed
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4"
350.00
WATER TAP 3/4"
400.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited
----------------------------------------
Due
-----------------
Permit Fee Total 580.00 580.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1330.00 1330.00 .00
.00
--------------------------------------------------
BUILDING DEPT _REPRESENTAITIVE ; l/ l/rit L
APPLICANT: ' C \
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840 —
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number
. . . . .
06-00000588 Date
3/03/06
Property Address .
. . . . .
414 ROCK SPRING CT
Property ID:
582830-0203-0350
R #:
R116917
Application type description
TEMP POLE
Subdivision Name .
. . . . .
SPRING MEADOWS PH 2
Property Use . . .
. . . . .
RESIDENTIAL
Property Zoning . .
. . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
T-2 PROPERTIES INC
------------------------
T-2 PROPERTIES, INC.
1700 BARAK LN
DBA CLASSIC HOMES
BRYAN
TX 778023311
TIM THURMOND
BRYAN
TX 77802
(979) 846-8845
----------------------------------------------------------------------------
Permit . . . . . .
TEMP POLE
PERMIT
Additional desc . .
BK
Permit Fee . . . .
20.00
Issue Date . . . .
3/03/06
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . .
. . . . .
TEMP ELECT POLE CONNECT
45.00
----------------------------------------------------------------------------
Fee summary
-----------------
Charged
----------
Paid Credited
------------------------------
Due
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
BUILDING DEPT REPRESENTATIVE:
APPLICANT: , �-
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW. OLLEGESTATION.TX.US
ADDRESS/LOCATION: `TIq A'OCl4 PnIPVG �T
R
Use ONy
DATE: 4
APPLICATION # p /
TEMP POLE #
S;��O'vw
LOT 3 S/ BLOCK SUBDIVISION' JA'R/A/6 11./ 59,004VS" / l�SF_ Z
BUSINESS/OWNER NAME: 2 p2o1017-2n5s //JC PHONE:
CONTRACTOR/HOMEOWNER: S'/--f -Mz5 / �JPHONE: S.�1 C A
/
CONTRACTOR ADDRESS: ��(� �!/f/li�¢iC L fI e1Z 7L9h/
/ 1 X %7,0
ELECTRICIAN: ��, �ffKcu'6y (� '. PLUMBER: �Ly<'iJEj6l�r
HVAC: AV�'//gG0I;5'f'kzR_q G GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOYANG SHELL ONLY
DEMOLITION (Asbestos Survey) EW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK: �'iTF GvU� �G �i9�iiw6 CVvNP��T� STi2v�TT7n�
/Gtrifh` D (,/j I—)5w cz G nk_' � I �I n 1(2 y--r709;v � Ght'-ntr,Pffoxty&
STRUCTURE USE:/�I/6G/_s/'h/L I � Z��20 GUl G !wJ_ - /ON77c7 lfopf-t5
HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PRO CT REGISTRATION# EABPRJ
VALUATION: $ `��, (�O (j "' TOTAL AREA: *Za Z� HEATED AREA: /77J__�
(Cost of La or and Materials)
g�JF U LIC SEWER
SEPTIC/TREATMENT SYSTEM
l�
2-SEWER TAP:
1s°
WATER TAP:
SIZE
❑ OTHER TAP:
6 / SIZE
S TEMP POLE
3q GARAGE TYPE: SINGLEEJ
-1 ATTACHED
SIGNATURE OF APPLICANT:
NUMBER OF BEDROOMS: 3
NUMBER OF BATHROOMS: 2
INTERIOR WALL TYPE: - 14,laap �IZ/Q/yJ� ���7/ R&
EXTERIOR WALL TYPE: r LyD00 /'/ZIiH1F —%:&T /&
FOUNDATION TYPE: .- '�.V G , 9A✓ 614,4 "
ROOF TYPE: �/u�p�/i�0ol/ �Ur•�,
DOUBLE Ell ---TRIPLE
Official Use Only
'7Plans Examiner
GAf-&Ie w 1 �}
v6iy 5
CARPORT a
Zoning Official
mments:
- - NO
• % �� �c,� �P re w 6 lam,%
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas) 3 d
Insulation R value of ceiling 2 (vaulted areas/no attic)
!L of Or <� C !'
