HomeMy WebLinkAbout06-552WF0875617 / 001 City of College Station
PAGE 1
REQ. DATE:
02/21/07
�i�`�
02/21/07
8:13:51
LOCATION:
1725 HARVEY MITCHELL PKWY S
BL 6
LOC ID:
203952
REQUESTOR:
DOVETAIL BUILDERS
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
TEMP POLE
PASSED
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
02/21/07 SCHED
COMPLETION:
02/21/07
********************************************************************************
JOB ORDER RESULT COMMENTS
PREPARED 7/30/07, 12:07:56
INSPECTION TICKET
PAGE 7
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 7/30/07
------------------------------------------------------------------------------------------------
ADDRESS
. : 1725 HARVEY MITCHELL PKWY S BL 6 SUBDIV: CRAWFORD BURNETT
(ICL)
TENANT,
NBR: APMT BLDG W/ 27 UNITS
CONTRACTOR DOVETAIL BUILDERS
PHONE (706) 357-9100
OWNER
BUTLER, O D FAMILY
PHONE
PARCEL
000701-0104-0000
APPL NUMBER: 06-00000552 RESIDENTIAL, 5+ UNITS NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B115 01
3/21/07 JGM
BLDG, FRAMING TIME: 17:00
3/22/07 AE
March 21, 2007 10:51:43 AM glsouth.
03/22/2007 12:14 PM JGM PDA
need draft stop in party wall between 2nd and
3rd unit
first floor, fire caulk all penetrations through top plate
B130 01
3/23/07 JGM
BLDG, INSULATION TIME: 17:00
3/23/07 CA
March 23, 2007 11:17:48 AM glsouth.
y,
03/23/2007 04:02 PM JGM PDA
not ready
B130 02
3/26/07 DS
BLDG, INSULATION TIME: 17:00
3/26/07 AP
March 26, 2007 8:09:50 AM ncochran.
B125 01
�
,/
7/30/07 a \
BLDG, FINAL TIME: 17:00
my 26, 2007 4:24:02 PM malford.
-------- COMMENTS AND NOTES--------
WF0860422
/ 001 City of College
Station
PAGE 1
REQ. DATE:
12/27/06 ��
-
12/27/06
16:21:43
LOCATION:
1725 HARVEY MITCHELL PKWY S
BL 6
LOC ID:
203952
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
6" SWR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START: 12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER
RESULT COMMENTS
11
WF0860424 / 001 City of College Station
PAGE 1
REQ. DATE:
12/27/06 y
12/27/06
16:22:39
LOCATION:
1725 HARVEY MITCHELL PKWY S
611
LOC ID:
206072
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WFOB60425 / 001 City of College Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:23:13
LOCATION:
1725 HARVEY MITCHELL PKWY S
612
LOC ID:
206074
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4 " WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0860426 / 001 City of College Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:23:49
LOCATION:
1725 HARVEY MITCHELL PKWY S
613
LOC ID:
206076
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0860427 / 001 City of College Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:24:27
LOCATION:
1725 HARVEY MITCHELL PKWY S
614
LOC ID:
206078
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMIENTS
WF0860432 / 001 City of College Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:25:11
LOCATION:
1725 HARVEY MITCHELL PKWY S 615
LOC ID:
206080
REQUESTOR:
DOVETAIL BUILDERS, INC ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
12/27/06 SCHED COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0860434 / 001 City of College Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:25:48
LOCATION:
1725 HARVEY MITCHELL PKWY S
616
LOC ID:
206082
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0860435 / 001 City of College Station
PAGE
REQ. DATE:
12/27/06
12/27/06
16:26:20
LOCATION:
1725 HARVEY MITCHELL PKWY S
617
LOC ID:
206084
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMMEbTI'S
WF0860436 / 001 City of College Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:26:57
LOCATION:
1725 HARVEY MITCHELL PKWY S
618
LOC ID:
206086
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COM4ENTS
WF0860437 /
001 City of College
Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:27:29
LOCATION:
1725 HARVEY MITCHELL PKWY S
619
LOC ID:
206088
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0860439 / 001 City of College Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:28:25
LOCATION:
1725 HARVEY MITCHELL PKWY S 621
LOC ID:
206090
REQUESTOR:
DOVETAIL BUILDERS, INC ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
12/27/06 SCHED COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COME24TS
WFO860442 / 001 City of College Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:30:56
LOCATION:
1725 HARVEY MITCHELL PKWY S
622
LOC ID:
206092
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMMENTS
0
WF0860443 /
001 City of College
Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:31:32
LOCATION:
1725 HARVEY MITCHELL PKWY S
623
LOC ID:
206094
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0860444 / 001 City of College Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:32:10
LOCATION:
