HomeMy WebLinkAboutRES2003-00949;,,_
�,
e�,� �'�%
PREPARED 9/08/03, 12:04:53 INSPECTION TICKET PAGE '3.
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 9/08/03
------------------------------------------------------------------------------------------------
ADDRESS . : 3717 SPRINGFIELD DR SUBDIV: WESTFIELD ADDITION PH 2A
CONTRACTOR MAIN STREET HOMES PHONE (979) 690-9964
OWNER MAIN STREET HOMES CS LTD PHONE
PARCEL 650700-1201-0090
APPL NUMBER: 03-00000949 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 5/15/03 BI BLDG, FOUNDATION -SLAB TIME: 17:00
5/15/03 CA 05/14/2003 02:44 PM SSTANLEY
B1^^ 03 5/21/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00
5/22/03 AP reinspect
05/21/2003 10:15 AM LLONG
FORM SURVEY
B100 02 5/21/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00
: 5/21/03 DP 05/20/2003 04:42 PM KELMENDORF
NO SETBACK STRINGS
NO SLAB GROUND
REMOVE TRASH AND WOOD FROM BEAM
SLEEVE COPPER
REMOVE DIRT FROM REBAR
JOSH CALLED IN AND SAID WE SHOULD HAVE A FORM SURVEY FAXED
IN FOR THIS ADDRESS
B115 01 7/14/03 DS BLDG, FRAMING TIME: 17:00
7/21/03 AP 07/14/2003 02:21 PM SSTANLEY
B125 01 9/08/03 BI BLDG, FINAL TIME: 17:00
C"Af7 09/08/2003 08:14 AM SSTANLEY
--------------------- -- COMMENTS AND NOTES ------- ---------------
j�o Lawn
MAY-21-2003 WED 03:�4 PM MAIN —STREET —HOMES 979 690 9931 P, 01
05/06/2003 16:04 7754787 CARLOMA" 9LIRVEY1W' PAGE 04
`iel no'elo ...--..ter:+..... __.,..". -. _ ,,,r., r r .
.
EsmnD PICA E I
RECORDED IN V 365 , P.246
5 44!V41 • E 56.00'
,...._10' U_E.(PU T_,1 _REST)
25' B.L,(PLAT, ORE. REST.)
---------.—. _..1
i LOT 9
LOT 8 R o BLOCK 1 �0 3e LOT 10
eb BLOCK 1 BLOCK 1FORM 1d
�rQ11 I J
`i aJ I N
Iri � r
t•
25' 8 ((PLAT, ORD. REST_)
q
I j_u. E.'( ff—T RE ) - — — - — - — - —
a W3741' w 35.00'
LEGEND
® PRAP£RTY CORNER
SPRING,�',IELD DRIVE
RLSTRICTIONS RECORDED IN VOL. 50' RV ►I
5080, PAGE 42
File namo: GLOCKI-1.0709.0WC 20 0 20 40 60 Feat
Plot date: 04/14/03 at 16:3i
Form: 05/05/03
pom K1/rV' but Slelrl
1 The Dearing aaalx of this wrny to the NORTIKAST une of
LOT No.: iJ BLOCK No: Obit) the previoua wr�wy ae rtm-4.4 M 11111 WIO� Pope 47�
AODIYION OR SUWIVI510N: AMENpNO PLAT �� Ap01110N of the onicltg Pue1lo Reaaret eT erofao Ca r"' wid storing
R*M 'lAr VOL. SM. PAOE 42 Doing 5 44'77'41" E
REOoROEO IN: VOLUME 5I1d0. 11WE 42 Eale lot Ic not undo the loo yeor Flood plain, aR Ieentlgod
by !ha Federal Emergw Monagemont Aganay on
9uRVEVEo � MA STRIET HOLIES 9=1111y PLAIN No, Z641C01 g1 O. Dated: Lly 2, 11192
STREEY A"m; 3717 SMNOPIELD DRIVE
clTr: COLLEGE $TAT10N oouN1Y: 91111 P� O° F•w f
i, oANTE CAttLOMAONa. A RECISTERtO PROFESS1ONAt. SURVEYOR, No.
