HomeMy WebLinkAboutRES2003-00934City of College Statio
1.1.0.1_--TEXAS-,, AVENUE _.
COLLEGE STATION TX 77840-
C E R T I F I C A T E O F O C C U P A N C Y
Issue Date . . .
Parcel Number . . .
Property Address
Subdivision Name
Legal Description
Property Zoning .
Owner . . . . . . .
Contractor . . . .
P E R M A N E N T
6/25/03
589700-0209-0010
1000 GARDENIA ST
COLLEGE STATION TX 77845
SUN MEADOWS PH 2
SUN MEADOWS 42, BLOCK 9, LOT 1
UNKNOWN
GRAHAM ROAD LTD
M/W CONSTRUCTION
979 694-3600
Application number 03-00000934 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL -MULTI -FAMILY
Flood Zone . . . . . . .0
Approved . . . . . . .
Building Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
PREPARED 6/20/03, 12:26:38 INSPECTION TICKET PAGE 18
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 6/20/03
------------------------------------------------------------------------------------------------
ADDRESS . : 1000 GARDENIA ST SUBDIV: SUN MEADOWS PH 2
TENANT, NBR: M/W CONSTRUCTION
CONTRACTOR M/W CONSTRUCTION PHONE (979) 694-3600
OWNER GRAHAM ROAD LTD PHONE
PARCEL 589700-0209-0010
APPL NUMBER: 03-00000934 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/21/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00
4/22/03 AP 04/21/2003 08:33 AM LLONG
B 01 5/07/03 OC BLDG, FRAMING TIME: 17:00
5/12/03 AP 05/07/2003 12:26 PM LLONG
B125 01 6 20/03 BI BLDG, FINAL TIME: 17:00
K'p 06/20/2003 11:46 AM SSTANLEY
------------------------------- -- CONTINUED ONTO NEXT PAGE -----------------------------------
\Ds
��
C_T.;' OF COLLEGE STATION
06 WORK REQUEST PAGE 1
REQ/JOB: WF0392391 / 001 PROJECT: REQUEST DATE:
4/17/PRINT 03
CREW: PRINT TIME: 14:17:04
SCHEDULE DATES
LOCATION: 1000 GARDENIA ST START: 4/17/03
77845 COMPLETION: 4/17/03
GEN. LOC: COLLEGE STATION LOC ID: 194604
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: M/W CONSTRUCTION (694-3600) ORIGIN: CUSTOMER -WALK IN
USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE
TEMP POLE PASSED
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
Linda Long - Insulation request inspecti, sult, 1000 Gardenia, 03-934 Page 1
From: Brian Henry
To: Long, Linda
Date: 5/12/03 2:09PM
Subject: Insulation request inspection result, 1000 Gardenia, 03-934
Print for File
Inspected insulation, 1000 Gardenia, #03-934, Golden Homes, 5-12-03
Inspection result: Inspected OK for Good Cents
Notes:
Poly seal and tape dining room window when installed.
Tape all sheathing joints.
CC: Stanley, Susan
CITY OF COLLEGE STATION
WORK 'QUEST
PAGE
1
REQ/JOB:
g
WF0391103 / 001 PROJECT:
REQUEST DATE:
4/11/PRINT 03
CREW:
PRINT TIME:
14:51:04
SCHEDULE
LOCATION:
1000 GARDENIA ST
START:DATES
4/11/03
77845 COMPLETION:
4/11/03
GEN. LOC:
COLLEGE STATION LOC
ID: 194604
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION
PRIORITY: NORMAL
REQUESTOR:
M/W CONSTRUCTION (694-4600)
ORIGIN: CUSTOMER -WALK
IN
USER ID:
LLONG AUTH: LLONG
WORK TYPE: ROUTINE
4" SEWER
/ 3/4" WATER
4" SEWER / 3/4" WATER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
BUILDING PERMIT
CYTY OF" COLLEGR-'STATION
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 03-00000934
Date 4/09/03
Property Address . .
. . . . 1000 GARDENIA ST
Property ID
. . 589700-0209-0010
R # . . • • • • • • •
. . . . R111777
Tenant nbr, name . .
