HomeMy WebLinkAboutRES2003-01083PREPARED 8/28/03, 8:41:41 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/28/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 1816 BROTHERS BLVD 20 SUBDIV: REGENCY SOUTH, BLOCK 1 REPLAT CONTRACTOR T D T HOMES PHONE (979) 690-7117 OWNER GDT, INC PHONE PARCEL 538701-0001-0050 APPL NUMBER: 03-00001083 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT= BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 5/19/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00 5/20/03 AP 05/19/2003 09:19 AM SSTANLEY Says he talked to Katy about this on Thursday SETBACKS PER STRINGS. SLAB GROUND Q RIGHT BACK CORNER B1 01 6/12/03 CH BLDG, FRAMING TIME: 17:00 6/13/03 AP 06/12/2003 10:13 AM LLONG B125 01 8/21/03 CH BLDG, FINAL TIME: 17:00 8/27/03 CA 08/21/2003 10:55 AM KELMENDORF CANCELLED PER CHRIS. B125 02 8 28 03 BI BLDG, FINAL TIME: 17:00 SWQ' (,1A AP 08/28/2003 08:41 AM MALFORD -= ------------------ COMMENTS AND NOTES -------------------------------------- f Linda Long - Insulation request inspecti--- result, 1816 Brothers, #20, #03-1083 Page 1 From: Brian Henry To: Long, Linda Date: 6/17/03 1:35PM Subject: Insulation request inspection result, 1816 Brothers, #20, #03-1083 Print for File Inspected insulation, 1816 Brothers, #20, #03-1083, Thomas Homes 6-17-03 Inspection result: Inspected OK for Good Cents CC: Stanley, Susan Linda Long - Insulation request inspecti result, 1816 Brothers, #20, #03-1083 Page 1 From: Brian Henry To: Long, Linda Date: 6/17/03 10:35AM Subject: Insulation request inspection result, 1816 Brothers, #20, #03-1083 Print for File Inspected insulation, 1816 Brothers, #20, #03-1083, Benchmark Homes, 6-17-03 Inspection result: Inspected OK for Good Cents CC: Stanley, Susan CITY OF COLLEGE STATION WORF E-QUEST PAGE 1 REQ/JOB: WF0398665 / 001 PROJECT: REQUEST DATE:TE: 5/05/PRINT 03 CREW: PRINT TIME: 12:34:05 SCHEDULE DATES LOCATION: 1816 BROTHERS BLVD 20 START: 5/05/03 77845 COMPLETION: 5/05/03 GEN. LOC: COLLEGE STATION LOC ID: 191180 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: T D T HOMES ORIGIN: CUSTOMER -WALK IN USER ID: KELMENDORF AUTH: KELMENDORF WORK TYPE: ROUTINE 3/4" WATER 4" SEWER 3/4" WATER 4" SEWER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE TPl. 170&13 1L[)ING PE ITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEGE.STATION.TX.US ADDRESS/LOCATION: LOT Is R'-- Bl. BUSINESS/OWNER N/ r� off" Um ow IT DATE: q-I L4—C)' 3 APP"TM R ()15-1 (783 TEMP POLE # 03 -1 4 D W;; C.- CONTRACTOR/HOMEOWNER: k Dr LAomy-S PHONE: 411 Z - 2,F7? Cr= CONTRACTOR ADDRESS: ((1() l Z-%�, Arn1 L CS, 7, 5 ELECTRICIAN: ie4kH E ( =( PLUMBER: Fi HVAC: JtL& &giNc 1 GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVAT``ION SWIMMING POOL DESCRIPTION OF WORK: Al;r--LA. STRUCTURE USE: o"S Q C ( P+ ���y � GyNr HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD AS) PROJECT REGISTRATION# EABPRJ VALUATION: $ _ 0 j(OTAL AREA: 2-0" HEATED AREA: 1 (o3 (Cost of Labor and Materials) j ✓ 2 "PUBLIC SEWER I b (P " `g- NUMBER OF BEDROOMS: J SEPTICJTREATMENT SYSTEM SEWER TAP: 411 SIZE C "WATER TAP: 3 " SIZE OTHER TAP: SIZE TEMP POLE I46N r, GARAGE TYPE: SINGLE Q ATTACHED SIGNATURE OF APPLICANT: NUMBER OF BATHROOMS: INTERIOR WALL TYPE EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE Er l DETACHED^ a Sf focj' , TRIPLE Q CARPORT a Official Use Only ents: YES NO Plans Examiner Zoning Official • Energy Code Compliance Information % Glazing of exterior walls lq.E /b Insulation R value of exterior walls 13 Insulation R value of ceiling 1 (flat areas) 3(D Insulation R value of ceiling 2 (vaulted areas/no attic) 30 Glazing SHGC .3 Glazing U-Factor . b� R value of ductwork (O A/C SEER rating 1 2- SO LAA tDt 5 wo it' 4cc,vj 0 cr ci if OMMW kJ i K - \-K ,bO\ 0 Fuc —P D-r Homc--q kir- plbA- �z-jr-mckl �50V- Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC REScheckSoftware Version 3.5 Release la Data filename: C:\Program Files\Check\REScheck\REScheck docs\l58TDT.cck TITLE: TDT HOMES 4158 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 04/12/03 DATE OF PLANS: 4/14/03 PROJECT INFORMATION: TDT JOB 158 1816 Brothers Blvd. #20 1631 S/Ft Garden Home Regency South COMPANY INFORMATION: TDT HOMES 1110 12TH MAN COURT COLLEGE STATION, TX 77845 690 7117 PHONE 690 7118 FAX COMPLIANCE: Passes Maximum UA = 682 Your Home UA = 530 22.3% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.34 Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.34 Door 1: Solid Door 2: Glass SHGC: 0.34 Floor 1: Slab-On-Grade:Unheated Insulation depth: 0.0' Furnace 1: Forced Hot Air, 80 AFUE Air Conditioner 1: Electric Central Air, 12 SEER Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1996 13.0 3.4 120 242 0.650 157 20 0.400 8 18 1.310 24 212 0.0 221 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in RES checkVersion 3.5 Release 1 a (formerly MECchecl and to comply with the mandatory requirements listed in the REScheckInspection Checklist. A � '�\n �1 Builder/Designer Date _ l `-�)/ REScheck Inspection Checklist 2000 IECC RES check Software Version 3.5 Release la DATE: 04/ 12/03 TITLE: TDT HOMES #158 Bldg. Dept. Use Above -Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity + R-3.4 continuous insulation Comments: I Windows: [ ] I 1. Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.650 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] I 1. Door 1: Solid, U-factor: 0.400 Comments: [ ] 2. Door 2: Glass, U-factor: 1.310 Comments: I Floors: [ ] I 1. Floor 1: Slab -On -Grade: Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: [ ] I 1. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number [ ] I 2. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number I Solar Heat Gain Coefficient: [ ] I The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. I Air Leakage: [ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] I Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. I Materials Identification: [ ] I Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] I Materials and equipment must be identified so that compliance can be determined. [ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] I Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. Cooling ducts with exterior insulation must be covered with a vapor retarder. Air filters are required in the return air system. The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ J ( Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ J Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the I levels in Table 2. i Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) r/ PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX PLAN REVIEW/PERMIT NUMBER# DATE: BUILDING ADDRESS: `1 1 18110 (�rdl�ne�s $ t vCl . I. Foundation Requirements NA/OK A. Concrete minimum f'c of 3000 PSI B. Minimum four 4 inch slab thickness C. Vapor barrier 1. 6 mil poly D. Slab/beam or pier layout shown 1. Footings/beams are continuous over the length and width of foundation 2. Dimensions 3. Footings 30" exterior, 24" interior unless over 60' Ion 4. Spacing of beams does not exceed 15' E. Reinforcement details to meet minimum requirements 1. Slab reinforcement 2. Exterior beam reinforcement 3. Interior beam reinforcement 4. Masonry fireplace foundation reinforcement F. Wood foundation details indicated II. Framing: Floor, Wall, Ceiling and Roof Requirements NA/OK A. Girder or sill dimensions, grade & species B. Floor joist size, spacing, grade & direction of span indicted on plans C. Treated sill plate or bottom plate D. Tenant separation in duplex 1. One -hour rated extending to roof deck E. Header sizes indicated on plans F. Emergency bedroom egress 1. Exit direct to outside 2. O enable window a. Twenty 20 inch clear width by twenty-four 24 inch clear height b. Maximum sill height of forty-four 44 inches above finished floor G. O enable bathroom window required when mechanical ventilation is not provided H. Stud grade andspacing I. Exterior wall details 1. Exterior wall covering indicated on plans 2. Sheathing indicated on plans 3. Moisture barrier indicated on plans J. Roof framing Ian or elevation shown K. Ceiling joist size, spacing, grade and direction of span indicated on plans L. Attic access location and size indicated on plans PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX H. Framing: Floor, Wall, Ceiling and Roof Requirements continued NA/OK M. Span exceeding code tables must be engineered N. Rafter size, spacing, grade, roof slope & bracing (if required to reduce span) indicated on plans O. Roof covering 1. Roof decking indicated on plans 2. Moisture barrier indicated on plans P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade & location indicated on plans Q. Tempered Glass required in all hazardous locations R. Overhangs not allowed on zero lot line construction S. Protected openings on walls < three feet from property line Ill. Stairway Requirements NA/OK A. Stairway Details 1. Maximum riser height 7-3/4 inches 2. Minimum tread width 10 inches 3. Stairway risers are uniform 4. Stairway width not less than 36 inches 5. Stairway headroom not less that six ft. eight 6-8 B. Winder details 1. Treads a minimum of six 6 inches on narrow edge 2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the narrow edge C. Spiral stairway details 1. Riser height less than nine and one-half 9-1/2 inches 2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12) inches from the narrow edge 3. Stairway width not less than twenty-six inches 4. Headroom required not less than six ft six 6-6 inches 5. All treads must be identical D. Guards/handrail details 1. Guards