Loading...
HomeMy WebLinkAboutRES2003-01059PREPARED 10/02/03, 12:15:15 INSPECTION TICKET PAGE 6 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/02/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 5301 ST ANDREWS DR SUBDIV: PEBBLE CREEK CONTRACTOR BANDERA CUSTOM HOMES PHONE (979) 696-2545 OWNER PEBBLE CREEK DEVELOPMENT CO PHONE PARCEL 497900-0036-0010 APPL NUMBER: 03-00001059 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/28/03 TB BLDG, FOUNDATION -SLAB TIME: 13:00 4/29/03 AP 04/28/2003 08:25 AM SSTANLEY STRINGS ON SETBACKS OKAY - RIGHT SIDE 10' P.U.E. SLAB GROUND BACK RIGHT CORNER B115 01 6/13/03 TB BLDG, FRAMING TIME: 17:00 6/16/03 DP AFTERNOON PLEASE 06/11/2003 10:53 AM LLONG tighten anchor bolt nuts, missing all along left side of house top of fireplace needs to be firestopped fire block columnsto each side of entry need to block all OSB wind bracing joints B115 02 6/19/03 TB BLDG, FRAMING TIME: 17:00 6/19/03 AP 06/17/2003 02:56 PM LLONG B125 01 10/02/03 I BLDG, FINAL TIME: 17:00 ' 16 `2" D7 10/02/2003 10 : 09 AM SSTANLEY --------------------------------- COMMENTS AND NOTES -------------------------- / UL J Attorki (AV I v x�D�Jfr v 'A S41 CITY OF COLLEGE STATION WORK REQUEST PAGE 1 .rEO/JOB: WF0395635 / 001 PROJECT: REQUEST DATE: 4/29/PRINT 03 CREW: PRINT TIME: 9:45:47 SCHEDULE LOCATION: 5301 ST ANDREWS DR START:DATES 4/29/03 77845 COMPLETION: 4/29/03 GEN. LOC: COLLEGE STATION LOC ID: 192316 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: BANDERA CUSTOM HOMES 696-2545 ORIGIN: CUSTOMER -WALK IN USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE CITY OF COLLEGE STATION WOE- REQUEST PAGE 1 REQ/JOB: WF0391389 i 001 PROJECT: REQUEST DATE: 4/14/03 PRINT DATE: 4/14/03 CREW: PRINT TIME: 13:52:01 LOCATION: 5301 ST ANDREWS DR SCHEDULE STTART:DATES 4/14/03 77845 COMPLETION: 4/14/03 GEN. LOC: COLLEGE STATION LOC ID: 195432 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: Bandera Custom Homes ORIGIN: CUSTOMER -WALK IN USER ID: KELMENDORF AUTH: KELMENDORF WORK TYPE: ROUTINE 3/4" water 4" sewer 3/4" water 4" sewer Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE inspect fee that must be paid by Bandera Homes before the CO can be issued. Sincerely, Mandl Alford Customer Service Rep. Development Services City of College Station X Lome of Texas A&M University Home of the George Bush Presidelttial Library and Museum W03 MJVGNViS SQOW TO {S)39dd LT :00 :00 NOiivdna Z ZZ T0696 3WVN/ ' ON XV-3 91?:0T L0/0T 3WI1`31t7Q 6L0Tb6I'Z30a9 #'N3S 0L56b9LGL6 n31 96b6b9L6L6 Xv3 a3S 1N3WdO-13A3Q SOOO 3WaN 9ti:0T E00Z/L0/0T 3WI1 1�IOd3�1 NOI1VOI3Id3A NOISSIWSNVai The City of College Station, Texas Embracing the Past, Exploring the Future. P.O. Box 9960 1101 Texas Avenue 0 College Station, TX 77842 (979) 764-3500 www.ci.college-station.tx.us Tuesday, October 07, 2003 Re: CO for 5301 St. Andrews Dear Mr. Chris Kelly As of today there has not been a CO issued for the above address due to a $27.00 re- inspect fee that must be paid by Bandera