HomeMy WebLinkAboutRES2003-01074PREPARED
8/13/03, 6:59:40
INSPECTION TICKET
PAGE
5
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE
8/13/03
------------------------------------------------------------------------------------------------
ADDRESS
. : 5118 SYCAMORE HILLS
DR SUBDIV: PEBBLE CREEK
CONTRACTOR MARIOTT HOMES INC
PHONE (979) 696-1787
OWNER
PEBBLE CREEK DEVELOPMENT
CO PHONE
PARCEL
497900-0030-0270
APPL NUMBER: 03-00001074 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
5/22/03 TB
BLDG, FOUNDATION -SLAB TIME: 17:00
5/22/03 AP
05/21/2003 04:13 PM KELMENDORF
SLAB GROUND BACK LEFT CORNER IN BATHROOM
STRINGS ON SETBACKS, OKAY
Bil 01
7/08/03 TB
BLDG, FRAMING TIME: 17:00
7/08/03 AP
07/08/2003 09:05 AM LLONG
B13Q O1
7/09/03 TB
BLDG, INSULATION TIME: 13:00
11
7/10/03 AP
07/09/2003 08:13 AM KELMENDORF
t
tomorrow after lunch (7/10/03)
BlA 01
8/13/03 I
BLDG, FINAL TIME: 17:00
08/12/2003 02:49 PM SSTANLEY
terry to sign
---------------------------------
COMMENTS AND NOTES --------------------------------------
tj e,t opj
s s
5
��wf . tl W_q�
CITY OF COLLEGE STATION
WORK QUEST
PAGE
1
REQ/JOB:
WF0393844 / 001 PROJECT:
REQUEST DATE:
4/23/03
PRINT DATE:
4/23/03
CREW:
PRINT TIME:
10:38:03
SCHEDULE
DATES
LOCATION:
5118 SYCAMORE HILLS DR
03
77845 COMPLETION:
4/23/03
GEN. LOC:
COLLEGE STATION LOC
ID: 195374
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION
PRIORITY: NORMAL
REQUESTOR:
MARIOTT HOMES (696-1787)
ORIGIN: CUSTOMER -WALK
IN
USER ID:
LLONG AUTH: LLONG
WORK TYPE: ROUTINE
4" SEWER
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
AND 3/4" WATER
4" SEWER AND 3/4" WATER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
BU T 'FRMI •+
iCIT-i'EXA6 AVE
_ M
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 03-00001074 Date 4/21/03
Property Address . .
. . . . 5118 SYCAMORE HILLS DR
Property ID
497900-0030-0270
R # • . . • • •
R112673
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . PEBBLE CREEK
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 180404
Owner
Contractor
------------------------
PEBBLE CREEK DEVELOPMENT
-------------.-----------
CO MARIOTT HOMES INC
%YOUNG BROTHERS
LARRY MARIOTT
PO BOX 1800
209 ROCK PRAIRIE RD
WACO
TX 767031800 COLLEGE STATION TX 77845
(979) 696-1787
--------------------------
Structure Information -------------------------
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 3.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2653.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
LL/LARRY
Permit Fee . . . .
703.00 Plan Check Fee .00
Issue Date . . . .
4/21/03 Valuation . . . . 180404
Expiration Date . .
10/18/03
Qty Unit Charge
Per Extension
BASE FEE 460.00
81.00 3.0000
THOU BLDG, VAL 100001-500000 243.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT
SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS
WITHIN 20 FEET OF MECHANIC E IPMENT
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEX,kS AVE " -
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
2
Application Number . . . . . 03-00001074 Date
4/21/03
----------------------------------------------------------------------------
Special Notes and Comments
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL
350.00
WATER TAP 3/4" CITY INSTL
400.00
Fee summary Charged Paid Credited Due
----------------------------------------
-----------------
Permit Fee Total 703.00 703.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1453.00 1453.00 .00
.00
BUILDING DEPT REPRESENTATIV�E:
APPLICANT: 1171?111'1, l f
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
03-00001075 Date
4/21/03
Property Address . . . . . .
5118 SYCAMORE HILLS DR
Property ID . .
