INSPECTION TICKET
PAGE 1
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 8/28/03
------------------------------------------------------------------------------------------------
ADDRESS
. : 1816 BROTHERS BLVD
21 SUBDIV: REGENCY SOUTH,
BLOCK 1 REPLAT
CONTRACTOR T D T HOMES
PHONE (979) 690-7117
OWNER
GDT, INC
PHONE
PARCEL
538701-0001-0060
APPL NUMBER: 03-00001081 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
5/19/03 OC
BLDG, FOUNDATION -SLAB TIME: 17:00
5/20/03 AP
05/19/2003 09:18 AM SSTANLEY
Says he talks to Katy on Thursday
SETBACKS PER STRINGS. SLAB GROUND @ RIGHT
BACK CORNER.
s
B115101
6/12/03 CH
BLDG, FRAMING TIME: 17:00
6/13/03 AP
06/12/2003 10:14 AM LLONG
B12501
8/21/03 CH
BLDG, FINAL TIME: 17:00
8/27/03 CA
08/21/2003 11:18 AM KELMENDORF
PER CHRIS
B125102
8/28/03 BI
BLDG, FINAL TIME: 17:00
D 03 G H 6
08/28/2003 08:42 AM MALFORD
---------------- ----- CONTINUED ONTO NEXT PAGE -----------------------------------
Lau', m c6(\*e4y\
Linda Long - Insulation request inspectio sult, 1816 Brothers #21 #03-1081 Page 1
From:
Brian Henry
To:
Long, Linda
Date:
6/17/03 10:33AM
Subject:
Insulation request inspection result, 1816 Brothers #21 #03-1081
Print for File
Inspected insulation,
1816 Brothers #21 #03-1081, Benchmark Homes, 6-17-03
Inspection result:
Inspected OK for Good Cents
CC:
Stanley, Susan
CITY OF COLLEGE STATION
WOR .EQUEST
PAGE
1
REQ/JOB:
WF0416087 / 001 PROJECT:
REQUEST DATE:
6/09/PRINT 03
CREW:
PRINT TIME:
16:06:01
SCHEDULE
DATES
LOCATION:
1816 BROTHERS BLVD 21
03
77845
COMPLETION:
6/09/03
GEN. LOC:
COLLEGE STATION LOC ID:
191182
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
TDT HOMES (690-7117) ORIGIN:
CUSTOMER -WALK
IN
USER ID:
LLONG AUTH: LLONG WORK
TYPE:
ROUTINE
3/4" WATER
AND 4" SEWER
3/4" WATER
AND 4" SEWER
Category
code CS -CUSTOMER SERVICES
CSCS
Task code:
SET UP NEW UTILITY ACCT
SET
Facility
ID
Assigned Department:
OT-CUSTOMER SERVICE
CITY OF COLLEGE STATION
WORK
!QUEST
PAGE
1
REQ/JOB:
WF0398664 /
001 PROJECT:
REQUEST DATE:
5/05/PRINT 03
CREW:
PRINT TIME:
12:33:13
SCHEDULE
DATES
LOCATION:
1816 BROTHERS BLVD 20
START:
5/05/03
✓ 77845 COMPLETION:
5/05/03
GEN. LOC:
COLLEGE STATION LOC
ID: 191180
REF NBR:
REQ DEPT:
DE -BUILDING
INSPECTION
PRIORITY: NORMAL
REQUESTOR:
T D T HOMES
ORIGIN: CUSTOMER -WALK
IN
USER ID:
KELMENDORF
AUTH: KELMENDORF
WORK TYPE: ROUTINE
3/4" WATER 4" SEWER
3/4" WATER 4" SEWER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
No
T
?i`' _ LLE TATIO,
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00001081 Date 5/05/03
Property Address . . . . . . 1816 BROTHERS BLVD 21
Property ID . . 538701-0001-0060
R # . . . . . . . . . . . . . R109354
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . REGENCY SOUTH, BLOCK 1 REPLAT
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED UNIT DEVELOPMENT
Application valuation . . . . 155892
Owner Contractor
------------------------ ------------------------
GDT, INC T D T HOMES
1110 12TH MAN CIR GLENN THOMAS
COLLEGE STATION TX 778458978 1110 12TH MAN
COLLEGE STATION TX 77845
(979) 690-7117
-------------------------- Structure Information -------------------------
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1644.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . KE
