Loading...
HomeMy WebLinkAboutRES2003-01124a PREPARED 7/14/03, 12:32:50 INSPECTION TICKET PAGE 19 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/14/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 3812 OLDENBURG LN SUBDIV: EDELWEISS GARTENS PH 4 TENANT, NBR: 3814 OLDENBURG ALSO CONTRACTOR K M CUSTOM HOMES PHONE (979) 589-3739 OWNER EDELWEISS GARTEN VENTURE PHONE PARCEL 244030-0409-0270 APPL NUMBER: 03-00001124 RESIDENTIAL, 2 UNITS NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 5/27/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00 5/28/03 AP 05/27/2003 09:37 AM SSTANLEY SETBACK STRINGS PULLED B 01 7/01/03 DS BLDG, FRAMING TIME: 17:00 s 7/01/03 AP 07/01/2003 08:25 AM KELMENDORF already done by David Stone. Done in the AM. He needs to sign. B125 01 7/14/03 B/j� BLDG, FINAL TIME: 17:00 AA (, 07/14/2003 09:16 AM SSTANLEY ----'---------------------------- 171---- COMMENTS AND NOTES -------------------- Ile i CITY OF COLLEGE STATION WORK DUEST is PAGE 1 .�: REQ/JOB: WF0392538 / 001 PROJECT: REQUEST DATE: 4/18/03 PRINT DATE: 4/18/03 CREW: PRINT TIME: 12:02:50 SCHEDULE LOCATION: 3812 OLDENBURG LN START:DATES 4/18/03 77845 COMPLETION: 4/18/03 GEN. LOC: COLLEGE STATION LOC ID: 197216 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: K M CUSTOM HOMES (589-3739) ORIGIN: CUSTOMER -WALK IN USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE (1) 4" SEWER & (2) 3/4" WATER REQUEST COMMENTS DUPLEX - 3812/3814 OLDENBURG LANE (1) 4" SEWER & (2) 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ----------------------------------------------------------------------------- Application Number . . . . . 03-00001124 Date 4/17/03 Property Address . . . . . . 3812 OLDENBURG LN Property ID . . 244030-0409-0270 R# . . . . . . . . . . . . . R***** Tenant nbr, name . . . . . . 3814 OLDENBURG ALSO Application description . . . RESIDENTIAL, 2 UNITS NEW Subdivision Name . . . . . . EDELWEISS GARTENS PH 4 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . DUPLEX RESIDENTIAL Application valuation . . . . 181500 Owner Contractor EDELWEISS GARTEN VENTURE K M CUSTOM HOMES 311 CECILIA LOOP KENNY MELESKY COLLEGE STATION TX 778456310 8778 OLD RELIANCE RD BRYAN TX 77808 (979) 589-3739 ------ Structure Information DUPLEX ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB HEATED AREA 2750.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 6.00 NUMBER OF BEDROOMS 6.00 SEWER TYPE PUBLIC ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc LL/KENNY Permit Fee . . . . 706.00 Plan Check Fee .00 Issue Date . . . . 4/17/03 Valuation . . . . 181500 Expiration Date . . 10/14/03 Qty Unit Charge Per Extension BASE FEE 460.00 82.00 3.0000 THOU BLDG, VAL 100001-500000 246.00 ---------------------------------------------------------------------------- Special Notes and Comments ADD SMOKE DETECTOR(S) PER NOTES ON PLANS ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT ---------------------- BUILDING DEPT RE ESEJTATIVE:� APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ----------------------------------------------------------------------------- Page 2 Application Number 03-00001124 Date 4/17/03 ---------------------------------------------------------------------------- Special Notes and Comments MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS Provide detail of rated separation wall. 6 x 6 WWM @ 4' o c not allowed for stirrups in beams. ----------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 800.00 Fee summary Charged Paid Credited Due --------------------------- ------------------------------ Permit Fee Total 706.00 706.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 1150.00 1150.00 .00 .00 Grand Total 1856.00 1856.00 .00 .00 BUILDING DEPT APPLICANT ES T n Q��, APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX 1NWW.CI.COLLEGE-STATION. I A.US DATE: 4- I I ` if APPLICATION # 03 TEMP POLE # ADDRESS/LOCATION: D t/�e► �.:�r L c?t1C LOT �_ BLOCK SUBDIV ION (. e IV � 5 J�-a,V Zh 5 BUSINESS/OWNER NAME: CaS N ',ue5 Tot- PHONE:.l 0 �-7_1 -75 CONTRACTOR/HOMEOWNER: CONTRACTOR ADDRESS: /0 ELECTRICIAN: 4) PHONE: PLUMBER: I.N(a k HVAC: �:+^� �'� GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX =6ndscapePlans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTIOK STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ _.5=4"- ' M!