Homes before the CO can be issued. Sincerely, Mandi Alford Customer Service Rep. Development Services City of College Station Home of Texas A&M University Home of the George Bush Presidential Library and Museum 0 A / 104:11' com- 4-0 sewer access 3g '4"f I �ro / 25' boil 1 X- ! I Qj I' 9 RE5IDENGE I I I - foundation outline Q ci 3131 sq. Ft. Iota I slab Area _ m f I I fi waI � I concrete drive 1 m 1 ' 25uilding line 1 \ � I � � I 9 C-21 - I I fight pole � � � I m i I box N ❑ sidewalk. 14'—'-----� st® Andrews [:)rl\/e ---- 5301 St. Andrews Dr. eIT FLAN 5G,4LE: 1" = 20' PEBBLEGREEK LOT: 1 5UE3DIVi51ON BLOCK: 3(o BANDERA FH,45E: 9A HO4 1E5 0 5' 10' 20' 40' SCALE: 1 "=20' REAR ELEVATION 8CALE: 1/4'.I'-V ELEVATIONS scale: 1/4" - 1'-0" NOTES: • builder to provide gas fireplace venting as per monufactuers requirements. • Roofing material to be composition sh"Ies unless otherwise noted. • Exterior material to be brick unless otherwise noted. • Roof pitch as noted Orouhgout FRONT ELEVATION WALE, V4'.I'-e' REVISIONS Wt. DATS: I j liL� R MMR RJR I I i i W ao � W L�- d+ _ C', t` U' try 0 � I , a c � I Kai dc,i.c�e 5701 ScF aLwff: SPECULATIVE RESIDENCE 6strnaaE: BANDERA CUSTOM HOMES %tncsrtaN: PEHHLBCREEE SUHDIViSION star 1 �acC_36 SEMON: 1 GCAt.E: F era: 09.02 � H.I.F. E-1 M 7 1 0 NOTES. L NEADE.R 1 E$ Mb ' (LKZM NOTED) 17'-1' CLGL' W-O' N'_I' MAW: %'-a' W-PCLG'O.'O'-O' .-r MAML,'-O' S'-P CLGa' •'-e' toes wbdo..d hallo) t. ALL ANSLEE ARE TO BE 48 DEGIEEO. & ALL OHOUN DOOM TO BE !TACT 1E6I8TANT IF3'71"P.AF.D GLAEE. 4. PIlONDC O/M' TYPE W fl WW SHEK714OCK BELOW OTAN A ON ALL WALL & APD OEILNS OF GARAGE OP ATTACNEDI, AND AT ALL NECEOOARr PURR PORNO. O. LOCATE WATER NEATER IN ATTIC PLACE N PAN WTTH IELEF TO CUTODE. i. CENTER ALL OP IN W IN WALLS WHEW NOT DM' BONED. ,. ALL 9 X ME" pDICATED APIE TO BE 1W9> MCI)' TYPE W/ 1R' PLYdJO= GLLED AND NAILED BEiW IN EACH PMT.CE. O. ALL CEILPIS JOIOTO TO BE h4 Llr M OTM1WSE NOTED. L ALL DOOM PMT !LOOM TO BE V-0' 1 WkdOW O.et �.}�� Wk1dOW ..al . 14' r • knee •T�u b45 SIN Ma6ter Bedroom 2 ® Bath Bedroom 3 m Q Tib p dy, 74' a•• 8'-4' W-8' 4' %'-4' Carpet FLaw � 8 2 v GaraGe O ® ® I I O O 9 9'.I- cis o r O'_8. up- il j0 8 Ivw cant n W � Y it r•s � � a F E �F� 7' It-M the Master Suite . • © Rear Utility Hall coffered cig. to II' eolld taro Carpel Flow 9 9 Title . 4, C © q ® R Tneig ® 9 dN .i -Pt. rra. 10 u0 D. M. L P. � 71 ®pocket ke. • • ; ow ee range $' 4' 19' 24'-4' and 2- S O E _4. ® it 4' c O _ !I, Illwl O ! N bar Kitchen IO'-1' Clg. RoioTR Breakfast Tib Qr ♦ Room -4, Ca -I FIS 3 it1 Tib � mI4oW. H _ in vi K C Porch Z2'-I' CIS. Ib fLoo OPavar. f� scat+ `� R6ar Tile no CIO t `S Porch 8 Pat CIS. to I7' n L A N m pper' Bedroom 4/ kv. Tile Study :r flu•Fi m Carpet FLU O Gfl Y -8..hes A iV it © raw•-d•• Y 2' arched niche - 6 eMlvae O-41 WINDOW SCHEDULE A, 7060 . T-O' hdr. 4 S~ a 114' hat'. G OWW .tdelne. a S. hdr. W 94 r. t abeve P. N" W JEGO arch a V-S' hdr. E. 16M .V wall Van. aah le 1L 49W a,'-S' hdr. L 2~ • T-e' hdr. J. 10,0 . ,'-O' hat'. K lOTO a O'-O' HIM L 4WW. V-0'MDR I v.rRiN�as tFiO _ p.r eaWf. IST LOOR PLAN •T •' SCALE, 1/4'.I'-C' I sz'-e' 1AREAS P"T FLOOR / 2,"4 OF. TOTAL LWM AREA GARAQB aA OF. PORCH OI op. REAR POR014 !T OF. TOTAL COVERED !AI OP. VODO No OF. I REVISIONS �Enit DAM U I 44"g�bbbQyaya y^��y� 1 p tMn �n I m cC II Q)CQ Cn C7 H :34 p�q CQ Cn I kpitit Sine ''.S+ AMv�rct,is CLEM: SPECULATIVE RESIDENCE �2974 avDnMa: BANDER& CUSTOM HOl[ES ,'TAICA710Ti: I PEBBLECRM SUBDIVMON T.vr 1 _ �s1.Dca. 971, 8- ..82CLTON: _ 1 eaerx iJ4' 1 0 11A7 09.02 li BLF. aaam.. :A-1� i.` _ OP:__y....: LEFT SIDE ELEVATION BGALr: 1/4••i'-e' ELEVATIONS scale. 1/4" - V-0" NOTES. • builder to provide gas fireplace venting as per monufactuers requirements. • Roofing material to be composition shingles unless otherwise noted. • Exterior material to be brick unless otherwise noted. • Roof pitch as noted O rouhgout RIGHT SIDE ELEVATION SCALE, 1/4'•I'•® REVISIONS I]nit. tiers: i i E2 Fig tw � 1 I I A r, r i r- I O Q; aaW� I � i I I R ICdc„« I �I .III CLn:NT: SPECULATIVR RESIDENCE !sxran>9t: I HANDMU CUSTOM ao�s I /LOCAI'lON: P �l SMrVMON _se I actuate i i tin _9 oz-- —2 OP: 7 I� i {IR°/GFI UI'AGFI� YV� �I i i I � tlll^/L�1� YVr I O F'RE-WIpE CLG. FAN CLG. FAN � I � it 1 � ro ua daa I p� 4 4 i�� 220 ' YImKaFI iI �m n$ a i /LL Y4 L1r I I I it w-,rwl a� � o LLP. YVr ttPKW MVY� ELEGTRIGAL PLAN I scales I/4" _ I'-0' ELEGtRfGAL LSCs�ND aancN T�@dW7 YYTG1 !QR-YM7 dY7W WRDt E�_. Tf�° MOltm TAtLt Fl�OIQGI® WRIo� A2. TIC OI�01lO PMLr l7�OtL+Gtl9 Iwa.I.,000F clrL� � alLw wrLrx rLaolr aurLux � nna a+Ler tv amisr e� c�ecrola 9r�®v sm vaLr amar GZILl1D L � REVISIONS � I Inc. neTs: Mill I �I I I < rty I ,5'30l � A4ews sz�aculwrlva R&4IDSNCS HANDERA � lip.. cumm fl IACATiON:. - PSHHIZCRSSK � BURDIVL9ION J i ,,, 86CIfOF: S o�TT: os.oz _ . �_= ILLIP� EL1 1 lit O FlR.4M[Wa NOTPO: I. ALL WWTSP C TO W 3M • Y' = LN. M OTM WS NOW 1 FPWVUX N' COX MY OW 01 000 UPA QL ID! MAC !. ALL F6PS, vAL1PY4 A!P wcon TO � oNe DNIs«ICYIAL sls>= LAAL&R THMi NT9�TNR wxielss fsXi � 7fIS IUIFIBN 1. OP4 ALL G %§ GORNWM 1'f6tR16 WRH 7Xf &IMCIIF6 AC' OO. Ql ALL 246 CVa 10.0 4 PI�CVIO! LEi RAAFFTSR TCJ ALL PLATES W6106 JOINTS R11 •- ALL WP VAl1R1VAU1dr NtAM RA-12 . PJILNR AND SPLICES OtG/NC6 N ANT Q TNR AOOVE MMLl pE ORS 047 W STRONSOORL OR WARIOIS O6LOILL DC MM OVM A AU MARNA L CAREENS TW SFNO 6W DRUJOSTO I'D AND NSTNLEO FVNNLLR. WTN ANY OF IS RAnNI ! JOSTS 6®DIY AIR 11NW1LL6. WiH TF61 GEAI'IS. RAFIRRR AlO }tiIR.00 AOOVE FRAMING NOTES: L ALL LY'EER 0".L OR STAMP® WRH TIM *RAM MARCOF AN APRW7YW TESTM6 AWCY s. IOW Comm TO No TUAXA-W'I MOIITL M Comm A FRAME OP@NNa OOLWA STUD FOR OPENNW LESS THAN W WDE AND MR" 6TND FOR OPENN36 4' OR OREATa! 