HomeMy WebLinkAboutRES2003-01021r
P 1W'A!E7D 9/11/03, 14:05:24 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 9/11/03
------------------------------------------------------------------------------------------------
ADDRESS . : 2 VISTA LN SUBDIV: HARVEY HILLSIDES
CONTRACTOR R M DUDLEY PHONE (979) 776-2135
OWNER DUDLEY, MARK PHONE
PARCEL 316000-0001-0420
APPL NUMBER: 03-00001021 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/22/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00
4/23/03 AP 04/22/2003 08:35 AM SSTANLEY
GARAGE AREA
Bl 01 6/02/03 OC BLDG, FRAMING TIME: 17:00
6/03/03 AP 06/02/2003 10:48 AM KELMENDORF
sheetrock top of fireplace
C windows on both si_deg of center- h;;rk dnn, nPat3 rn he
emr hjr nn
B130 01 6/11/03 CH BLDG, INSULATION TIME: 17:00 b
6/11/03 AP 06/10/2003 03:33 PM SSTANLEY '
B125 01 9 11/A3 BI BLDG, FINAL TIME: 17:00
1
COMMENTS AND NOTES k_V1
------------------------------------------------------------------------
✓l
0 !3o i o3
,�No _Trr)�i.�1or
10/20/20 - -0:30 AM FROM: Fax TO: (979) 764-3496 PAGE: OF 001
Date: 10/20/2003
To: Oscar Chavarria
City of College Station Development Services
From: Michael Ham
Subject: Building Final - #2 Vista Lane
I have attached a letter from the window supplier for the project certifying that the
windows which are required to be tempered have been ordered and will be install as soon
as they arrive. Please let me know if you need any additional information or if a re -
inspection will be required. Thank you for your help.
Sincerely,
Michael Ham
RM Dudley Construction
979-776-2135 Office
979-776-2235 Fax
CITY OF COLLEGE STATION
WORK ,QUEST
PAGE
1
REQ/JOB:
WF0391133 / 001 PROJECT:
REQUEST DATE:
4/11/03
PRINT DATE:
4/11/03
CREW:
PRINT TIME:
16:06:53
SCHEDULE
LOCATION:
2 VISTA LN
START:DATES
4/11/03
77845
COMPLETION:
4/11/03
GEN. LOC:
COLLEGE STATION LOC ID:
195962
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
RM DUDLEY (776-2135) ORIGIN:
CUSTOMER -WALK
IN
USER ID:
LLONG AUTH: LLONG WORK
TYPE:
ROUTINE
4" SEWER
/ 3/4" WATER
4" SEWER
/ 3/4" WATER
Category
code CS -CUSTOMER SERVICES
CSCS
Task code:
SET UP NEW UTILITY ACCT
SET
Facility
ID
Assigned Department:
OT-CUSTOMER SERVICE
+ BUILDING PERMIT
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 03-00001021
Date 4/11/03
Property Address . .
. . . . 2 VISTA IN
Property ID . . . . .
. . . . 316000-0001-0420
R 4 . . . . . . . . .
. . . . R28554
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . HARVEY HILLSIDES
Property Use . . . .
. . . .
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 187100
Owner
Contractor
------------------------
DUDLEY, MARK
------------------------
R M DUDLEY
8 LORI LN
MARK DUDLEY
COLLEGE STATION
TX 778459482 8 LORI LANE
COLLEGE STATION
TX 77845
(979) 776-2135
--------------------------
Structure Information -------------------------
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL -MULTI -FAMILY
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
1.00
TYPE OF GARAGE (ATT/DET)
XX
HEATED AREA
3100,00
INTERIOR WALL TYPE
WOOD FRAME
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
-------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
-------
Additional desc . .
LL
Permit Fee . . . .
724.00 Plan Check Fee
.00
Issue Date . . . .
4/11/03 Valuation
187100
Expiration Date . .
