Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2003-01152
... "„�Mer N' l��.�>; _cad-� ;.:�.;i4 �_p, `:s ._.�:: _ _ ��;:. y pf...Cpllege_ .Station .11 Q 1 , -TEXAS AVENUE COLLEGE STATION TX 7784. C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner . . . . . . . . . 7/17/03 585200-0205-0160 317 AGATE CT COLLEGE STATION TX 77845 STONE FOREST PH 2 STONE FOREST #2, BLOCK 5, LOT 16 UNKNOWN JOHNSON INVESTMENTS INC Contractor . . . . . . ELEGANT LIVING HOMES 979 823-0638 Application number 03-00001152 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL-SFR/DUPLEX Flood Zone . . . . . . Approved . . . . . . . Building Official VOID UNLESS SIGNED BY BUILDING OFFICIAL 0 PREPARED 7/16/03, 12:08:20 INSPECTION TICKET PAGE 11 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/16/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 317 AGATE CT SUBDIV: STONE FOREST PH 2 TENANT, NBR: SFR-STONE FOREST CONTRACTOR ELEGANT LIVING HOMES PHONE (979) 823-0638 OWNER JOHNSON INVESTMENTS INC PHONE PARCEL 585200-0205-0160 APPL NUMBER: 03-00001152 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/29/03 TB BLDG, FOUNDATION -SLAB TIME: 08:00 4/29/03 AP 04/28/2003 11:32 AM SSTANLEY SLAB GROUND BACK LEFT SIDE FORM SURVEY SUBMITTED, STRINGS WERE UP ON FRONT & LEFT SIDE B115 01 5/23/03 TB BLDG, FRAMING TIME: 17:00 5/23/03 AP 05/22/2003 03:42 PM SSTANLEY FINISH BLOCKING OSB B130 01 5/28/03 TB BLDG, INSULATION TIME: 17:00 5/28/03 AP 05/27/2003 03:01 PM SSTANLEY EARLY AS POSSIBLE, SHOULD OF BEEN TUESDAY, PLEASE B125 01 1 7/16/03 BLDG, FINAL TIME: 17:00 iO3 07/16/2003 09:04 AM SSTANLEY -------------------------------------- COMMENTS AND NOTES -------------------------------------- CITY OF COLLEGE STATION WOR: EQUEST PAGE 1 REQ/JOB: WF0394669 / 001 PROJECT: REQUEST DATE: 425/0PRINT 3 CREW: PRINT TIME: 9:44:38 SCHEDULE LOCATION: 317 AGATE CT START:DATES 4/25/03 77845 COMPLETION: 4/25/03 GEN. LOC: COLLEGE STATION LOC ID: 195102 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ELEGANT LIVING HOMES ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE TEMP POLE ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- OT-CUSTOMER SERVICE 04/28/2003 14:24 9798231606 .��. city W.UrM7bcs 01938 Dyad Rest. O.R. 961/297, o.A. 4197/55, O.R. 4629/75 ELEGA 1 LIVING HOMES MACAATWUA SURVEYS !NC. C, sox A;0 9RYj14 TE09 77805 Iota' 1»'8600 wwilc yca�-e p Ip SD 4D M MET PAGE 02 18 A 20 I� O T� he,a/0'RGQAR f M'fYfO NIY R, N 4c 07'49'8 e(7,00' 1, ntl.4,e'RIR�p • �I,A�'1'IC dA� RR.4wo. rot raid ; eonRO Plbet 6 © .•........ ... ... ..............__,,�............... Ito' �I rb171, I G UTILITY CMCWNTr WTV,, I 6R161flfl. VAMR> Aft VD, SRLN gc*$ PER ft-4T .y ---xrr---`bi '"''''j II Buie f ;I •ewe �LATAX.IYI RCeTR IaTIO,h BLOGK 5 di LOT 16 `�,,. 17 '.I � �I ---�r,:. -- � I� 15 I I- •I — CNRI iD PAGit ITIF',. I I1� !L6C ('Orl+i�) 119 ISM VWD" f•A4141T,NGLTTiIa 6 AR ''A j� � I rl * WPb7�l (8001 RR., eRfil fD M1tt,ll l.to� Z I1 14.4• II I 1w ---- -------1^___--- -I� i9•l.t..DRD. - _I.• {..� . i1 , ---.-. y( —.. I G uT f 41 TY fA48NlN7T .r.�...��..� R.1•. �Tio aFin I'M / PW t?L '16w orp" wyeDR 317 AGATE GODRT w R.p••. "t PIdT All tJtKt certain lot, twaalt or palReet of 1AM lyirtq Wd veinq aitT tad in gnaw Dounty, 'iOM$, and being riot sixteen (16), Black Viva (6), STOW 1UMM OIBI61:V CtMr DRA�CaI a, Ut ad(9itb5h to the City of College Station, seamee CountY, 7WDas, *C00%diteg kA the plat recorded in volume 4625, page 33, MiCial Re6orda of 13rp2os 05unry,-4W4km, dy I, JMPW W- M&dUIKW, Aegiffhered Yr6£RO,i0na1 UMd VUS!V yor, M. 2039, do hum* awtti,fY that this plat aometlY reprssenta a 8urM mut9e by me or W><'Wa my direeti.on, on the: ground, April 24, 2003. .....�...... . 2hta out -m preparled for the purPOAA OfMrM Survey for Elegant Living 14aotss. NO3-3285 .y .