4 PROVIDE A CONTIM70NS TIN ACROS6 BU LDNS W14 STY11"CIAOK! ON ALL JOIST SPANID OVER 1'-S' AND TWO STRONW5AOKS ON ALL JOIST SPANS OVER 1S'-W MN IONSDACKD SFw1 W ONE sXS MWiCAL AND ONE XX4 PLAT. RW PEII'FJ'DIGULAR TO JOISTS AND NAIL TO NACFF JOIST. S. pRACIN& PROVDE PLYWOOD SFEATFINS (TNIbO' M TO MATCH TYPICAL eon6Tlae "ATWINW AT MCA OF WW6 FIW TOP TO 00'T'TOM PLATES AT ALL COISEIWk 6. THE NY'OER OF 61411_ SUDS AT WAIWNC+ POINTS AT (DO ME'EER OEAV'1S SHALL EXCEED THE NN"ISER OF MB'1GC� IN TFE !!SM'L -L ALL STNWICTURAL L1MWR HAS MEN N DESIMED EASED ON SOUTFE71IN YELLOW PW OF T:E FOLL01IN6 MNIW ORA " APO Al' rM� a STRONGER AS PER NATIONAL FOWGT PRODUCTS A660CLATWK CAW C NdM IN 6PEOMO OR 6RAOM MUST 10 CQ'114911GATED ACOOWNRLY) STiD6 4 aR FJETTIOR 61EAMR / OMB 9 OR GETTER ALL 071-M Lain" 9 OR �El'IER S. HEADER &GilOILEa ALLDWAIN SPANS FOR 4 SYP HEADERS OVER Or"W" IN EXMMM 14' .. ,w AS FOL.Om WRAPW SIZE M4XMI!'1 SPAN NAOTH OF ROOF STRICTUIM 2-mas 4'-6' Lr TO si'-V 9-7X" Yi' 76' -o TO ss' r s-0)m r-0' s-sX&: W-0' 4-s)u's 61-W 24XM S'-W N m'S W-S' 11-M MADEISS AND SPANK AIM ABOU NS "CO LY 04WP MD LOAD REGUINg 4!W TO 10 THE NROh1 17lLTIPLED DY TI€ APPLICAN" LOAD. F (CONCRKtRATW) LOADS RWM DE" OR OPEN6dRS AOOVE ARE ATLIED TO TU M HEAMW SPECIAL ANALYSIS, A" BE R'O)AMD. a MICRO -LAM 8900 SIW-L USE AS MAHPACR6MD BY 'TRUST JOIST OR APPROVED 89JAL WITH TIE POLLOWIN6 PROPERm& I. W X NO•S PA F JMW STRESS - 2600 FW HORIZONTAL &FEAR FER'60'0ICILAR To"LINE . see PM FOLLOW &TRIG? MAMFACIUIW°:R GWDELNER FOR INSTALLATION AND DEMON PROVIDE MNIMM VElQTICAL STW EFdIWNS INDSW TFM IRS" AS 14SCa 'ETOED BY WE MA4 FAG"1N1M1! 10. PROVING DEAD MOOD AS NEEDED 11 SIM &FEET& 0-1. D-s AND 0-9 FOR ADDITIONAL NOTES REVISIONS DOTS:it ��JWL ��gy+�j[yyQ i iCOgm•C q ' 1 I QO � rn e9 z WC -+ C EM Lz+ CO - C7; a � I'I � l I R�3; dui. 5�, AM�•tws SnCUUTM RESIDENCE #2374 it N1DDD7m. I HANDERA CIISTOH HOMES PEHHLECRSSE 1 9IIHDIVISION i01-1---kncc.98_ IF ncrm: 1 6tai l/4 =1'-0 _J I E.LF. -:IR_�� PRO � OF: 7 IF-4' �oI D,DROP _ M m � ❑^ V 9 ;p 24'-4' a' -a. a = p xcrr � ;r 1• 'v , ast r -4 m 'a i elLa�nleae i� r -v 2' NOTE. TWIG DRAwm N No WAY REPTESBNTS AN E NSIMIM IID DENGN. IT IS PISOViDFD Aa A GUIDELNR FOR DIDDNG AM7 LAYOUT KNIFUSE6 ONLY. R a TE RESPAN6RILRY OF TFE DULL.DER TO CONaIR1 TE AC%AL DRAM PSN" AS NDICATED. SIC: L SIlY/UDE. L ALL VEGETATION $HALL DE FAMVED AV THE TOP SIX (&) NC E6 CP TOPSOIL STRIPTfD PW THE AREAIII, COVERED DY THE MWATGl 2.IN INDEO AID AROUND THE POINDATI)N SMALL DE A SANDY CLAY HAVNG A MNR'Mt PLASTICITY NOEX (P) PLOW OF 6 TO D AND SHALL DE FREE FROM TNASM. ORGANIC MATTER OR OTHER FOREIGN DEDRS MLL SHALL DE PLACED N SIX NCH LFTS, WTN EACH LPT UEITED OR PR ED7 TO A MOISTLI E CONTENT 'Ati MOVE THE OPTf V7 1'1010TIM CONTENT AND COMPACTED TO A UNFORT DENSITY OF MU OF THE MAXRMT DENSITY AS DETRRTNED MY ASTM D -MI. 1 FOINDATION WATER"RDO M ME IMAlE SMALL DE OVERILAP PED EMT A MNII w OF MOD (2) MET, SEALED ALONG TOP JONT6 AND DE A MNR " TWQCESS OF • MILLRRETFAS. L ALL CONCRETE SMALL DE PNE (S) BACK MDT WITH A MNR2Y1 COPIPIESSVE STM NSTH OF SA" PIN AT 20 DAYS. 2. ALL CONCRETE SHALL COWAN A WATER 118MOXM AGENT EQIAL TO MASTER WILDE" FGSSDITN SHN, TMEE OINCCS PER SAGO OF C9'BNT. !. ALL CONCRETE SMALL COWAN AIR OiTRANINS AGEW EOIAL TO MMM AND COMPATEJL.E WITH T4E WATER REDUCM6 AGONY, N TE OUANITIY NFAMMIED TO PRODUCE A 4 TO SA AIR BNiRAN111W. 4. ALL C 4OWM SMALL ESE PROPERLY VICRATED WEN PLACED. III RERFORCNG 6TL4•L., L ALL RENFOR M STEEL. SHALL DE DH'OR'ED ]BILLED STEEL DABS HAVNG A MINPMI YIELD WN97427H OF NOT LES6 TAW 49P P= COPF01lTN6 TO AS- A-&D, GRADE 4911. 