Loading...
HomeMy WebLinkAbout06-553Date r Permit # Project Name COMMERCIAL CO Planning (Lindsay Boyer, Jennifer Prochazka, Jennifer Reeves, Crissy Hartl, Jason Schubert, Grant Wencel, Molly Hitchcock) Bridgette George Development Engineers (Alan Gibbs, Josh Norton, Carol Cotter) City Engineer (Bob Mosley, Jerry Jones, John Logan, Robert Bumpurs, William Ethridge) Environmental Services (Eaphrame Thomas, James Boykin, Pete Garcia) Fire Department (Eric Hurt, Eric Dotson, Jerry Duffey, Steve Smith) Drainage (Donnie Willis) Public Works - Sanitation (Wally Urrutia) Electrical Services (Tony Michalsky) Miscellaneous Notes City of College Station " 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning Owner . . . Contractor Application number Description of Work Construction type Occupancy type . Flood Zone . . . . Approved 9/26/07 000701-0104-0000 1725 HARVEY MITCHELL PKWY S BL 13 COLLEGE STATION TX 77840 CRAWFORD BURNETT (ICL) A000701 CRAWFORD BURNETT (ICL) , TRACT 104, ACRES 75.93 APARTMENT LOW DENSITY BUTLER, O D FAMILY DOVETAIL BUILDERS 706 357-9100 06-00000553 000 000 RESIDENTIAL, 5+ UNITS NEW COMBUSTIBLE (PROTECTED) RESIDENTIAL -MULTI -FAMILY . . . . . . . CJAI Building 40ficial VOID UNLESS SIGNED BY BUILDING OFFICIAL City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 T E M P O R A R Y C O T E M P O R A R Y Issue Date . . . . . . 8/10/07 Expiration Date . . . . 9/10/07 Parcel Number . . . . . 000701-0104-0000 Property Address . . . 1725 HARVEY MITCHELL PKWY S BL 13 COLLEGE STATION TX 77840 Subdivision Name . . . CRAWFORD BURNETT (ICL) Legal Description . . . A000701 CRAWFORD BURNETT (ICL) , TRACT 104, ACRES 75.93 Property Zoning . . . . APARTMENT LOW DENSITY Owner . . . . . . . . . BUTLER, O D FAMILY Contractor . . . . . . DOVETAIL BUILDERS 706 357-9100 Application number 06-00000553 000 000 Description of Work RESIDENTIAL, 5+ UNITS NEW Construction type . . . COMBUSTIBLE (PROTECTED) Occupancy type . . . . RESIDENTIAL -MULTI -FAMILY Flood Zone . . . . . . Special conditions . . Clear silt/dirt from parking area and sidewalk. Make sure any disturbed eart has sod/seed. Need backflow test report for domestic feed -multi storied and fireline test report. Install permanent labels on electrical panels. Approved . . . . . . . Cj n �4e Building Official VOID UNLESS SIGNED BY BUILDING OFFICIAL 1 (8/10/2007) Kim Wolfe - Re: Calling for C.O. for 1725 Harvey Mitchell bldg 13 Page 1 1 From: Lindsay Boyer To: Alan Gibbs; Amber Carter; Benjamin McCarty; Bob Mosley; Brian Wells;... Date: 8/10/2007 10:59 AM Subject: Re: Calling for C.O. for 1725 Harvey Mitchell bldg 13 Ok for temp CO. Needs to Clear silt/dirt from parking areas and sidewalk. Make sure any disturbed earth has sod/seed >>> Amber Carter 8/1/2007 3:22 PM >>> by #06-553 Woodlands of CS Building 13 any issues? contact Justin Randall with Dovetail @ 706-215-1868 �(8/9/2007) Kim Wolfe - Re: Calling for C.O. for 1725 Harvey Mitchell bldg 13 µ Page 11 From: Eaphrame Thomas To: Alan Gibbs; Amber Carter; Benjamin McCarty; Bob Mosley; Brian Wells;... Date: 8/2/2007 3:23 PM Subject: Re: Calling for C.O. for 1725 Harvey Mitchell bldg 13 CC: Eaphrame Thomas no for CO need backflow test report for domestic feed- multi storied on bldg. 13 and fireline test report. Eaphrame A. Thomas Environmental Technician Water Services Department Environmental Services 979.764.3662 Have A Wonderful Bless Day:) >>> Amber Carter Wednesday, August 