10/08/03
Qty Unit Charge
Per
Extension
BASE FEE
460.00
88.00 3.0000
THOU BLDG, VAL 100001-500000
264.00
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ADDRESS ON BUILDING:
FRONT - 5" HIGH NUMBERS
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
- - - - - - - - - - - - - - - - - - - - — -----------------
BUILDING DEPT RE T E:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
2
Application Number . . . . . 03-00001021 Date
----------------------------------------------------------------------------
4/11/03
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
PROVIDE SANTTARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Fee summary Charged Paid Credited Due
-----------------
----------------------------------------
Permit Fee Total 724.00 724.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1474.00 1474.00 .00
.00
-----------------T -------------- ----- -------------------------
BUILDING DEPT RE TIVE:
APPLICANT: ��
A LICATION FOR BUILDING PERI
CITY OF COLLEGE STATION
E3 1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEG E.STATION.TX.US
ADDRESS/LOCATION: ►` S 43 ;� ✓� `�
LOT y;� r_, BLOCK SUBDIVISION
BUSINESS/OWNER NAME:
CONTRACTOR/! I0ME()WNE�R:
CONTRACTOR ADDRESS:
ELECTRICIAN:
,^, .. t.
HVAC: kj-'_d_ l .c9 `'I'
w, oft. Uw onr
DATE:-4 1`�
APPLICATION # lJ
TEMP POLE #
PHONE:
GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) JREMOD EUREN OVATION SWIMMING POOL
DESCRIPTION OF WORK:
STRUCTURE USE: g-n'� 14c-c-
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) P OJECT REGISTRATION# EABPRJ
VALUATION: $ TOTAL AREA: 340 HEATED AREA: O
(Cost of Labor and Materials)
9APUBLIC SEWER
Q SEPTIC/TREATMENT SYSTEM
[�J�SEWER TAP: 1/
S¢E
t WATER TAP: /Q- `
OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE: SINGLE Q
ATTACHED a
SIGNATURE OF APPLICANT:
NUMBER OF BEDROOMS: 3
NUMBER OF BATHROOMS: 3
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
IBLE Q TRIPLE
CHED 1 a 949R
Official Use Only
Plans Examiner Zoning Official
NO
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls l` 1 3
Insulation R value of ceiling 1 (flat areas) Z- 3v
Insulation R value of ceiling 2 (vaulted areas/no attic) F--30
Glazing SHGC D qO
Glazing U-Factor Oo 6
R value of ductworky
A/C SEER rating % 2
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
PLAN REVIEW/PERMIT NUMBER# 3DATE:
D�- �fJ5
BUILDING ADDRESS:
I. Foundation Requirements
N OK
A.
Concrete minimum f'c of 3000 PSI
B.
Minimum four 4 inch slab thickness
<
C.
Vapor barrier
1. 6 mil poly
Ale-
D.
Slab/beam or pier layout shown
1. Footings/beams are continuous over the length and width of foundation
o
2. Dimensions
e <
3. Footings 30" exterior, 24" interior unless over 60' Ion
O
4. Spacing of beams does not exceed 15'
4
E.
Reinforcement details to meet minimum requirements
r--,
1. Slab reinforcement
6
2. Exterior beam reinforcement
e/<
3. Interior beam reinforcement
av C
4. Masonry fireplace foundation reinforcement
�----
F.
Wood foundation details indicated
—.
II. Framing: Floor, Wall, Ceiling and Roof Requirements
NA/OK
A.
Girder or sill dimensions, grade & species
�.
B.
Floor joist size, spacing, grade & direction of span indicted on plans
--»
C.
Treated sill plate or bottom plate
m
D.
Tenant separation in duplex
►T
1. One -hour rated extending to roof deck
E.
Header sizes indicated on plans
O .�
F.
Emergency bedroom egress
.r-
1. Exit direct to outside
ok
2. O enable window
a. Twenty 20 inch clear width by twenty-four 24 inch clear height
D
b. Maximum sill height of forty-four 44 inches above finished floor
G.
O enable bathroom window required when mechanical ventilation is not provided
OV
H.
Stud grade andspacing
I.
Exterior wall details
1. Exterior wall covering indicated on plans
2. Sheathing indicated on plans
3. Moisture barrier indicated on plans
J.
Roof framing Ian or elevation shown
K.
Ceiling joist size, spacing, rade and direction of span indicated on plans
L.