497900-0030-0270
R # . . . . . . . . .
R112673
Application description . . .
TEMP POLE
Subdivision Name . . . . . .
PEBBLE CREEK
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
PEBBLE CREEK DEVELOPMENT CO
------------------------
MARIOTT HOMES INC
%YOUNG BROTHERS
LARRY MARIOTT
PO BOX 1800
209 ROCK PRAIRIE RD
WACO TX 767031800
COLLEGE STATION
TX 77845
(979) 696-1787
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . LL/LARRY
Permit Fee . . . . 20.00
Issue Date . . . . 4/21/03
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
Fee summary Charged
---------------------------
Paid Credited
------------------------------
Due
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
---------------------------------- -------------------------
BUILDING DEPT REPRESENTATIVE: �—
APPLICANT:
APPLICATION FOR BUILDING.PERMIT
CITY OF COLLEGE STATION
E3 1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEG E-STATION.TX.US
ADDRESS/LOCATION 12
'5/ -
LOT jBLOCK / SUBDIVISION
BUSINESS/OWNER NAME:
CONTRACTOR/HOMEOWNER:
CONTRACTOR ADD S:
ELECTRICIAN.
HVAC: 41RI Di —
PHONE: /
PHONE: 96
GOOD CENTS (Residential only): 90
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK:
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) P JECT REGISTRATION# EAABBP%RJ
VALUATION: $ TOTAL AREA: HEATED AREA:
(Cost of La and Materials)
IQ PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP: /J
I—t SIZE
WATER TAP: //
Sim
NUMBER OF BEDROOMS
NUMBER OF BATHROOMS
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
OTHER TAP: FOUNDATION TYPE:
SIzE
FZA ✓ TEMP POLE ROOF TYPE:
GARAGE TYPE: SINGLE a DOUBLE F—] TRIPLE
ATTACHED E DETACHE��14
DE-1 R
SIGNATURE OF APPLICANT: rA DAI
0
�
Okla/ Use Only 5 b �_ menu:
YES or NO
Plans Examiner Zoning Official
Qrj
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
.65
R value of ductwork K,i
A/C SEER rating
01 S 1 TE FLAN RUMUME, NONE WALE,0.20-0.
NORTH
LOT: 27
BLOCK= 30
SUBDIVISION:
PEBBLE CREEK
PHASE 9A
COLLEGE STATION, TEXAS
BRAZOS COUNTY
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# DATE:
63- y l5 03
BUILDING ADDRESS:
5 �I S CamoCe 5 t
I. Foundation Requirements
NA/OK
A. Concrete minimum f'c of 3000 PSI
OK
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' Ion
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/OK
A. Girder or sill dimensions, grade & species
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
1. One -hour rated extending to roof deck
E. Header sizes indicated on plans
p
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, rade and direction of span indicated on plans
L. Attic access location and size indicated on plans
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
NA/OK
M. Span exceeding code tables must be engineered
N. Rafter size, spacing, grade, roof slope & bracing (if required to reduce span) indicated
on plans
O. Roof covering
1. Roof decking indicated on plans
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
p,
R. Overhangs not allowed on zero lot line construction
S. Protected openings on walls < three feet from property line
III. Stairway Requirements
K
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railin or u ri hts that revent the assa a of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
NA/OK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
`
B. Masonry fireplace requires 2" clearance from all combustible materials
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of
the buildingwithin ten 10 feet horizontal
OK
V. Electrical Service Requirements
NA/OK
A. Electrical plan to include:Poke-
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
NA/OK
A. Pressure reducing -valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
NA/OK
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NA/OK
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
NA/OK
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Overhangs not allowed on zero lot line construction
20' triangle clear at corner
Required arkin
Street Ordinance Requirements
N
OK
Maximum drive width for residence is 28'
Minimum 30 feet from driveway to side(intersecting) street
r
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
Subdivision Regulations — Ordinance 690 NA/OK
Approved subdivision ov
Plat filed
Flood lain Regulations — Ordinance 1301 OK
Does not block any water course
Need elevation certificate
ZONING OFFICIAL
DATE
C� 5
PLANS EXAMINER IbATE