01, 2007 3:22 pm >>> by #06-553 Woodlands of CS Building 13 any issues? contact Justin Randall with Dovetail @ 706-215-1868 (8/10/2007) Kim Wolfe - Re: Calling for C.O. for 1725 Harvey Mitchell bldg 13 Page 1 From: Lindsay Boyer To: Alan Gibbs; Amber Carter; Benjamin McCarty; Bob Mosley; Brian Wells;... Date: 8/10/2007 10:59 AM Subject: Re: Calling for C.O. for 1725 Harvey Mitchell bldg 13 Ok for temp CO. Needs to Clear silt/dirt from parking areas and sidewalk. Make sure any disturbed earth has sod/seed >>> Amber Carter 8/1/2007 3:22 PM >>> by #06-553 Woodlands of CS Building 13 any issues? contact Justin Randall with Dovetail @ 706-215-1868 PREPARED 8/01/07, 12:07:13 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/01/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 1725 HARVEY MITCHELL PKWY S BL 13 SUBDIV: CRAWFORD BURNETT (ICL) TENANT, NBR: APMT BLDG W/ 21 UNITS CONTRACTOR DOVETAIL BUILDERS PHONE (706) 357-9100 OWNER BUTLER, O D FAMILY PHONE : PARCEL 000701-0104-0000 APPL NUMBER: 06-00000553 RESIDENTIAL, 5+ UNITS NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS -=---------------------------------------------------------------------------------------------- B10d 01 1/25/07 DS BLDG, FOUNDATION -SLAB TIME: 17:00 1%25/07 AP January 25, 2007 10:49:27 AM ncochran. `I January 25, 2007 4:28:53 PM kwolfe. B115 01 3/28/07 DS BLDG, FRAMING TIME: 17:00 3/30/07 AP March 28, 2007 4:24:24 PM ncochran. B115 02 4/02/07 JGM BLDG, FRAMING TIME: 17:00 4/02/07 AP March 30, 2007 12:21:17 PM ncochran. LAST FRAMING 1ST FLOOR B130 01 4/03/07 DS BLDG, INSULATION TIME: 17:00 4/03/07 AP April 3, 2007 11:12:19 AM kwolfe. late afternoon B125 01 01/07 ;1 BLDG, FINAL TIME: 17:00 DC> August 1, 2007 10:28:49 AM acarter. F Am ------------------------------------- COMMENTS AND NOTES ------------------- -- ------- ---- r Date: 8/2/2007 Inspection Comments for Finals Permit Year: 6 Permit Number: 553 Address: 1725 HARVEY MITCHELL PKWY S Insp.Inspection Type Type Type Code Description Status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC January 25, 2007 4:28:53 PM kwolfe. Ell ELEC, ROUGH IN IC March 19, 2007 9:29:08 AM ncochran. E110 ELEC, ROUGH IN IC contractor called in Ell ELEC, ROUGH IN IC 03/19/2007 03:55 PM JGM PDA Ell ELEC, ROUGH IN IC need to remount boxes, finish kitchen circuit for first Ell ELEC, ROUGH IN IC floor unit, fire caulk penetrations, E150 ELEC, FINAL IC 06/29/2007 11:27 AM DS PDA E150 ELEC, FINAL IC not ready E150 ELEC, FINAL IC July 16, 2007 8:42:27 AM kwolfe. P105 PLBG, TOP OUT IC 03/27/2007 10:41 AM DS PDA P105 PLBG, TOP OUT IC per lance in the field (journyman on site) Page 1 WF0875618 / 001 Clty of College Station PAGE 1 REQ. DATE: 02/21/07 02/21/07 8:14:30 LOCATION: 1725 HARVEY MITCHELL PKWY S BL 13 LOC ID: 204882 REQUESTOR: DOVETAIL BUILDERS ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 02/21/07 SCHED COMPLETION: 02/21/07 ******************************************************************************** JOB ORDER RESULT COMVIENI'S WFO860871 / 001 City of College StA , ion PAGE 1 REQ. DATE: 12/28/06 _ a 12/28/06 11:31:30 LOCATION: 1725 HARVEY MITCHELL PKWY S 1311 LOC ID: 206154 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WFO860879 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 11:35:32 LOCATION: 1725 HARVEY MITCHELL PKWY S 1312 LOC ID: 206156 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0860908 