HomeMy WebLinkAboutRES2003-01041City of College Station
1101 TEXAS AVENUE
COLLEGE ' STATION TX 7'7I40 .✓
C E R T I F I C A T E O F O C C U P A N C Y
P E R M A N E N T
Issue Date . . . . . .
Parcel Number . . . . .
Property Address . . .
Subdivision Name . . .
Legal Description . . .
Property Zoning . .
Owner . . . . . . .
Contractor . . . . . .
7/23/03
650730-0101-0170
1045 WINDMEADOWS DR
COLLEGE STATION TX 77845
WESTFIELD VILLAGE PH 1
WESTFIELD VILLAGE #1, BLOCK 1,
LOT 17
UNKNOWN
BCS DEVELOPMENT CO
STYLECRAFT BUILDERS
979 690-1222
Application number 03-00001041 000 000
Description of Work RESIDENTIAL, 1 UNIT DETACHED NEW
Construction type . . . COMBUSTIBLE (UNPROTECTED)
Occupancy type . . . . RESIDENTIAL -MULTI -FAMILY
Flood Zone . . . . . .
Approved . . . . . . .
Building Official
VOID UNLESS SIGNED BY BUILDING OFFICIAL
PREPARED 7/21/03, 12:14:15 INSPECTION TICKET PAGE 12
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/21/03
------------------------------------------------------------------------------------------------
ADDRESS . : 1045 WINDMEADOWS DR SUBDIV: WESTFIELD VILLAGE PH 1
TENANT, NBR: STYLECRAFT
CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222
OWNER BCS DEVELOPMENT CO PHONE
PARCEL 650730-0101-0170
APPL NUMBER: 03-00001041 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/21/03 OC BLDG, FOUNDATION -SLAB TIME: 13:00
4/22/03 AP 04/21/2003 09:11 AM SSTANLEY
SETBACKS PER STRINGS
SLAB GROUND AT LEFT BACK
B115 01 5/21/03 CH BLDG, FRAMING TIME: 17:00
5/22/03 AP 05/21/2003 09:15 AM LLONG
B130 01 5/27/03 CH BLDG, INSULATION TIME: 17:00
5/27/03 AP 05/23/2003 10:26 AM MRODGERS
B125 01 742/03 BI p BLDG, FINAL TIME: 17:00
6.3 C 07/21/2003 11:11 AM SSTANLEY
okay
---------------- COMMENTS AND NOTES---------------------
c, LAwo IY'oja %oi\ Sy'_Azm
QITz OF COLLEGE STATION
- WORK REQUEST
PAGE
1
REQ/JOB: WF0392382 / 001 PROJECT:
REQUEST DATE:
4/17/03
PRINT DATE:
4/17/03
CREW:
PRINT TIME:
13:59:43
SCHEDULE
LOCATION: 1045 WINDMEADOWS DR
START:DATES
4/17/03
77845
COMPLETION:
4/17/03
GEN. LOC: COLLEGE STATION LOC ID: 195774
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR: STYLECRAFT BLDRS (690-1222) ORIGIN:
CUSTOMER -WALK
IN
USER ID: LLONG AUTH: LLONG WORK TYPE:
ROUTINE
TEMP POLE PASSED
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
..�..,�. -... _..BU.TLD I NG . PERM I.T ,�
CITY QF. CIQLLEGE ,STAT, ;
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
. . . . . 03-00001041
Date 4/11/03
Property Address .
. . . . . 1045 WINDMEADOWS DR
Property ID
. . 650730-0101-0170
R # . . . . . . . .
. . . . . R113298
Tenant nbr, name .
. . . . . STYLECRAFT
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name .
. . . . . WESTFIELD VILLAGE PH 1
Property Use . . .
. . . . . RESIDENTIAL
Property Zoning . .
. . . . . PLANNED DEVL HOUSING
Application valuation . . . . 81312
Owner
Contractor
------------------------
BCS DEVELOPMENT CO
------------------------
STYLECRAFT BUILDERS
4090 SH-6 S
RANDY FRENCH
COLLEGE STATION
TX 77845 4060 SH 6 SOUTH
COLLEGE STATION
TX 77845
(979) 690-1222
--------------------------
Structure Information -------------------------
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL -MULTI -FAMILY
Other struct info .