� TOTAL AREA: Jq3V HEATED AREA 7)51) (Cost of Labor and Materials) PUBLIC SEWER 1 v Icy'OO NUMBER OF BEDROOMS: 3 Lj SEPTICJTREATMENT SYSTEM NUMBER OF BATHROOMS: �I SEWER TAP: INTERIOR WALL TYPE: S WATER TAP: EXTERIOR WALL TYPE: SIZE OTHER TAP: SIZE TEMP POLE GARAGE TYPE: SINGLE a ATTACHED SIGNATURE OF APPLICANT: FOUNDATION TYPE: ROOF TYPE: d`'q DOUBLE a TRIPLE a DETACHED CARPORT a nal e Only me YE NO fly Plans Examiner oning Official Energy Code Compliance Information % Glazing of exterior walls a �- Insulation R value of exterior walls R 13 Insulation R value of ceiling 1 (flat areas) 30 Insulation R value of ceiling 2 (vaulted areas/no attic) itj_ Glazing SHGC Glazing U-Factor . �A R value of ductwork C A/C SEER rating Z 7 c c c r 70-00' I ! I I I I a i I U' REAR SETBACK i -------------------- ---------- I ------ Uw�I m i N w I:i 00 10 7'� 10 1 I� I; P �I I I 'I i 5' WID S I I ! 18'-6' 24'-0' I 18'-6" ! 25' B.S.L. i i o j CONC j j O1 DRIVE j aI aaoa 1 rLAND V�'J DSCAPE SCAP OLDENBURG LANE egg SITE PLAN SCALE: 1770,70 EDELWIESS GARTENS 22 L Z3 L �-- ' • ' m 1111� 8'-11" ( 7'-3" I 7'-11.' 27'-1 1/2" a 54'-3" FLOOR PLAN ENERGY CODE ITEMWINDOW IN I N -R VALUE- TOTAL EXT WALL AREA =1 1 TOTAL EXT. OPENINGS= 152 S.F. PERCENT GE OF WALL OPENINGS= 8% PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# D j� DATE: zz BUILDING ADDRESS: n I. Foundation Requirements NA/dKj A. Concrete minimum fc of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown I ivy 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' Ion 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated w II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/ A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex 1. One -hour rated extending to roof deck E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX II. Framing: Floor, Wall, Ceiling and Roof Requirements continued NA/OK M. Span exceeding code tables must be engineered N. Rafter size, spacing, grade, roof slope & bracing (if required to reduce span) indicated on plans O. Roof covering 1. Roof decking indicated on plans 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs not allowed on zero lot line construction S. Protected openings on walls < three feet from property line III. Stairway Requirements OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge Vt 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements to be indicated onplans) K A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX C. Chimneys must extend at least three (3) feet higher than the highest point where it projects through the roof of a building & at least two (2) feet higher than any portion of the building within ten 10 feet horizontal V. Electrical Service Requirements NA/OK A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements NA/OK A. Pressure reducing valve required when water pressure exceeds 80 psi B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/OK A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: PIZ 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided tl 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements NA/ A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 N Permitted use for district Density requirements Minimum lot size Setbacks Easements Overhangs not allowed on zero lot line construction Required parking Street Ordinance Requirements NA/O Maximum drive width for residence is 28' combined for circular Minimum 30 feet from driveway to side(intersecting) street Driveway access to lesser street for corner lots PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX Subdivision Regulations — Ordinance 690 NA/OKJ Approved subdivision Plat filed 1 L Flood lain Regulations — Ordinance 1301 N 6K Does not block any water course or divert any flow Elevation certificate needed 1 Comments: ZONING OFFICIAL DATE l,� . C93 PLANS EXAMINER EDA E PORCH 7'-3" _ 1 7'-1 1 ° 19„ 19.. 27'-1 1/2" FLOOR PLAN ENERGY CODE ITEMS L I I N R VALUE= TOTAL EXT. WALL AREA =181-6 S.F. TOTAL EXT. OPEN!NCS= 152 S.F. PERCENTAGE OF WALL OPENINGS= 8%