HomeMy WebLinkAbout06-551WF0861153 / 001 City of College�Station - PAGE REQ. DATE: 12/28/06 12/28/06 15:13:22 LOCATION: 1725 HARVEY MITCHELL PKWY S 2011 LOC ID: 206202 REQUESTOR: DOVETAIL BUILDERS, INC p ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0861154 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 15:14:01 LOCATION: 1725 HARVEY MITCHELL PKWY S 2012 LOC ID: 206200 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0861155 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 15:14:30 LOCATION: 1725 HARVEY MITCHELL PKWY S 2013 LOC ID: 206198 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WFO861156 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 15:15:05 LOCATION: 1725 HARVEY MITCHELL PKWY S 2014 LOC ID: 206168 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0861157 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 15:15:44 LOCATION: 1725 HARVEY MITCHELL PKWY S 2021 LOC ID: 206204 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0861159 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 15:16:24 LOCATION: 1725 HARVEY MITCHELL PKWY S 2022 LOC ID: 206206 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0861160 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 15:16:52 LOCATION: 1725 HARVEY MITCHELL PKWY S 2023 LOC ID: 206208 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COM41ENTS WFO861161 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 15:17:22 LOCATION: 1725 HARVEY MITCHELL PKWY S 2024 LOC ID: 206210 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WFO861162 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 15:18:09 LOCATION: 1725 HARVEY MITCHELL PKWY S 2025 LOC ID: 206212 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WFO861164 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 15:19:23 LOCATION: 1725 HARVEY MITCHELL PKWY S 2026 LOC ID: 206214 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WFO861165 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 15:19:50 LOCATION: 1725 HARVEY MITCHELL PKWY S 2027 LOC ID: 206216 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS WF0861166 / 001 City of College Station PAGE 1 REQ. DATE: 12/28/06 12/28/06 15:20:20 LOCATION: 1725 HARVEY MITCHELL PKWY S 2028 LOC ID: 206218 REQUESTOR: DOVETAIL BUILDERS, INC ORIGIN: CUSTOMER -WALK IN REQ. USER: KWOLFE AUTH. USER: KWOLFE WORK TYPE: ROUT 3/4" WTR TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 12/28/06 SCHED COMPLETION: 12/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS PREPARED 7/30/07, 12:07:56 INSPECTION TICKET PAGE 6 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/30/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 1725 HARVEY MITCHELL PKWY S BL 20 SUBDIV: CRAWFORD BURNETT (ICL) TENANT, NBR: APMT BLDG W/ 12 UNITS CONTRACTOR DOVETAIL BUILDERS PHONE (706) 357-9100 OWNER BUTLER, 0 D FAMILY PHONE PARCEL 000701-0104-0000 APPL NUMBER: 06-00000551 RESIDENTIAL, 5+ UNITS NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B115 01 3/02/07 DS BLDG, FRAMING TIME: 17:00 3/02/07 AP March 2, 2007 11:41:29 AM ncochran. B130 01 3/08/07 DS BLDG, INSULATION TIME: 17:00 3/08/07 AP March 8, 2007 11:31:07 AM glsouth. B125 01 7/30/07 BLDG, FINAL TIME: 17:00 July 26, 2007 4:24:56 PM malford. --------------------------- W----- COMMENTS AND NOTES -------------------------------------- n APPLICATtON*FOR BUILDING PERMIT 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX CITY OF COLLEGE STATION VVM.CSTX.GOV Liq 1' ij For Of ke Use Only DATE ' A T "OCC RE'GG APPLICATION # ND 4 qV TEMP POLE # Planning& DevelopmentSerncu 1�jZ�j ��!� �Q� Jt, ADDRESS/LOCATION:__-Z7n �ersecvti -wn a f Fiy1 2IS�/ �,,../ Fiy1JZ�/S ,(%/dc LOT BLOCK SUBDIVISION _CmwMrl?e SEC/PH BUSINESS/OWNER NAME: 4/bod fah k of` GoL/eag :iol ��anL,F' PHONE: 9'09%7S 7- 9/on V CONTRACTOR/HOMEOWNER: f aye l4a /4� .Z- PHONE: 4'0'f CONTRACTOR ADDRESS: /SSu T,:,-e -/,v %u,Ju,'1e Zo/ , ,�ftie�s, G� -�oG C ELECTRICIAN: PLUMBER: HVAC: GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION DUPLEX (Landscape Plans) REMODEURENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: _/yew conx-Arele V,bri, .?S wdd� s�'iame PROPOSED USE: :y, •'ay.,s * HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ �� mo VALUATION: $ Z�b(D TOTAL AREA: HEATED AREA: (0 37L (Cost of Labor and Materials) T� 9 PUBLIC SEWER / SEPTIC/TREATMENT T M SIZE SIZE OTHER TAP: SIZE ❑ TEMP POLE ✓e GARAGE TYPE: Pa/!L N F&e Bo NUMBER OF BEDROOMS: �J NUMBER OF BATHROOMS: INTERIOR WALL TYPE: %,/+y W. EXTERIOR WALL TYPE: /.?r! G K 4n d A-tr'd i / oasra/l %►' FOUNDATION TYPE: SY, > 'e"'-e ROOF TYPE: AS /P4 •� j► Cr SINGLE F--1 DOUBLE TRIPLE ATTACHED F7 DETACHED CARPORT 60 N' SIGNATURE OF APPLICANT: /sue /� l f �!