Loading...
HomeMy WebLinkAboutRES2003-01142PREPARED 10/28/03, 12:10:59 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/28/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 4406 EDINBURGH PL SUBDIV: CASTLEGATE SEC 1 PH 2 CONTRACTOR DUSTY PHILLIPS CONSTRUCTION PHONE (979) 229-4850 OWNER GREENS PRAIRIE INVESTORS LTD PHONE PARCEL 184200-2101-0330 APPL NUMBER: 03-00001142 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 5/16/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00 5/18/03 AP 05/16/2003 08:59 AM KELMENDORF Last of the day please SETBACKS PER STRINGS SLAB GROUND AT LEFT BACK CORNER B115 01 6/30/03 TB BLDG, FRAMING TIME: 17:00 7/02/03 AP 06/30/2003 09:53 AM KELMENDORF WINDOW TO RIGHTOF REAR DOOR S/B TEMPERED BY FINAL B130 01 7/07/03 OC BLDG, INSULATION TIME: 17:00 7/08/03 AP 07/07/2003 12:30 PM LLONG B125 01 02�0/28/03 BI BLDG, FINAL TIME: 17:00 © bra 10/28/2003 10:25 AM MALFORD -----------V---------------�------ COMMENTS AND NOTES e AwA. ` em J � PREPARED 10/29/03, 13:26:23 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/31/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 4406 EDINBURGH PL SUBDIV: CASTLEGATE SEC 1 PH 2 CONTRACTOR DUSTY PHILLIPS CONSTRUCTION PHONE (979) 229-4850 OWNER GREENS PRAIRIE INVESTORS LTD PHONE PARCEL 184200-2101-0330 APPL NUMBER: 03-00001142 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: MECH 00 MECHANICAL PERMIT SUB: CLIMATE MASTERS (979)775-6572 REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ M100 01 6/30/03 TB MECH, ROUGH IN TIME: 17:00 7/02/03 AP 06/30/2003 09:58 AM KELMENDORF Mli^ 01 10/31/03 BI MECH, FINAL TIME: 17:00 ,2-11 �v�_ 10/28/2003 10:29 AM SSTANLEY 03 -----------------------------IT------ COMMENTS AND NOTES-------------------------------------- CITY OF COLLEGE STATION WORK (QUEST PAGE 1 REQ/JOB: WF0420691 / 001 PROJECT: REQUEST DATE 6,/24PRINT /03 CREW: PRINT TIME: 11:52:32 SCHEDULE LOCATION: 4406 EDINBURGH PL START:DATES 6/24/03 77845 COMPLETION: 6/24/03 GEN. LOC: COLLEGE STATION LOC ID: 193282 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: DUSTY PHILLIPS CONSTRUCTION ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE TEMP POLE ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE CITY OF COLLEGE STATION WOR: `'EQUEST PAGE 1 REQ/JOB: WF0398081 /.U01 PROJECT:, REQUEST DATE: 5/02/PRINT 03 CREW: PRINT TIME: 14:46:01 LOCATION: 4406 EDINBURGH PL SCHEDULE STTART:DATES 5/02/03 77845 COMPLETION: 5/02/03 GEN. LOC: COLLEGE STATION LOC ID: 193282 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: DUSTY PHILLIPS ORIGIN: CUSTOMER -WALK IN USER ID: KELMENDORF AUTH: KELMENDORF WORK TYPE: ROUTINE 3/4" WATER 4" SEWER ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 3/4" WATER 4" SEWER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE BUILDING PERMIT CITY �O COLLEG TAATIO: 110��.� COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00001142 Date 5/02/03 Property Address . . . . . . 4406 EDINBURGH PL Property ID . . 184200-2101-0330 R # . . . . . . . . . . . . . R111159 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE SEC 1 PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 192786 Owner Contractor ------------------------ ------------------------ GREENS PRAIRIE INVESTORS LTD DUSTY PHILLIPS CONSTRUCTION 4490 CASTLEGATE DR DUSTY PHILLIPS COLLEGE STATION TX 778453388 4490 CASTLEGATE DRIVE COLLEGE STATION TX 77845 (979) 229-4850 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2239.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KE Permit Fee . . . . 739.00 Plan Check Fee .00 Issue Date . . . . 5/02/03 Valuation . . . . 192786 Expiration Date . . 10/29/03 Qty Unit Charge Per Extension BASE FEE 460.00 93.00 3.0000 THOU BLDG, VAL 100001-500000 279.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT ---------------------------------------- ---- -- --- ------------------------ BUILDING DEPT REPRESEENT/ATTIVE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATIO 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00001142 Date 5/02/03 ---------------------------------------------------------------------------- Special Notes and Comments ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES max. spacing for foundation beams is 15' ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 739.00 739.00 .00 .00 ----------------------------------------- ------ --- ----------------------- BUILDING DEPT REPRESENTATIVE ) APPLICANT: (c --7 � 0- BUILDING PERMIT CITY OF COLLEGE STATIO: 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 03-00001142 Date 5/02/03 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1489.00 1489.00 .00 .00 - TEMPORARY POLE PERMIT CITY OF COLLEGE STATIOT 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . Property Address . . . . Property ID Application description Subdivision Name . . . . Property Use . . . . . . Property Zoning . . . . . Application valuation . . 03-00001143 4406 EDINBURGH PL 184200-2101-0330 TEMP POLE CASTLEGATE SEC 1 PH 2 RESIDENTIAL PLANNED DEVL HOUSING 0 Date 5/02/03 Owner Contractor ------------------------ GREENS PRAIRIE INVESTORS LTD ------------------------ DUSTY PHILLIPS CONSTRUCTION 4490 CASTLEGATE DR DUSTY PHILLIPS COLLEGE STATION TX 778453388 4490 CASTLEGATE DRIVE COLLEGE STATION TX 77845 (979) 229-4850 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KE Permit Fee . . . . 