Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2003-01046
City of College Station k 1101 TEXAS AVENUE' COLLEGE STATfON'TX 77840 C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . . . Owner . . . . . . . . . Contractor . . . . . . Application number Description of Work Construction type . . . Occupancy type . . . . Flood Zone . . . . . . Approved . . . . . . . 7/23/03 569500-0728-0890 1214 ROANOKE CT COLLEGE STATION TX 77845 SHENANDOAH PH 7 SHENANDOAH 47-B, BLOCK 28, LOT 89 UNKNOWN FROEHLING, EDWARD ED FROEHLING BUILDERS 979 776-8266 03-00001046 000 000 RESIDENTIAL, 1 UNIT DETACHED NEW COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX , Building Official VOID UNLESS SIGNED BY BUILDING OFFICIAL PREPARED 7/22/03, 12:06:43 INSPECTION TICKET PAGE 34 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/22/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 1214 ROANOKE CT SUBDIV: SHENANDOAH PH 7 TENANT, NBR: SFR-SHENANDOAH 7B CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER FROEHLING, EDWARD PHONE PARCEL 569500-0728-0890 APPL NUMBER: 03-00001046 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 5/02/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00 5/05/03 AP 05/01/2003 01:02 PM SSTANLEY SETBACKS PER STRINGS SLAB GROUND AT LEFT BACK CORNER B115 01 5/29/03 CH BLDG, FRAMING TIME: 17:00 6/10/03 AP 05/29/2003 11:00 AM KELMENDORF B130 01 6/18/03 CH BLDG, INSULATION TIME: 17:00 6/18/03 AP 06/17/2003 03:40 PM KELMENDORF B125 01 7 22/03 BI BLDG, FINAL TIME: 17:00 1 07/22/2003 09:02 AM KELMENDORF \�l' -------------------------------------- COMMENTS AND NOTES -------------------------------------- fir' �° I" Y'I5 JeAM BUILDiNG PERMIT `,- CITY OF COLLEGE STATI rr!x" AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00001046 Date 4/11/03 Property Address . . . . . . 1214 ROANOKE CT Property ID . . 569500-0728-0890 R # . . . . . . . . . . . . . R112807 Tenant nbr, name . . . . . . SFR-SHENANDOAH 7B Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SHENANDOAH PH 7 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 122430 Owner ------------------------ Contractor FROEHLING, EDWARD ------------------------ ED FROEHLING BUILDERS 3887 HIGH LONESOME ED FROEHLING COLLEGE STATION TX 778459443 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 HEATED AREA 1855.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 ---------------------------------------------------------------------------- SEWER TYPE PUBLIC Permit . . . . . . BUILDING PERMIT Additional desc . . LL Permit Fee . . . . 529.00 Plan Check Fee .00 Issue Date . . . . 4/11/03 Valuation . . . . 122430 Expiration Date . . 10/08/03 Qty Unit Charge Per Extension BASE FEE 460.00 23.00 3.0000 ---------------------------------------------------------------------------- THOU BLDG, VAL 100001-500000 69.00 Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) , PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT BUILDING DEPT REPRESENTATIVE: 1UILDING PERMil CITY OF COLLEGE STATI 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00001046 Date 4/11/03 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE Provide hearth in front of fireplace ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited Due --------------------------- ------------------------------ Permit Fee Total 529.00 529.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1279.00 1279.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: �(^ i bUiLD.ING PERMiT CITY OF COLLEGE STATI 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 Application Number . . . . . 