Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2003-01151
PREPARED 8/18/03, 12:32:17 INSPECTION TICKET PAGE 6 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/18/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 1306 ROANOKE CT SUBDIV: SHENANDOAH PH 7 CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER FROEHLING, EDWARD PHONE PARCEL 569500-0727-0620 APPL NUMBER: 03-00001151 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 5/27/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00 5/27/03 AP 05/27/2003 10:32 AM KELMENDORF strings pulled slab ground back left Bl _=01 7/14/03 CH BLDG, FRAMING TIME: 17:00 t 7/15/03 AP 07/11/2003 02:36 PM KELMENDORF afternoon B130'01 7/17/03 CH BLDG, INSULATION TIME: 17:00 7/17/03 AP 07/16/2003 02:16 PM LLONG B125:01 8/15/03 CH BLDG, FINAL TIME: 17:00 8/15/03 DP 08/15/2003 07:57 AM SSTANLEY 3 needs kitchen sink cleanout cap } soffitt vent covers needed 'a need front door glass installed no lawn irrigation system B125 02 8/18 03 BI BLDG, FINAL TIME: 17:00 v 08/18/2003 08:53 AM KELMENDORF -------------------------------- COMMENTS AND NOTES -------------------------------------- o Lawn I Y!1rA6 n �4e_rlx CITE' OF COLLEGE STATION WORK REQUEST PAGE 1 REQ/JOB: WF0415934 / 001 PROJECT: REQUEST DATE: 6/09/PRINT 03 CREW: PRINT TIME: 11:58:42 SCHEDULE LOCATION: 1306 ROANOKE CT START:DATES 6/09/03 77845 COMPLETION: 6/09/03 GEN. LOC: COLLEGE STATION LOC ID: 195178 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ED FROEHLING BLDRS (776-8266) ORIGIN: CUSTOMER -WALK IN USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE TEMP POLE ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE BUILDING PERMIT per* C I-OMffi COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00001151 Date 4/23/03 Property Address . . . . . . 1306 ROANOKE CT Property ID . . 569500-0727-0620 R # . . . . . . . . . . . . . R112786 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SHENANDOAH PH 7 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 105864 Owner Contractor ------------------------ FROEHLING, EDWARD ------------------------ ED FROEHLING BUILDERS 3887 HIGH LONESOME ED FROEHLING COLLEGE STATION TX 778459443 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL -MULTI -FAMILY Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1604.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 478.00 Plan Check Fee .00 Issue Date . . . . 4/23/03 Valuation . . . . 105864 Expiration Date . . 10/20/03 Qty Unit Charge Per Extension BASE FEE 460.00 6.00 3.0000 THOU BLDG, VAL 100001-500000 18.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT ------------------------------ BUILDING DEPT REPRESENTATIVE: ---- -------------------- w �� BUILDING PERMIT CITY OF COLLEGE STATI 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00001151 Date 4/23/03 ---------------------------------------------------------------------------- Special Notes and Comments ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited Due ----------------------------------------------- ---------- Permit Fee Total 478.00 478.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1228.00 1228.00 .00 .00 ----------------------------------------- --------------------- BUILDING DEPT REPRESENTATIVE: �- APPLICANT: CITY OF COLLEGE STATION WO] ZEQUEST PAGE 1 REQ/JOB: WF0394078 / 001 PROJECT: REQUEST DATE: 4/23/PRINT 03 CREW: PRINT TIME: 16:23:45 SCHEDULE LOCATION: 1306 ROANOKE CT STTART:DATES 4/23/03 77845 COMPLETION: 4/23/03 GEN. LOC: COLLEGE STATION LOC ID: 195178 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 3/4" WATER 4" SEWER 3/4" WATER 4" SEWER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE Fa Ofte Use 0* APPLICATION FOR BUILDING PERMIT DATE: //ll%%�,0_ CITY OF COLLEGE STATION APPLI ION # F; Z J� 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 TEMP OLE # (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION: (SQ6 4r3a!2_-T � LOT `� BLOCK 2 7 SUBDIVISION -7 " 8 BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: f=D F�oEIfGlt12G; fjc,lLpga.IA>C PHONE: 776.9066 CONTRACTOR ADDRESS: _ 38f? 7 _. &T) ELECTRICIAN: (�,I-B J✓-�C.7-�!c PLUMBER: ! i- HVAC: :I' G ).1>A_;& V.+rj VE S E.rZ V[c.,f5 GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL DESCRIPTION OF WORK: STRUCTURE USE: S /A)Q F F 4n/ 1-y 2t51 pE,vG 4t HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: /9 TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ /- 0 5- A4 g - ✓ TOTAL AREA: 2(7� HEATED AREA: (Cost of Lab6r and Materials) F PUBLIC SEWER ❑ SEPTIC/TREATMENT SYSTEM u SEWER TAP: SIZE 11 WATER TAP: SIZE NUMBER OF BEDROOMS: ✓ NUMBER OF BATHROOMS: `� INTERIOR WALL TYPE: S 4je f, -r r ©G k EXTERIOR WALL TYPE: B p 1 GG I< ❑ OTHER TAP: FOUNDATION TYPE: 61-4 13 SIZE TEMP POLE ROOF TYPE: F_ GARAGE TYPE: SINGLE a DOUBLE TRIPLE ATTACHED ff DETACHED a CARPORT ED SIGNATURE OF APPLICANT: C Official Use Only Paqments: 143 YES r NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls .� Insulation R value of ceiling 1 (flat areas) �� Insulation R value of ceiling 2 (vaulted areas/no attic) NIA - Glazing SHGC Glazing U-Factor . 6S R value of ductwork A/C SEER rating 1t).,�35�/2- REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: Untitled.rck TITLE: 1306 Roanoke Court CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 04/15/03 DATE OF PLANS: February 21, 2003 PROJECT INFORMATION: Bond Home COMPANY INFORMATION: Ed Froehling Builder COMPLIANCE: Passes Maximum UA = 354 Your Home UA = 315 11.0% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.35 Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 315 deg. from North; Comp. orient.: Front Projection factor: 0.15 Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 315 deg. from North; Comp. orient.: Left Side Projection factor: 1.00 Door 2: Glass SHGC: 0.78 Bldg. faces 315 deg. from North; Comp. orient.: Left Side Projection factor: 1.38 Wall 3: Wood Frame, 16" o.c. Window 3: Metal Frame:Double Pane with Low-E Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1604 30.0 0.0 56 396 13.0 0.0 25 56 0.640 36 38 0.400 15 312 13.0 0.0 24 2 0.640 1 18 0.580 10 396 13.0 0.0 142 21 0.640 91 SHGC: 0.40 Bldg. faces 315 deg. from North; Comp. orient.: Back Projection factor: 0.23 Wall 4: Wood Frame, 16" o.c. 312 13.0 0.0 24 Window 4: Metal Frame:Double Pane with Low-E 18 0.640 12 SHGC: 0.40 Bldg. faces 315 deg. from North; Comp. orient.: Right Side Projection factor: 0.43 Air Conditioner 1: Electric Central Air, 10 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release lb (formerly MECchecl and to comply with the mandatory requirements listed in the RES checklnspection Checklist. Builder/Designer z Date A -5 Jul it 02 09:59a Michael McClure 979 693W2554 P•3 90A u©g�F Court A--42'34'04" 50' R.0-W. — 27' Pa►ement R-44 87' Vol.. 4671, Pg. 157 L�33.3C.33' r-1748' Hock of Curb ~� 20 S 4576:36_ W - 54-65' 5 PIVE. N r �a c�r• c; I ``---- Proposed I Residence Now m or Forsry mr Eawd Fnxkiling Vol. zass. Pg. sor ,, J iAol► Y�Z, 3Rifi✓ 17*7 /} v ! Now or Formwiv j Sho�tandW6 Pftm 7 ,P Edward Froohling ` Vol. 26$8. Pg. 2U, 7.5' h r 1— Bldg. Setback Unes per City or W199e Station Zoning Ordinance f t83H w T in 20' P.U.E. 4526tx" W - 9 V U7--<sr27.d+g ,WCl UREENG/NEFMING, INC • f008 Salte >O3 o Co/1-we Sr *b-,7, Texas 7T�i�5 f�T j C� �3-s 3N PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# DATE: BUILDING ADDRESS: 1361e RO=Ag- C ou(� I. Foundation Requirements NA/OK A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' Ion 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated IA II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/OK A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate p D. Tenant separation in duplex A 1. One -hour rated extending to roof deck E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX II. Framing: Floor, Wall, Ceiling and Roof Requirements continued NA/OK M. Span exceeding code tables must be engineered N. Rafter size, spacing, grade, roof slope & bracing (if required to reduce span) indicated on plans O. Roof covering 1. Roof decking indicated on plans 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs not allowed on zero lot line construction S. Protected openings on walls < three feet from property line III. Stairway Requirements K A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. 1 reads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements (to be indicated on plans) NA/OK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward p 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX C. Chimneys must extend at least three (3) feet higher than the highest point where it projects through the roof of a building & at least two (2) feet higher than any portion of the buildingwithin ten 10 feet horizontal b V. Electrical Service Requirements NA/OK A. Electrical plan to include: 0 2 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements NA/OK A. Pressure reducing valve required when water pressure exceeds 80 psi B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/OK A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Ener y Requirements N OK A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/OK Permitted use for district Density requirements t4 Minimum lot size p Setbacks Easements Overhangs not allowed on zero lot line construction 20' triangle clear at corner Required parking Street Ordinance Requirements NA/OK Maximum drive width for residence is 28' Minimum 30 feet from driveway to side(intersecting) street -- PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX Subdivision Regulations — Ordinance 690 NA/OK Approved subdivision Plat filed nip Flood lain Regulations — Ordinance 1301 OK Does not block any water course Need elevation certificate ZONING OFFICIAL �1 PLANS EXAMINER DATE as ATE