Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
06-545
m va[wv4�mRi'� — i, . —--------__ -- 0� -5d�1 -- Gina'Southerland - Re: Calling@0 CldsprngDr Page 1„ _._ r� From: Mitchell Carson To: Benjamin McCarty; Chris Haver; Gina Southerland; Joe Garcia; Kim Wolfe; Nicole Cochran; Paul Schoenfeld; Terry Boriskie Date: 2/5/2007 12:48:39 PM Subject: Re: Calling for CO @ 410 Cold spring Dr Everything looks good. mitch >>> Kim Wolfe 02/05/07 8:29 AM >>> Are there any issues? BP # 06-545 Thanks Kimberly Wolfe, CPS City of College Station Planning & Development Services (979) 764-3570 www.cstx.gov PREPARED 2/02/07, 12:04:18 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/02/07 ------------------------------------------------------------------------------------------------ ADDRESS . : 410 COLD SPRING DR SUBDIV: SPRING MEADOWS PH 2 CONTRACTOR SOUTHERN ESTATE HOMES PHONE (979) 690-9096 OWNER WOODLAND HILLS DEVELOPMENT LTD PHONE PARCEL 582830-0203-0160 APPL NUMBER: 06-00000545 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 3/16/06 RH BLDG, FOUNDATION -SLAB TIME: 17:00 3/16/06 AP March 16, 2006 10:44:36 AM bkorthauer early afternoon 03/16/2006 02:44 PM RH PDA Strings up and slab ground installed. B115 01 5/10/06 JGM BLDG, FRAMING TIME: 17:00 5/10/06 AE May 10, 2006 11:29:43 AM bkorthauer 05/10/2006 03:40 PM JGM PDA add joist hanger in dining room B130 01 5/16/06 RH BLDG, INSULATION TIME: 17:00 5/16/06 DP May 16, 2006 11:47:15 AM bkorthauer 05/16/2006 03:36 PM RH PDA STOP BRICKING NOW! Need to seal all penetrations through top plates and exterior walls. Also, need to move smoke detectors that are to close to a/c grilles as noted in previous inspec n. B130 02 5/17/06 BI TIME: 17:00--1n� May 17, 2006 9:07:49 AM kwolfe B125 01 2/02/07 B -;BLDG,—FI_NAL TIME:-17:00 February 2, 2007 11:52:06 AM kwolfe. �) / 0,7 —44;�v --------------------------t -------- COMMENTS AND NOTES -------------------------------------- �o Date: 2/5/2007 Inspection Comments for Finals Permit Year: 6 Permit Number: 545 Address: 410 COLD SPRING DR Insp. inspection Type Code Status Inspection Result Comments B100 BLDG, FOUNDATION -SLAB IC 03/16/2006 02:44 PM RH PDA B100 BLDG, FOUNDATION -SLAB IC Strings up and slab ground installed. B115 BLDG, FRAMING IC 05/10/2006 03:40 PM JGM PDA B115 BLDG, FRAMING IC add joist hanger in dining room B130 BLDG, INSULATION IC 05/16/2006 03:36 PM RH PDA B130 BLDG, INSULATION IC STOP BRICKING NOW! Need to seal all penetrations through B130 BLDG, INSULATION IC top plates and exterior walls. Also, need to move smoke B130 BLDG, INSULATION IC detectors that are to close to a/c grilles as noted in B130 BLDG, INSULATION IC previous inspection. Ell ELEC, ROUGH IN IC 05/10/2006 03:40 PM JGM PDA Ell ELEC, ROUGH IN IC smoke detectors in bedrooms need proper clearance P105 PLBG, TOP OUT IC 04/20/2006 03:48 PM JGM PDA P105 PLBG, TOP OUT IC need work pllatform and walkway by final Page 1 WF0749726 / 001 City of College Stationh" PAGE 1 9-( REQ. DATE: 03/01/06 `J 03/01/06 11:04:54 LOCATION: 410 COLD SPRING DR LOC ID: 199438 REQUESTOR: SOUTHERN ESTATE HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: GLSOUTH AUTH. USER: GLSOUTH WORK TYPE: ROUT TEMP POLE PASSED ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 03/01/06 SCHED COMPLETION: 03/01/06 ******************************************************************************** JOB ORDER RESULT COMIEIQ'I'S /47 ,�//D C0�D sR i ag 5 Lo-F /N s r'n ii\/G CITY OF COLLEGE STATION Planning d- Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS PLAN REVIEW/PERMIT NUMBER# o( 5�5 1 DATE: lxyl66 BUILDING ADDRESS: Z/!D CoIG( S,ou„Gs I. Foundation Requirements N A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long then 30" 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements N K A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Narrow Wall Bracing Methods indicated on plans E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. Operable window a. Twenty 20 inch clear width by twenty-four (24) inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. Operable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans 1. If located in garage it is not to exceed 30" x 54" M. Span exceeding code tables must be engineered N. Rafters sizes, spacing, grade, slope and purlins if required. CITY OF COLLEGE STATION Planning d' Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS II. Framing: Floor, Wall, Ceiling and Roof Requirements (continued) O. Roof Covering 1. Roof Decking indicated on plans. NA/ 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs allowed on zero lot line construction up to 18" S. Protected openings on walls < three feet from property line T. One hour tenant separation to roof deck between duplexes JJ bt III. Stairway Requirements OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 3/8" Max. difference 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6'-8" B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six (6-6") inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30") inches above grade or finished floor 2. Handrails are required on stairways located four or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2") inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) NA/09 A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials C. Chimneys must extend at least three (3) feet higher than the highest point of roof & at least two 2 feet higher than any portion of the building within ten 10 feet horizontal (*hrq" CITY OF COLLEGE STATION Planning d Development Services PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS V. Electrical Service Requirements NA/ A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel and Meter location VI. Plumbing Requirements NA/ A. Pressure reducing valve required when water pressure exceeds 80 psi B. Access to Bathtubs C. Means for thermal expansion provided. D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements N A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment or 50' with 6' clearance C. Combustion air supplied for gas appliances (when required) Vill. Energy Requirements N A. Compliance software worksheet REScheck submitted, or a. Energy data supplied (Percent of glazing, insulation R-values, window U-values, etc.) Zoning Ordinance Requirements — Ordinance 850 NA Permitted use for district Density requirements Minimum lot size Setbacks Easements Required parking On zero lot side 18" max. overhang allowed Street Ordinance Requirements NXM Maximum drive width for residence is 28' combined for circular Minimum 20 feet from driveway to side(intersecting) street Subdivision Regulations — Ordinance 690 NA/ Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 OK Does not block any water course or divert any flow Elevation certificate if required Pr CITY OF COLLEGE STATION Planning cr Development Services Comments: JWIIML- PLANS EXAMINER PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS -9-$ -o DATE r ._ t ,-i Permit Number MECcheck Compliance Report 2000 IECC MECcheck Software Version 3.2 Release lb Checked By/Date TITLE: 410 cold springs CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 02/27/06 DATE OF PLANS: 1/27/06 COMPANY INFORMATION: Southern Estate Homes, Inc. COMPLIANCE: Passes Maximum UA = 644 Your Home = 188 70.8% Better Than Code Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 2344 30.0 30.0 40 Wall 1: Wood Frame, 16" o.c. 1953 13.0 0.0 121 Window 1: Metal Frame with Thermal Break, Double Pane with Low-E 422 0.058 24 Door 1: Solid 56 0.060 3 Furnace 1: Forced Hot Air, 95 AFUE Air Conditioner 1: Electric Central Air, 14 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calcul ' s submitted with the permit application. The proposed building has been designed to me�the CC r uirements in M check rsion 3.2 Release lb. -'. Builder/Desi Date n MECcheck Inspection Checklist 2000 IECC MECcheck Software Version 3.2 Release lb DATE: 02/27/06 TITLE: 410 cold springs Bldg. Dept. Use I Ceilings: [ ] I 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity + R-30.0 continuous insulation Comments: I Above -Grade Walls: [ ] I 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: 1. Window 1: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.058 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 1: Solid, U-factor: 0.060 Comments: Heating and Cooling Equipment: 1. Furnace 1: Forced Hot Air, 95 AFUE or higher Make and Model Number 2. Air Conditioner 1: Electric Central Air, 14 SEER or higher Make and Model Number I [ ] I The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. I Air Leakage: [ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation. Materials Identification: [ ] I Materials and equipment must be installed in accordint to the manufacturer's installation instructions. [ ] I Materials and equipment must