2. ALL REWORCN6 STEEL SHALL OE FORM I'RR9 RAT OR OTMER ]BOND !EDUCING AGENTIL 3. ALL. LAPS MOCKS. DAMPS, SPLICES, AND OTERS N THE RENT OMM STEEL SMALL 000OR'1 TO COIN STANDARD& AND TE ACI CODE, LATEST RDRIOK 4. ]BOTTOM DARE, N THE GRADE REAM, MAY DE SPLICED N THE H US ONE TMIR7 OF TE SPAN D nLm POOTN56 OR AT NTmeecrm DE.AM6. SPLICE SAW. NAVE A MNRM( TWO (2) FOOT OVERLAP. &. TOP DARE, N TE GRADE OP.APL MAY BE SPLIGHP AT THE COMMNE OP THB —NG, OR AT MERSECTINS DETML SPLICE SMALL NAVE A MN"JM TWD (2) FOOT OVERLAP. &. ALL S'UCRS N PClIDATION MATT SMALL DE STAGGERED .MID HAVE A MNKII'T ONE (V T. CQIGETE COVERAGE FOR THE IEMaORCM SHALL CG49_Y WITH ACI CODE, LATEST EDITION. TIME DRAM STREL SHALL HAVE A M "J'I CLEARANCE UTH THE SOIL OF 74M ff) NOES AM THE FOUbATION MATT A MNRTUY OF ONE AND A HALF fl V NCHES WTH TE VAPOR DARKER. S. WERE PLN'ONG PO ETRAT S THROLI&H THE GLAD. PROVIDE DIAGONAL REINFORCING A MM THESE OP19046. DIAGONAL STEEL SMALL DE9 SAM AT ]&' LOWIAS PLACED AT THEE f7) NCNEG AWAY MILT'( THE PENETRATNG GSJECT. IV. G0L1W. MOM& L THE CONCRETE PC&DATION fSAD ON -GRADE) AS SHWN WAS 0E606D WTNOIJT THE USE OF A GROTECFEOCAL NVESTIGAT1ON MIT WAD DESIGNED ON TE SAM OF 0PANSIVE CLAYS TYPICAL TO THa REGIGd EVEN WITI TE P1ECAVTICN6 OF UOM A SELECT FILL AND PROPER COPpACT10N OF SSIGRADE. R a POSSOLE TWAT TINE GLAD MAY DR'ERENCE A CEITAN AMMNT CP MOVItIN T AND TE ACCOMPANYM DULLDNG OaTRRSSRb DUE TO THE EXPANOW SU"PORTM SOILS, 2. ALL SITE WORD AND GRAPHS SMALL DE SHOM ON THE ARC34ITECT16 OI E PLAK & WER TO CO &TOLICTIO N DETAIL S$T FOR POUWATION DETAILS. REVISIONS Tall DATE. I I I llit G��V i1 I bD g C�\2 � C"7 I � � C CQ / K, tl7 Cf.1HNT: SPECUUTIVE RESIDENCE �2974 DUIIDEL: ELMMA CUSTOM � H01IB8 � PEssisCRM SUHMSION j I scam 14 =1'-0 -- an ----. ----09---.02----- I D1df11TN: mm; F-1 ..... - - OF: 7 5 1/2#3 BARS O 12' O.C.E.W. SLOPE TO DRAIN Z N f� To 1 2 - }5 BAITS TOP k BOTTOM n L; 43 STIRRUPS O 24' O.C. POLY. VAPOR BARRIER (5 MIL) 3"� 14• TYPICAL EXTERIOR EXTERIOR_ GRADE BEAM 3/4' - 1--0' 3 BARS O 12' O.C.E.W. 1 POLY. VAPOR BARRIER (5 MIL) N O 2 - f8 BARS TOP k BOTTOM #3 STIRRUPS O 24" O.C. 3' CLEAR 12' TYPICAL INTERIOR GRADE BEAM 3/4' . low DWELLING FLOOR /3 BARS O 12' O.C.E.W. GARAGE OR PORCH 4 GARAGE FLOOR o SLOPE TO DRAIN 5 1�. 1 0 a _I_ 13 BARS O 12' O.C.E.W. tr •v o = yPOLY. VAPOR y T of + BARRIER (5 MIL) 0 0 2 - /5 BARS TOP k BOTTOM 'D n 2 - j5 BARS TOP k BOTTOM ry n /3 STIRRUPS O 24' 0.C. +,' +. L ..:: ' � •'.. #3 STIRRUPS O 24' O.C. \ 3' POLY. VAPOR BARRIER (5 MIL) CLEAR 12' . 3' CLEAR 14• EXTERIOR GRADE BEAM AT RECESSED GARAGE INTERIOR GRADE BEAM ALONG RECESSED AREA 3/4' _ 1,-0• 3/4' - V-O' 5 1/2' 4 N SLOPE TO DRAIN iv GARAGE FLOOR GARAGE FLOOR 1O #3 BARS O 12' O.C.E.W. 24' /5 DOWELO T4' O.C. o o i DRIVEWAY /3 BARS O 12. O.C.E.W. Y SLOPE TO GRAIN w 01 2 - #5 BARS (TOP) •.r ,.,=F .