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 11:48:00 LOCATION: 1725 HARVEY MITCHELL PKWY S 1313 LOC ID: 206158 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0860909 / 001 City o.f College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 11:48:25 LOCATION: 1725 HARVEY MITCHELL PKWY S 1314 LOC ID: 206166 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** Isto] :We]N9]:i:a Eli DMIJr twi[C6161mZm i WF0860910 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 11:48:51 LOCATION: 1725 HARVEY MITCHELL PKWY S 1315 LOC ID: 206160 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMI TI'S WFOB60911 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 11:49:16 LOCATION: 1725 HARVEY MITCHELL PKWY S 1316 LOC ID: 206162 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0860912 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 11:49:46 LOCATION: 1725 HARVEY MITCHELL PKWY S 1317 LOC ID: 206164 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0860913 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 11:50:17 LOCATION: 1725 HARVEY MITCHELL PKWY S 1321 LOC ID: 206170 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0860914 / 001 City bf College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 11:50:43 LOCATION: 1725 HARVEY MITCHELL PKWY S 1322 LOC ID: 206172 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COM U=S WFO860915 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 11:51:13 LOCATION: 1725 HARVEY MITCHELL PKWY S 1323 LOC ID: 206174 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT CONU#=S WFO860916 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 11:51:41 LOCATION: 1725 HARVEY MITCHELL PKWY S 1324 LOC ID: 206176 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0860917 / 001 City o`f College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 11:52:11 LOCATION: 1725 HARVEY MITCHELL PKWY S 1325 LOC ID: 206178 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMYIENrS WF0860918 / 001 City ?of College.Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 11:52:47 LOCATION: 1725 HARVEY MITCHELL PKWY S 1326 LOC ID: 206180 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMYIEhhTi'S WF0860919 / 001 City of Collp-ge Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 11:54:03 LOCATION: 1725 HARVEY MITCHELL PKWY S 1327 LOC ID: 206182 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMMI'S WF0860920 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 11:54:31 LOCATION: 1725 HARVEY MITCHELL PKWY S 1328 LOC ID: 206184 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0860924 / 001 City bf College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 11:55:01 LOCATION: 1725 HARVEY MITCHELL PKWY S 1329 LOC ID: 206186 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WFO860925 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 11:55:29 LOCATION: 1725 HARVEY MITCHELL PKWY S 1330 LOC ID: 206188 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WFO860928 / 001 �ity'of Col,lege.Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 11:55:59 LOCATION: 1725 HARVEY MITCHELL PKWY S 1331 LOC ID: 206190 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMYIE TI'S WFO860931 / 001 City 3f College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 11:56:30 LOCATION: 1725 HARVEY MITCHELL PKWY S 1332 LOC ID: 206192 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMV=S WF0860932 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 11:56:57 LOCATION: 1725 HARVEY MITCHELL PKWY S 1333 LOC ID: 206194 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMgENTS WFO860935 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 11:57:29 LOCATION: 1725 HARVEY MITCHELL PKWY S 1334 LOC ID: 206196 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS CITY OF COLLEGE STATION P(annina d development Services ADDRESS/LOCATION: LOT BLOCK APPLICATION FOR BUILDING PERMIT 1101 TEXAS AVtME_" COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CSTX.GOV 1-12s t ervtq 491 For Office Use Only DATE AT &CC REG APPLICATION # 1�3 TEMP POLE # 15, SUBDIVISION C%r.avfdrd .lUrr►e llv- SEC/PH BUSINESS/OWNER NAME: 4loodrIan As- of CL%goo :Solt! on, PHONE: 904—jS %- 9/00 CONTRACTOR/HOMEOWNER: %0oVe1o_,`1 %jy,'lVeLT, .t„c. PHONE: ��y-15'7- 9iob CONTRACTOR ADDRESS: /SSv 7, �Py,41,,, A4- J-u; le 20/ � ,6f4e,S, Gam- ELECTRICIAN: HVAC: PLUMBER: _ GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) Y NEW CONSTRUCTION DUPLEX (Landscape Plans) REMODEURENOVATIOW SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: /Uew coAx4rc1e-1,,a," ?sap; wowd 6-a'" e PROPOSED USE: Ar' -Soy /e Can .o,:h .'�:-s,.s- HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: I_ .. TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ �Z-p 7W,"VALUATION: $ i y' " 1,0'al,1OpTOTALAREA: 2Z e223 HEATED AREA: Z9 6S/ ! (Cost of Labor and Materials) Egi PUBLIC SEWER SEPTIC/TREATMENT TE SIZE y V l ✓] W, T f AP_ _ y --- ' — SIZE ❑ OTHER TAP: SIZE ❑ TEMP POLE �p va,✓ • GARAGE TYPE: SINGLE �At14- r ATTACHED !i, o NUMBER OF BEDROOMS: t0 NUMBER OF BATHROOMS: 4-7 INTERIOR WALL TYPE: /7/QPy tva EXTERIOR WALL TYPE: 47r! C- /( ono( / !'l�1- FOUNDATION TYPE: Sy, ! I�e/� ed ROOF TYPE: AS41, a DOUBLE TRIPLE DETACHED E:] CARPORT 6aa.-d/ /..,.., � SIGNATURE OF APPLICANT: /� 'l�Z • *If proposed work involves new commercial construction or facade improvements/renovations to an existing rb I11ornmercial property, building elevations are required. Official Use Only �f/ 1 t �/1 l n xa r Zoning Official Fire Marshall ments: P or NO nc _I TCQ 't Energy e0de Compliance Information.. % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork - . A/C SEER Rating .6 /j OT 2Q33114 R.'w3j,T?i �3�i BUILDING PERMIT CITY OF COLLEGE STATION 1101'TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number Property Address Property ID: R #. Tenant nbr name , . Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 06-00000553 Date 12/22/06 1725 HARVEY MITCHELL PKWY S BL 13 000701-0104-0000 R10473 APMT BLDG W/ 21 UNITS RESIDENTIAL, 5+ UNITS NEW CRAWFORD BURNETT (ICL) APARTMENT LOW DENSITY 1081188 Owner Contractor BUTLER, 0 D FAMILY DOVETAIL BUILDERS % BUTLER, JAMES 6010 1550 TIMOTHY RD STE 201 THOROUGHBRED RDG ATHENS GA 30606 COLLEGE STATION TX 778452324 (706) 357-9100 --- Structure Information 000 000 FIRE RATED STRUCTURAL PROTECTION Construction Type . . . . . COMBUSTIBLE (PROTECTED) Occupancy Type . . . . . . RESIDENTIAL -MULTI -FAMILY Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB HEATED AREA 28651.00 INTERIOR WALL TYPE DRYWALL NUMBER OF BATHROOMS 63.00 NUMBER OF BEDROOMS 63.00 SEWER TYPE PUBLIC TAZ 396.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit Fee . . . . 2824.00 Plan Check Fee .00 Issue Date . . . . 12/22/06 Valuation . . . . 1081188 Expiration Date . . 