PREPARED 8/12/03, 6:58:53 INSPECTION TICKET PAGE 6
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 8/12/03
-------=----------------------------------------------------------------------------------------
ADDRESS . : 3737 ESSEN LOOP SUBDIV: EDELWEISS GARTENS PH 1
TENANT, NBR: SFR-EDELWEISS GARTENS
CONTRACTOR OAKWOOD CUSTOM HOMES PHONE (979) 690-1504
OWNER OAKWOOD CUSTOM HOME BUILDERS PHONE
PARCEL 244030-0101-0270
APPL NUMBER: 03-00001017 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 4/21/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00
4/22/03 AP 04/21/2003 08:53 AM LLONG
STRINGS PULLED
CLEAN WOOD AND DIRT FROM BEAMS
NEED SLAB GROUND AND CHAIRS
B115 01 5/19/03 CH BLDG, FRAMING TIME: 17:00
5/20/03 AP 05/19/2003 10:09 AM LLONG
WINDOW NEEDS TO BE TEMPERED NEXT TO BACK DOOR n
B125;01 8/12 03 BI BLDG, FINAL TIME: 17:00
Z_ 08/11/2003 12:20 PM KELMENDORF
--------------- ---------- ---- COMMENTS AND NOTES
e
5
Linda Long - Insulation request inspectio alt 3737 Essen Loop, #03-1017 Page 1
From: Brian Henry
To: Long, Linda
Date: 5/22/03 11:17AM
Subject: Insulation request inspection result, 3737 Essen Loop, #03-1017
Print for File
Inspected insulation, 3737 Essen Loop, #03-1017, Oakwood Homes, 5-22-03
Inspection result: Inspected OK for Good Cents
Notes:
Seal exterior wall corners & "TT beams
CC: Stanley, Susan
CITY OF COLLEGE STATION
WORK QUEST
PAGE
1
REQ/JOB:
WF0391693 / 001 PROJECT:
REQUEST DATE:
4/15/03
PRINT DATE:
4/15/03
CREW:
PRINT TIME:
16:02:59
SCHEDULE
LOCATION:
3737 ESSEN LOOP
START:DAT�S15/03
77845
COMPLETION:
4/15/03
GEN. LOC:
COLLEGE STATION LOC ID:
193846
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
OAKWOOD CUSTOM HOMES ORIGIN:
CUSTOMER -WALK
IN
USER ID:
SSTANLEY AUTH: SSTANLEY WORK
TYPE:
ROUTINE
TEMP POLE PASSED
TEMP POLE
PASSED
Category
code CS -CUSTOMER SERVICES
CSCS
Task code:
SET UP NEW UTILITY ACCT
SET
Facility
ID
Assigned Department:
OT-CUSTOMER SERVICE
CITY OF COLLEGE STATION
WORK QUEST
PAGE
1
REQ/JOB:
WF0391129 / 001 PROJECT:
REQUEST DATE:
PRINT DATE:
4/11/03
CREW:
PRINT TIME:
15:53:02
SCHEDULE
LOCATION:
3737 ESSEN LOOP
STTART:DATES
4/11/03
77845
COMPLETION:
4/11/03
GEN. LOC:
COLLEGE STATION LOC ID: 193846
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
OAKWOOD CUSTOM HOMES-690-1504 ORIGIN:
CUSTOMER -WALK
IN
USER ID:
LLONG AUTH: LLONG WORK TYPE:
ROUTINE
4" SEWER
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
/ 3/4" WATER
4" SEWER / 3/4" WATER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
1101 TEXAS AVE v
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
. . . . . 03-00001017 Date 4/11/03
Property Address .
. . . . . 3737 ESSEN LOOP
Property ID
. . 244030-0101-0270
R # . . . . . . . .
. . . . . R111665
Tenant nbr, name .
. . . . . SFR-EDELWEISS GARTENS
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name .
. . . . . EDELWEISS GARTENS PH 1
Property Use . . .
. . . . . RESIDENTIAL
Property Zoning . .
. . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 110000
Owner
Contractor
------------------------
OAKWOOD CUSTOM HOME
------------------------
BUILDERS OAKWOOD CUSTOM HOMES
L.L.C.