. . . . M/W CONSTRUCTION
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . SUN MEADOWS PH 2
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 92400
Owner
Contractor
------------------------
GRAHAM ROAD LTD
------------------------
M/W CONSTRUCTION
2508 RIVER FOREST DR
MARK GOLDEN
BRYAN
TX 778022827 2912 CAIN ROAD
COLLEGE STATION
TX 77845
(979) 694-3600
--------------------------
Structure Information -------------------------
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL -MULTI -FAMILY
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1400.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
LL/MARK
Permit Fee . . . .
432.00 Plan Check Fee
.00
Issue Date . . . .
4/09/03 Valuation . .
. . 92400
Expiration Date . .
10/06/03
Qty Unit Charge Per Extension
BASE FEE 260.00
43.00 4.0000 THOU BLDG, VAL 50001-100000 172.00
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL R9SIDENTIAL
BUILDING DEPT VE:
APPLICANT: RE YENT -
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
2
Application Number . . . . . 03-00000934 Date
4/09/03
----------------------------------------------------------------------------
Special Notes and Comments
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL
350.00
WATER TAP 3/4" CITY INSTL
400.00
Fee summary Charged Paid Credited Due
----------------------------------------
-----------------
Permit Fee Total 432.00 432.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1182.00 1182.00 .00
.00
--- -- ---- --- ------ ----
BUILDING DEPT REPREdENTAIVE:
---- --
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
. . . . .
03-00000935 Date
4/09/03
Property Address
. . . . . .
1000 GARDENIA ST
Property ID
. .
589700-0209-0010
R # . . . . • • •
• • . . . .
R111777
Tenant nbr, name
. . . . . .
M/W CONSTRUCTION
Application description
. . .
TEMP POLE
Subdivision Name
. . . . . .
SUN MEADOWS PH 2
Property Use . .
. . . . . .
RESIDENTIAL
Property Zoning .
. . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation
. . . .
0
Owner
Contractor
------------------------
GRAHAM ROAD LTD
------------------------
M/W CONSTRUCTION
2508 RIVER FOREST
DR
MARK GOLDEN
BRYAN
TX 778022827
2912 CAIN ROAD
COLLEGE STATION
TX 77845
(979) 694-3600
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. LL/MARK
Permit Fee . . .
. 20.00
Issue Date . . .
. 4/09/03
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
Fee summary
Charged
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
BUILDING DEPT REP ESEN IVE: '
APPLICANT:
APPLICATION FOR BUILDING PERMI
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEG E-STATION.TX. US
Fp O e Use On
DATE: �� O
APPLICATION # /� 2 ✓ �2
TEMP POLE # D Z2
ADDRESS/LOCATION:
II
LOT BLOCK SUBDIVISION
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER: ,(�r@µ ��s,��f PHONE:
CONTRACTOR ADDRESS:
ELECTRICIAN: A PLUMBER:
HVAC: talus - - GOOD CENTS (Resid nUal only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) V NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL
DESCRIPTION OF WORK:
STRUCTURE USE: �,'L0,-_- 4, -7.L:
HOMEOWNER ASSOCIATION/ARC41TECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ "! 2 . * TOTAL AREA: l g4/ HEATED AREA:
(Cost of Labor and Materials)
Ef/PUBLIC SEWER NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 2 // /
dSEWER TAP: `1� INTERIOR WALL TYPE: S�cc /' c t✓
IZE
WATER TAP:
EXTERIOR WALL TYPE:
�b c
SIZE
OTHER TAP:
FOUNDATION TYPE:
f TEMP POLE
ROOF TYPE:
GARAGE TYPE: SINGLE a
DOUBLE TRIPLE
a
ATTACHED F2(DET
HED CARPORT
SIGNATURE OF APPLICANT:
�L gjgW3
Official Use Only
menu:
ES or NO
Plans Examiner
Zoning Official
Energy Code Compliance Information
Glazing of exterior walls
Insulation R value of exterior walls -P- / 3
Insulation R value of ceiling 1 (flat areas) (t n
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC , y o, le;5
Glazing U-Factor 6 q
R value of ductwork �-
A/C SEER rating (�� 1
7'-6
0
0
r-
30'—� 1 /2"
1000 Gardenia