Permit Fee . . . . 628.00 Plan Check Fee .00
Issue Date . . . . 5/05/03 Valuation . . . . 155892
Expiration Date . . 11/01/03
Qty Unit Charge Per Extension
BASE FEE 460.00
56.00 3.0000 THOU BLDG, VAL 100001-500000 168.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
-----------------------------------------
BUILDING DEPT RFiPfhSENTATIrV-\ Z
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATIO]
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 03-00001081 Date 5/05/03
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Fee summary
-----------------
Permit Fee Total
Plan Check Total
Charged
628.00
.00
Paid Credited Due
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -IN - - - - - - / t ---
BUILDING DEPT a RESENTATI
APPLICANT:
.00 .00
.00 .00
-----------------
BUILDING PERMIT
CITY OF COLLEGE STATIO"
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number 03-00001081 Date 5/05/03
Other Fee Total 750.00 750.00 .00 .00
Grand Total 1378.00 1378.00 .00 .00
BUILDING
APPLICANT:
a+r
ILICATION FOR BLITLIDAG' M r DATE- 4- I N- D 3
CITY OF COLLEGE STATION AMrATM #
1101 TEXAS AVENUE O 3- f SooZ
COLLEGE STATION. TX 77840 TEMP POLE u f
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGESTATION.TX.US
ADDRESS/LOCATION:_�p'
LOT_ BLOCK SUBDIVISION
Z
BUSINESS/OWNER NAME: ` D== pP, 2!�- S (JD- �_ 15 7)PHONE:
CONTRACTOR/HOMEOWNER: T t4OMr—_S PHONE: 1 I z- Z� 1
CONTRACTOR ADDRESS:
ELECTRICIAN: — ��r PLUMBER: _ 4
HVAC:� ��- ; Lc- ; 2 GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (�1 o alt P rtia
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) W CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK:
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: Uez:5—
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPR.'
VALUATION: $ I D 4 T AL AREA:
(Cost -of Lab6rr and Materials)
PUBLIC SEWER /1 °� NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM
U J
� CWER TAP: tl
SIZE
[0- WATER TAP: 3 "
SIZE
OTHER TAP:
SIZE
N OUP F%-] TEMP POLE
GARAGE TYPE: SINGLE a
ATTACK
SIGNATURE OF APPLICANT:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE Qr TRIPLE
Official Use Only
HEATED AREA:
�I
,Coarrlments:
(YE5 or O
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
KA
m
r
KA
5 IB'11'4q" W — 50.00
N I5'11'4q" E — 50.00
P
co
r
eA
FOR LOT ':• REGENCY SOUTH ► ATM � 1,644 so. Fr. BENCHMARK MONIES
!j � �� FLAN LOT: T>•IOMns
�. _ BLOCK: I SUBDIVISION sue ,mow. 2,362 so. Fr. �, F",
(aw) wo-nn (4w) GM-7M
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release la
Data filename: C:\Program Files\Check\REScheck\REScheck docs\157TDT.cck
TITLE: TDT JOB 157/Burnside
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 04/12/03
DATE OF PLANS: 4/14/03
PROJECT INFORMATION:
JOB 157 - Burnside
1816 Brothers Blvd. #21
Regency South Lot 6R
College Station, TX 77845
COMPANY INFORMATION:
TDT Homes
l 110 12th Man Court
College Station, TX 77845
690 7117 Phone
4122878
NOTES:
Like Jobs 139 #25, 140 #24 & 141 #23 in Regency South
COMPLIANCE: Passes
Maximum UA = 660
Your Home UA = 483
26.8% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.40
Ceiling 1: Flat Ceiling or Scissor Truss
Ceiling 2: Cathedral Ceiling (no attic)
Wall 1: Wood Frame, 16" o.c.
