Loading...
HomeMy WebLinkAboutRES2003-01015JAN ZZ '04 01:59PM CERTIFIED COPY P. i 4060 Highway 6 South College Station, TX 77845 January 22, 2004 1101 Texas Avenue College Station, TX 77845 Dear Mr, Sims: This letter is in regards to 3709 Bridal Trails Court, Permit #03-00001015. The original permit is dated April -11, 2003, however due to complications we were unable to build this home until the present date. This has cause the permit to expire, We are requesting an extension on this permit so that we can start the building process on this lot. If you have any questions regarding this request please contact our office at (979) 690-1504. Either Alton, or myself can help. Thank you, d April M. Walters Project Coordinator Oakwood Custom Homebuilders, L.L.C. CITY OF COLLEGE STATION . BUILDING PERMIT ISSUED TO OAKWOOD CUSTOM HOMES (CONTRACTOR/OW NER) FOR THE CONSTRUCTION OF: Single -Family Residential ❑ ADDITION ® NEW ❑ REMODELING ❑ REPAIR STREET LOCATION: LOT.", 5 BLOCK: 2 ADDITION: PERMIT NO. 03-1015. GATE OF ISSUE: TEMP POLE PERMIT NO. 03-1016 L-CLCe �s � IS TO I R30 R19 .17 .67 6 12 NG CONSTRUCTION. CITY OF COLLEGE STATION WORK REQUEST REQ/JOB: WF0490676 / 001 PROJECT: CREW: LOCATION: 3709 BRIDLE TRAILS CT 77845 GEN. LOC: COLLEGE STATION LOC ID PAGE 1 04 PRINT REQUEST INTDATE: 1/28/04 PRINT TIME: 10:16:55 SCHEDULE DATES START: 1/28/04 COMPLETION: 1/28/04 188470 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: OAKWOOD CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code Task code: Facility ID Assigned Department: CS -CUSTOMER SERVICES CSCS SET UP NEW UTILITY ACCT SET OT-CUSTOMER SERVICE PREPARED 7/01/04, 12:01:55 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/01/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 3709 BRIDLE TRAILS CT SUBDIV: BRIDLE GATE ESTATES PH 1 TENANT, NBR: EXT GRNTD 90 DAYS 4-23-04 CONTRACTOR OAKWOOD CUSTOM HOMES PHONE (979) 690-1504 OWNER OCC CONSTRUCTION CORP PHONE PARCEL 159010-0102-0050 APPL NUMBER: 03-00001015 RESIDENTIAL, 1 UNIT DETACHED NEW PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 2/12/04 OC BLDG, FOUNDATION -SLAB TIME: 17:00 2/12/04 DP 02/12/2004 10:02 AM MALFORD ` after 4 if possible on 2/12/04 4� no strings B100 02 2/13/04 OC BLDG, FOUNDATION -SLAB TIME: 17:00 2/16/04 AP 02/13/2004 08:36 AM SSTANLEY setback per strings - slab ground @ left back B115 01 3/22/04 OC BLDG, FRAMING TIME: 17:00 3/23/04 AP 03/22/2004 08:57 AM SSTANLEY B130 01 3/24/04 DS BLDG, INSULATION TIME: 17:00 3/24/04 AP 03/24/2004 10:00 AM SSTANLEY late afternoon B125 01 7/01/04 BI BLDG, FINAL TIME: 17:00 07/01/2004 08:53 AM SSTANLEY -------------------------------------- COMMENTS AND NOTES ----------------------- `day �lc'G�a CITY OF COLLEGE STATION _ WORK 'QUEST REQ/JOB: WF0391130 / (L.01 CREW: LOCATION: 3709 BRIDLE TRAILS CT PAGE 1 Ab REQUEST DATE: 4/11/03 PRINT DATE: 4/11/03 PRINT,TIME: 15:54:32 SCHEDULE DATES START: 4/11/03 77845 COMPLETION: 4/11/03 GEN. LOC: COLLEGE STATION LOC ID: 188470 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: OAKWOOD CUSTOM HOMES-690-1504 ORIGIN: CUSTOMER -WALK IN USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE 4" SEWER / 3/4" WATER ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 4" SEWER / 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE BUILDING PERMIT c T OF CO EG . I COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00001015 Date 4/11/03 Property Address . . . . . . 3709 BRIDLE TRAILS CT Property ID . . 159010-0102-0050 R # . . . . . . . . . . . . . R106731 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . BRIDLE GATE ESTATES PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 160000 Owner ------------------------ Contractor OCC CONSTRUCTION CORP ------------------------ OAKWOOD CUSTOM HOMES PO BOX 9849 ALTON OFCZARZAK COLLEGE STATION TX 778427849 PO BOX 9849 COLLEGE STATION TX 77842 (979) 690-1504 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 HEATED AREA 2340.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 4.00 ---------------------------------------------------------------------------- SEWER TYPE PUBLIC Permit . . . . . . BUILDING PERMIT Additional desc . . LL Permit Fee . . . . 640.00 Plan Check Fee .00 Issue Date . . . . 4/11/03 Valuation . . . . 160000 Expiration Date . . 10/08/03 Qty Unit Charge Per Extension BASE FEE 460.00 60.00 3.0000 --------------- THOU BLDG, VAL 100001-500000 180.00 7------------------------------------------------------------ Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER -----------------------------------------� --- ------------------ BUILDING DEPT REPRESS ATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 03-00001015 Date 4/11/03 ---------------------------------------------------------------------------- Special Notes and Comments CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 000, BUILDING DEPT REPRESE TATIVE: APPLICANT://'�L� BUILDING PERMIT CITY OF COLLEGE STATIO 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number ---------------------------------------------------------------------------- . . . . . 