(. ■e3 mute — W virible Or appowt lAt Aiepom atria Dan unse shown hezeon. Phsed on MA 1nff Tmatiem scaled Pram the FWA map dated > Y 9, 2000, Panel No. 4804IM201 D, this property does not lie witl%in A f9eai,Rpc(Rted 100-Yawn flood area. CITY OF COLLEGE STATION WORK -QUEST PAGE 1 REQ/JOB: WF0394328 / 001 PROJEC': REQUEST DATE: 4/24/03 PRINT DATE: 4/24/03 CREW: PRINT TIME: 10:11:28 SCHEDULE LOCATION: 317 AGATE CT STTART:DATES 4/24/03 77845 COMPLETION: 4/24/03 GEN. LOC: COLLEGE STATION LOC ID: 195102 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ELEGANT LIVING HOMES-823-0638 ORIGIN: CUSTOMER -WALK IN USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE 4" SEWER AND 3/4" WATER 4" SEWER AND 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE BUI-LDING• PERMIT, .,..y, Z6 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: ---------------------------------------------------------------------------- (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00001152 Date 4/24/03 Property Address . . . . . . 317 AGATE CT Property ID . . 585200-0205-0160 R # . . . . . . . . . . . . . R112568 Tenant nbr, name . . . . . . SFR-STONE FOREST Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . STONE FOREST PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 158000 Owner Contractor ------------------------ JOHNSON INVESTMENTS ------------------------ INC ELEGANT LIVING HOMES PO BOX 800 WILLIAM C MORRIS COLEMAN TX 768340800 PO BOX 7063 BRYAN TX 77805 (979) 823-0638 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 HEATED AREA 2390.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . LL Permit Fee . . . . 634.00 Plan Check Fee .00 Issue Date . . . . 4/24/03 Valuation . . . . 158000 Expiration Date . . 10/21/03 Qty Unit Charge Per Extension BASE FEE 460.00 58.00 3.0000 THOU BLDG, VAL 100001-500000 174.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS �,, WITHIN 20 FEET 0KM CHAN.;CAL EQUIPtWNT -------- ------------ -- BUILDING DEPT REPRMENT�-TI- -----VE : 1: APPLICANT: ---t--------------- - - - - - - BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 Page 2 Application Number . . . . . 03-00001152 Date 4/24/03 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER also provide beam for the porch/patio ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 4" CITY INSTL 400.00 Fee -summary Charged P -_d --\----ite- -----Due-- BUILDING DEPT REPRAS TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: ---------------------------------------------------------------------------- (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00001153 Date 4/24/03 Property Address . . . . . . 317 AGATE CT Property ID . . . . . . . . . 585200-0205-0160 Application description . . . TEMP POLE Subdivision Name . . . . . . STONE FOREST PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ JOHNSON INVESTMENTS INC ELEGANT LIVING HOMES PO BOX 800 WILLIAM C MORRIS COLEMAN TX 768340800 PO BOX 7063 BRYAN TX 77805 (979) 823-0638 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . LL Permit Fee . . . . 20.00 Issue Date . . . . 4/24/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary ----------------- Charged Paid Credited ---------------------------------------- Due Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------- BUILDING DE APPLICANT: LL APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEG E-STATION.TX. US ADDRESS/1-050rTION: LOT / 6 BLOCK -/J / SUBDIVISION For Ofte Uw 0. , jj�� ( DATE: (/ `! 1 J - 03 APPLICATION # _ ®3 if , 5b TEMP POLE # D 3 _ 1 163 BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: 1p(IQ Q �j Ajfr o-:r j 5 PHONE: � 7C` - ,22 1 -.2Z" _7 CONTRACTOR ADDRESS: PC' 13e 74v"� 3 Arl^ Ctyi a T'X ) 7FC'g ELECTRICIAN: �'� L%t c !