1725 HARVEY MITCHELL PKWY S
624
LOC ID:
206096
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0860445 / 001 City of College Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:32:40
LOCATION:
1725 HARVEY MITCHELL PKWY S
625
LOC ID:
206098
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0860446 / 001 City of College Station
PAGE
REQ. DATE:
12/27/06
12/27/06
16:33:28
LOCATION:
1725 HARVEY MITCHELL PKWY S
626
LOC ID:
206100
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0860451 /
001 City of College
Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:35:01
LOCATION:
1725 HARVEY MITCHELL PKWY S
627
LOC ID:
206102
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0860456 / 001 City of College Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:35:37
LOCATION:
1725 HARVEY MITCHELL PKWY S
628
LOC ID:
206104
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COW ENTS
WFO860457 / 001 City of College Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:36:09
LOCATION:
1725 HARVEY MITCHELL PKWY S 629
LOC ID:
206106
REQUESTOR:
DOVETAIL BUILDERS, INC ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER: KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT SET
READY
SCHED START:
12/27/06 SCHED COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COM 094TS
WFO860462 / 001 City of College Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:40:24
LOCATION:
1725 HARVEY MITCHELL PKWY S
630
LOC ID:
206108
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0860463 /
001 City of College
Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:40:56
LOCATION:
1725 HARVEY MITCHELL PKWY S
631
LOC ID:
206110
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0860464 / 001 City of College Station
PAGE
REQ. DATE:
12/27/06
12/27/06
16:41:27
LOCATION:
1725 HARVEY MITCHELL PKWY S
632
LOC ID:
206112
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0860465 /
001 City of College
Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:41:59
LOCATION:
1725 HARVEY MITCHELL PKWY S
633
LOC ID:
206114
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0860466 / 001 City of College Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:42:26
LOCATION:
1725 HARVEY MITCHELL PKWY S
634
LOC ID:
206116
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COM14ENTS
WF0860467 / 001 City of College Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:42:57
LOCATION:
1725 HARVEY MITCHELL PKWY S
635
LOC ID:
206118
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0860470 /
001 City of College
Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:43:32
LOCATION:
1725 HARVEY MITCHELL PKWY S
636
LOC ID:
206120
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMVE TI'S
WF0860471 / 001 City of College Station
PAGE 1
REQ. DATE:
12/27/06
12/27/06
16:44:04
LOCATION:
1725 HARVEY MITCHELL PKWY S
637
LOC ID:
206122
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMMENTS
WF0860472 /
001 City of College
Station
PAGE 1
REQ. DATE:
12/27/06 '1
12/27/06
16:44:37
LOCATION:
1725 HARVEY MITCHELL PKWY S
638
LOC ID:
206124
REQUESTOR:
DOVETAIL BUILDERS, INC
ORIGIN:
CUSTOMER -WALK IN
REQ. USER:
KWOLFE AUTH. USER:
KWOLFE
WORK TYPE:
ROUT
3/4" WTR
TAP
********************************************************************************
TASK:
SET UP NEW UTILITY ACCT
SET
READY
SCHED START:
12/27/06 SCHED
COMPLETION:
12/27/06
********************************************************************************
JOB ORDER RESULT COMMENTS
APPLICATION FORBUILDING PERMIT
1101 TEXAS AVENUE'
COLLEGE STATION, TX 77840 '
(979) 764-3570 (979) 764-3496 FAX
CITY OF COLLEGE STATION WWW.CSTX.GOV l
plammmdC'Development Services
�� For
Ofce Use Only
DATE: A Ij•�N/1�itCCCRRjEG� 1
APPLICATION # Vli! 015 G_
ADDRESS/LOCATION: o f fln ZISZ/ 9io zen- k1d �/
LOT BLOCK SUBDIVISION CZ2r01',gr-j ffbrne h�- SEC/PH
BUSINESS/OWNER NAME: Wood 4n ✓.S` of CoL%aB PHONE:
CONTRACTOWHOMEOWNER: 40Ve1Za,e1 �u�'l�ers� Z„C. PHONE: '7'9Ao11'
CONTRACTOR ADDRESS: /STu T,�7ro�AV Rom✓,. S 'lc Lo/ ; .+lfti�i=S, Grz ,ToGuG
IF
ELECTRICIAN:
HVAC:
PLUMBER:
_ GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION "
DUPLEX (Landscape Plans) REMODEL/RENOVATION SWIMMING POOL
TENT/CANOPY
DESCRIPTION OF WORK: /flew conx4r ele, ,'a" ; ,?r-1vrW wdrie/
PROPOSED USE: /Aar- -So, Canes A71
_ HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
3 6. va TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 7, , OTAL AREA: y2, y� HEATED AREA. � k�7
(Cost of Lab �r andMaterials) S6
POOL PUBLIC SEWER �� NUMBER OF BEDROOMS: SI
1 _ _ 1 ❑ SEPTIC/TREATMENT STEM NUMBER OF BATHROOMS:
INTERIOR WALL TYPE: Dp)e tv'a
SIZE /�
EXTERIOR WALL TYPE: 1—?r G K ho/J. 4Onerc��
SIZE
❑ OTHER TAP:
❑ TEMP POLE
GARAGE TYPE:
V'e'G-1 a
FOUNDATION TYPE: 1v4' f'fe/+c,c!
