HomeMy WebLinkAboutRES2003-01101PREPARED 11/14/03, 7:00:21 INSPECTION TICKET PAGE 3
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/14/03
------------------------------------------------------------------------------------------------
ADDRESS . : 1816 BROTHERS BLVD 4 SUBDIV: REGENCY SOUTH COMMON AREA
TENANT, NBR: WILLIAM KAUTZ
CONTRACTOR WILLIAM R KAUTZ PHONE (979) 3680
OWNER KAUTZ, WILLIAM R PHONE
PARCEL 538700-0001-0040
APPL NUMBER: 03-00001101 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 8/12/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00
9/12/03 AP 08/11/2003 03:14 PM MALFORD
B 01 9/12/03 DS BLDG, FRAMING TIME: 17:00
9/15/03 AP 09/12/2003 08:35 AM SSTANLEY
B130 01 9/18/03 OC BLDG, INSULATION TIME: 17:00
9/18/03 AP 09/18/2003 08:07 AM SSTANLEY
B125 01 11/ 4/pQ3 B BLDG, FINAL TIME: 17:00
�)V 03 11/13/2003 04:26 PM SSTANLEY
----------------------------------- CONTINUED ONTO NEXT PAGE ------------------------ ------
p j 0 ,
J% 1 0 Z, ! O In
CITY OF COLLEGE STATION
WORF QUEST
PAGE
1
REQ/JOB:
WF0442981 / 001 PROJECT:
REQUEST DATE:
8/06/03
PRINT DATE:
8/06/03
CREW:
PRINT TIME:
11:52:16
SCHEDULE
DAMES
LOCATION:
1816 BROTHERS BLVD 4
03
77845 COMPLETION:
8/06/03
GEN. LOC:
COLLEGE STATION LOC
ID: 135092
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION
PRIORITY: NORMAL
REQUESTOR:
WILLIAM R KAUTZ
ORIGIN: CUSTOMER -WALK
IN
USER ID:
SSTANLEY AUTH: SSTANLEY
WORK TYPE: ROUTINE
TEMP POLE PASSED
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
CITY OF COLLEGE STATION
WORK ;QUEST
PAGE
1
REQ/JOB:
WF0432555 / 001 PROJECT:
REQUEST DATE:
7/24/03
PRINT DATE:
7/24/03
CREW:
PRINT TIME:
10:11:07
SCHEDULE
DATES
LOCATION:
1816 BROTHERS BLVD 4
START:
7/24/03
77845
COMPLETION:
7/24/03
GEN. LOC:
COLLEGE STATION LOC ID: 135092
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
WILLIAM KAUTZ ORIGIN:
CUSTOMER -WALK
IN
USER ID:
SSTANLEY AUTH: SSTANLEY WORK TYPE:
ROUTINE
TEMP POLE
PASSED
TEMP POLE
PASSED
Category
code CS -CUSTOMER SERVICES CSCS
Task code:
SET UP NEW UTILITY ACCT SET
Facility
ID
Assigned Department:
OT-CUSTOMER SERVICE
CITY OF COLLEGE STATION
WORK 'QUEST
REQ/JOB: WF0397805 / 001
CREW:
LOCATION: 1816 BROTHERS BLVD 4
«i4*• PAGE
PROJECT: REQUEST DATE:
PRINT DATE:
PRINT TIME:
SCHEDULE
START:
77840 COMPLETION:
1
0203
5/02/03
10:15:55
DATES
03
5/02/03
GEN. LOC: COLLEGE STATION LOC ID: 135092
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: WILLIAM KAURTZ ORIGIN: CUSTOMER -WALK IN
USER ID: KELMENDORF AUTH: KELMENDORF WORK TYPE: ROUTINE
3/4" WATER 4" SEWER
3/4" WATER 4" SEWER
Category code
Task code:
Facility ID
Assigned Department:
CS -CUSTOMER SERVICES
SET UP NEW UTILITY ACCT
OT-CUSTOMER SERVICE
CSCS
SET
BUiL1)1NG PERMil' r
CITY OF COLLEGE 'STATION"
op
COLLEGE STATION, TX 77840-
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . .
. 03-00001101 Date 5/02/03
Property Address . . . . .
. 1816 BROTHERS BLVD 4
Property ID
538700-0001-0040
R ##
R38876
Tenant nbr, name . . . . .
. WILLIAM KAUTZ
Application description . .
. RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . .
. REGENCY SOUTH COMMON AREA
Property Use . . . . . . .
.
Property Zoning . . . . . .
. PLANNED UNIT DEVELOPMENT
Application valuation . . .
. 103752
Owner Contractor
------------------------ ------------------------
KAUTZ, WILLIAM R WILLIAM R KAUTZ
3937 MULLINS LOOP E
COLLEGE STATION
TX 77845 3937 MULLINS LOOP
E
COLLEGE STATION
TX 77845
(979) 3680
--------------------------
Structure Information -------------------------
Construction Type
. . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type .