6/20/07 Qty Unit Charge Per Extension BASE FEE 1660.00 582.00 2.0000 THOU BLDG, VAL 500001 & UP 1164.00 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ADDRESS ON COMMERCIAL BUILDINGS -FRONT 5" NUMBERS REAR - 2" HIGH NUMBERS WITH NAME OF BUSINESS ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT ------------------------------- - ------ -- --------------- BUILDING DEPTcl�PRESENEYIVEI APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 'TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 06-00000553 Date 12/22/06 Special Notes and Comments INTERRUPTER(S) NOTE FROM WATER DEPT--REDUCED PRESSURE ASSEMBLY REQUIRED FOR CAR WASH, POSTMIX CARBONATER, AND HEATING/AC WITH DIRECT CONNECTION TO WATER SUPPLY AND LAWN IRRIGATION SYSTEMS. ALL DEVICES MUST BE TESTED UPON INSTALLATION BY CERTIFIED TESTER REGISTERED WITH THE CITY OF COLLEGE STATION PUBLIC UTILITIES DEPT. LAWN IRRIGATION MAY USE A PRESSURE VACCUM BREAKER INSTALLED PER AWWA STANDARDS AND CITY'S ORD #2394. ALL DEVICES MUST BE INSTALLED PER AWWA AND CITY'S ORD#2394 ELETRIC UTILITIES COMMENTS DEVELOPER INSTALLS CONDUIT PER CITY SPECS & DESIGN DEVELOPER PROVIDES TEMP BLANKET EASEMENT FOR CONSTRUCTION DEVELOPER POURS TRANSFORMER PAD PER CITY SPECS (IF NECESSARY) DEVELOPER PROVIDES 30' RIGID CONUDIT FOR RISER POLE (IF NECESSARY) DEVELOPER INSTALLS FIRST 10' OF CONDUIT ON RISER POLE. CITY INSTALLS REMAINING 201. DEVELOPER PROVIDES EASEMENTS FOR ELECTRIC INFRASTRUCTURE AS INSTALLED FOR ELECTRIC LINES. DEVELOPER PROVIDES DIGITAL SITE PLAN IN AUTOCADE 14 VERSION. EMAIL TO RBOLIN@CI.COLLEGE-STATION.TX.US DEVELOPER IS REPSONSIBLE FOR THE INSTALLATION OF SERVICE FROM TRANSFORMER TO BUILDING FOR QUESTIONS CONTACT RONNIE BOLIN AT 979-764-3614 PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Electrical conduit installation shall be installed per city specs and is the responsibility of the owner and/or contractor. Contact the electrical division at (979) 764- 6314 for more information. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELEVATION CERTIFICATE REQUIRED - PROVIDE ELEVATION CERTIFICATE PRIOR TO SLAB INSPECTION AND A SECOND ------ -- - ------------------ ------------------------ --- BUILDING DEPT REPRESENTA'I\VE: I APPLICANT: BUILDING PERMIT CITY_OF COLLEGE STATION `1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 06-00000553 Date 12/22/06 ---------------------------------------------------------------------------- Special Notes and Comments CERTIFICATE PRIOR TO FINAL INSPECTION/C.O. ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR REQUIRED EXIT DOOR(S) SUBMIT FIRE ALARM PLANS WITH PRODUCT DATA SHEETS - DESIGN AND INSTALL AS PER NFPA 72 NO WORK SHALL START UNTIL PLANS HAVE BEEN REVIEWED AND RETURNED PROVIDE FIRE EXTINGUISHER(S) - VERIFY LOCATION AND PLACEMENT WITH THE FIRE MARSHALL'S OFFICE (MIN. 2A10BC) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND SUBMIT FIRE SPRINKLER PLANS AND CALCULATIONS FOR REVIEW NO WORK ON SPRINKLER SYSTEM SHALL BEGIN UNTIL PLANS HAVE BEEN REVIEW AND RETURNED. SPRINKLER SYSTEM CONTROLS AND WATER FLOW SWITCHES ARE REQUIRED TO BE MONITORED BY AN APPROVED MONITORING COMPANY. A COPY OF THE MONITORING CONTRACT SHALL BE SENT TO THE COLLEGE STATION FIRE DEPARTMENT, FIRE PREVENTION DIVISION. GUARDS SHALL COMPLY WITH SECTION R-312 (2003 IRC) OR SECTION 1012 IN (2003 IBC) AS APPROPRIATE Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit PROVIDE MINIMUM 42" CLEARANCE FROM CENTER OF WATER CLOSET TO EDGE OF LAVATORY HANDRAILS SHALL COMPLY WITH SECTION R-311 (2003 IRC) OR SECTION 1009 (2003 IBC) AS