20.00 Issue Date . . . . ---------------------------------------------------------------------------- 5/02/03 Valuation . . . . 0 Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary ----------------- Charged Paid Credited Due Permit Fee Total ---------- 20.00 -------------------- 20.00 .00 ---------- .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 - A ]CATION FOR BUILDING PERM CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEG E-STATION.TX.US rwoff�use 0 DATE: 4-1 0 3 APPLICAnoN �— I I LA a--� TEMP POLE # V I 1 ADDRESS/LOCATION: `i 9019 Fd i n bLiO,, / /� LOT ;S BLOCK SUBDIVISION �.G.54-4a4e Comm,.(hjjres BUSINESS/OWNER NAME: l6-kf Rd li 4 I. y6ll LtalIovi l hL . PHONE:(`'t 7q-] 26g2-gF50 CONTRACTOR/HOMEOWNER: SGvne PHONE: CONTRACTOR ADDRESS: q'IgO Css&2e�4 pr- Ca(le5,e 5 Am,� TX, 7?gg5- ELECTRICIAN: 6 W HVAC: Ll;wde 0746�e .5 PLUMBER: kwu-" Pi�mb:n GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) f NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: STRUCTURE USE: v.P,.o ti, HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ to, ), j s (0 TOTAL AREA: °la A t . HEATED AREA: a a 3q (Cost of Labor dnd Materials) ❑ PUBLIC SEWER ❑ SEPTIC/TREATMENT SYSTEM ❑ SEWER TAP: q ❑ WATER TAP: ❑ OTHER TAP: TEMP POLE GARAGE TYPE: SIZE 'I I SIZE SIZE SINGLE ❑ ATTACHED ❑ SIGNATURE OF APPLICANT: NUMBER OF BEDROOMS: NUMBER OF BATHROOMS INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: concrtk ROOF TYPE: 6l I V1110 DOUBLE ❑✓ TRIPLE ❑ DETACHED ❑ CARPORT ❑ Ot#clal Use Only menu: YE or NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls ; l l .'5 Insulation R value of exterior walls i 3 Insulation R value of ceiling 1 (flat areas) 1,5 Insulation R value of ceiling 2 (vaulted areas/no attic) 3y Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating ,'i ,sa PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# DATE: O '�7 1 o BUILDING ADDRESS: ggb(o Ec�►nb �io� I. Foundation Requirements NA/OK A. Concrete minimum f'c of 3000 PSI oK B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' long) 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 0 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement Ij F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/OK A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans ON C. Treated sill plate or bottom plate D. Tenant separation in duplex A 1. One -hour rated extending to roof deck E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX II. Framing: Floor, Wall, Ceiling and Roof Requirements continued NA/OK M. Span exceeding code tables must be engineered N. Rafter size, spacing, grade, roof slope & bracing (if required to reduce span) indicated on plans O. Roof covering 1. Roof decking indicated on plans 4- 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs not allowed on zero lot line construction S. Protected openings on walls < three feet from property line III. Stairway Requirements EJOK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements (to be indicated on plans) N OK A. Hearth extensions . - 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials - PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX C. Chimneys must extend at least three (3) feet higher than the highest point where it projects through the roof of a building & at least two (2) feet higher than any portion of the building within ten 10 feet horizontal K V. Electrical Service Requirements NA/ K A. Electrical plan to include: a 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements NA/OK A. Pressure reducing valve required when water pressure exceeds 80 psi o 2 B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/OK A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements NA/OK A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/OK Permitted use for district Density requirements Minimum lot size Setbacks Easements nK Overhangs not allowed on zero lot line construction 20' triangle clear at corner Required parking Street Ordinance Requirements NA/OK Maximum drive width for residence is 28' Minimum 30 feet from driveway to side(intersecting) street — PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX Subdivision Regulations — Ordinance 690 I NA/OK Approved subdivision Plat filed Flood lain Regulations — Ordinance 1301 OK Does not block anv water course 1\ Need elevation certificate ZONING OFFICIAL PLANS EXAMINER S moKe_ bAe c cot 5 DATE ATE ` w Raels 4: �� 0- - GROSS NALL SO. FT.: 2,023.5113 PERCENTAGE OF FENESTRATION FENESTRATION SO. FT.: 431.60 TO NALL RATIO: 21.3% IN ACCORDANCE NITH CHAPTER 5 OF THE INTERNATIONAL ENERGY CONSERVATION CODE, AND BASED ON THE PRESCRIPTIVE BUILDING ENVELOPE REQUIREMENTS FOR T14E BRYAN/COLLEGE STATION AREA, THE FOLLONING SPECIFICATIONS WILL APPLY: TABLE S02.2.4(G), MAX 25% RATIO MAXIMUM GLAZING U FACTOR: 0.52 MINIMUM EXTERIOR NALL R-VALUE: R-13 MINIMUM CEILING R-VALUE: R-30 MINIMUM HVAC SEER VALUE: 10 SEER ENERGY CODE SPECS CALCULATED FOR: DUSTY PHILLIPS CONSTRUCTION DATED: 04/ 14/03 14 Apr 15 2003 9:52AM ens Prairie Investors 97-690-1041 p.3 0 000t • C 1 32 G�0 I OW 1 N