SIZE
ROOF TYPE:
SINGLE ❑ DOUBLE ❑ TRIPLE ❑
ATTACHED ❑ DETACHED ❑ CARPORT ❑
g 07 SIGNATURE OF APPLICANT: /.<� /4 -e�
k I 'If proposed work involves new commercial construction or facade improvements/renovations to al existing
1,10commercial property, building elevations are required.
r
f
Official Use Only
Plans Examiner _ Zoning Official Fire Marshall
N
ents:
YES rN0
,e-
LL e
PARKL D DED ON
F UE
S �
Energy'Code Compliance Information '
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value o£ductwork.:.._,
A/C SEER Rating
,6
-L
, Z! " ; J`
8033V
R 3TOD P r y l
BUILDING PERMIT
CITY,OF COLLEGt" STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number . . . .
Property Address . . . . .
Property ID:
R #.
Tenant nbr, name . . . . .
Application type description
Subdivision Name . . . . .
Property Use . . . . . . .
Property Zoning . . . . . .
Application valuation . . .
06-00000552 Date 12/22/06
1725 HARVEY MITCHELL PKWY S BL 6
000701-0104-0000
R10473
APMT BLDG W/ 27 UNITS
RESIDENTIAL, 5+ UNITS NEW
CRAWFORD BURNETT (ICL)
APARTMENT LOW DENSITY
1527156
Owner Contractor
BUTLER, O D FAMILY OWNER
% BUTLER, JAMES 6010
THOROUGHBRED RDG
COLLEGE STATION TX 778452324
--- Structure Information 000 000 FIRE RATED STRUCTURAL PROTECTION
Construction Type . . . . . COMBUSTIBLE (PROTECTED)
Occupancy Type . . . . . . RESIDENTIAL -MULTI -FAMILY
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
HEATED AREA 36837.00
INTERIOR WALL TYPE DRYWALL
NUMBER OF BATHROOMS 81.00
NUMBER OF BEDROOMS 81.00
SEWER TYPE PUBLIC
TAZ 396.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . GS
Permit Fee . . . . 3716.00 Plan Check Fee .00
Issue Date . . . . 12/22/06 Valuation . . . . 1527156
Expiration Date . . 6/20/07
Qty Unit Charge Per Extension
BASE FEE 1660.00
1028.00 2.0000 THOU BLDG, VAL 500001 & UP 2056.00
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ADDRESS ON COMMERCIAL BUILDINGS -FRONT 5" NUMBERS
REAR - 2" HIGH NUMBERS WITH NAME OF BUSINESS
ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
--------------- ----b
---------------------------
BUILDING DEPT RRESENTVEi //s'�
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 06-00000552 Date 12/22/06
----------------------------------------------------------------------------
Special Notes and Comments
INTERRUPTER(S)
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY
Permit Number provided by the COCS shall be conspicuously
posted in the lower right hand corner of the banner.
Shall be mounted parallel to the face of a building or
permanent structure.
Shall advertise only the name of, uses of, or goods or
services available within the building or tenant lease
space to which the banner is attached.
Shall not be located within public road ROW (State or
Local) .
