Loading...
HomeMy WebLinkAboutRES2003-00988PREPARED 3/01/04, 7:58:33 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 3/01/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 1104 TYLER CT SUBDIV: ALEXANDRIA PH 5 CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER FROEHLING, EDWARD PHONE PARCEL 106500-0505-0790 APPL NUMBER: 03-00000988 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/22/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00 4/22/03 AP 04/21/2003 12:10 PM LLONG 04/22/2003 11:44 AM SSTANLEY STRINGS ON SETBACKS OK. SLAB GROUND BACK LEFT SIDE. B j 01 7/10/03 DS BLDG, FRAMING TIME: 17:00 7/10/03 AP 07/10/2003 11:51 AM KELMENDORF SHEETROCK TOP OF FIREPLACE JOIST HANGER RETURN AIR B13Q O1 7/17/03 CH BLDG, INSULATION TIME: 17:00 7/17/03 AP B125 01 3/01/0 I BLDG, FINAL TIME: 17:00 02/27/2004 09:22 AM SSTANLEY -------------------------------------- COMMENTS AND NOTES----------- CITY OF COLLEGE STATION WOP ZEQUEST PAGE 1 REQ/JOB: WF0391018 •/ 001 PROJECT: REQUEST DATE: 4/11/03 PRINT DATE: 4/11/03 CREW: PRINT TIME: 10:58:17 SCHEDULE LOCATION: 1104 TYLER CT START:DATES 4/11/03 77845 COMPLETION: 4/11/03 GEN. LOC: COLLEGE STATION LOC ID: 196516 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ED FROEHLING ORIGIN: CUSTOMER -WALK IN USER ID: KELMENDORF AUTH: KELMENDORF WORK TYPE: ROUTINE 3/4" WATER 4" SEWER ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 3/4" WATER 4" SEWER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- BUILDING PERMIT CITY OF COLLEGE STATIO COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00000988 Date 4/07/03 Property Address . . . . . . 1104 TYLER CT Property ID 106500-0505-0790 R # . . . . . . R114185 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . ALEXANDRIA PH 5 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 122034 Owner Contractor ------------------------ FROEHLING, EDWARD ------------------------ ED FROEHLING BUILDERS 3887 HIGH LONESOME ED FROEHLING COLLEGE STATION TX 778459443 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL -MULTI -FAMILY Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1849.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KE Permit Fee . . . . 529.00 Plan Check Fee .00 Issue Date . . . . 4/07/03 Valuation . . . . 122034 Expiration Date . . 10/04/03 Qty Unit Charge Per Extension BASE FEE 460.00 23.00 3.0000 THOU BLDG, VAL 100001-500000 69.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT BUILDING DEPT REPRESEN ATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATIO 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00000988 Date 4/07/03 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited Due ---------------------------------------- ----------------- Permit Fee Total 529.00 529.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1279.00 1279.00 .00 .00 ----------------------------------------------------- ---- -------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US Fa Office Use QMy DATE: _V APPLICATION # TEMP POLE # ADDRESS/LOCATION: jJ09 TyGE%z- z_-eug, LOT ----�/ / BLOCK _S SUBDIVISION '&--e xAa wu .- BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: ga FgpEJ+L./,&24 1�c ILpEp_ [A)C-. PHONE: %%6 f3266 CONTRACTOR ADDRESS: 09_7 IC,� L©�►L ,5o171 �L ELECTRICIAN: 13kg c.E�.7',e/c. PLUMBER: 1g/ Pi-e wS pz-o/i,ty'u HVAC: _: ' G ).y.unVh'l / VE S E.2 VtGjfS GOOD CENTS (Residential only): iV lA CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL DESCRIPTION OF WORK: STRUCTURE USE: 41,o4l E F4171 iy 2e51 D"e-AE HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: /V IAI TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ 1 VALUATION: $ / Z Z ©3 q TOTAL AREA:?�R HEATED AREA: i R4 2 (Cost of Labor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 2-- E SEWER TAP: �ATER TAP: ❑ OTHER TAP: SIZE TEMP POLE GARAGE TYPE: SINGLE ATTACHED ff SIGNATURE OF APPLICANT: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE TRIPLE SJ1��r�oGk s _4 8 S i� f.�G, L F. DETACHED a CARPORT a 71 Official Use Only C. Lmets:ESNO Plans Examiner Zoning Official Energy Code Compliance Information %Glazing of exterior walls Z, 2 Insulation R value of exterior walls q 3 Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) A�Al Glazing SHGC �a Glazing U-Factor 6s R value of ductwork A/C SEER rating F/2— REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release I Data filename: C:\Program Files\Check\MECcheck\1104TC.rck TITLE: 1104 TYLER COURT CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 04/04/03 DATE OF PLANS: MARCH 26, 2003 PROJECT INFORMATION: SPEC HOME COMPANY INFORMATION: ED FROEHLING BUILDER, INC COMPLIANCE: Passes Maximum UA = 612 Your Home UA = 536 12.4% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.39 Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Front Projection factor: 0.23 Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Left Side Projection factor: 0.43 Wall 3: Wood Frame, 16" o.c. Window 3: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Back Projection factor: 0.23 Door 2: Glass Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1849 30.0 0.0 65 405 13.0 0.0 26 56 0.640 36 38 445 13.0 0.0 9 409 13.0 0.0 110 18 0.400 15 36 0.640 6 23 0.640 70 0.580 10 SHGC: 0.78 Bldg. faces 180 deg. from North; Comp. orient.: Back Projection factor: 1.00 Wall 4: Wood Frame, 16" o.c. 408 13.0 0.0 31 Window 4: Metal Frame:Double Pane with Low-E 29 0.640 19 SHGC: 0.40 Bldg. faces 180 deg. from North; Comp, orient.: Right Side Projection factor: 0.27 Floor 1: Slab -On -Grade: Unheated 191 0.0 199 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 10 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release I (formerly MECchecl and to comply with the mandatory requirements listed in the REScheckInspection Checklist. Builder/Designer ✓ Date 3 Ty/er Court so' R a w. k 27, Plwmywt W- 506,E Pg. J*O `Back of Curb N44301"E-63100, in ;MI N C4 N i wt W Proposed o r I We or Formerly Residence Fdword FrwhNnt Vol. 315Z Pq, 1h I � zoi PR 5 I Ik1tIL flohfO Phow fhv 2 i 7.7• 49.5° Note: Bldg. Setback Liras 7.5' �.rJ• rper City of 00"" Station Imo• / Zoning Q rsance #ISM _..�.. J h 20' RU.E.. S 44UP'1 f " W — 6500, 0 Lot W I Lot tH Now or Formerly Now or Farrnerty Edward , Pg. 1pp Edward FroehN Val. 3162, Pg. 199 Vol. 3162, Pg. 199 I i I Soate: 10 — 20' � I Lot 7a 41 I Now or Fwmo* t Edward FroehNnqq Vol, 3162, Pg. 199 I L I Lot 85 Now or Formerly Edward FroehNnq Val. 3162, Pg. ', 69 31-79".dwg A-MIRE'EN WAFRIN , AV a fMWombwj, Lb, qQ SWIP AOSa Ca&Vo Shrho&, Tex *T1B�i •/9�'9/�.�w°'B,18 r 1 i