. . . . EXTERIOR WALL TYPE
HARDIE STONE
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1232.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
LL
Permit Fee . . . .
388.00 Plan Check Fee
.00
Issue Date . . . .
4/11/03 Valuation . .
. . 81312
Expiration Date . .
10/08/03
Qty Unit Charge Per Extension
BASE FEE 260.00
32.00 4.0000 THOU BLDG, VAL 50001-100000 128.00
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT ,
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
i
BUILDING DEPT REPRESENTATIVE:
APPLICANT: ���
BUILDING PERMIT
CITY OF COLLEGE STATI
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 03-00001041 Date 4/11/03
----------------------------------------------------------------------------
Special Notes and Comments
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 388.00 388.00 .00 .00
Plan Check Total .00 .00 .00 .00
Other Fee Total 750.00 750.00 .00 .00
-------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATI
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00001041
Grand Total 1138.00 1138.00
Page 3
Date 4/11/03
.00 .00
-------------------------------------------
BUILDING DEP`T REPRESENTATIVE:�-f ------------------
APPLICANT: /!
TEMPORARY POLE PERMIT
` CITY OF COLLEGE STATI
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00001042 Date 4/11/03
Property Address . . . . . . 1045 WINDMEADOWS DR
Property ID . . 650730-0101-0170
R # . . . . . . . . . . . . . R113298
Application description . . . TEMP POLE
Subdivision Name . . . . . . WESTFIELD VILLAGE PH 1
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVL HOUSING
Application valuation . . . . 0
Owner Contractor
------------------------ ------------------------
BCS DEVELOPMENT CO STYLECRAFT BUILDERS
4090 SH-6 S RANDY FRENCH
COLLEGE STATION TX 77845 4060 SH 6 SOUTH
COLLEGE STATION TX 77845
(979) 690-1222
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . LL
Permit Fee . . . . 20.00
Issue Date . . . . 4/11/03 Valuation . . . . 0
----------------------------------------------------------------------------
Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00
Fee summary
-----------------
Permit Fee Total
Other Fee Total
Grand Total
Charged Paid
--------------------
20.00 20.00
45.00 45.00
65.00 65.00
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
Credited Due
--------------------
.00 .00
.00 .00
.00 .00
CITY OF COLLEGE STATION
WO1 zEQUEST PAGE 1
REQ/JOB: WF0391642 / 001 PROJECT: REQUEST DATE:
4/15/PRINT 03
CREW: PRINT TIME: 10:32:41
LOCATION: 1045 WINDMEADOWS DR SCHEDULE
STTART:DATES 4/15/03
77845 COMPLETION: 4/15/03
GEN. LOC: COLLEGE STATION LOC ID: 195774
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN
USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE
3/4" WATER 4" SEWER
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
3/4" WATER 4" SEWER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US
ADDRESS/LOCATION: O W in d in ea dt w S%
V V
LOT � BLOCK - SUBDIVISION elf- P 1 Pi d L/I l
BUSINESS/OWNER NAME:
p For Office Use Only
DATE: ` +
APPLICATION 1` +`
TEMP POLE #
PHONE:
PHASE /
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20
CONTRACTOR ADDRESS: 4090 State Highway 6 South
ELECTRICIAN: College Station Electric PLUMBER: Bass Plumbing
HVAC: Control Temp GOOD CENTS (Residential only): No
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK: Conventional Framing
STRUCTURE USE: Single Familv Residence
HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS VALUATION: ACCESSIBILITY STANDARD (T0 )SRO, TOTAL AREA: i�JHEATED AREA: i @t3a
(Cost` and Materials) P/
FX PUBLIC SEWER 3v U NUMBER OF BEDROOMS:
❑ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
QX SEWER TAP: 4"
INTERIOR WALL TYPE: Sheet Rock
J1Lc
�X WATER TAP:
3/a"
EXTERIOR WALL TYPE:
SIZE
OTHER TAP:
FOUNDATION TYPE:
SIZE
�X TEMP POLE
ROOF TYPE:
GARAGE TYPE:
SINGLE
DOUBLE XTRIPLE
ATTACHED
DETACHED F__] CARPORT
A n.