be identified so that compliance can be determined. [ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] I Insulation R-values, glazing U-values, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastsnQd with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. ©uc; tape is not permitted. Exception: Continuously welded and locking -type longitudinal' jaintsand seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: HVAQiknqgawweying fluids above 105 OF or chilled fluids below 55 °F must be insulated to the Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulatina Mains and Runouts Temperature ( F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Ran e F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) WF0749303 / 001 City of College Station PAGE 1 REQ. DATE: 02/28/06 02/28/06 12:06:39 _LOCATION: 410 COLD SPRING DR LOC ID: 199438 REQUESTOR: SOUTHERN ESTATE HOMES ORIGIN: CUSTOMER -WALK IN REQ. USER: BKORTHAUER AUTH. USER: BKORTHAUER WORK TYPE: ROUT 4" SEWER TAP AND 3/4" WATER TAP ******************************************************************************** TASK: SET UP NEW UTILITY ACCT SET READY SCHED START: 02/28/06 SCHED COMPLETION: 02/28/06 ******************************************************************************** JOB ORDER RESULT COMMENTS City of College Station 1101 TEXAS AVENUE COLLEGE STATION TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning Owner . . . . . Contractor Application number Description of Work Construction type . . . Occupancy type . . . . Flood Zone . . . . . . 2/08/07 582830-0203-0160 410 COLD SPRING DR COLLEGE STATION TX 77845 SPRING MEADOWS PH 2 SPRING MEADOWS #2, BLOCK 3, LO T 16 SINGLE FAMILY RESIDENTIAL WOODLAND HILLS DEVELOPMENT LTD SOUTHERN ESTATE HOMES 979 690-9096 06-00000545 000 000 RESIDENTIAL, 1 UNIT DETACHED NEW COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX Ll Approved . . . . . . . VOID UNLESS SIGNED BY BUILDING OFFICIAL BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Property Address . . . . . . Property ID: R #• Application type description Subdivision Name . . . . . . Property Use . . . . . . . . Property Zoning . . . . . . . Application valuation . . . . 06-00000545 Date 2/28/06 410 COLD SPRING DR 582830-0203-0160 R116894 RESIDENTIAL, 1 UNIT DETACHED NEW SPRING MEADOWS PH 2 RESIDENTIAL SINGLE FAMILY RESIDENTIAL 205000 Owner Contractor ------------------------ WOODLAND HILLS DEVELOPMENT ------------------------ LTD SOUTHERN ESTATE HOMES 1700 BARAK LN NOBLE HANDY BRYAN TX 778023311 PO BOX 10231 COLLEGE STATION TX 77840 (979) 690-9096 --- Structure Information 000 000 SINGLE FAMILY Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 3.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2262.00 INTERIOR WALL TYPE SHEET ROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC TAZ 410.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . BK Permit Fee . . . . 775.00 Plan Check Fee .00 Issue Date . . . . 2/28/06 Valuation . . . . 205000 Expiration Date . . 8/27/06 Qty Unit Charge Per Extension BASE FEE 460.00 105.00 3.0000 THOU BLDG, VAL 100001-500000 315.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY OUTLETS IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) ---------------- BUILDING APPLICAN' BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 Application Number . . . . . 06-00000545 Page 2 Date 2/28/06 Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) WITHIN 20' OF THE MECHANICAL EQUIPMENT AND WALKWAY PROVIDE CHEMICAL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ALL METHODS MUST BE USED IN CONJUNCTION WITH TREATED SILL PLATES PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2003 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 2002 National Electrical Code & LOCAL AMENDMENTS ELECTRIC STRIP HEATING NOT ALLOWED FOR RESIDENTIAL PROPERTIES WITH FLOOR AREA GREATER THAN 500 Sq. FEET MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) MAKE SURE TO INCLUDE REBAR SLAB GROUND ALL FRAMING SHALL COMPLY WITH 2O03 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT ON NARROW WALL BRACING WHERE SPECIAL NAILING PATTERN, STRAPPING BETWEEN STORIES, OR HOLD DOWNS ARE REQUIRED THESE ITEMS MUST REMAIN VISIBLE UNTIL THE INSPECTION PROCESS HAS BEEN DONE TO ALLOW FOR COVER-UP MUST INDICATE METHODS ON FLOOR PLAN TO BE USED TO MEET NARROW WALL BRACING REQUIREMENTS PER IRC CODE SECTION R602.10 IN 2003 IRC If PEX water supply piping