Window l: Metal Frame:Double Pane with Low-E
SHGC: 0.34
Door 1: Solid
Door 2: Glass
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor
UA
1596
30.0
0.0
56
48
30.0
0.0
2
1692
13.0
3.2
104
160
0.650
104
21
0.350
7
20
0.690
14
SHGC: 0.84
Floor 1: Slab -On -Grade: Unheated 188 0.0 196
Insulation depth: 0.0'
Furnace 1: Forced Hot Air, 80 AFUE
Air Conditioner 1: Electric Central Air, 12 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release la (formerly MECchec/ and to comply with the mandatory requirements listed in
the RESchecklnspection Checklist. 4l �4a73
Builder/Designer Date
REScheck Inspection Checklist
2000 IECC
REScheckSoftware Version 3.5 Release la
DATE: 04/12/03
TITLE: TDT JOB 157Burnside
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
[ ] 2. Ceiling 2: Cathedral Ceiling (no attic), R-30.0 cavity insulation
Comments:
Above -Grade Walls:
[ ] 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity + R-3.2 continuous insulation
Comments:
Windows:
[ ] 1. Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.650
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
[ ] 1. Door 1: Solid, U-factor: 0.350
Comments:
[ ] 2. Door 2: Glass, U-factor: 0.690
Comments:
Floors:
[ ] 1. Floor 1: Slab -On -Grade: Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
[ ] 1. Furnace 1: Forced Hot Air, 80 AFUE or higher
Make and Model Number
[ ] 2. Air Conditioner 1: Electric Central Air, 12 SEER or higher
I Make and Model Number
Solar Heat Gain Coefficient:
The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
3" clearance from insulation.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly
marked on the building plans or specifications.
Duct Insulation:
[ ] Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
Cooling ducts with exterior insulation must be covered with a vapor retarder.
Air filters are required in the return air system.
The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 OF must be insulated to the
I levels in Table 2.
Table 1: Minimum Insulation Thickn--- for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non -Circulating Runouts Circulating Mains and Runouts
Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness in Inches by
Pipe Sizes
Piping System Types
Range F
2" Runouts
1" and Less
1.25"
to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER#
DATE:
0 -0 l
4116103
BUILDING ADDRESS:
co 2�S
I. Foundation Requirements
NA/OK
A. Concrete minimum f'c of 3000 PSI
Q
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' long)
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/OK
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
1. One -hour rated extending to roof deck
E. Header sizes indicated on plans
OK
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, grade and direction of span indicated on plans
L. Attic access location and size indicated on plans
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
NA/OK
M. Span exceeding code tables must be engineered
N. Rafter size, spacing, grade, roof slope & bracing (if required to reduce span) indicated
on plans
O. Roof covering
1. Roof decking indicated on plans
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs not allowed on zero lot line construction
S. Protected openings on walls < three feet from property line
III. Stairway Requirements
NJOK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements (to be indicated on plans)
NA/ K
A. Hearth extensions
--
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of
the building within ten 10 feet horizontal
0 K
V. Electrical Service Requirements
NA/OK
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
NA/OK
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N OK
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
N OK
A. Compliance software worksheet MECcheck submitted, or
j<
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NA/OK
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Overhangs not allowed on zero lot line construction
20' triangle clear at corner
Required parking
Street Ordinance Requirements
NA/OK
Maximum drive width for residence is 28'
Minimum 30 feet from driveway to side(intersecting) street
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
Subdivision Regulations — Ordinance 690 NA/OK
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301 NA/OK
Does not block any water course
Need elevation certificate
ZONING OFFICIAL
PLANS EXAMINER
DATE
o3
DATE