ALTON OFCZARZAK
PO BOX 9849
PO BOX 9849
COLLEGE STATION
TX 778427849 COLLEGE STATION TX 77842
(979) 690-1504
--------------------------
Structure Information -------------------------
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL-SFR/DUPLEX
Other struct info .
. . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
HEATED AREA 1615.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
LL
Permit Fee . . . .
490.00 Plan Check Fee .00
Issue Date . . . .
4/11/03 Valuation . . . . 110000
Expiration Date . .
10/08/03
Qty Unit Charge
Per Extension
BASE FEE 460.00
10.00 3.0000
THOU BLDG, VAL 100001-500000 30.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS
THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS
WITHIN 20 FEET OF MECHANICAL EQUIPMENT
-------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATIOP
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 03-00001017 Date 4/11/03
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
-
-----------------------------
------------ --- r� --- - ----------------
BUILDING DEPT REPRESENTATIVE: ///
APPLICANT:l---
BUILDING PERMIT
CITY OF COLLEGE STATIOI
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
3
Application Number
----------------------------------------------------------------------------
. . . . .
03-00001017
Date
4/11/03
Other Fees . . . .
. . . . .
WATER TAP 3/4"
CITY INSTL
400.00
Fee summary
-----------------
Charged
Paid
Credited
Due
Permit Fee Total
----------
490.00
----------
490.00
--------------------
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1240.00
1240.00
.00
.00
-- -----------------
BUILDING DEPT REPRESENTATIVE: — ---�
APPLICANT: ./ Z cam: .
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATIO:
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE:
----------------------------------------------------------------------------
(979)764-3570 FAX: (979)764-3496
Application Number
. . . . . 03-00001018 Date 4/11/03
Property Address
. . . . . . 3737 ESSEN LOOP
Property ID . . .
. . . . . . 244030-0101-0270
Application description . . . TEMP POLE
Subdivision Name
. . . . . . EDELWEISS GARTENS PH 1
Property Use . .
. . . . . . RESIDENTIAL
Property Zoning .
. . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner
------------------------
Contractor
------------------------
OAKWOOD CUSTOM HOME BUILDERS OAKWOOD CUSTOM HOMES
L.L.C.
ALTON OFCZARZAK
PO BOX 9849
PO BOX 9849
COLLEGE STATION
TX 778427849 COLLEGE STATION
TX 77842
(979) 690-1504
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE PERMIT
Additional desc .
. LL
Permit Fee . . .
. 20.00
Issue Date . . .
----------------------------------------------------------------------------
. 4/11/03 Valuation . . . .
0
Other Fees . . .
. . . . . . TEMP ELECT POLE CONNECT
45.00
Fee summary
-----------------
Charged Paid Credited
Due
Permit Fee Total
----------------------------------------
20.00 20.00 .00
.00
Other Fee Total
45.00 45.00 .00
.00
Grand Total
65.00 65.00 .00
.00
BUILDING DEPT REP SENTATIVE:
APPLICANT: .��
LL
lFa Office Use Only
-i
APPLICATION FOR BUILDING PERMIT DATE: ✓ 1/�'�/aa�
CITY OF COLLEGE STATION APPLICATION # V J ( 1
C3 1101 TEXAS AVENUE /�
COLLEGE STATION, TX 77840 TEMP POLE # 03 s )0'9
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STATION.TX.US
5737
ADDRESS/LOCATION: za2ig Ez5scAj Lnojo
��-^^''�
LOT 7_1 BLOCK I SUBDIVISION &1e L64GjS' S (�► AP_-reA.CS
"
BUSINESS/OWNER NAME: tDA4wcoD C&AST-DM t}&MGBJI&f.PHONE:
CONTRACTOR/HOMEOWNER: _51411"e PHONE:
CONTRACTOR ADDRESS: ylob o G Soy, i4 C6114m ' 6369 Zx 7 7?46`
ELECTRICIAN: (',i4MPI-Agr /Qk,-C - _ PLUMBER: AWi61,0.,,W ��u,•, �i�y �.