1502, DO HEREBY CERTIFY THAT THE ABOVE $Um2Y IS A TRUE AND ....•.• ...
ACCURATE 99PRc9ENTATION Or AN ACTUAL ON THE OROUNO SURVEr �G
MADE uNOER MY SUPERVISION AND THERE ARE NO ENCROACHMENTS CAiD .1 •o..t...
OR OVE WS UNI,E5S OTNERWM SHOWN. NI oorwo om reorcaented by a one am i
6
DMWN RYr A. wAuncE 0/E' Ron ratio r+t �nMte oe trwlu notes, �••o$F� 5\O�Po4
rFr OM31727 TAT (®�l. 675 lurueiin� Inc. 9N • ....
VOep O 5 2714 Flnfeather Road, Bryan, Texas 7780 SuR
PHONE; (979)775-2873 FAX: (979)775-4787
BUILDING PERMIT
CITY OF COLLEGE STATIO:
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00000949 Date 4/09/03
Property Address . . . . . . 3717 SPRINGFIELD DR
Property ID . . 650700-0201-0090
R # . . . . . . . . . . . . . R114105
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . WESTFIELD ADDITION PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . UNKNOWN
Application valuation 91278
Owner Contractor
------------------------ ------------------------
MAIN STREET HOMES CS LTD MAIN STREET HOMES
MSH-CS INC RICK JENKINS PETER L DAVIS
7447 BEE CAVES RD STE 150 7447 BEE CAVE ROAD 4150
AUSTIN TX 787464130 AUSTIN TX 78746
(979) 690-9964
------ Structure Information SINGLE FAMILY HOME -----
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1383. 0
INTERIOR WALL TYPE SHEETROC"
NUMBER OF BATHROOMS 2.1.-0
NUMBER OF BEDROOMS 3.�0
SEWER TYPE PUBLIC
---------------------------------------------------------------------.-------
Permit . . . . . . BUILDING PERMIT
Additional desc . . LL/JOHN
Permit Fee . . . . 428.00 Plan Check Fee .00
Issue Date . . . . 4/09/03 Valuation . . . . 91278
Expiration Date . . 10/06/03
Qty Unit Charge Per Extension
BASE FEE 260.00
42.00 4.0000 THOU BLDG, VAL 50001-100000 168.00
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
---------------------------- ---- ---------------
BUILDING DEPT REP S A I
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATIO
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
2
Application Number . . . . . 03-00000949 Date
4/09/03
----------------------------------------------------------------------------
Special Notes and Comments
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
POST PERMIT CARD ON JOB SITE
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
Provide energy information (on back of permit application)
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL
350.00
WATER TAP 3/4" CITY INSTL
400.00
Fee summary Charged Paid Credited Due
-----------------
----------------------------------------
Permit Fee Total 428.00 428.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1178.00 1178.00 .00
.00
----- ----
BUILDING DEPT REP -
S
APPLICANT:
CITY OF COLLEGE STATION
WO-- REQUEST
PAGE
1
REQ/JOB:
WF0391100 001 PROJECT: REQUEST DATE:
4/11/PRINT 03
CREW:
PRINT TIME:
14:47:43
SCHEDULE
DATES
LOCATION:
3717 SPRINGFIELD DR
START:
4/11/03
77845 COMPLETION:
4/11/03
GEN. LOC:
COLLEGE STATION
LOC ID: 196364
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION
PRIORITY: NORMAL
REQUESTOR:
MAIN STREET (690-9964)
ORIGIN: CUSTOMER -WALK
IN
USER ID:
LLONG AUTH: LLONG
WORK TYPE: ROUTINE
4" SEWER
/ 3/4" WATER
4" SEWER / 3/4" WATER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
LICATION FOR BUILDING PER
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE�STATION.TX.US
ADDRESS/LOCATION: 37/ 7 57PQt k)Ca Fl cE� I>
LOT_ BLOCK / SUBDIVISION Westfield
Fn. afire U" avy
DATE:
APPLICATION #
TEMP POLE #
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER: Main Street Homes
CONTRACTOR ADDRESS:
ELECTRICIAN: Hillco Electric
H\/AC: Barkers HVAC
PHONE: (512) 327-8620
PLUMBER: CP Plumbi
GOOD CENTS (Residenlal only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) = NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL
DESCRIPTION OF WORK: Construct Single Family Residence
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ TOTAL AREA: HEATED AREA:
(Cost of Labor and Materials)
D PUBLIC SEWER NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
L] SEWER TAP: 4" - INTERIOR WALL TYPE: Wood / Sheetrock
