Loading...
HomeMy WebLinkAboutRES2003-01041City of College Station 1101 TEXAS AVENUE COLLEGE ' STATION TX 7'7I40 .✓ C E R T I F I C A T E O F O C C U P A N C Y P E R M A N E N T Issue Date . . . . . . Parcel Number . . . . . Property Address . . . Subdivision Name . . . Legal Description . . . Property Zoning . . Owner . . . . . . . Contractor . . . . . . 7/23/03 650730-0101-0170 1045 WINDMEADOWS DR COLLEGE STATION TX 77845 WESTFIELD VILLAGE PH 1 WESTFIELD VILLAGE #1, BLOCK 1, LOT 17 UNKNOWN BCS DEVELOPMENT CO STYLECRAFT BUILDERS 979 690-1222 Application number 03-00001041 000 000 Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW Construction type . . . COMBUSTIBLE (UNPROTECTED) Occupancy type . . . . RESIDENTIAL -MULTI -FAMILY Flood Zone . . . . . . Approved . . . . . . . Building Official VOID UNLESS SIGNED BY BUILDING OFFICIAL PREPARED 7/21/03, 12:14:15 INSPECTION TICKET PAGE 12 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/21/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 1045 WINDMEADOWS DR SUBDIV: WESTFIELD VILLAGE PH 1 TENANT, NBR: STYLECRAFT CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER BCS DEVELOPMENT CO PHONE PARCEL 650730-0101-0170 APPL NUMBER: 03-00001041 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 4/21/03 OC BLDG, FOUNDATION -SLAB TIME: 13:00 4/22/03 AP 04/21/2003 09:11 AM SSTANLEY SETBACKS PER STRINGS SLAB GROUND AT LEFT BACK B115 01 5/21/03 CH BLDG, FRAMING TIME: 17:00 5/22/03 AP 05/21/2003 09:15 AM LLONG B130 01 5/27/03 CH BLDG, INSULATION TIME: 17:00 5/27/03 AP 05/23/2003 10:26 AM MRODGERS B125 01 742/03 BI p BLDG, FINAL TIME: 17:00 6.3 C 07/21/2003 11:11 AM SSTANLEY okay ---------------- COMMENTS AND NOTES--------------------- c, LAwo IY'oja %oi\ Sy'_Azm QITz OF COLLEGE STATION - WORK REQUEST PAGE 1 REQ/JOB: WF0392382 / 001 PROJECT: REQUEST DATE: 4/17/03 PRINT DATE: 4/17/03 CREW: PRINT TIME: 13:59:43 SCHEDULE LOCATION: 1045 WINDMEADOWS DR START:DATES 4/17/03 77845 COMPLETION: 4/17/03 GEN. LOC: COLLEGE STATION LOC ID: 195774 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BLDRS (690-1222) ORIGIN: CUSTOMER -WALK IN USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE TEMP POLE PASSED ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- ..�..,�. -... _..BU.TLD I NG . PERM I.T ,� CITY QF. CIQLLEGE ,STAT, ; 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00001041 Date 4/11/03 Property Address . . . . . . 1045 WINDMEADOWS DR Property ID . . 650730-0101-0170 R # . . . . . . . . . . . . . R113298 Tenant nbr, name . . . . . . STYLECRAFT Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD VILLAGE PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 81312 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4060 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL -MULTI -FAMILY Other struct info . . . . . EXTERIOR WALL TYPE HARDIE STONE IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1232.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . LL Permit Fee . . . . 388.00 Plan Check Fee .00 Issue Date . . . . 4/11/03 Valuation . . . . 81312 Expiration Date . . 10/08/03 Qty Unit Charge Per Extension BASE FEE 260.00 32.00 4.0000 THOU BLDG, VAL 50001-100000 128.00 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT , PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE i BUILDING DEPT REPRESENTATIVE: APPLICANT: ��� BUILDING PERMIT CITY OF COLLEGE STATI 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00001041 Date 4/11/03 ---------------------------------------------------------------------------- Special Notes and Comments ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 388.00 388.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 ------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATI 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00001041 Grand Total 1138.00 1138.00 Page 3 Date 4/11/03 .00 .00 ------------------------------------------- BUILDING DEP`T REPRESENTATIVE:�-f ------------------ APPLICANT: /! TEMPORARY POLE PERMIT ` CITY OF COLLEGE STATI 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00001042 Date 4/11/03 Property Address . . . . . . 1045 WINDMEADOWS DR Property ID . . 650730-0101-0170 R # . . . . . . . . . . . . . R113298 Application description . . . TEMP POLE Subdivision Name . . . . . . WESTFIELD VILLAGE PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ BCS DEVELOPMENT CO STYLECRAFT BUILDERS 4090 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4060 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . LL Permit Fee . . . . 