HVAC: 4'lG GOOD CENTS Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL
DESCRIPTION OF WORK: AIC41 aK�`- GbaSTXterAnA,
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
00 TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
Lf %Q VALUATION: $ //ytJ TOTAL AREA: Z�-'-5� HEATED AREA:
(Cost of Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
SEWER TAP:
e INTERIOR WALL TYPE:
SIZE
WATER TAP:
% EXTERIOR WALL TYPE:
SIZE
OTHER TAP:
FOUNDATION TYPE:
�EMP POLE
SIZE
ROOF TYPE:
GARAGE TYPE:
SINGLE OUB E�!r TRIPLE
3
2
SG4"
_GAT ✓�r„n
F7
ATTACH d DE ED ARP
SIGNATURE OF APPLICANT:
Official Use Only
iJ GLc� -6 l �D /'e3 (YEJ or NO
Plans Examiner Zoning Official
�Eo
X- Y/CII)mn
/�
v I Gi y, v�5'
j— _ f
D� G X T� r�'r O Y w!' �I S
• ,—.�� O
't7-y1S1-1flkIL'O i V4JVt O r e�v,'or wcc `/(
r f VR I�� o cC,'/" 5 1 �'laf a''�a 5) o 30
1 1 1\ l/'Gt jvt G D r C E I �r1+C Z VGc
-20
fs (a z ```S V_ FCA r-� m ; 7 a
✓a(�e D e4-per/< /
F re,
OAKWOODD CUSTOM HOME:UILDDERS
EDELWEISS GARTENS
COLLEGE STATION, TX
48- 06 ,
LOT 2%
BLOCK I 10 ° P. U. E.
SCALE: 1/16' = P-0' N
20e LANDSCAPE Zo
0 5 10 20 BUFFER
\ Iffm� FGF"fAm
_
\ 00
\ � o
LIVINGIs S`
wom" '
o •m"
WA
v �
swam
i
11 er_
or 11 -
25' SET6ACK
CA
cn
w
M
MECcheck Compliance Report
2000 IECC
MECcheck Software Version 3.2 Release I
TITLE: SEAHORN2
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 04/07/03
DATE OF PLANS: 04/07/03
PROJECT INFORMATION:
EDELWEISS GARTENS
COLLEGE STATION, TEXAS
LOT 27, BLOCK I
COMPANY INFORMATION:
OAKWOOD CUSTOM HOMEBUILDERS, L.L.C.
NOTES:
NEW CONSTRUCTION
COMPLIANCE: Passes
Maximum UA = 693
Your Home = 561
19.0% Better Than Code
Ceiling 1: Flat Ceiling or Scissor Truss
Ceiling 2: Cathedral Ceiling (no attic)
Wall l: Wood Frame, 16" o.c.
Window 1: Metal Frame, Double Pane
Door l: Glass
Slab 1: Unheated, 0.0' insul.
Air Conditioner 1: Electric Central Air, 12 SEER
Furnace l: Forced Hot Air, 78 AFUE
--Id/
Permit Number
Checked By/Date
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
1474 30.0
0.0
52
141 19.0
0.0
7
1691 13.0
0.0
118
203
0.670 136
55
0.140 8
230
0.0
240
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building
plans, specifications, and other calculations submitted with the permit application. The proposed building has
been designed to meet 3t,4 2000 IECC requirements in MECcheck Version 3.2 Release lb.
Builder/Designer Date d V b -71d
MECcheck Inspection Checklist
2000 IECC
MECcheck Software Version 3.2 Release lb
DATE: 04/07/03
TITLE: SEAHORN2
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
[ ] 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation
Comments:
Above -Grade Walls:
[ ] 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
[ ] 1. Window 1: Metal Frame, Double Pane, U-factor: 0.670
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
[ ] 1. Door 1: Glass, U-factor: 0.140
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Slab -On -Grade Floors:
[ ] I. Slab 1: Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
[ ] 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher
Make and Model Number
[ ] 2. Furnace 1: Forced Hot Air, 78 AFUE or higher
Make and Model Number
[ ) The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
[ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate
air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation.
Materials Identification:
Materials and equipment must be installed in accordint to the manufacturer's installation instructions.
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values, glazing U-values, and cooling equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at
less than 2 in. w.g. (500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] Air filters are required in the return air system.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 T must be insulated to the
I levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches bPipe Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature (F)
Up to 1„
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)