PREPARED 7/24/06, 12:08:40 INSPECTION TICKET PAGE 5
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/24/06
------------------------------------------------------------------------------------------------
ADDRESS . : 2301 AUTUMN CHASE LOOP SUBDIV:
TENANT, NBR: 2301-2303
CONTRACTOR SPIRIT CUSTOM HOMES PHONE (979) 268-3975
OWNER . . PHONE
PARCEL . . 18890-0004-0060
APPL NUMBER: 06-00000564 RESIDENTIAL, 2 UNITS NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 3/16/06 OC BLDG, FOUNDATION -SLAB TIME: 17:00
3/16/06 AP T/S: 04/05/2006 09:41 AM GLSOUTH -----------------------
T/S: 04/05/2006 09:41 AM GLSOUTH -----------------------
B115 01 5/04/06 DS BLDG, FRAMING TIME: 17:00
5/04/06 CA T/S: 05/04/2006 11:49 AM GLSOUTH -----------------------
05/04/2006 04:00 PM DS PDA
wrong address called
B115 02 5/22/06 JGM BLDG, FRAMING TIME: 17:00
5/23/06 AE May 22, 2006 11:37:21 AM bkorthauer
05/23/2006 08:22 AM JGM PDA
need to add anchors at proper spacing
Bl 0 01 5/23/06 DS BLDG, INSULATION TIME: 17:00
' 5/23/06 AP May 23, 2006 10:56:10 AM bkorthauer
late afternoon
B125 01 7L2A/06 BI _ BLDG, FINAL TIME: 1 :0
July 24, 2006 12:08:2 PM glsouth
---------�-----------------
W- ---- COMMENTS T --------------------------------------
ri
Date: 7/24/2006
Inspection Comments for Finals
Permit Year: 6 Permit Number: 564
Address: 2301 AUTUMN CHASE LOOP
Type
Inspection Type Code
Description
status
Inspection Result Comments
B100
BLDG, FOUNDATION -SLAB
IC
T/S: 04/05/2006 09:41 AM GLSOUTH -----------------------
B115
BLDG, FRAMING
IC
05/04/2006 04:00 PM IDS PDA
B115
BLDG, FRAMING
IC
wrong address called
B115
BLDG, FRAMING
IC
05/23/2006 08:22 AM JGM PDA
B115
BLDG, FRAMING
IC
need to add anchors at proper spacing
E150
ELEC, FINAL
IC
07/17/2006 11:15 AM RH PDA
E150
ELEC, FINAL
IC
Change bad arc fault in bedroom 2.
M100
MECH, ROUGH IN
IC
05/04/2006 04:02 PM DS PDA
M100
MECH, ROUGH IN
IC
wrong address
P100
PLBG, ROUGH IN
IC
T/S: 04/05/2006 09:42 AM GLSOUTH -----------------------
P125
PLBG, FINAL
IC
All Electric No Gas
Page 1
BUILDING PERMIT
CITY OF CODE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570`� FAX: (979) 764-3496
�.
----------------------------------------------------------------------------
Application Number . . . . .
Property Address . . . . . .
Property ID . . . . . . . . .
R #
Tenant nbr, name . . . . . .
Application type description
Subdivision Name . . . . . .
Property Use . . . . . . . .
Property Zoning . . . . . . .
Application valuation . . . .
-..Owner
------------------------
06-00000564 Date 3/20/06
2301 AUTUMN CHASE LOOP
18890-0004-0060
2301-2303
RESIDENTIAL, 2 UNITS NEW
RESIDENTIAL
DUPLEX RESIDENTIAL
164000
Contractor
SPIRIT CUSTOM HOMES
DAVID SHULER
PO BOX 305
WELLBORN TX 77881
(979) 268-3975
--- Structure Information 000 000 DUPLEX
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
HEATED AREA 2730.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 6.00
NUMBER OF BEDROOMS 6.00
SEWER TYPE PUBLIC
TAZ 285.00
----------------------------------------------------------------------------
Permit BUILDING PERMIT
Additional desc GS
Permit Fee . . . . 652.00 Plan Check Fee .00
Issue Date . . . . 3/20/06 Valuation . . . . 164000
Expiration Date . . 9/16/06
Qty Unit Charge Per Extension
BASE FEE 460.00
64.00 3.0000 THOU BLDG, VAL 100001-500000 192.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
--------------------------------------- - _R_ &'AOL
DEPT REPRESENTAT&.�,
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
or
Page 2
Application Number . . . . . 06-00000564 Date 3/20/06
----------------------------------------------------------------------------
Special Notes and Comments
X 301-) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
MAKE SURE TO INCLUDE REBAR SLAB GROUND
ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL
RESIDENTIAL CODE
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
-------------------------------------- - --------------------------
BUILDING DEPT REPRESENTATIVE: K
APPLICANT: ��_
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000564
Page 3
Date 3/20/06
Special Notes and Comments
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
Refer To This Permit For Details For This Plan
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
--------------------
-- - ---------------------------
BUILDING DEPT REPRESENTATIVE: '
APPLICANT: I)V
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
---------------------------------'=--- "--------------------------------------
Page 4
Application Number . . . . . 06-00000564 Date 3/20/06
----------------------------------------------------------------------------
Special Notes and Comments
Fully sheathed
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ----------
Permit Fee Total 652.00
Plan Check Total .00
Grand Total 652.00
1
652.00 .00 .00
.00 .00 .00
652.00 .00 .00
----------------------- - - ---------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: b�— S
APPLICATION FOR BUILDING PERMIT
For Office Use OMy
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEG E-STATION.TX.US
DATE
APPLICATION
TEMP POLE X
ADDRESS/LOCATION:_ Z301 - O 3 A1AUW►w" ekASQ1UQ
LOT � BLOCK _ SUBDIVISION A C, t/ L j/iOS SEC/PH
BUSINESS/OWNER NAME: PHONE: ago6 ") 7 / 14
CONTRACTOR/HOMEOWNER: P 6T 14 Om C S PHONE: G��r
CONTRACTOR ADDRESS: w e // LO r A) T�
ELECTRICIAN: Ir ` le AJ PLUMBER:
HVAC: LO MA 5 f`p/2 GOOD CENTS (Residential only): AVO
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL
Required)
DESCRIPTION OF WORK: ILk X
STRUCTURE USE: '�_"OAICA \ �yP
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: <-- —
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION:$ /64'VCIo TOTAL AREA. HEATED AREA: Z73 a
(Cost of Labor and Materials)
0 PUBLIC SEWER
NUMBER OF BEDROOMS:
❑ SEPTIC/TREATMENT SYSTEM
NUMBER OF BATHROOMS:
J SEWER TAP:
INTERIOR WALL TYPE:
SIZE
WATER TAP:
EXTERIOR WALL TYPE:
Sim
❑ OTHER TAP:
FOUNDATION TYPE:
SIZE
TEMP POLE
ROOF TYPE:
GARAGE TYPE:
SINGLE
DOUBLE F__j TRIPLE
ATTACHED
DETACHED n ,CARPORT
SIGNATURE OF APPLICANT:
4.
6
Z-r 4 os
Z- g za C_
S IA L I- Ne'k w�
a
a
♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦
Official Use Only
�oto� Sia(Q P ► Sc,teowL,•
ON L. fr - � 'ulel
Comments:
(.'j5,ir NO
Pam^ + A..6 iV U s`+
5-t&('A c
Energy Code Compliance Information
% Glazing of exterior walls �Z
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas) A -jp
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC , y
Glazing U-Factor . �5
R value of ductwork-�
AIC SEER rating 1