Glazing SHGC
Glazing U-Factor ./
R value of ductwork 6
A/C SEER rating
'4
(*hrqq*
CITY OF COLLEGE STATION
Planning d' Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
PLAN REVIEW/PERMIT NUMBER# 0 � _ S8-7
DATE: 3 / Z / o%
BUILDING ADDRESS: -ka.k S-DdLj%ne,
J
I. Foundation Requirements
NA/
A. Concrete minimum f'c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long then 30"
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
N K
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Narrow Wall Bracing Methods indicated on plans
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. Operable window
a. Twenty 20 inch clear width by twenty-four 24) inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. Operable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall.covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
1. If located in garage it is not to exceed 30" x 54"
M. Span exceeding code tables must be engineered
N. Rafters sizes, spacing, grade, slope and purlins if required.
CITY OF COLLEGE STATION
Planning c ' Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued)
O. Roof Covering
1. Roof Decking indicated on plans.
NA/
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs allowed on zero lot line construction up to 18"
S. Protected openings on walls < three feet from property line
T. One hour tenant separation to roof deck between duplexes
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform 3/8" Max. difference
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8"
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six (6-6") inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30") inches
above grade or finished floor
2. Handrails are required on stairways located four or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2") inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements (to be indicated on plans)
N
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward)
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at
least two 2 feet higher than any portion of the building within ten (10) feet horizontal
(*hr"�
CITY OF COLLEGE STATION
Planning d' Development Services
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
V. Electrical Service Requirements
NA
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel and Meter location
Vl. Plumbing Requirements
N K `
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Access to Bathtubs
C. Means for thermal expansion provided.
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment or 50' with 6' clearance
C. Combustion air supplied for gas appliances (when required)
VIII. Energy Requirements
N
A. Compliance software worksheet REScheck submitted, or
a. Energy data supplied (Percent of glazing, insulation R-values, window U-values,
etc.)
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Required parking
On zero lot side 18" max. overhang allowed
Street Ordinance Requirements
N
Maximum drive width for residence is 28' combined for circular
Minimum 20 feet from driveway to side(intersecting) street
Subdivision Regulations — Ordinance 690
AWW
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301
OK
Does not block any water course or divert any flow
Elevation certificate if required
IUA
CITY OF COLLEGE STATION
Planning 6 Development Services
Comments:
PLAN REVIEW
ONE and TWO FAMILY
OCCUPANCY REQUIREMENTS
1 I
PLANS EXAMINER DATE
I
REScheck Compliance Certificate
1995 MEC
REScheck Software Version 3.5 Release id
Data filename: C:\Program Files\Check\REScheck\SPRING MEADOW, LOT 35.rck
PROTECT TITLE: NEW RESIDENCE- LOT 35 BLK 3 -SPRING MEADOWS
CITY: Bryan (Brazos)
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 02/24/06
DATE OF PLANS: 2-20-2006
PROJECT DESCRIPTION:
PATIO HOME
414 ROCK SPRING COURT
LOT 35 BLK 3 SPRING MEADOWS SUBDIVISION
COLLEGE STATION, TX,
DESIGNER/CONTRACTOR:
T-2 PROPERTIES INC.
1700 BARAK LANE
BRYAN TEXAS 77802
COMPLIANCE: Passes
Maximum UA = 726
Your Home UA = 616
15.2% Better Than Code (UA)
Permit Number
Checked By/Date
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
Ceiling 1: Flat Ceiling or Scissor Truss
1716
30.0 0.0
Ceding 2: Cathedral Ceiling (no attic)
130
30.0 0.0
Ceiling 3: Cathedral Ceiling (no attic)
57
19.0 0.0
Ceiling 4: Cathedral Ceiling (no attic)
72
19.0 0.0
CeiMg 5: Flat Ceiling or Scissor Truss. w At t- Fwa1Wls 1hMG 210
13.0 0.0
Wall 1: Wood Frame, 16" o.c. - a F tom
20
13.0 0.0
Wall 2: Wood Frame, 16" o.c. X t1) ' li
680
13.0 0.0
Wall 3: Wood Frame, 16" o.c. % e tt •
1272
13.0 0.0
Window 1: Metal Frame, Double Pane with Low-E
30
Window 2: Metal Frame, Double Pane with Low-E
105
Window 3: Metal Frame, Double Pane with Low-E
53
Window 4: Metal Frame, Double Pane with Low-E
16
Window 5: Metal Frame, Double Pane with Low-E
4
Window: TRANSOM: Wood Frame, Double Pane with Low
3
60
4
3
4
15
2
56
82
0.590 18
0.590 62
0.590 31
0.590 9
0.590 2
0.590 2
I4i►a &O.TRl PTOM the;�jfr+ar +Doub��dn+e.'Wt1�a+ L4
e
Door 1: Solid is 0.140 2
Door 2: Glass 40 0.580 23
Floor 1: Unheated Slab -On -Grade 227 0.0 237
Insulation depth: 0.0'
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 1995 MEC
requirements in RES checkVersion 3.5 Release 1 d (formerly MEC chec4 and to comply with the mandatory requirements listed in
the REScheckInspection Checklist.
