HomeMy WebLinkAboutRES2003-01124a
PREPARED 7/14/03, 12:32:50 INSPECTION TICKET PAGE 19
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/14/03
------------------------------------------------------------------------------------------------
ADDRESS . : 3812 OLDENBURG LN SUBDIV: EDELWEISS GARTENS PH 4
TENANT, NBR: 3814 OLDENBURG ALSO
CONTRACTOR K M CUSTOM HOMES PHONE (979) 589-3739
OWNER EDELWEISS GARTEN VENTURE PHONE
PARCEL 244030-0409-0270
APPL NUMBER: 03-00001124 RESIDENTIAL, 2 UNITS NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 5/27/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00
5/28/03 AP 05/27/2003 09:37 AM SSTANLEY
SETBACK STRINGS PULLED
B 01 7/01/03 DS BLDG, FRAMING TIME: 17:00
s 7/01/03 AP 07/01/2003 08:25 AM KELMENDORF
already done by David Stone. Done in the AM. He needs to
sign.
B125 01 7/14/03 B/j� BLDG, FINAL TIME: 17:00
AA
(, 07/14/2003 09:16 AM SSTANLEY
----'---------------------------- 171---- COMMENTS AND NOTES --------------------
Ile
i
CITY OF COLLEGE STATION
WORK DUEST is
PAGE
1
.�:
REQ/JOB:
WF0392538 / 001 PROJECT:
REQUEST DATE:
4/18/03
PRINT DATE:
4/18/03
CREW:
PRINT TIME:
12:02:50
SCHEDULE
LOCATION:
3812 OLDENBURG LN
START:DATES
4/18/03
77845 COMPLETION:
4/18/03
GEN. LOC:
COLLEGE STATION LOC
ID: 197216
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION
PRIORITY: NORMAL
REQUESTOR:
K M CUSTOM HOMES (589-3739)
ORIGIN: CUSTOMER -WALK
IN
USER ID:
LLONG AUTH: LLONG
WORK TYPE: ROUTINE
(1) 4"
SEWER & (2) 3/4" WATER
REQUEST COMMENTS
DUPLEX - 3812/3814 OLDENBURG LANE
(1) 4" SEWER & (2) 3/4" WATER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
-----------------------------------------------------------------------------
Application Number . . . . . 03-00001124 Date 4/17/03
Property Address . . . . . . 3812 OLDENBURG LN
Property ID . . 244030-0409-0270
R# . . . . . . . . . . . . . R*****
Tenant nbr, name . . . . . . 3814 OLDENBURG ALSO
Application description . . . RESIDENTIAL, 2 UNITS NEW
Subdivision Name . . . . . . EDELWEISS GARTENS PH 4
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . DUPLEX RESIDENTIAL
Application valuation . . . . 181500
Owner Contractor
EDELWEISS GARTEN VENTURE K M CUSTOM HOMES
311 CECILIA LOOP KENNY MELESKY
COLLEGE STATION TX 778456310 8778 OLD RELIANCE RD
BRYAN TX 77808
(979) 589-3739
------ Structure Information DUPLEX
-----
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
HEATED AREA
2750.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
6.00
NUMBER OF BEDROOMS
6.00
SEWER TYPE
PUBLIC
----------------------------------------------------------------------------
Permit
BUILDING PERMIT
Additional desc
LL/KENNY
Permit Fee . . . .
706.00 Plan Check Fee
.00
Issue Date . . . .
4/17/03 Valuation . .
. . 181500
Expiration Date . .
10/14/03
Qty Unit Charge
Per
Extension
BASE FEE
460.00
82.00 3.0000
THOU BLDG, VAL 100001-500000
246.00
----------------------------------------------------------------------------
Special Notes and Comments
ADD SMOKE DETECTOR(S)
PER NOTES ON PLANS
ALL BRANCH CIRCUITS THAT
SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS
WITHIN 20 FEET OF MECHANICAL EQUIPMENT
----------------------
BUILDING DEPT RE ESEJTATIVE:�
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
-----------------------------------------------------------------------------
Page
2
Application Number 03-00001124 Date
4/17/03
----------------------------------------------------------------------------
Special Notes and Comments
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
Provide detail of rated separation wall.
6 x 6 WWM @ 4' o c not allowed for stirrups in beams.