03-00001015 Date 4/11/03 Other Fees . . . . . . . . . WATER TAP 3/4" CITY INSTL 400.00 Fee summary ----------------- Charged Paid Credited Due Permit Fee Total ---------- 640.00 ---------- 640.00 -------------------- .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1390.00 1390.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATIOI 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00001016 Date 4/11/03 Property Address . . . . . . 3709 BRIDLE TRAILS CT Property ID . . 159010-0102-0050 R. # . . . . . . . . . . . . . R106731 Application description . . . TEMP POLE Subdivision Name . . . . . . BRIDLE GATE ESTATES PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner ------------------------ Contractor OCC CONSTRUCTION CORP ------------------------ OAKWOOD CUSTOM HOMES PO BOX 9849 ALTON OFCZARZAK COLLEGE STATION TX 778427849 PO BOX 9849 COLLEGE STATION TX 77842 ---------------------------------------------------------------------------- (979) 690-1504 Permit . . . . . . TEMP POLE PERMIT Additional desc . . LL Permit Fee . . . . 20.00 Issue Date . . . . ---------------------------------------------------------------------------- 4/11/03 Valuation . . . . 0 Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged ----------------- Paid Credited Due ---------- Permit Fee Total 20.00 ------------------------------ 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 BUILDING DEPT REPRES NTATIVE: APPLICANT: dr 150 DD APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEG E-STATION.TX. US Fa Off— Use 0* DATE: APPLICATION TEMP POLE # ADDRESS/LOCATION: 3-704 A ;1.4Ir 7/2+4i%S e� �" LOT s' BLOCK Z- SUBDIVISION ,aj?i/)(E EsI¢TC BUSINESS/OWNER NAME: "14t0004 C, 4&rb.&l PHONE: f•4-% -;jz)� CONTRACTOR/HOMEOWNER: ,54--f r PHONE: CONTRACTOR ADDRESS: 4060 % S+ • l( tro�%pT S fa►�f/:a,, ��'���j�j ELECTRICIAN: �,¢,�,0�1 L�/EtTit�c PLUMBER: n T HVAC: �!eC 'jpa" GOOD CENTS (Residential only): c�Q�► CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: AII&V I~E STRUCTURE USE: �.vGror /w**/ HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD ) PROJECT REGISTRATION# EABPRJ VALUATION: $ �do� rvo V(T STOTAL AREA: TAP3 HEATED AREA: zo (Cost of Labor and Materials) PUBLIC SEWER SEPTIC/TREATMENT SYSTEM SEWER TAP: SIZE [rWATER TAP: SIZE OTHER TAP: SIZE &I -TEMP POLE GARAGE TYPE: SINGLE ATTACHED SIGNATURE OF APPLICANT: Y'e NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE FOUNDATION TYPE ROOF TYPE: DOUBLE E0I 'TRIPLE DETAA!4D I X-P0a0R Official Use Only Plans Examiner Zoning Official 0 k ments: YE or NO Energy Code Compliance Information v % Glazing of exterior walls I q to Insulation R value of exterior walls / 3 Insulation R value of ceiling 1 (flat areas) 3 0 Insulation R value of ceiling 2 (vaulted areas/no attic) I C? Glazing SHGC .12 U Glazing U-Factor - & 20 R value of ductwork 6 A/C SEER rating / 2— t T-9 3/4' 3709 BRIDLE TRXLS COURT LOT 5 BLOCK '-11 1/4u 3 03'1D15 Permit Number MECcheck Compliance Report 2000 IECC MECcheck Software Version 3.2 Release I Checked By/Date TITLE: NOTTINGHAM CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 09/ 19/02 DATE OF PLANS: 1/11/01 PROJECT INFORMATION: 3709 BRIDLE TRAILS COURT LOT 5, BLOCK 2 COMPANY INFORMATION: OAKWOOD CUSTOM HOMEBUILDERS, L.L.C. NOTES: NEW CONSTRUCTION COMPLIANCE: Passes Maximum UA = 921 Your Home = 768 16.6% Better Than Code Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 2147 30.0 0.0 75 Ceiling 2: Cathedral Ceiling (no attic) 193 19.0 0.0 10 Wall 1: Wood Frame, 16" o.c. 2419 13.0 0.0 161 Window 1: Metal Frame with Thermal Break, Double Pane with Low-E 338 0.670 226 Door 1: Solid 18 0.140 3 Door 2: Glass 100 0.170 17 Slab 1: Unheated, 0.0' insul. 265 0.0 276 Air Conditioner 1: Electric Central Air, 12 SEER Furnace 1: Forced Hot Air, 78 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 20 ECC requirements in MECcheck Version 3.2 Release Ib. r Builder/Designer Date Q Z MECcheck Inspection Checklist 2000 IECC MECcheck Software Version 3.2 Release lb DATE: 09/19/02 TITLE: NOTTINGHAM Bldg. Dept. �f Use [ ] [ ] [ ] [ ] [ ] [ ] Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: 1. Window 1: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.670 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 1: Solid, U-factor: 0.140 Comments: 2. Door 2: Glass, U-factor: 0.170 # Panes Frame Type Comments: Slab -On -Grade Floors: 1. Slab 1: Unheated, R-0 (uninsulated) I Comments: Thermal Break? [ ] Yes [ ] No Heating and Cooling Equipment: [ ] 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number [ ] 2. Furnace 1: Forced Hot Air, 78 AFUE or higher Make and Model Number [ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ J Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation. Materials Identification: Materials and equipment must be installed in accordint to the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values, glazing U-values, and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ) Cooling ducts with exterior insulation must be covered with a vapor retarder. [ J Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the I levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" kp Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)