03-00001046 BUILDING DEPT REPRESENTATIVE: APPLICANT: Page 3 Date 4/11/03 CITY OF COLLEGE STATION WO1 .EQUEST PAGE 1 REQ/JOB: WF0391643 / 001 PROJECT: REQUEST DATE: 4/15/03 PRINT DATE: 4/15/03 CREW: PRINT TIME: 10:35:24 SCHEDULE DATES LOCATION: 1214 ROANOKE CT 77845 COMPLETION: 4%15%03 GEN. LOC: COLLEGE STATION LOC ID: 195272 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ED FROEHLING ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 3/4" WATER 4" SEWER 3/4" WATER 4" SEWER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US Fa OKKe Um Only DATE: !f1V=.3 APPLICATION # 0 IN `i (0 TEMP POLE # ADDRESS/LOCATION: e: 000a-7- LOT A92 BLOCK Z0 SUBDIVISION BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: 97D 1FP-0rJ+L1424 I tPILDbg-.I.o PHONE: 776 f3266 CONTRACTOR ADDRESS: S99, 7 4-0 Vx Sp/I ELECTRICIAN: 1t$ LAC 7,e,t c _ PLUMBER: ]!�9/ Pt-e " > . 1P1-0r/8&) HVAC: S G ).i>.uj!�)yArj V SE.rZ V[c.f 5 GOOD CENTS (Residential only): i(1 CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL DESCRIPTION OF WORK: STRUCTURE USE: 4t,041 e F4/7/ c-y HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: /1/,/_ TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ Q VALUATION: $ i Z Z.4.3o TOTAL AREA: Z 8 HEATED AREA: (Cost of Labor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM E SEWER TAP: P3_WATER TAP: -1 i1 SIZE 3of SIZE OTHER TAP: SIZE TEMP POLE GARAGE TYPE: SINGLE a NUMBER OF BATHROOMS: Z_ INTERIOR WALL TYPE EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE TRIPLE su6r--r?-©6k a 21e-1< M. ATTACHED DETACHED a CARPORT SIGNATURE OF APPLICANT: Official Use Only C ments: Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling I (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating 10 s5a- REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: C:\Program Files\Check\MECcheck\131 IRK.cck TITLE: 1311 ROANOKE COURT CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 04/09/03 DATE OF PLANS: DECEMBER 13, 2002 PROJECT INFORMATION: TRAN HOME COMPANY INFORMATION: ED FROEHLING BUILDER, INC COMPLIANCE: Passes Maximum UA = 558 Your Home UA = 535 4.1 % Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.34 Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame, Double Pane with Low-E SHGC: 0.40 Bldg. faces 315 deg. from North; Comp. orient.: Front Projection factor: 0.23 Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 315 deg. from North; Comp. orient.: Left Side Projection factor: 0.23 Wall 3: Wood Frame, 16" o.c. Window 3: Metal Frame:Double Pane with Low-E SHGC: 0.40 ' Bldg. faces 315 deg. from North; Comp. orient.: Back Projection factor: 1.15 Door 2: Glass Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1855 30.0 0.0 65 369 13.0 0.0 21 73 0.640 47 38 343 13.0 0.0 47 369 13.0 0.0 64 71 0.400 15 24 0.640 30 19 0.640 41 0.580 41 SHGC: 0.78 Bldg. faces 315 deg. from North; Comp. orient.: Back Projection factor: 1.00 Wall 4: Wood Frame, 16" o.c. 343 13.0 0.0 27 Window 4: Metal Frame:Double Pane with Low-E 18 0.640 12 SHGC: 0.40 Bldg. faces 315 deg. from North; Comp. orient.: Right Side Projection factor: 0.23 Floor 1: Unheated 185 0.0 193 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 10 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release lb (formerly MECchecl and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer "L,- Date Rpr 08 03 03:36p Michael McClure 979 693-2SS4 P.3 Back of Curb 5' P.U. Roanoke Court 50'R.aw — 27'Pawmwt Vol 4W71, Pg. 158 65000 7. T 49.5' 7.9 Scale; 1 20' Proposed Residence Lot ae NOW *' Formeriy Edward Froehfin Lot 84, Block 28 Lot 90 Now or Fortnerly lt Fmohling Edw2988 Voi. 2966. Pg. Shenandboh Phow 7-8 Vol. 2980, Pg. 201 49.5' 75' Note; 8W9. Setback Linea W City of College StWon Zoning Ordinome JI&M L L Cq 10' P.U.E. Vol. 4054, Pg. 155 4526.0- " W - 6* Sklewolk Back of Curb Southem Plantation Dtive 6o' R.aw. - -V' Pave~t 01 —89b2IIdwg YK 467f, Pg. 758 , 0,_11opq INC AMP Wboa�-,-wwa-lm, Salte W