20.00 Issue Date . . . . 4/11/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary ----------------- Permit Fee Total Other Fee Total Grand Total Charged Paid -------------------- 20.00 20.00 45.00 45.00 65.00 65.00 BUILDING DEPT REPRESENTATIVE: APPLICANT: Credited Due -------------------- .00 .00 .00 .00 .00 .00 CITY OF COLLEGE STATION WO1 zEQUEST PAGE 1 REQ/JOB: WF0391642 / 001 PROJECT: REQUEST DATE: 4/15/PRINT 03 CREW: PRINT TIME: 10:32:41 LOCATION: 1045 WINDMEADOWS DR SCHEDULE STTART:DATES 4/15/03 77845 COMPLETION: 4/15/03 GEN. LOC: COLLEGE STATION LOC ID: 195774 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 3/4" WATER 4" SEWER ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 3/4" WATER 4" SEWER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION: O W in d in ea dt w S% V V LOT � BLOCK - SUBDIVISION elf- P 1 Pi d L/I l BUSINESS/OWNER NAME: p For Office Use Only DATE: ` + APPLICATION 1` +` TEMP POLE # PHONE: PHASE / CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: College Station Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Single Familv Residence HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS VALUATION: ACCESSIBILITY STANDARD (T0 )SRO, TOTAL AREA: i�JHEATED AREA: i @t3a (Cost` and Materials) P/ FX PUBLIC SEWER 3v U NUMBER OF BEDROOMS: ❑ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: QX SEWER TAP: 4" INTERIOR WALL TYPE: Sheet Rock J1Lc �X WATER TAP: 3/a" EXTERIOR WALL TYPE: SIZE OTHER TAP: FOUNDATION TYPE: SIZE �X TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE DOUBLE XTRIPLE ATTACHED DETACHED F__] CARPORT A n. SIGNATURE OF APPLICANT: Plans Examiner Official Use Only Zoning Official I Slab on Grade Composition C nts: ES r NO 'zl d Energy Code Compliance Information % Glazing of exterior walls 10 % Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40 Glazing U-Factor .65 R value of ductwork R6 A/C SEER rating 12 REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release 1 Data filename: S:\ACAD\MECcheck\1238-1232-1066 Windmeadows.cck TITLE: Plan # 1238-1232 Front Porch CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 04/09/03 DATE OF PLANS: 04-09-03 PROJECT INFORMATION: SPEC 1045 Windmeadows College Station, Texas COMPANY INFORMATION: Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 COMPLIANCE: Passes Maximum UA = 522 Your Home UA = 435 16.7% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 D�'/ Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 900 30.0 0.0 32 Ceiling 2: Cathedral Ceiling (no attic) 332 19.0 0.0 17 Wall 1: Wood Frame, 16" o.c. 1283 13.0 0.0 90 Window 1: Metal Frame, Double Pane with Low-E 127 0.670 85 SHGC: 0.40 Door 1: Solid 38 0.500 19 Door 2: Glass 18 0.440 8 SHGC: 0.40 Floor 3: Slab-On-Grade:Unheated 177 0.0 184 Insulation depth: 0.0' Air Conditioner 2: Electric Central Air, 11 SEER Furnace 2: Forced Hot Air, 80 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release I (formerly MECchecl and to comply with the mandatory requirements listed in the REScheckInspection Checklist. Builder/Designer Date REScheck Inspection Checklist 2000 IECC RES check Software Version 3.5 Release 1 DATE: 04/09/03 TITLE: Plan # 1238-1232 Front Porch Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: [ ] 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.670 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] 1. Door 1: Solid, U-factor: 0.500 Comments: [ ] 2. Door 2: Glass, U-factor: 0.440 Comments: Floors: [ ] 1. Floor 3: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: 1. Air Conditioner 2: Electric Central Air, 11 SEER or higher Make and Model Number 2. Furnace 2: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Area Calculator: Description imp ��■�■����� Window Area Total: 126.65 04/09/03 14:14:50 1 /1 Area Calculator: I= Assembly Type Description OM2 -Garage Door Area Total: 55.56 04/09/03 14:14:51 1 /1 Area Calculator: Assembly Type Comments/Description Ceiling Area Total: 1232.00 04/09/03 14:14:51 1 /1 Area Calculator: AssemblyType Comments/Description m■�■�� m■�■�� Exterior Wall Area Total: 1282.67 04/09/03 14:14:52 1 /1 Area Calculator: Assembly Comments/Description Unheated ..■�■ Floor Area Total: 0.00 04/09/03 14:14:54 1 /1