�,f� .i t i'• 2 - /5 BARS TOP & BOTTOM n .• : -'� 0 2 - 18 BARS TOP 6 BOTTOM 0 +3 STIRRUPS O 48' O.C. inn /3 STIRRUPS O 24' D.C. o 03 STIRRUPS O 24. 0.C. \ L.r.••. • • •`. POLY. VAPOR BARRIER (5 MIL) \ CLEAR 14' 3' POLY. VAPOR BARRIER (5 MIL) CLEAR 14• EXTERIOR GRADE BEAM AT RECESSED GARAGE (EXTRA DEPTH) EXTERIOR GRADE BEAM AT GARAGE 3/4' . 1•-0' 3/4' - 1'-0' EREMVISIONS II 7- itts�dc�c�. Hare: 09.02 j Linda Long - Insulation request inspection result, 5301 Saint Andrews, #03-1059 Page 1 From: Brian Henry To: Long, Linda Date: 6/20/03 9:14AM Subject: Insulation request inspection result, 5301 Saint Andrews, #03-1059 Print for File Inspected insulation, 5301 Saint Andrews, #03-1059, Bandera Homes, 6-20-03 Inspection result: Inspected OK for Good Cents Notes: Seal foam sheathing around the fireplace flue. Tape all sheathing joints, several need to be taped on back of house. CC: Stanley, Susan BU,"DING PZWT � C-I TY. OF— CSJLJZa&:, U.T I ' W 1101 TEXAS AVE r COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00001059 Date 4/14/03 Property Address . . . . . . 5301 ST ANDREWS DR Property ID . . 497900-0036-0010 R # . . . . . . . . . . . . . R112699 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . PEBBLE CREEK Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 205326 Owner Contractor ------------------------ ------------------------ PEBBLE CREEK DEVELOPMENT CO BANDERA CUSTOM HOMES %YOUNG BROTHERS BRUCE W MARTIN PO BOX 1800 7607 EASTMARK DR SUITE 100 WACO TX 767031800 COLLEGE STATION TX 77840 (979) 696 -2 545 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2374.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KE Permit Fee . . . . 778.00 Plan Check Fee .00 Issue Date . . . . 4/14/03 Valuation . . . . 205326 Expiration Date . . 10/11/03 Qty Unit Charge Per Extension BASE FEE 460.00 106.00 3.0000 THOU BLDG, VAL 100001-500000 318.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT ---------------------------------- ----- ------------ ---- -- --- BUILDING DEPT REPRESENTATIVE: 'i, APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00001059 Date 4/14/03 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES Windows in family room and possible breakfast rm. need to temper glass. Due to size, greater than 9 square feet, less than 18" above floor, etc. ----------------------------------------------------------------------------' Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number ---------------------------------------------------------------------------- . . . . . 03-00001059 Date 4/14/03 Other Fees . . . . . . . . . WATER TAP 3/4" CITY INSTL 400.00 Fee summary ----------------- Charged Paid Credited Due Permit Fee Total ---------- 778.00 -------------------- 778.00 ---------- .