is sleeved below the slab, seal annular space at ends with caulk, foam or other means. ANY CHANGES OR ALTERATIONS TO SUBMITTED PLANS MUST BE RESUBMITTED AND APPROVED BEFORE WORK IS DONE IN ORDER TO ASSURE CODE COMPLIANCE BUILDING E APPLICANT: BUILDING PERMIT CITY OF QOLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 06-00000545 Page 3 Date 2/28/06 Special Notes and Comments POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE Refer To This Permit For Details For This Plan PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS SMOKE DETECTORS MUST HAVE 3' CLEARANCE FROM FORCED AIR DUCTS, CEILING FANS AND RETURN AIR PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS WITHIN 60" ABOVE DRAIN SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED IN WINDOWS WITHIN 24" OF DOORS IN ADJACENT WALLS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE RANGE/DRYER DUCT MUST COMPLY WITH 2O03 IMC ALL PLUMBING, ELECTRICAL, AND HVAC (mechanical) WORK MUST BE PERFORMED BY LICENSED CONTRACTORS. CONTACT BUILDING DEPARTMENT FOR INSPECTIONS PRIOR TO COVERING ANY WORK Narrow wall bracing Fully Sheathed with modified garage to achieve 24" minimums on each side of garage openings. ---------------------------------------------------------------------------- -----Other -Fees . . . . . . . . . SEWER T------------350�00----- ---------------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF gOLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 4 Application Number . . . . . 06-00000545 Date 2/28/06 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . WATER TAP 3/4" 400.00 ---------------------------------------------------------------------------- Fee summary Charged ---------- Paid Credited -------------------- Due ---------- ----------------- Permit Fee Total 775.00 775.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1525.00 1525.00 .00 .00 --------------------------------------------- /-`-AS----------------------- BUILDING.DEPT REPRES-FWTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 06-00000547 Date 2/28/06 Property Address . . . . . . 410 COLD SPRING DR Property ID: 582830-0203-0160 R #: R116894 Application type description TEMP POLE Subdivision Name . . . . . . SPRING MEADOWS PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ WOODLAND HILLS DEVELOPMENT LTD ------------------------ SOUTHERN ESTATE HOMES 1700 BARAK LN NOBLE HANDY BRYAN TX 778023311 PO BOX 10231 COLLEGE STATION TX 77840 (979) 690-9096 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . BK Permit Fee . . . . 20.00 Issue Date . . . . 2/28/06 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 ---------------------------------------------------------------------------- Fee summary ----------------- Charged ---------- Paid Credited ------------------------------ Due Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ---------------- BUILDING APPLICIU For Office Use On y APPLICATION FOR BUILDING PERMIT DATE: � � � REG 1101 TEXAS AVENUE --s COLLEGE STATION, TX 77840 APPLICATION # (979) 764-3570 (979) 764-3496 FAX TEMP POLE # ' —LC-A E CITY OF COLLEGE STATION WWW.CSTX.GOV Planning & DevelopmentServicei ADDRESS/LOCATION: �40 cz, Gy s��ia-� ✓ LOT _/ �BLOCK V�SUB--DIVISION SEC/PH BUSINESS/OWNER NAME:.::2�; T• ,OL-) �S �- HONE: CONTRACTOR/HOMEOWNER: PHONE: U % Z —V-00 CONTRACTOR ADDRESS: ELECTRICIAN: ��� /� G PLUMBER: HVAC: �4 vG �� GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF ADDITION M VING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTIONSLAB ONLY DUPLEX (Landscape Plans) REMODEL/RENOVATION* SWIMMING POOL TENT/CANOPY DESCRIPTION OF WORK: PROPOSED USE: HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ Z-vS , C, �✓ TOTAL AREAZ3 HEATED AREA: �� (Cost of Lab r and Materials) gkPUs c SEWER ❑ SEPTIC/TREATMENT SYSTEM SEWER TAP: SIZE WATER TAP: slzE OTHER TAP: SIZE P_fEMP POLE GARAGE TYPE: SINGLE F1 NUMBER OF BEDROOMS NUMBER OF BATHROOMS: INTERIOR WALL TYPE EXTERIOR WALL TYPE: FOUNDATION TYPE ROOF TYPE: DOUBLE F7 IETACHED n s4��' .-I- co-�- -,5r7 TRIPLE ©_— SIGNATURE OF APPLICANT; //s2 *If proposed work involve commercial construction or fa5pd commercial property, bul ding elevations are required. Official Use Only iF% e Plans Examiner Zoning Official �/ S �ments: ►���yr� � /Ywol/�J� YE r NO s to an existing s Fire Marshall Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC t� Glazing U-Factor R value of ductwork A/C SEER Rating 4 /�Z