Shall not obstruct any window, door, stairway, or other
opening inteded for ingress or for needed ventilation or
light.
Shall not exceed the top of the structure to which it is
attached.
Shall advertise only the name of, uses of, or goods or
services available within the building, or tenant lease
space, to which the banner is attached.
Shall be mounted parallel to the face of the building.
Shall not be cantilevered away from the structure.
Shall not extend more than one foot from any exterior
building face, mansard, awning, or canopy.
Shall not obstruct any window, door, stairway, or other
opening intended for ingress or for needed ventilation or
light.
Shall not be attached to any tree, fence, or public utility
pole.
NOTE FROM WATER DEPT--REDUCED PRESSURE ASSEMBLY REQUIRED FOR
CAR WASH, POSTMIX CARBONATER, AND HEATING/AC WITH DIRECT
CONNECTION TO WATER SUPPLY AND LAWN IRRIGATION SYSTEMS.
ALL DEVICES MUST BE TESTED UPON INSTALLATION BY CERTIFIED
TESTER REGISTERED WITH THE CITY OF COLLEGE STATION PUBLIC
UTILITIES DEPT. LAWN IRRIGATION MAY USE A PRESSURE VACCUM
BREAKER INSTALLED PER AWWA STANDARDS AND CITY'S ORD #2394.
ALL DEVICES MUST BE INSTALLED PER AWWA AND CITY'S ORD#2394
ELETRIC UTILITIES COMMENTS
DEVELOPER INSTALLS CONDUIT PER CITY SPECS & DESIGN
DEVELOPER PROVIDES TEMP BLANKET EASEMENT FOR CONSTRUCTION
DEVELOPER POURS TRANSFORMER PAD PER CITY SPECS
(IF NECESSARY)
--------------------------------------- -- ---------------
BUILDING DEPTH PRES N AT�VE:
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number
06-00000552
Page 3
Date 12/22/06
Special Notes and Comments
DEVELOPER PROVIDES 30' RIGID CONUDIT FOR RISER POLE
(IF NECESSARY)
DEVELOPER INSTALLS FIRST 10' OF CONDUIT ON RISER POLE.
CITY INSTALLS REMAINING 201.
DEVELOPER PROVIDES EASEMENTS FOR ELECTRIC INFRASTRUCTURE
AS INSTALLED FOR ELECTRIC LINES.
DEVELOPER PROVIDES DIGITAL SITE PLAN IN AUTOCADE 14
VERSION. EMAIL TO RBOLIN@CI.COLLEGE-STATION.TX.US
DEVELOPER IS REPSONSIBLE FOR THE INSTALLATION OF SERVICE
FROM TRANSFORMER TO BUILDING
FOR QUESTIONS CONTACT RONNIE BOLIN AT 979-764-3614
PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS
METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED
SILL PLATES
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE
Electrical conduit installation shall be installed per
city specs and is the responsibility of the owner and/or
contractor. Contact the electrical division at (979) 764-
6314 for more information.
ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical
Code & LOCAL AMENDMENTS
ELEVATION CERTIFICATE REQUIRED - PROVIDE ELEVATION
CERTIFICATE PRIOR TO SLAB INSPECTION AND A SECOND
CERTIFICATE PRIOR TO FINAL INSPECTION/C.O.
ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL
PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
REQUIRED EXIT DOOR(S)
SUBMIT FIRE ALARM PLANS WITH PRODUCT DATA SHEETS - DESIGN
AND INSTALL AS PER NFPA 72
NO WORK SHALL START UNTIL PLANS HAVE BEEN REVIEWED AND
RETURNED
PROVIDE FIRE EXTINGUISHER(S) - VERIFY LOCATION AND PLACEMENT
WITH THE FIRE MARSHALL'S OFFICE (MIN. 2A10BC)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
-------- --------------
--------------- ---------- --- ---------------
BUILDING DEPT R PRES TAT)VE : �� `/�`�'
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000552
Page 4
Date 12/22/06
Special Notes and Comments
MAKE SURE TO INCLUDE REBAR SLAB GROUND
SUBMIT FIRE SPRINKLER PLANS AND CALCULATIONS FOR REVIEW
NO WORK ON SPRINKLER SYSTEM SHALL
BEGIN UNTIL PLANS HAVE BEEN REVIEW AND RETURNED.