APPROPRIATE INTERIOR BEAMS > 60' MUST BE A MINIMUM OF 30" DEEP PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION PROVIDE A KNOX BOX FOR FIRE DEPARTMENT ACCESS. IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT All outdoor lighting must be in compliance with Section 7.10, Outdoor lighting Standards of the City's Unified Development Ordinance --------------------------------- ----------- ---------------- BUILDING DEPT RARESENTATI4: A -: %7� APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 41101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 4 Application Number . . . . . 06-00000553 Date 12/22/06 ---------------------------------------------------------------------------- Special Notes and Comments All roof and ground -mounted mechanical equipment shall be sreened from view or isolated so as not to be visible from any public right-of-way or residential district within 150 feet of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. Acceptable methods of screening rooftop equipment may include, but are not limited to encasement, parapet walls, or partition screens. COLLEGE STATION ELECTRICAL DIVISION REQUESTS THAT THE METER CAN/ELECTRICAL SERVICE DISCONNECT BE LOCATED ON THE STRUCTURE AS CLOSE AS POSSIBLE TO THE SECONDARY FEEDER CONDUIT FROM THE TRANSFORMER. (see site plan for location of conduit or contact electrical division) BE AWARE - SEWER MANHOLE/WATER VALVE ON PROPERTY - DO NOT COVER - CONTACT WATER & WASTEWATER @ PUBLIC UTILITIES 764-3660 (PETE GARCIA) FOR ADDITIONAL INFORMATION CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND 7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA) ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE PROJECTIONS (OVERHANGS) BEYOND THE EXTERIOR WALL SHALL COMPLY WITH ORDINANCE NO. 2713 AND CHAPTER 12 AMENDMENTS TO THE U.D.O. AND EXHIBITS "A", "B", AND "C". WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 5 Application Number . . . . . 06-00000553 Date 12/22/06 ---------------------------------------------------------------------------- Special Notes and Comments exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL PUBLIC SEWER SERVICE IS PROVIDED OR APPROVED ALTERNATE SEWER SYSTEM IS INSTALLED SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 ---------------C---- ------- G DEPT R ESENTABUILDINI APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 6 Application Number 06-00000553 Date 12/22/06 ---------------------------------------------------------------------------- Special Notes and Comments IRC) RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK PROVIDE FIRE -RATED PROTECTION BETWEEN UNITS AND AT REQUIRED LOCATIONS FOR STRUTURAL PROTECTION REQUIRED BY TYPE VA CONSTRUCTION, SEE PLANS FOR ROOF AND STRUCTURAL PROTECTION. PROVIDE FIRE DAMPERS FOR ALL DUCTS THAT PENETRATE A FIRE OR SMOKE RATED ASSEMBLY. STAIRWAYS OUTSIDE OF DWELLING UNITS SHALL HAVE A MAXIMUM RISER HEIGHT OF 7" AND A MINIMUM TREAD WIDTH OF 11". ---------------------------------------------------------------------------- Other Fees . . . . . . . . . WATER TAP 3/4" 8400.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ------------------------------ --------------------------- Permit Fee Total 2824.00 2824.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 8400.00 8400.00 .00 .00 Grand Total 11224.00 11224.00 .00 .00 -----A�� -------------------- ------------------ - BUILDING DEPT RE ESENTA IVh: t— APPL