SIGNATURE OF APPLICANT:
Plans Examiner
Official Use Only
Zoning Official
I
Slab on Grade
Composition
C nts:
ES r NO
'zl d
Energy Code Compliance Information
% Glazing of exterior walls 10 %
Insulation R value of exterior walls R13
Insulation R value of ceiling 1 (flat areas)
R30
Insulation R value of ceiling 2 (vaulted areas/no attic)
R19
Glazing SHGC
.40
Glazing U-Factor
.65
R value of ductwork
R6
A/C SEER rating
12
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release 1
Data filename: S:\ACAD\MECcheck\1238-1232-1066 Windmeadows.cck
TITLE: Plan # 1238-1232 Front Porch
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 04/09/03
DATE OF PLANS: 04-09-03
PROJECT INFORMATION:
SPEC
1045 Windmeadows
College Station, Texas
COMPANY INFORMATION:
Stylecraft Builders, Inc.
4090 St. Hwy. 6 S.
College Station, Texas 77845
COMPLIANCE: Passes
Maximum UA = 522
Your Home UA = 435
16.7% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.40
D�'/
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter R-Value
R-Value
U-Factor
UA
Ceiling 1: Flat Ceiling or Scissor Truss
900
30.0
0.0
32
Ceiling 2: Cathedral Ceiling (no attic)
332
19.0
0.0
17
Wall 1: Wood Frame, 16" o.c.
1283
13.0
0.0
90
Window 1: Metal Frame, Double Pane with Low-E
127
0.670
85
SHGC: 0.40
Door 1: Solid
38
0.500
19
Door 2: Glass
18
0.440
8
SHGC: 0.40
Floor 3: Slab-On-Grade:Unheated
177
0.0
184
Insulation depth: 0.0'
Air Conditioner 2: Electric Central Air, 11 SEER
Furnace 2: Forced Hot Air, 80 AFUE
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release I (formerly MECchecl and to comply with the mandatory requirements listed in the
REScheckInspection Checklist.
Builder/Designer Date
REScheck Inspection Checklist
2000 IECC
RES check Software Version 3.5 Release 1
DATE: 04/09/03
TITLE: Plan # 1238-1232 Front Porch
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
[ ] 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation
Comments:
Above -Grade Walls:
[ ] 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
[ ] 1. Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.670
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
[ ] 1. Door 1: Solid, U-factor: 0.500
Comments:
[ ] 2. Door 2: Glass, U-factor: 0.440
Comments:
Floors:
[ ] 1. Floor 3: Slab-On-Grade:Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
1. Air Conditioner 2: Electric Central Air, 11 SEER or higher
Make and Model Number
2. Furnace 2: Forced Hot Air, 80 AFUE or higher
Make and Model Number
Solar Heat Gain Coefficient:
The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
[ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
3" clearance from insulation.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly
marked on the building plans or specifications.
Duct Insulation:
[ ] Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] Air filters are required in the return air system.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature ( F)
Up to 1„
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness in Inches by
Pipe Sizes
Piping System Types
Range F
2" Runouts
1" and Less
1.25"
to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
Area Calculator:
Description
imp
��■�■�����
Window Area Total: 126.65
04/09/03 14:14:50 1 /1
Area Calculator:
I=
Assembly Type
Description
OM2
-Garage
Door Area Total: 55.56
04/09/03 14:14:51 1 /1
Area Calculator:
Assembly Type
Comments/Description
Ceiling Area Total: 1232.00
04/09/03 14:14:51 1 /1
Area Calculator:
AssemblyType
Comments/Description
m■�■��
m■�■��
Exterior Wall Area Total: 1282.67
04/09/03 14:14:52 1 /1
Area Calculator:
Assembly
Comments/Description
Unheated ..■�■
Floor Area Total: 0.00
04/09/03 14:14:54 1 /1