X ] WATER TAP:
OTHER TAP:
.11-
3/4"
SIZE
SIZE
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
Wood/ Masonry
Post Tension on Grade
TEMP POLE ROOF TYPE: Asphalt Shingles
GARAGE TYPE: SINGLE a DOUBLE ® TRIPLE a
ATTACHED ® DETACHED a CARPORT
SIGNATURE OF APPLICANT:
Official Use Only
Comments:
YES or NO
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls R 7a
Insulation R value of exterior walls 19
Insulation R value of ceiling 1 (flat areas) 0
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC • 3CP
Glazing U-Factor .611Y
R value of ductwork q
A/C SEER rating / A
FM Office Use 0*
LICATION FOR BUILDING PER DATE:_3 a
CITY OF COLLEGE STATION APPLICATION # f�49
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840 TEMP POLE #
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US
ADDRESS/LOCATION: 3717 SPQ l °-c F1 EL.P
LOT T BLOCK 1 SUBDIVISION Westfield
�
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER: Main Street Homes PHONE: (512) 327-8620
CONTRACTOR ADDRESS: 71/117 i3 e'Ais AD �� � � � „� 7Y 7E'74/4?
ELECTRICIAN: Hillco Electric
HVAC: Barkers HVAC
PLUMBER: CP Plumbing
GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) = NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL
DESCRIPTION OF WORK: Construct Single Family Residence
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 9/ ®i 7y OL TOTAL AREA: ) $04 HEATED AREA: 1 3 3
(Cost 6f Labor and Materials)
D PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
a SEWER TAP:
X❑ WATER TAP:
OTHER TAP:
TEMP POLE
Z'n
J ILC
3/4"
SizE
NUMBER OF BEDROOMS: 3
NUMBER OF BATHROOMS: i
INTERIOR WALL TYPE: Wood / Sheetrock
EXTERIOR WALL TYPE: Wood/ Masonry
FOUNDATION TYPE: Post Tension on Grade
ROOF TYPE: Asphalt Shingles
GARAGE TYPE: SINGLE DOUBLE ® TRIPLE a
ATTACHED ® DETACHED a CARPORT a
SIGNATURE OF APPLICANT:
Official Use Only Comments:
YES or NO
Plans Examiner Zoning Official
3P- o
11-1 t' 00
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# DATE:
BUILDING ADDRESS: 5 7/ -7 y� ,
W,
I. Foundation Requirements
NANO
A. Concrete minimum f c of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' Ion
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NAIOK'
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
1. One -hour rated extending to roof deck
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing:
Floor, Wall, Ceiling and Roof Requirements continued
NA/OK
M.
Span exceeding code tables must be engineered
N.
Rafter size, spacing, grade, roof slope & bracing (if required to reduce span) indicated
on plans
�X/ 1,
O.
Roof covering
1. Roof decking indicated on plans
2. Moisture barrier indicated on plans
P.
All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R.
Overhangs not allowed on zero lot line construction
S.
Protected openings on walls < three feet from property line
III. Stairway
Requirements
OK
A.
Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B.
Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C.
Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D.
Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
NA/OK
A.
Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
PLAN REVI�..
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of
the building within ten 10 feet horizontal
V. Electrical Service Requirements
NA/OK
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
NA/OK
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/OK
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
NA/OK
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NA/OK
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Overhangs not allowed on zero lot line construction
Required parking
Street Ordinance Requirements
NA/ K
Maximum drive width for residence is 28' combined for circular
Minimum 30 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
Subdivision Regulations — Ordinance 690 N
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301 Nq/
Does not block any water course or divert any flow
Elevation certificate needed
Comments:
ZONING OFFICIAL
PLA S XAMINER
DATE
DA E