Builder/Designer� Date �, • `l �}�
REScheck Inspection Checklist
1995 MEC
REScheck Software Version 3.5 Release id
DATE: 02/24/06
PROJECT TITLE: NEW RESIDENCE- LOT 35 BLK 3 -SPRING MEADOWS
Bldg.
Dept.
Use
Ceiliags:
[ ] 1.
Ceiling L Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
[ ] 2.
Ceiling 2: Cathedral Ceiling (no attic), R-30.0 cavity insulation
Comments: LIVING
( ] 3.
Ceiling 3: Cathedral Ceiling (no attic), R 19.0 cavity insulation
Comments: STUDY
[ ] 4.
Ceiling 4: Cathedral Ceiling (no attic), R-19.0 cavity insulation
Comments: M BATH & B.R.
[ ] 5.
Ceiling 5: Flat Ceiling or Scissor Truss, R-13.0 cavity insulation
Comments: PONY WALLS FACING ATTIC
Above -Grade Walls:
[ ) 1.
Wall 1: Wood Frame, 16" o.c., R 13.0 cavity insulation
Comments: GABLE AREA
[ ] 2.
Wall 2: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
[ j 3.
Wall 3: Wood Frame, 16" o.c., R 13.0 cavity insulation
Comments:
i
Windows:
[ ] 1.
Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.590
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [
] No
Comments:
[ ] 2.
Window 2: Metal Frame, Double Pane with Low-E, U-factor: 0.590
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [
] No
Comments:
[ ) 3.
Window 3: Metal Frame, Double Pane with Low-E, U-factor: 0.590
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [
] No
Comments:
[ ] 4.
Window 4: Metal Frame, Double Pane with Low-E, U-factor: 0.590
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [
] No
Comments:
[ ] 5_
Window 5: Metal Frame, Double Pane with Low-E, U-factor: 0.590
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ) Yes [
] No
Comments:
[ ] 6.
Window: TRANSOM: Wood Frame, Double Pane with Low E, U-factor: 0.590
j
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [
) No
Comments: TRANSOM
T 1 1 7
UrnArmr TR AVIRM4• Mot*] Prom.. TlrwihlP Dann a„th T nw-R T T_&n tnr- n CQA
J For windows without labeled U-factors, describe features:
J # Panes Frame Type Thermal Break? [ J Yes [ ] No
J Comments: TRANSOM
I
J Doors:
[ ] j 1. Door 1: Solid, U-factor: 0.140
J Comments: GARAGE
[ J I 2. Door 2: Glass, U-factor: 0.580
J Comments: FRONT & REAR DRS.
I
Floors:
[ ] I 1. Floor 1: Unheated Slab -On -Grade, R-0 (uninsulated)
Comments:
I
Air Leakage:
[ ] J Joints, penetrations, and all other such openings in the building envelope that are sources of air
J leakage must be sealed.
[ J ( Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
3" clearance from insulation.
I
Materials Identification:
[ ] I Materials and equipment must be identified so that compliance can be determined.
{ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] ( Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications.
I
Duct Insulation:
[ ] I Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
I
Duct Construction:
[ ] j All ducts must be sealed with mastic and fibrous backing tape_ Pressure -sensitive tape may be used
J for fibrous ducts. Duct tape is not permitted.
[ ] I The HVAC system must provide a means for balancing air and water systems.
I
J Temperature Controls:
( J I Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
I
Circulating Hot Water Systems:
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
i
J Swimming Pools:
[ ] I All heated swimming pools must have an on/offheater switch and require a cover unless over 201/6
J of the heating energy is from non-depletable sources. Pool pumps require a time clock.
I ,
Heating and Cooling Piping Insulation:
[ ] J HVAC piping conveying fluids above 120 OF or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
Table l: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in
Inches by Pipe
Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature ( F)
Up to 1"
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Ifinimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness in Inches by
Pipe Sizes
Piping System Types
Range
2" Runouts
I" and Less
1.25" to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5