-----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL
350.00
WATER TAP 3/4" CITY INSTL
800.00
Fee summary Charged Paid Credited Due
---------------------------
------------------------------
Permit Fee Total 706.00 706.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 1150.00 1150.00 .00
.00
Grand Total 1856.00 1856.00 .00
.00
BUILDING DEPT
APPLICANT
ES T
n Q��,
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
1NWW.CI.COLLEGE-STATION. I A.US
DATE: 4- I I ` if
APPLICATION # 03
TEMP POLE #
ADDRESS/LOCATION:
D t/�e►
�.:�r L c?t1C
LOT �_ BLOCK
SUBDIV ION
(. e IV � 5
J�-a,V Zh 5
BUSINESS/OWNER NAME:
CaS N ',ue5
Tot-
PHONE:.l 0 �-7_1 -75
CONTRACTOR/HOMEOWNER:
CONTRACTOR ADDRESS: /0
ELECTRICIAN:
4)
PHONE:
PLUMBER: I.N(a k
HVAC: �:+^� �'� GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX =6ndscapePlans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTIOK
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ _.5=4"- ' M!� TOTAL AREA: Jq3V HEATED AREA 7)51)
(Cost of Labor and Materials)
PUBLIC SEWER 1 v Icy'OO NUMBER OF BEDROOMS: 3
Lj SEPTICJTREATMENT SYSTEM NUMBER OF BATHROOMS:
�I
SEWER TAP: INTERIOR WALL TYPE:
S
WATER TAP: EXTERIOR WALL TYPE:
SIZE
OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE: SINGLE a
ATTACHED
SIGNATURE OF APPLICANT:
FOUNDATION TYPE:
ROOF TYPE: d`'q
DOUBLE a TRIPLE a
DETACHED CARPORT a
nal e Only
me
YE NO
fly
Plans Examiner oning Official
Energy Code Compliance Information
% Glazing of exterior walls a �-
Insulation R value of exterior walls R 13
Insulation R value of ceiling 1 (flat areas) 30
Insulation R value of ceiling 2 (vaulted areas/no attic) itj_
Glazing SHGC
Glazing U-Factor . �A
R value of ductwork C
A/C SEER rating Z
7
c
c
c
r
70-00'
I
!
I
I
I
I
a
i
I
U' REAR SETBACK
i
--------------------
----------
I
------
Uw�I
m i
N
w I:i
00
10
7'�
10 1
I�
I;
P
�I
I
I
'I
i
5' WID
S I
I
!
18'-6'
24'-0'
I
18'-6" !
25' B.S.L.
i
i
o
j
CONC
j
j
O1
DRIVE
j
aI
aaoa
1
rLAND
V�'J
DSCAPE
SCAP
OLDENBURG LANE
egg
SITE PLAN
SCALE: 1770,70
EDELWIESS GARTENS
22 L Z3 L
�--
' • ' m 1111�
8'-11" ( 7'-3" I 7'-11.'
27'-1 1/2"
a
54'-3"
FLOOR PLAN
ENERGY CODE ITEMWINDOW
IN I N -R VALUE-
TOTAL EXT WALL AREA =1 1
TOTAL
EXT. OPENINGS= 152 S.F.
PERCENT GE OF WALL OPENINGS=
8%
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# D j� DATE: zz
BUILDING ADDRESS:
n
I. Foundation Requirements
NA/dKj
A. Concrete minimum fc of 3000 PSI
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
I
ivy
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' Ion
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
w
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
1. One -hour rated extending to roof deck
E. Header sizes indicated on plans
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
NA/OK
M. Span exceeding code tables must be engineered
N. Rafter size, spacing, grade, roof slope & bracing (if required to reduce span) indicated
on plans
O. Roof covering
1. Roof decking indicated on plans
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs not allowed on zero lot line construction
S. Protected openings on walls < three feet from property line
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
Vt
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
K
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of
the building within ten 10 feet horizontal
V. Electrical Service Requirements
NA/OK
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
NA/OK
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/OK
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
PIZ
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
tl
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NA/
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Overhangs not allowed on zero lot line construction
Required parking
Street Ordinance Requirements
NA/O
Maximum drive width for residence is 28' combined for circular
Minimum 30 feet from driveway to side(intersecting) street
Driveway access to lesser street for corner lots
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
Subdivision Regulations — Ordinance 690 NA/OKJ
Approved subdivision
Plat filed 1 L
Flood lain Regulations — Ordinance 1301 N 6K
Does not block any water course or divert any flow
Elevation certificate needed 1
Comments:
ZONING OFFICIAL
DATE
l,� . C93
PLANS EXAMINER EDA E
PORCH
7'-3" _ 1 7'-1 1 ° 19„ 19..
27'-1 1/2"
FLOOR PLAN
ENERGY CODE ITEMS
L I I N R VALUE=
TOTAL EXT. WALL AREA =181-6 S.F.
TOTAL EXT. OPEN!NCS= 152 S.F.
PERCENTAGE OF WALL OPENINGS= 8%