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1528.00 1528.00 .00 .00 --------------------------- ----- ---------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATIOP 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: ---------------------------------------------------------------------------- (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00001060 Date 4/14/03 Property Address . . . . . . 5301 ST ANDREWS DR Property ID . . . . . . . . . 497900-0036-0010 Application description . . . TEMP POLE Subdivision Name . . . . . . PEBBLE CREEK Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ PEBBLE CREEK DEVELOPMENT CO BANDERA CUSTOM HOMES %YOUNG BROTHERS BRUCE W MARTIN PO BOX 1800 7607 EASTMARK DR SUITE 100 WACO TX 767031800 COLLEGE STATION TX 77840 (979) 696 -2 545 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KE Permit Fee . . . . 20.00 Issue Date . . . . 4/14/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary ----------------- Charged Paid Credited Due Permit Fee Total ---------------------------------------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 -------------------------- --- - --------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00001059 Date 4/14/03 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES Windows in family room and possible breakfast rm. need to temper glass. Due to size, greater than 9 square feet, less than 18" above floor, etc. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 BUILDING DEPT REPRESENTATIVE: APPLICANT: Fa oTce use awy APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEG E-STATION.TX. U S DATE: APPLICATION#Dy�3, TEMP POLE # v �" I D by ADDRESS/LOCATION: 53011 Sw.,+ 44' ps V"'Vt. Qf QA LOT I BLOCK SUBDIVISION P66ciff 4C BUSINESS/OWNER NAME: Ct.3A. i6*yS PHONE: c0i. 04. ZS 1� CONTRACTOR/HOMEOWNER: Qrute kill. Ac....��.w PHONE: C119_ 4f 2. s?81 CONTRACTOR ADDRESS: 160-1 Ef;4u,,1L (D,;r[ i4q, CSt,T-Y 778go ELECTRICIAN: �G T,�lt �'«.-k L PLUMBER: 1Uw6inG '� HVAC: C kw•p ; C i<t�r: L GOOD CENTS (Residential only): LDS /A st.&,4, CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL DESCRIPTION OF WORK: (4 Bel u,w• . 2 t(-2 ga-fk . 2 lkgo, C,.ec c_e STRUCTURE USE: �' ( _ S HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW E APPROVAL: c ,� TEXAS ACCESSIBILITY STANDARa" PROJECT REGISTRATION# EABPRJ VALUATION: $ I R $� TOTAL AREA: &! 11 HEATED AREA: 2131 ( aoM�terials) vo PUBLIC SEWER j� NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM SEWER TAP: 3S�j 7 WATER TAP: / SIZE OTHER TAP: IS TEMP POLE GARAGE TYPE SIZE SINGLE EJ ATTACHED Si SIGNATURE OF APPLICANT: NUMBER OF BATHROOMS: INTERIOR WALL TYPE EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE DETACHED I —I Z t/Z TRIPLE a CARPORT a Zxy Official Use Only Comments: YES or NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls F-13 Insulation R value of ceiling 1 (flat areas) R. 30 Insulation R value of ceiling 2 (vaulted areas/no attic) A 19 Glazing SHGC 0 - q O Glazing U-Factor 0 .35 R value of ductwork RC A/C SEER rating 12 REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release 1 Data filename: C:\Documents\necchecks\B-2425.rck