/ *If proposed work involves new commercial construction or facade improvements/renovations to an existing ocommercial property, building elevations are required. Official Use Only N Zoning Official jeumiRe YES o NO Fire Marshall PARK D D CI F DUE 5111 q Energy Code Compliance Information ' % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork ;.,.. A/C SEER Rating .6 OT 80331, AV R3T81iD3Hj` BUILDING PERMIT CITY OF,COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Property Address . . . . . . Property ID: R ## : Tenant nbr, name . . . . . . Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 06-00000551 Date 12/22/06 1725 HARVEY MITCHELL PKWY S BL 20 000701-0104-0000 R10473 APMT BLDG W/ 12 UNITS RESIDENTIAL, 5+ UNITS NEW CRAWFORD BURNETT ( I CL ) APARTMENT LOW DENSITY 679536 Owner Contractor BUTLER, 0 D FAMILY DOVETAIL BUILDERS % BUTLER, JAMES 6010 1550 TIMOTHY RD STE 201 THOROUGHBRED RDG ATHENS GA 30606 COLLEGE STATION TX 778452324 (706) 357-9100 --- Structure Information 000 000 FIRE RATED STRUCTURAL PROTECTION Construction Type . . . . . COMBUSTIBLE (PROTECTED) Occupancy Type . . . . . . RESIDENTIAL -MULTI -FAMILY Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB HEATED AREA 16372.00 INTERIOR WALL TYPE DRYWALL NUMBER OF BATHROOMS 36.00 NUMBER OF BEDROOMS 36.00 SEWER TYPE PUBLIC TAZ 396.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . GS Permit Fee . . . . 2020.00 Plan Check Fee .00 Issue Date . . . . 12/22/06 Valuation . . . . 679536 Expiration Date . . 6/20/07 Qty Unit Charge Per Extension BASE FEE 1660.00 180.00 2.0000 THOU BLDG, VAL 500001 & UP 360.00 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ADDRESS ON COMMERCIAL BUILDINGS -FRONT 5" NUMBERS REAR - 2" HIGH NUMBERS WITH NAME OF BUSINESS ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT ----------------- BUILDING APPLICAN'I BUILDING PERMIT CITY OF -COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 06-00000551 Date 12/22/06 ---------------------------------------------------------------------------- Special Notes and Comments INTERRUPTER(S) NOTE FROM WATER DEPT--REDUCED PRESSURE ASSEMBLY REQUIRED FOR CAR WASH, POSTMIX CARBONATER, AND HEATING/AC WITH DIRECT CONNECTION TO WATER SUPPLY AND LAWN IRRIGATION SYSTEMS. ALL DEVICES MUST BE TESTED UPON INSTALLATION BY CERTIFIED TESTER REGISTERED WITH THE CITY OF COLLEGE STATION PUBLIC UTILITIES DEPT. LAWN IRRIGATION MAY USE A PRESSURE VACCUM BREAKER INSTALLED PER AWWA STANDARDS AND CITY'S ORD 42394. ALL DEVICES MUST BE INSTALLED PER AWWA AND CITY'S ORD#2394 ELETRIC UTILITIES COMMENTS DEVELOPER INSTALLS CONDUIT PER CITY SPECS & DESIGN DEVELOPER PROVIDES TEMP BLANKET EASEMENT FOR CONSTRUCTION DEVELOPER POURS TRANSFORMER PAD PER CITY SPECS ( IF NECESSARY) DEVELOPER PROVIDES 30' RIGID CONUDIT FOR RISER POLE (IF NECESSARY) DEVELOPER INSTALLS FIRST 10' OF CONDUIT ON RISER POLE. CITY INSTALLS REMAINING 201. DEVELOPER PROVIDES EASEMENTS FOR ELECTRIC INFRASTRUCTURE AS INSTALLED FOR ELECTRIC LINES. DEVELOPER PROVIDES DIGITAL SITE PLAN IN AUTOCADE 14 VERSION. EMAIL TO RBOLIN@CI.COLLEGE-STATION.TX.US DEVELOPER IS REPSONSIBLE FOR THE INSTALLATION OF SERVICE FROM TRANSFORMER TO BUILDING FOR QUESTIONS CONTACT RONNIE BOLIN AT 979-764-3614 PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE Electrical conduit installation shall be installed per city specs and is the responsibility of the owner and/or contractor. Contact the electrical division at (979) 764- 6314 for more information. ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELEVATION CERTIFICATE REQUIRED - PROVIDE ELEVATION CERTIFICATE PRIOR TO SLAB INSPECTION AND A SECOND BUILDING DE APPLICANT: BUILDING PERMIT CITY OF -COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 06-00000551 Date 12/22/06 ---------------------------------------------------------------------------- Special Notes and Comments CERTIFICATE PRIOR TO FINAL INSPECTION/C.O. ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR REQUIRED EXIT DOOR(S) SUBMIT FIRE ALARM PLANS WITH PRODUCT DATA SHEETS - DESIGN AND INSTALL AS PER NFPA 72 NO WORK SHALL START UNTIL PLANS HAVE BEEN REVIEWED AND RETURNED PROVIDE FIRE EXTINGUISHER(S) - VERIFY LOCATION AND PLACEMENT WITH THE FIRE MARSHALL'S OFFICE (MIN. 2A10BC) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND SUBMIT FIRE SPRINKLER PLANS AND CALCULATIONS FOR REVIEW NO WORK ON SPRINKLER SYSTEM SHALL BEGIN UNTIL PLANS HAVE BEEN REVIEW AND RETURNED. SPRINKLER SYSTEM CONTROLS AND WATER FLOW SWITCHES ARE REQUIRED TO BE MONITORED BY AN APPROVED MONITORING COMPANY. A COPY OF THE MONITORING CONTRACT SHALL BE SENT TO THE COLLEGE STATION FIRE DEPARTMENT, FIRE PREVENTION DIVISION. GUARDS SHALL COMPLY WITH SECTION R-312 (2003 IRC) OR SECTION 1012 IN (2003 IBC) AS APPROPRIATE Assure Proper GFI Locations, Including One Within 25' Of Outside A/C Unit HANDRAILS SHALL COMPLY WITH SECTION R-311 (2003 IRC) OR SECTION 1009 (2003 IBC) AS APPROPRIATE INTERIOR BEAMS > 60' MUST BE A MINIMUM OF 30" DEEP PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION PROVIDE A KNOX BOX FOR FIRE DEPARTMENT ACCESS. IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT All outdoor lighting must be in compliance with Section 7.10, Outdoor lighting Standards of the City's Unified Development Ordinance All roof and ground -mounted mechanical equipment shall be sreened from view or isolated so as not to be visible from ------------------- -- ------ -- --------------------------- BUILDING DEPT RESENTA IVE- APPLICANT: BUILDING PERMIT CITY OF -COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 4 Application Number . . . . . 06-00000551 Date 12/22/06 ---------------------------------------------------------------------------- Special Notes and Comments any public right-of-way or residential district within 150 feet of the subject lot, measured from a point five feet above grade. Such screening shall be coordinated with the building architecture and scale to maintain a unified appearance. Acceptable methods of screening rooftop equipment may include, but are not limited to encasement, parapet walls, or partition screens. COLLEGE STATION ELECTRICAL DIVISION REQUESTS THAT THE METER CAN/ELECTRICAL SERVICE DISCONNECT BE LOCATED ON THE STRUCTURE AS CLOSE AS POSSIBLE TO THE SECONDARY FEEDER CONDUIT FROM THE TRANSFORMER. (see site plan for location of conduit or contact electrical division) CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND 7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA) ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR ------------------------------------------- ------------------------------ BUILDING DEPT R ESENTA XE: G APPLICANT: BUILDING PERMIT CITY OF -COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 5 Application Number . . . . . 06-00000551 Date 12/22/06 ---------------------------------------------------------------------------- Special Notes and Comments DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL PUBLIC SEWER SERVICE IS PROVIDED OR APPROVED ALTERNATE SEWER SYSTEM IS INSTALLED SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. STAIRS SHALL COMPLY WITH SECTION R-311 (2003 IRC) WITH A CONTINUOUS HANDRAIL OR SECTION 1009 (2003 IBC) AS APPROPRIATE, CONTINUOUS HANDRAIL NEEDED, ENDS SHALL BE RETURNED OR SHALL TERMINATE INTO A NEWEL POST OR SAFETY TERMINAL ON COMMERCIAL JOBS. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE PER R308.4 GLAZING ADJACENT TO STAIRWAYS WITHIN 36" AND LESS THAN 60" ABOVE WALKING SURFACE MUST BE TEMPERED (2003 IRC) RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK PROVIDE FIRE -RATED PROTECTION BETWEEN UNITS AND AT REQUIRED LOCATIONS FOR STRUTURAL PROTECTION REQUIRED BY TYPE VA CONSTRUCTION, SEE PLANS FOR ROOF AND STRUCTURAL PROTECTION. ------------------------------------------ ------------------------- BUILDING DEPT R RESE IVF �t APPLICANT: BUILDING PERMIT CITY OF•COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Page 6 Application Number . . . . . 06-00000551 Date 12/22/06 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE FIRE DAMPERS FOR ALL DUCTS THAT PENETRATE A FIRE OR SMOKE RATED ASSEMBLY. STAIRWAYS OUTSIDE OF DWELLING UNITS SHALL HAVE A MAXIMUM RISER HEIGHT OF 7" AND A MINIMUM TREAD WIDTH OF 11". ---------------------------------------------------------------------------- Other Fees . . . . . . . . . WATER TAP 3/4" 4800.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 2020.00 2020.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4800.00 4800.00 .00 .00 Grand Total 6820.00 6820.00 .00 .00 ------------ BUILDING DEPT RFJPRES APPLICANT: --------------- ----------------- �T I `