Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2003-01087
PREPARED 7/29/03, 9:34:21 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/29/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 3738 ESSEN LOOP SUBDIV: EDELWEISS GARTENS PH 1 CONTRACTOR T D T HOMES PHONE (979) 690-7117 OWNER EDELWEISS GARTEN VENTURE PHONE PARCEL 244030-0102-0090 APPL NUMBER: 03-00001087 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/24/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00 4/25/03 AP 04/24/2003 11:59 AM SSTANLEY SETBACKS PER STRINGS. SLAB GROUND @ LEFT BACK CORNER B d1 5/16/03 CH BLDG, FRAMING TIME: 17:00 > % 5/18/03 AP 05/16/2003 03:58 PM LLONG B125.E01 7/29/.03 B BLDG, FINAL TIME: 17:00 t G' er 07/29/2003 09:34 AM MRODGERS stone to sign -- ---------------------------`I'----- COMMENTS AND NOTES -------- 5 � 5 Linda Long - Insulation request inspecti esult, 3738 Essen Loop, #03�1087 Page 1 From: Brian Henry To: Long, Linda Date: 5/21/03 4:04PM Subject: Insulation request inspection result, 3738 Essen Loop, #03-1087 Print for File Inspected insulation, 3738 Essen Loop, #03-1087, Benchmark Homes, 5-21-03 Inspection result: Inspected OK for Good Cents CC: Stanley, Susan BUILDING PERMIT COLLEGE STATION, TX 77840•-' PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00001087 Date 4/16/03 Property Address . . . . . . 3738 ESSEN LOOP Property ID 244030-0102-0090 R # R111692 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . EDELWEISS GARTENS PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 130416 Owner Contractor ------------------------ ------------------------ EDELWEISS GARTEN VENTURE T D T HOMES 311 CECILIA LOOP GLENN THOMAS COLLEGE STATION TX 778456310 1110 12TH MAN COLLEGE STATION TX 77845 (979) 690-7117 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1536.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 553.00 Plan Check Fee .00 Issue Date . . . . 4/16/03 Valuation . . . . 130416 Expiration Date . . 10/13/03 Qty Unit Charge Per Extension BASE FEE 460.00 31.00 3.0000 THOU BLDG, VAL 1000017500000 93.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT 000, --------------------------------- - - -- --------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 03-00001087 Date 4/16/03 ---------------------------------------------------------------------------- Special Notes and Comments DRIVEWAY DISTANCE FROM CORNER: "NO RESIDENTIAL DRIVEWAY SHALL BE CONSTRUCTED WITHIN THIRTY FEET (301) OF THE CORNER OF A STREET INTERSECTION. THIS MEASUREMENT SHALL BE TAKEN FROM THE INTERSECTION OF PROPERTY LINES AT THE CORNER." ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE For residential applications with a glazing area that exceeds 150 of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS Other Fees . . . . . . . . . Fee summary Charged Permit Fee Total 553.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1303.00 BUILDING DEPT REPRESENTA APPLICANT: SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Paid Credited Due ------------------------------ 553.00 .00 .00 .00 .00 .00 750.00 .00 .00 1303.00 .00 .00 BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00001087 BUILDING DE APPLICANT: Page 3 Date 4/16/03 TEMPORARY POLE PERMIT CITY OF COLLEGE STATIOI 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00001088 Date 4/16/03 Property Address . . . . . . 3738 ESSEN LOOP Property ID 244030-0102-0090 R # R111692 Application description TEMP POLE Subdivision Name . . . . . . EDELWEISS GARTENS PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ EDELWEISS GARTEN VENTURE T D T HOMES 311 CECILIA LOOP GLENN THOMAS COLLEGE STATION TX 778456310 1110 12TH MAN COLLEGE STATION TX 77845 (979) 690-7117 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc SS Permit Fee . . . . 20.00 Issue Date . . . . 4/16/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary ----------------- Permit Fee Total Other Fee Total Grand Total Charged Paid -------------------- 20.00 20.00 45.00 45.00 65.00 65.00 -------------------------------------------- BUILDING DEPT REPRESENTPAIVE: / APPLICANT: Credited Due -------------------- .00 .00 .00 .00 .00 .00 CITY OF COLLEGE STATION WO] ZEQUEST PAGE 1 REQ/JOB: WF0392266 1 001 PROJECT: REQUEST DD TE: 4/17/PRINT 03 CREW: PRINT TIME: 9:23:05 LOCATION: 3738 ESSEN LOOP SCHEDULE STTART:DATES 4/17/03 77845 COMPLETION: 4/17/03 GEN. LOC: COLLEGE STATION LOC ID: 193900 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: T D T HOMES ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 3/4" WATER 4" SEWER ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 3/4" WATER 4" SEWER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- PLICATION FOR BUILDING PE T CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEGE-STATION.TX.US F« Oft* We arr DATE- 4-1 q—D 3_�_ /__ APPLICATION 0 3 /) -I U / TEMP POLE N 6'5 I OFSg ADDRESS/LOC`ATT N: �f LM r LOT BLOCK SUBDIVISION BUSINESS/OWNER NAME: � t. �� p PHONE: (oq q0k CONTRACTOR/HOMEOWNER: �' f rtr`/ & AS A-\ L- PHONE: 41 Z- S1 "Z 1 - C U► CONTRACTOR ADDRESS: viC ZZ ELECTRICIAN: Kku ` ` t_ PLUMBER: HVAC: Q % W" Mp,al� GOOD CENTS (Residential onry): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) >< NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: STRUCTURE USE: cal'\ t� F- N- VA-_ c k HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD AS) PROJECT REGISTRATION# EABPRJ VALUATION: $ TOTAL AREA --.HEATED AREA: (Gosnt Labbr and Materials) KrPUBLIC SEWER I" '8�.w NUMBER OF BEDROOMS: 21, SEPTIC/TREATMENT SYSTEM "SEWER TAP: C ( g SIZE I Eq'WATER TAQ: J StzE OTHER TAP: SIZE dTEMP POLE NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: GARAGE