TITLE: Spec-2425 S 3o( -T Ar%AeCjv s b r 4 ve- CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 04/ 10/03 DATE OF PLANS: 04-09-03 COMPANY INFORMATION: Bandera Custom Homes 1707 Eastmark Dr. College Station, TX 77840 (979)696-2545 NOTES: This REScheck report was generated by R.A.I.: John Rhodes P.O. Box 9389 College Station, Texas 77845 (979)412-5066 COMPLIANCE: Passes Maximum UA = 799 Your Home UA = 571 28.5% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Vinyl Frame:Double Pane with Low-E SHGC: 0.40 Door 1: Solid Floor 1: Slab-On-Grade:Unheated Insulation depth: 0.0' Furnace 1: Forced Hot Air, 80 AFUE Air Conditioner 1: Electric Central Air, 12 SEER 03-M59 Permit Number Checked By/Date G 142./ O� Aica ' (4 TO Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 337 30.0 0.0 12 2350 13.0 0.0 157 337 0.350 118 96 0.440 42 232 0.0 242 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release 1 (formerly MECchecl and to comply with the mandatory requirements listed in the REScheckInspection C4eckjist. Builder/Designer�u' ��"� Date 4-- REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.5 Release 1 DATE: 04/ 10/03 TITLE: Spec-2425 Bldg. Dept. Use I Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above -Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: 1. Window 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 1: Solid, U-factor: 0.440 Comments: Floors: 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: 1. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number 2. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number Solar Heat Gain Coefficient: The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. Cooling ducts with exterior insulation must be covered with a vapor retarder. Air filters are required in the return air system. The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 T must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to V Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVACPipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Area Calculator: IM��MMIMIMMMMM Description �� , ., - .. off■ . , ■ : „ , : „ ©�� Window Area Total: 336.66 04/09/03 14:08:50 1 /1 Area Calculator: 1��VIOIOI Comments/ Door Area Total: 96.00 04/09/03 14:08:55 1 /1 Area Calculator: M Assembly Type Comments/Description Ceiling Area Total: 2468.00 04/09/03 14:08:58 1 /1 Area Calculator: Assembly Type Length x Height = Gross Area Comments/Description 1 Wood Frame, 16" o.c. 32'-10" 11'-6" 377.58 ft2 2 Wood Frame, 16" o.c. 20'-4" 10'-11, 205.03 ft2 3 Wood Frame, 16" o.c. 56'-10" 11'-01, 625.17 ft2 4 Wood Frame, 16" o.c. 60'-2" 9'-11, 546.51 ft2 5 lWood Frame, 16" o.c. 16'-8" 9'-11, 151.39 ft2 6 Wood Frame, 16" o.c. T-0" 12'-1" 84.58 ft2 7 Wood Frame, 16" o.c. 35'-8" 10'-11, 359.64 ft2 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Exterior Wall Area Total: 2349.90 04/09/0314:08:59 1 /1 Area Calculator: Assembly Type Comments/Description M.7ifingerim.■�■ Floor Area Total: 0.00 04/09/03 14:08:59 1 /1