Attic access location and size indicated on plans
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
II. Framing: Floor, Wall, Ceiling and Roof Requirements continued
N K
M. Span exceeding code tables must be engineered
N. Rafter size, spacing, grade, roof slope & bracing (if required to reduce span) indicated
on plans
c
O. Roof covering
1. Roof decking indicated on plans
2. Moisture barrier indicated on plans
P. All girders & beams for support of floors, walls, ceiling & roofs must have the size, grade &
location indicated on plans
04
Q. Tempered Glass required in all hazardous locations
R. Overhangs not allowed on zero lot line construction
✓j.
S. Protected openings on walls < three feet from property line
III. Stairway Requirements
OK
A. Stairway Details
1. Maximum riser height 7-3/4 inches
2. Minimum tread width 10 inches
3. Stairway risers are uniform
4. Stairway width not less than 36 inches
5. Stairway headroom not less that six ft. eight 6-8
B. Winder details
1. Treads a minimum of six 6 inches on narrow edge
2. Treads a minimum often (10) inches at a distance of twelve (12) inches from the
narrow edge
C. Spiral stairway details
1. Riser height less than nine and one-half 9-1/2 inches
2. Treads a minimum of seven and one-half (7-1/2) inches at a distance of twelve (12)
inches from the narrow edge
3. Stairway width not less than twenty-six inches
4. Headroom required not less than six ft six 6-6 inches
5. All treads must be identical
D. Guards/handrail details
1. Guards required when a porch, deck, balcony or landing is thirty (30) inches
above grade or finished floor
2. Handrails are required on stairways located two or more risers above floor/grade
3. Handrails must be thirty-four to thirty-eight (34-38) inches when measured from the
leading edge of the tread
4. Handrails must not project more than four & one-half (4-1/2) inches into width of a
stairway
5. Guards must be a minimum of thirty-six 36 inches above finished floor
6. Guards & handrails along open-side(s) of stairway must have intermediate
railing or uprights that prevent the passage of a four 4 inch sphere
IV. Fireplace Requirements to be indicated onplans)
NA/ K
A. Hearth extensions
1. Fireplace opening < 6 s , ft, extensions: 8" & 16" forward
2. Fireplace opening > 6 s . ft. extensions: 12" side & 20" forward
B. masonry fireplace requires 2" clearance from all combustible materials
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
C. Chimneys must extend at least three (3) feet higher than the highest point where it
projects through the roof of a building & at least two (2) feet higher than any portion of
the building within ten 10 feet horizontal
/
V. Electrical Service Requirements
NA/OK
A. Electrical plan to include:
1. Electrical fixtures & switches indicated
2. Smoke detector locations indicated as required
3. GFI circuits indicated where required
4. Arc fault protection for bedroom circuits
A
5. Panel location
of
via, r
VI. Plumbing Requirements
NA/ K
A. Pressure reducing valve required when water pressure exceeds 80 psi
B. Plumbing access to bathtubs
C. Means for thermal expansion provided when required
D. Water heaters elevated 18" when installed in the garage or room directly off garage
VII. Mechanical Requirements
N O
A. All mechanical ventilation's in bathrooms & range hood ventilation must be ducted to
outside excludes ductless units
B. Attic installed H.V.A.C. requirements:
1. Twenty-four (24) inch wide unobstructed walkway from attic access to equipment
must be provided
2. Attic access located within 20 feet of equipment
C. Combustion air supplied for gas appliances when required)
Vill. Energy Requirements
NA/
A. Compliance software worksheet MECcheck submitted, or
B. Energy data supplied Percent of glazing, insulation R-values, window U-values, etc.
Zoning Ordinance Requirements — Ordinance 850
N
Permitted use for district
Density requirements
Minimum lot size
Setbacks
Easements
Overhangs not allowed on zero lot line construction
20' triangle clear at corner
Required parking
Street Ordinance Requirements
NA/IPK
Maximum drive width for residence is 28'
Minimum 30 feet from driveway to side(intersecting) street
PLAN REVIEW
ONE and TWO FAMILY OCCUPANCY REQUIREMENTS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TEXAS 77840
(979) 764-3570; (979) 764-3496 FAX
I Subdivision Reaulations — Ordinance 690 1 NA/OK I
Approved subdivision
Plat filed
Flood lain Regulations — Ordinance 1301 NA/OK
Does not block any water course
Need elevation certificate
ZONING OFFICIAL
C tW
PLANS EXAMINER
DATE
z 1a � Iry
DATE