^I t; PLUMBER: _ Al -A P/cAi6."1 1 HVAC: Al oec re '5 A(' GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) W CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL DESCRIPTION OF WORK: STRUCTURE USE: .,S r_ ,, HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: �L�5 TEXAS ACCESSIBILITY STANDARD (fA$YPROJECT REGISTRATION# EABPRJ VALUATION: $ i {j , coo, TOTAL AREA: Z HEATED AREA:.;V-3 7C> (Cost of 1.1bor and Materials) �UBLIC SEWER SEPTIC/TREATMENT SYSTEM SEWER TAP: 4 " SI E WATER TAP: 3f r SIZE OTHER TAP: SIZE 21EMP POLE GARAGE TYPE: SINGLE a ATTACHED h/)/ E2 SIGNATURE OF APPLICANT: NUMBER OF BEDROOMS: 4- NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE:d^i c /C FOUNDATION TYPE: ('E'oofy'k41 !F "k'2'e ROOF TYPE: DOUBLE EZ TRIPLE DETACHED EJ CARPORT ED Official Use Only k3 - ents: y YE r NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls S� Insulation R value of exterior walls 13 Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) 19 Glazing SHGC (::�, Glazing U-Factor , 6C2 R value of ductwork _6 A/C SEER rating /.)- f MECcheck Compliance Report 2000 IECC MECcheck Software Version 3.2 Release lb TITLE: Harvey Residence CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 04/ 14/03 DATE OF PLANS: March 2003 PROJECT INFORMATION: Lot 16, Block 5, Stone Forest, Phase 2 COMPANY INFORMATION: ELH-Elegant Living Homes, Inc. P. O. Box 7063 Bryan, Texas 77805 NOTES: Please call when the permit is ready to be picked up Bill Morris - Cell 229-2045 Cindy Morris- Cell 777-0703 Thanks! COMPLIANCE: Passes Maximum UA = 625 Your Home = 428 31.5% Better Than Code Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Raised or Energy Truss Exterior Wall 1: Wood Frame, 16" o.c. Window: 3060: Other Window: 6020: Other Window: 2076: Other Window: 6016: Other Window: 3050: Other Window: 3080: Other Window: 2860: Other Window: 4040: Other Window: 2816: Other Door: 3/0: Solid Door: 2/8: Solid Air Conditioner 1: Electric Central Air, 12 SEER Gross Area or Perimeter 2329 61 2402 72 12 30 9 30 72 48 16 4 20 53 Permit Number Checked By/Date Glazing Cavity Cont. or Door R-Value R-Value U-Factor UA 0.0 30.0 0.0 30.0 13.0 0.0 72 2 167 0.600 43 0.600 7 0.600 18 0.600 5 0.600 18 0.600 43 0.600 29 0.600 10 0.600 2 0.170 3 0.170 9 Im COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 I CC require e is in MECcheck Version 3.2 Release lb. r ZJ ,y% �/� Builder/Designer G Gam-- �' G'�.--___ Date :61r � MECcheck Inspection Checklist 2000 IECC MECcheck Software Version 3.2 Release lb DATE: 04/14/03 TITLE: Harvey Residence Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation Comments: [ ] 2. Ceiling 2: Raised or Energy Truss, R-30.0 continuous insulation Comments: Insulation must achieve full height over the plate lines of exterior walls. Above -Grade Walls: [ ] 1. Exterior Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: [ ] ( 1. Window: 3060: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Y x 6' Window [ ] 2. Window: 6020: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 6' x 2' Eyebrow [ ] 3. Window: 2076: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 2' x 7.5' Window [ ] 4. Window: 6016: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 6' x 1'6" Transom Window [ ] 5. Window: 3050: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Y x 5' Window [ ] 6. Window: 3080: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Y x 8' Window [ ] 7. Window: 2860: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 2'8" x 6' Window [ ] 8. Window: 4040: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 4'x 4' OBSC SG [ ] 9. Window: 2816: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 2' 8" x 1' 6" Transom Doors: [ ] 1. Door: 3/0: Solid, U-factor: 0.170 Comments: 3' x 6' 8" Fiberglass Door [ ] 2. Door: 2/8: Solid, U-factor: 0.170 Comments: 2'8" x 68" Door Heating and Cooling Equipment: 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation. Materials Identification: Materials and equipment must be installed in accordint to the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values, glazing U-values, and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the I levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)