HomeMy WebLinkAboutRES2003-01035PREPARED 9/02/03,
7:10:17
INSPECTION TICKET
PAGE 2
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 9/02/03
------------------------------------------------------------------------------------------------
ADDRESS
. : 825 PINE VALLEY DR
SUBDIV: PEBBLE CREEK
TENANT,
NBR: HUSFELD
HOMES
CONTRACTOR HUSFELD
HOMES INC
PHONE (979) 696-4369
OWNER
PEBBLE
CREEK DEVELOPMENT CO PHONE
PARCEL
497900-0030-0320
APPL NUMBER: 03-00001035
RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
4/21/03
TB
BLDG, FOUNDATION -SLAB TIME: 17:00
4/22/03
AP
LATE AFTERNOON
04/21/2003 09:00 AM LLONG
SLAB GROUND IN GARAGE BACK WALL RIGHT SIDE
STRINGS ON SETBACKS OKAY
B115 01
7/22/03
TB
BLDG, FRAMING TIME: 17:00
7/24/03
DP
07/22/2003 11:50 AM SSTANLEY
BLOCK OSB JOINTS ON FRONT OF HOUSE AND UPSTAIRS
ON JOINTS.
REPAIR FLOOR JOIST IN LEFT SIDE MIDDLE BEDROOM.
INADEQUATE
ATTIC ACCESS TO UPPER MECH. UNIT. FIREBLOCK 2ND
FLOOR
FIREPLACE. VENT FANS NOT VENTED OUT.
B115 02
7/24/03
TB
BLDG, FRAMING TIME: 17:00
7/25/03
AP
07/24/2003 08:12 AM KELMENDORF
first thing this afternoon please
B125 01
/02/03
B
BLDG, FINAL TIME: 17:00
09/02/2003 07:08 AM MALFORD
---------------------------------------
COMMENTS AND NOTES -------------------------------
�E LA-vtl 2R;
CITY OF COLLEGE STATION
WORK REQUEST
PAGE
1
RFQ/ B:
WF0395623 / 001 PROJECT: EQUESDATETE:
4/29/PRINT03
CREW:
PRINT TIME:
9:40:36
SCHEDULE
LOCATION:
825 PINE VALLEY DR
START:DATES
4/29/03
77845 COMPLETION:
4/29/03
GEN. LOC:
COLLEGE STATION
LOC ID: 195386
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION
PRIORITY: NORMAL
REQUESTOR:
HUSFELD HOMES (696-4369)
ORIGIN: CUSTOMER -WALK
IN
USER ID:
LLONG AUTH: LLONG
WORK TYPE: ROUTINE
TEMP POLE PASSED
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
CITY OF COLLEGE STATION
WOF REQUEST PAGE 1
REQ/JOB: WF0391211 1 001 PROJECT: REQUEST DATE: 4/14/03
PRINT DATE: 4/14/03
CREW: PRINT TIME: 9:31:07
LOCATION: 825 PINE VALLEY DR SCHEDULE
STTART:DATES 4/14/03
77845 COMPLETION: 4/14/03
GEN. LOC: COLLEGE STATION LOC ID: 195386
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: HUSFELD HOMES ORIGIN: CUSTOMER -WALK IN
USER ID: KELMENDORF AUTH: KELMENDORF WORK TYPE: ROUTINE
3/4" WATER 4" SEWER
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
3/4" WATER 4" SEWER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
lea i s
E'RM I. ..
kWC-ITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
03-00001036 Date 4/14/03
Property Address . . . . . .
825 PINE VALLEY DR
Property ID . .
497900-0030-0320
Application description . . .
TEMP POLE
Subdivision Name . . . . . .
PEBBLE CREEK
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
------------------------
Contractor
PEBBLE CREEK DEVELOPMENT CO
------------------------
HUSFELD HOMES INC
%YOUNG BROTHERS
DENNIS HUSFELD
PO BOX 1800
3204 LONGMIRE
WACO TX 767031800
COLLEGE STATION
TX 77845
----------------------------------------------------------------------------
(979) 696-4369
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . KE
Permit Fee . . . . 20.00
Issue Date . . . . 4/14/03
------------------------------------------------------------------------------
Valuation . . . .
0
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
Fee summary Charged
Paid Credited
Due
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
------------------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00001035 Date 4/14/03
Property Address . . . . . . 825 PINE VALLEY DR
Property ID 497900-0030-0320
R # . . . . R112678
Tenant nbr, name . . . . . . HUSFELD HOMES
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . PEBBLE CREEK
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 200500
Owner Contractor
------------------------ ------------------------
PEBBLE CREEK DEVELOPMENT CO HUSFELD HOMES INC
%YOUNG BROTHERS
DENNIS HUSFELD
PO BOX 1800
3204 LONGMIRE
WACO
TX 767031800 COLLEGE STATION
TX 77845
(979) 6 9 6 - 4 3 6 9
--------------------------
Structure Information -------------------------
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL -MULTI -FAMILY
Other struct info .
. . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
3.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
3037.00
INTERIOR WALL TYPE
2X4 16"OC,GYPS-
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
KE
Permit Fee . . . .
763.00 Plan Check Fee
.00
Issue Date . . . .
4/14/03 Valuation . . .
. 200500
Expiration Date . .
10/11/03
Qty Unit Charge Per Extension
BASE FEE 460.00
101.00 3.0000 THOU BLDG, VAL 100001-500000 303.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
BUILDING DEPT REPRESENTATIVE:
n
APPLICANT: ���
BUILDING PERMIT
CITY OF COLLEGE STATIOr
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 03-00001035 Date 4/14/03
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
STAIRS SHALL COMPLY WITH SECTION R-314 (2000 IRC) OR SECTION
1003.3.3 (2000 IBC) AS APPROPRIATE
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 763.00 763.00 .00 .00
Plan Check Total .00 .00 .00 .00
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . 03-00001035
Other Fee Total 750.00 750.00
Grand Total 1513.00 1513.00
BUILDING DEPT REPRESENTATIVE:
APPLICANT: (, "
Page 3
Date 4/14/03
.00 .00
.00 .00
ILICATION FOR BUILDING PER
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEG E-STATION.TX.US
For OTce Use QNy
DATE•
APPLICATION a
TEMP POLE #
ADDRESS/LOIN: 92-5 ONE v �E ,
LOT 3 7- BLOCK 3 0 SUBDIVISION PE 6 6 G 6" CAC- e K
BUSINESS/OWNER NAME: H v S F E,-t> H oM c s PHONE: b l (v- y 36 9
CONTRACTOR/HOMEOWNER: } V 5 FI:L t> HoM Gs PHONE: 476 - y34-y
CONTRACTOR ADDRESS: 37_0 `t L. oiy&m I xg pe
ELECTRICIAN: GwW PLUMBER: RZUiVS
HVAC: `7 GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK: iVEW "t=, 12,
STRUCTURE USE: s . F . D
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJE REGISTRATION# EABPRJ
VALUATION: $ 2 00, 5 vy . v v TOTAL AREA: `to 1 '7 HEATED AREA: 3 0 3 7
(Cost of Labor and Materials)
® PUBLIC SEWER
SEPTICITREATMENT SYSTEM
SEWER TAP: T '
SIZE
[R WATER TAP: 314 "
SIZE
❑ OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE: SINGLE a
ATTACI-
SIGNATURE OF APPLICANT:
NUMBER OF BEDROOMS: 4
NUMBER OF BATHROOMS: 3
INTERIOR WALL TYPE: Zx*SitiDr t6`I DC, &YP, 5tKATHIN4
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE Q TRIPLE
g2lcK-
_ 51." ON L Rk D E
COMP. SN�n►yC.E3
I l Ofcial Use Only
(( 03 menu:
Plans Examiner Zoning Official �YEor NO
Energy Code Compliance Information
% Glazing of exterior walls
13 .2
Insulation R value of exterior walls
13
Insulation R value of ceiling 1 (flat areas)
3 O
Insulation R value of ceiling 2 (vaulted areas/no attic)
19
Glazing SHGC
0.3
Glazing U-Factor
0. 6 y
R value of ductwork
A/C SEER rating
12
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER#
DATE:
0 — 035
II 03
BUILDING ADDRESS:
a5 a� e
I. Foundation Requirements
NA/OK
A. Concrete minimum f'c of 3000 PSI
oK
B. Minimum four 4 inch slab thickness
C. Vapor barrier
1. 6 mil poly
D. Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
2. Dimensions
3. Footings 30" exterior, 24" interior unless over 60' Ion
4. Spacing of beams does not exceed 15'
E. Reinforcement details to meet minimum requirements
1. Slab reinforcement
2. Exterior beam reinforcement
3. Interior beam reinforcement
4. Masonry fireplace foundation reinforcement
F. Wood foundation details indicated
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/OK
A. Girder or sill dimensions, grade & species
b
B. Floor joist size, spacing, grade & direction of span indicted on plans
C. Treated sill plate or bottom plate
D. Tenant separation in duplex
�((�
1. One -hour rated extending to roof deck
E. Header sizes indicated on plans
nvl
F. Emergency bedroom egress
1. Exit direct to outside
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
b. Maximum sill height of forty-four 44 inches above finished floor
G. O enable bathroom window required when mechanical ventilation is not provided
H. Stud grade andspacing
I. Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J. Roof framing Ian or elevation shown
K. Ceiling joist size, spacing, rade and direction of span indicated on plans
L. Attic access location and size indicated on plans
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
NA/OK
M. Span exceeding code tables must be engineered
N. Rafter size, spacing, grade, roof slope & bracing (if required to reduce span) indicated
on plans
O. Roof covering
1. Roof decking indicated on plans
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
Q. Tempered Glass required in all hazardous locations
R. Overhangs not allowed on zero lot line construction
S. Protected openings on walls < three feet from property line
Nk
III. Stairway Requirements
NA/OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements (to be indicated on plans)
NA/OK
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. Masonry fireplace requires 2" clearance from all combustible materials
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of
the buildingwithin ten 10 feet horizontal
J
l�
V. Electrical Service Requirements
OK
A. Electrical plan to include:
o
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
5. Panel location
VI. Plumbing Requirements
A/OK
A. Pressure reducing valve required when water pressure exceeds 80 psi
o
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N OK
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
p
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
VIII. Energy Requirements
NA/OK
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
OK
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Overhangs not allowed on zero lot line construction
20' triangle clear at corner
Required parking
Street Ordinance Requirements
NA/OK-
-Maximum drive width for residence is 28'
Minimum 30 feet from driveway to side(intersecting) street
—
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
Subdivision Regulations — Ordinance 690 NA/OK
Approved subdivision d
Plat filed
Flood lain Regulations — Ordinance 1301 OK
Does not block any water course
Need elevation certificate
ZONING OFFICIAL DATE
PLANS EXAMINER DATE
Na
102.