. . . . . RESIDENTIAL -MULTI -FAMILY
Other struct info
. . . . . EXTERIOR WALL TYPE
BRICK/WOOD FRAP
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
CONCRETE SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
TBA
HEATED AREA
1572.00
INTERIOR WALL TYPE
WOOD FRAME
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
----------------------------------------------------------------------------
Permit . . . . .
. BUILDING PERMIT
Additional desc .
. KE
Permit Fee . . .
. 472.00 Plan Check Fee
.00
Issue Date . . .
. 5/02/03 Valuation . .
. . 103752
Expiration Date .
. 10/29/03
Qty Unit Charge Per
Extension
BASE FEE
460.00
4.00 3.0000
THOU BLDG, VAL 100001-500000
12.00
----------------------------------------------------------------------------
Special Notes and
Comments
PROVIDE ADDRESS ON BUILDING: FRONT - 5" HIGH NUMBERS
REAR - 2" HIGH
NUMBERS
ALL BRANCH CIRCUITS
THAT SUPPLY RECEPTACLES IN DWELLING
- -----------------------
----------
=-------------
BUILDING DEPT
REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 03-00001101 Date 5/02/03
----------------------------------------------------------------------------
Special Notes and Comments
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
Remove windows at dining room and garage. No opening
in walls that are within 3 feet of property ling. Such
wall shall be constructed as a 1-hour firewall.
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
BUILDING DEPT REPRESENTATIVE:
APPLICANT: W It \��
l3U1L1JlNG YEHMiT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
Fee summary
-----------------
Permit Fee Total
Plan Check Total
Other Fee Total
Grand Total
Charged
472.00
.00
750.00
1222.00
03-00001101
BUILDING DEPT REPRESENjTATIVE:
APPLICANT:
Paid
472.00
.00
750.00
1222.00
Credited
.00
.00
.00
.00
Page 3
Date 5/02/03
Due
.00
.00
.00
.00
TEMPORARY PULE PEHMiT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . .
Property Address . . .
Property ID . . . . . .
Application description
Subdivision Name . . .
Property Use . . . . .
Property Zoning . . . .
Application valuation .
Owner
------------------------
KAUTZ, WILLIAM R
3937 MULLINS LOOP E
. . . 03-00001460 Date 5/02/03
. . . 1816 BROTHERS BLVD 4
. . . 538700-0001-0040
. . . TEMP POLE
. . . REGENCY SOUTH COMMON AREA
PLANNED UNIT DEVELOPMENT
0
Contractor
------------------------
WILLIAM R KAUTZ
COLLEGE STATION
TX 77845
3937 MULLINS LOOP E
COLLEGE STATION
TX 77845
(979) 3680
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc .
. KE
Permit Fee . . .
. 20.00
Issue Date . . .
. 5/02/03
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
Fee summary
Charged
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
---------------------------------------- ----- -- ------- --------------
BUILDING DEPT REPRESENT A IVE:
APPLICANT: �I )�L --3-t'-z' __
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGESTATION.TX.US
Fa Ofte Use Only
DATE: 4- &,o3
APPLICATION # UJ - 1
TEMP POLE # ()"15 J 14-U V
ADDRESS/LOCATION: t,,,t„rcy� 16 t3Q4-%H C 9-1
LOT BLOCK SUBDIVISION
—� ��1,�'NC� SO�i row, _ 217
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER: Q tlttAM KA J-tz-. PHONE:
CONTRACTOR ADDRESS: 3 3i us19•..o �ee P C . S , "�wI —T?k`��"
ELECTRICIAN: '�B rB A9.4.�* ' PLUMBER: .r=-Q. ��LE 5 �.-v b ►+ac.
HVAC: T_taamua: tYe S 4e%Q 1.c.-ES GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL
DESCRIPTION OF WORK: C, dYr A4-��
STRUCTURE USE: S».�.An•.��� �(l�rn�.
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPR.
VALUATION: $ I 0 3,r7 S Z • oa TOTAL AREA: 203 (.
(Cost of Labor and Materials)
PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
El tl
SEWER TAP:
SIZE
WATER TAP: 1
SIZE
THER TAP:
TEMP POLE
GARAGE TYPE
SIZE
HEATED AREA: 1 a -
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS: 3
INTERIOR WALL TYPE: wserdl
EXTERIOR WALL TYPE: i. > �,ne,...�+• a
FOUNDATION TYPE: C.
ROOF TYPE:
SINGLE a DOUBLE [kr TRIPLE
ATTACHED a DETACHED a CARPORT
SIGNATURE OF APPLICANT:
Official Use Only
C ;n&l.
rES
Plans Examiner Zoni V Official
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling I (flat areas)
Insulation R value of ceiling 2 (vaulted areas/nd attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
,5?5
A/C SEER rating i �—