TYPE: SINGLE a DOUBLE ©__" TRIPLE Q ATTACHED ZrP ETACHED� [::] CARPORT a SIGNATURE OF APPLICANT: Official Use Only Plans Examiner Zoning Official ents. YES NO u Energy Code Compliance Information % Glazing of exterior walls (/g7 �7ZSs, /0,8 %D Insulation R value of exterior walls(-&4s {R13-sho4- ,34)j Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC T Glazing U-Factor m 6 R value of ductwork I A/C SEER rating jZ PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# DATE: BUILDING ADDRESS: 3138 &sc.,n I. Foundation Requirements NA/OK A. Concrete minimum f'c of 3000 PSI OK B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' Ion 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/OK A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex 1. One -hour rated extending to roof deck E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing plan or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX II. Framing: Floor, Wall, Ceiling and Roof Requirements continued NA/OK M. Span exceeding code tables must be engineered p N. Rafter size, spacing, grade, roof slope & bracing (if required to reduce span) indicated on plans O. Roof covering 1. Roof decking indicated on plans 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations ' R. Overhangs not allowed on zero lot line construction S. Protected openings on walls < three feet from property line III. Stairway Requirements A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements (to be indicated on plans) NA/OK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials --� PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX C. Chimneys must extend at least three (3) feet higher than the highest point where it projects through the roof of a building & at least two (2) feet higher than any portion of the buildingwithin ten 10 feet horizontal �'/ V. Electrical Service Requirements NA/OK A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements NA/OK A. Pressure reducing valve required when water pressure exceeds 80 psi B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/OK A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) VIII. Energy Requirements NA/OK A. Compliance software worksheet MECcheck submitted, or :. B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/OK Permitted use for district Density requirements Minimum lot size Setbacks Easements Overhangs not allowed on zero lot line construction 20' triangle clear at corner Required parking Street Ordinance Requirements NA/OK Maximum drive width for residence is 28' Minimum 30 feet from driveway to side(intersecting) street 01( PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX Subdivision Regulations — Ordinance 690 1 NA/0 K Approved subdivision A Plat filed A � Floodplain Reaulations — Ordinance 1301 OK 1 Does not block any water course Need elevation certificate ZONING OFFICIAL DATE PLANS EXAMINER DATE m� Mae - COL ry) N O O rO_ I 45.00, FOR EDELNEISS :GARTENS BENCHMARK HOMESSITE ��I LOT: 9 HEATED AREA: ��rj3fo 50, JTTT��iitSi °k BLOCK: 2 SECTION IASE i GLENN TkOMAS SCALE- I" - 20' ESSEN P SLAB AREA: I1976 SO. PHONE: FAX: (404) 6AO-1117 (4O9) 6°IO-7116 Permit Number MECcheck Compliance Report Checked By/Date 1995 MEC MECcheckSoftware Version 3.4 Release la Data filename: C:\Program Files\Check\MECcheck\MecCheck Docs\239BM.cck TITLE: BENCHMARK HOMES JOB 239 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 04/ 12/03 DATE OF PLANS: April 14, 2003 PROJECT INFORMATION: Job 239-Speck 3738 Essen Loop. Colleeege Station, TX 77845 COMPANY INFORMATION: Benchmark Homes 1110 12th Man Ct. College Station, Texas 77845 NOTES: Like Home Located @ 2313 & 2306 endal Green Circle 3705 Ardenne COMPLIANCE: Passes Maximum UA = 634 Your Home = 463 27.0% Better Than Code Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Ceiling (no attic) Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame, Double Pane with Low-E Door 2: Solid Door 3: Glass Floor 1: Unheated Slab -On -Grade, 0.0' insul. Air Conditioner 1: Electric Central Air, 12 SEER Furnace 1: Forced Hot Air, 80 AFUE Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1512 30.0 0.0 53 24 19.0 0.0 1 1728 13.0 3.4 105 187 0.650 122 21 0.130 3 21 0.420 9 163 0.0 170 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 1995 MEC requirements in MECcheckVersion 3.4 Release la and to comply with the mandatory requirements listed in the MEC check Inspection Checklist. Builder/Designer Date MECcheck Inspection Checklist 1995 MEC MECcheckSoftware Version 3.4 Release la DATE: 04/12/03 TITLE: BENCHMARK HOMES JOB 239 Bldg. Dept. Use [ll I I [ ] I I I I [ ] I Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: 1. Wall ] : Wood Frame, 16" o.c., R-13.0 cavity + R-3.4 continuous insulation Comments: Doors: 1. Door 2: Solid, U-factor: 0.130 Comments: Floors: 1. Floor 1: Unheated Slab -On -Grade, R-0 (uninsulated) Comments: Heating and Cooling Equipment: 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number 2. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] All ducts must be sealed with mastic and fibrous backing tape. Pressure -sensitive tape may be used for fibrous ducts. Duct tape is not permitted. [ ] The HVAC system must provide a means for balancing air and water systems. I Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. I Swimming Pools: [ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. I Heating and Cooling Piping Insulation: [ ] I HVAC piping conveying fluids above 120 OF or chilled fluids below 55 OF must be insulated to the I levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range ( F) 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)