i 10' PUE _ L
� 1
I I
I �
I I
-------- 25' BLDG LINE
I I
I �
I I
I �
I
I
J� I -
_
�� I ul
O
—
- I
I z
I
I I
, I
I I
I �
I I
I �
I I
I 25 BLDG LINE
I
I I
I I
I 10' PUE
102.50'
FOR PEBBLE CREEK VlAtll AREA. 3037 s,_ F-r. Husfeld Homes
SITE PLAN LOT: 32 PNASE 9-A CUSTOM HOME BUHAING
SCALE, I' 20' BLOCK: 30 825 PINE VALLEY DR. 5LA9 AREA. 4017 so. Fr- poor+¢. Fix.
(979) L9L-4369 (419) 7"-7919
Permit Number
MECcheck Compliance Report Checked By/Date
2000 IECC
MECcheck Software Version 3.3 Release lb
Data filename: C:\Program Files\Check\MECcheck\pine valley 825.cck
TITLE: 825 Pine Valley
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 04/08/03
DATE OF PLANS: 4-8-03
PROJECT INFORMATION:
Pebble Creek
COMPANY INFORMATION:
Husfeld Homes, Inc.
COMPLIANCE: Passes
Maximum UA = 1156
Your Home = 890
23.0% Better Than Code
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimelgr R-Value
R-Value
-F ct r ,UA
Ceiling 1: Flat Ceiling or Scissor Truss
2378
30.0
0.0
83
Ceiling 2: Cathedral Ceiling (no attic)
150
19.0
0.0
8
Wall 1: Wood Frame, 16" o.c.
3232
13.0
3.6
190
Window 1: Metal Frame, Double Pane with Low-E
401
0.640
257
Window 2: Other
25
0.480
12
Door 4: Glass
18
0.390
7
Door 2: Glass
18
0.390
7
Door 5: Solid
18
0.150
3
Floor 1: Unheated Slab -On -Grade, 2.0' insul.
310
0.0
323
Air Conditioner 1: Electric Central Air, 12 SEER
Furnace 1: Forced Hot Air, 78 AFUE
Boiler 2: Gas -Fired Steam, 75 AFUE
Boiler 2: Gas -Fired Steam, 75 AFUE
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been
designed to meet the 2000 IECC requirements in MECcheck Version 3.3 Release lb and to comply with the
mandatory requirements listed in the MECcheck Inspection Checklist.
Builder/Designer HOF F LP H OM ES N C-. Date q f_1
Energy Label
M6C
Street Address_ 8 Z,G7 PrNE V4 c LC-y
This horse Includes the following energy features:
Insulation R-Values
Insukdhig
P11eal it g Ll-Valgq
3 b Ceiling
_ Ceiling
3.6 13 _ Wall
GlazingMoor U-Factors
LI-Factor
Windows
4 `%7 Windows
Sliding Glass Doors
Wall 6. 3 / Doors
Floor 0• /5 Doors
Basement Wall
Crawl Space Wall
Slab
Duct
Mechanical System
Heating System
Cooling System
Water Heater
Other Energy Features
Type and Fuel
�A-s Fv2�i/,gG E
Ec.Ez�r�
Gas
Efficiency
2 SEED
Builder ����cc.n �oM�I nr�. Date q-i - 0 3
Vorslon 3.0; Apr# 2000
U.S. Dept. of Housing and U"n Developmenl / Rural Econornlc and Communlly Devolopmenl
U.S. Dept. of Energy / Pacific Nodliwesl National Latxnalory
EF