required when a porch, deck, balcony or landing is thirty (30) inches above grade or finished floor 2. Handrails are required on stairways located two or more risers above floor/grade 3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the leading edge of the tread 4. Handrails must not project more than four & one-half (4-1/2) inches into width of a stairway 5. Guards must be a minimum of thirty-six 36 inches above finished floor 6. Guards & handrails along open-side(s) of stairway must have intermediate railing or uprights that prevent the passage of a four 4 inch sphere IV. Fireplace Requirements (to be indicated on plans) NA/OK A. Hearth extensions 1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward 2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward B. Masonry fireplace requires 2" clearance from all combustible materials PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX C. Chimneys must extend at least three (3) feet higher than the highest point where it projects through the roof of a building & at least two (2) feet higher than any portion of the building within ten 10 feet horizontal V. Electrical Service Requirements NA/OK A. Electrical plan to include: 1. Electrical fixtures & switches indicated 2. Smoke detector locations indicated as required 3. GFI circuits indicated where required 4. Arc fault protection for bedroom circuits 5. Panel location VI. Plumbing Requirements NA/OK A. Pressure reducing -valve required when water pressure exceeds 80 psi B. Plumbing access to bathtubs C. Means for thermal expansion provided when required D. Water heaters elevated 18" when installed in the garage or room directly off garage VII. Mechanical Requirements NA/OK A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to outside excludes ductless units B. Attic installed H.V.A.C. requirements: 1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment must be provided 2. Attic access located within 20 feet of equipment C. Combustion air supplied for gas appliances when required) Vill. Energy Requirements NA/OK A. Compliance software worksheet MECcheck submitted, or B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc. Zoning Ordinance Requirements — Ordinance 850 NA/OK Permitted use for district Density requirements Minimum lot size Setbacks Easements Overhangs not allowed on zero lot line construction 20' triangle clear at corner Required parking Street Ordinance Requirements NA/OK Maximum drive width for residence is 28' Minimum 30 feet from driveway to side(intersecting) street PLAN REVIEW ONE and TWO FAMILY OCCUPANCY REQUIREMENTS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TEXAS 77840 (979) 764-3570; (979) 764-3496 FAX Subdivision Regulations — Ordinance 690 NA/OK Approved subdivision I Plat filed I Floodplain Regulations — Ordinance 1301 NA/OK� Does not block any water course Need elevation certificate ZONING OFFICIAL DATE PLANS EXAMINER DATE BUILDING PERMIT CITY OF COLLEGE STATIO 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: ---------------------------------------------------------------------------- (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00001083 Date 5/05/03 Property Address . . . . . . 1816 BROTHERS BLVD 20 Property ID . . 538701-0001-0050 R # . . . R109353 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . REGENCY SOUTH, BLOCK 1 REPLAT Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED UNIT DEVELOPMENT Application valuation . . . . 136092 Owner Contractor ------------------------ GDT, INC ------------------------ T D T HOMES 1110 12TH MAN CIR GLENN THOMAS COLLEGE STATION TX 778458978 1110 12TH MAN COLLEGE STATION TX 77845 (979) 690-7117 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1631.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KE Permit Fee . . . . 571.00 Plan Check Fee .00 Issue Date . . . . 5/05/03 Valuation . . . . 136092 Expiration Date . . 11/01/03 Qty Unit Charge Per Extension BASE FEE 460.00 37.00 3.0000 THOU BLDG, VAL 100001-500000 111.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT --------------------------------------- ---- ------ [P --------------------- BUILDING DEPT EPR S TIVE: APPLICANT n . ,�.,� BUILDING PERMIT CITY OF COLLEGE STATIOI 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00001083 Date 5/05/03 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged P�'d J��Cre to Due ---------------------------------------- ----- - -- ------------------ BUILDING DEPT REPRESENTATIVE : ii(�IJ L APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATIOT 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Permit Fee Total 571.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1321.00 ------------------ BUILDING L APPLICANT: 03-00001083 571.00 .00 .00 .00 750.00 .00 1321.00 .00 Page 3 Date 5/05/03 .00 .00 .00 .00