SPRINKLER SYSTEM CONTROLS AND WATER FLOW SWITCHES ARE
REQUIRED TO BE MONITORED BY AN APPROVED MONITORING
COMPANY. A COPY OF THE MONITORING CONTRACT SHALL BE
SENT TO THE COLLEGE STATION FIRE DEPARTMENT, FIRE
PREVENTION DIVISION.
GUARDS SHALL COMPLY WITH SECTION R-312 (2003 IRC) OR
SECTION 1012 IN (2003 IBC) AS APPROPRIATE
Assure Proper GFI Locations, Including One Within 25' Of
Outside A/C Unit
PROVIDE MINIMUM 42" CLEARANCE FROM CENTER OF WATER CLOSET TO
EDGE OF LAVATORY
HANDRAILS SHALL COMPLY WITH SECTION R-311 (2003 IRC) OR
SECTION 1009 (2003 IBC) AS APPROPRIATE
PROTECTION FROM IMPACT - APPLIANCES LOCATED IN A GARAGE
OR CARPORT SHALL BE PROTECTED FROM IMPACT BY AUTOMOBILES
INTERIOR BEAMS > 60' MUST BE A MINIMUM OF 30" DEEP
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
PROVIDE A KNOX BOX FOR FIRE DEPARTMENT ACCESS.
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
All outdoor lighting must be in compliance with Section
7.10, Outdoor lighting Standards of the City's Unified
Development Ordinance
All roof and ground -mounted mechanical equipment shall be
sreened from view or isolated so as not to be visible from
any public right-of-way or residential district within 150
feet of the subject lot, measured from a point five feet
above grade. Such screening shall be coordinated with the
building architecture and scale to maintain a unified
appearance. Acceptable methods of screening rooftop
equipment may include, but are not limited to encasement,
parapet walls, or partition screens.
COLLEGE STATION ELECTRICAL DIVISION REQUESTS THAT THE METER
CAN/ELECTRICAL SERVICE DISCONNECT BE LOCATED ON THE
STRUCTURE AS CLOSE AS POSSIBLE TO THE SECONDARY FEEDER
---------- ------------------------i� -------------------
BUILDING DEPT P ESENTIVE:I
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 5
Application Number . . . . . 06-00000552 Date 12/22/06
----------------------------------------------------------------------------
Special Notes and Comments
CONDUIT FROM THE TRANSFORMER.
(see site plan for location of conduit or contact
electrical division)
CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND
7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA)
ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN,
STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE
ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS
BEEN DONE TO ALLOW FOR COVER-UP
MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET
NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION
R602.10 IN 2003 IRC
PROVIDE PANIC HARDWARE ON EXIT DOORS
If PEX water supply piping is sleeved below the slab, seal
annular space at ends with caulk, foam or other means.
ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE
RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO
ASSURE CODE COMPLIANCE
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR
DUCTS, CEILING FANS AND RETURN AIR
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
BUILDING L
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 6
Application Number . . . . . 06-00000552 Date 12/22/06
----------------------------------------------------------------------------
Special Notes and Comments
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A
CONTINUOUS HANDRAIL OR SECTION
1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL
NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A
NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS.
WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE
TEMPERED GLASS
TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN
ADJACENT WALLS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND
LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003
IRC)
RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC
ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST
BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING
DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK
PROVIDE FIRE -RATED PROTECTION BETWEEN UNITS AND AT REQUIRED
LOCATIONS FOR STRUTURAL PROTECTION REQUIRED BY TYPE VA
CONSTRUCTION, SEE PLANS FOR ROOF AND STRUCTURAL PROTECTION.
PROVIDE FIRE DAMPERS FOR ALL DUCTS THAT PENETRATE A FIRE OR
SMOKE RATED ASSEMBLY.
STAIRWAYS OUTSIDE OF DWELLING UNITS SHALL HAVE A MAXIMUM
RISER HEIGHT OF 7" AND A MINIMUM TREAD WIDTH OF 11".
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 6" 100.00
WATER TAP 3/4" 10800.00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ----------
Permit Fee Total 3716.00
Plan Check Total .00
3716.00 .00
.00 .00
------------------------------------------- ------------- ----------------
BUILDING DEPT REPRESENTATIVE-
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 06-00000552
Other Fee Total 10900.00 10900.00
Grand Total 14616.00 14616.00
------------------------------
BUILDING DEPT REPRESENT IVE :'
APPLICANT:
Page 7
Date 12/22/06
.00 .00
.00 .00