HomeMy WebLinkAboutRES2003-01015JAN ZZ '04 01:59PM CERTIFIED COPY
P. i
4060 Highway 6 South
College Station, TX 77845
January 22, 2004
1101 Texas Avenue
College Station, TX 77845
Dear Mr, Sims:
This letter is in regards to 3709 Bridal Trails Court, Permit #03-00001015. The
original permit is dated April -11, 2003, however due to complications we were unable
to build this home until the present date. This has cause the permit to expire, We
are requesting an extension on this permit so that we can start the building process
on this lot.
If you have any questions regarding this request please contact our office at (979)
690-1504. Either Alton, or myself can help.
Thank you,
d
April M. Walters
Project Coordinator
Oakwood Custom Homebuilders, L.L.C.
CITY OF COLLEGE STATION .
BUILDING PERMIT
ISSUED TO
OAKWOOD CUSTOM HOMES
(CONTRACTOR/OW NER)
FOR THE CONSTRUCTION OF: Single -Family Residential
❑ ADDITION ® NEW ❑ REMODELING ❑ REPAIR
STREET
LOCATION: LOT.", 5 BLOCK: 2 ADDITION:
PERMIT NO. 03-1015. GATE OF ISSUE:
TEMP POLE PERMIT NO. 03-1016 L-CLCe �s �
IS TO I
R30
R19
.17
.67
6
12
NG CONSTRUCTION.
CITY OF COLLEGE STATION
WORK REQUEST
REQ/JOB: WF0490676 / 001 PROJECT:
CREW:
LOCATION: 3709 BRIDLE TRAILS CT
77845
GEN. LOC: COLLEGE STATION LOC ID
PAGE 1
04
PRINT REQUEST INTDATE: 1/28/04
PRINT TIME: 10:16:55
SCHEDULE DATES
START: 1/28/04
COMPLETION: 1/28/04
188470
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: OAKWOOD CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN
USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE
TEMP POLE PASSED
TEMP POLE PASSED
Category code
Task code:
Facility ID
Assigned Department:
CS -CUSTOMER SERVICES CSCS
SET UP NEW UTILITY ACCT SET
OT-CUSTOMER SERVICE
PREPARED 7/01/04, 12:01:55 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 7/01/04
------------------------------------------------------------------------------------------------
ADDRESS . : 3709 BRIDLE TRAILS CT SUBDIV: BRIDLE GATE ESTATES PH 1
TENANT, NBR: EXT GRNTD 90 DAYS 4-23-04
CONTRACTOR OAKWOOD CUSTOM HOMES PHONE (979) 690-1504
OWNER OCC CONSTRUCTION CORP PHONE
PARCEL 159010-0102-0050
APPL NUMBER: 03-00001015 RESIDENTIAL, 1 UNIT DETACHED NEW
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 2/12/04 OC BLDG, FOUNDATION -SLAB TIME: 17:00
2/12/04 DP 02/12/2004 10:02 AM MALFORD `
after 4 if possible on 2/12/04 4�
no strings
B100 02 2/13/04 OC BLDG, FOUNDATION -SLAB TIME: 17:00
2/16/04 AP 02/13/2004 08:36 AM SSTANLEY
setback per strings - slab ground @ left back
B115 01 3/22/04 OC BLDG, FRAMING TIME: 17:00
3/23/04 AP 03/22/2004 08:57 AM SSTANLEY
B130 01 3/24/04 DS BLDG, INSULATION TIME: 17:00
3/24/04 AP 03/24/2004 10:00 AM SSTANLEY
late afternoon
B125 01 7/01/04 BI BLDG, FINAL TIME: 17:00
07/01/2004 08:53 AM SSTANLEY
-------------------------------------- COMMENTS AND NOTES -----------------------
`day �lc'G�a
CITY OF COLLEGE STATION _
WORK 'QUEST
REQ/JOB: WF0391130 / (L.01
CREW:
LOCATION: 3709 BRIDLE TRAILS CT
PAGE 1
Ab REQUEST DATE: 4/11/03
PRINT DATE: 4/11/03
PRINT,TIME: 15:54:32
SCHEDULE DATES
START: 4/11/03
77845 COMPLETION: 4/11/03
GEN. LOC: COLLEGE STATION LOC ID: 188470
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: OAKWOOD CUSTOM HOMES-690-1504 ORIGIN: CUSTOMER -WALK IN
USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE
4" SEWER / 3/4" WATER
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
4" SEWER / 3/4" WATER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
BUILDING PERMIT c
T OF CO EG . I
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 03-00001015 Date 4/11/03
Property Address . .
. . . . 3709 BRIDLE TRAILS CT
Property ID
. . 159010-0102-0050
R # . . . . . . . . .
. . . . R106731
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . BRIDLE GATE ESTATES PH 1
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 160000
Owner
------------------------
Contractor
OCC CONSTRUCTION CORP
------------------------
OAKWOOD CUSTOM HOMES
PO BOX 9849
ALTON OFCZARZAK
COLLEGE STATION TX 778427849 PO BOX 9849
COLLEGE STATION TX 77842
(979) 690-1504
--------------------------
Structure Information -------------------------
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
HEATED AREA 2340.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.50
NUMBER OF BEDROOMS 4.00
----------------------------------------------------------------------------
SEWER TYPE PUBLIC
Permit . . . . . . BUILDING PERMIT
Additional desc . . LL
Permit Fee . . . .
640.00 Plan Check Fee .00
Issue Date . . . .
4/11/03 Valuation . . . . 160000
Expiration Date . .
10/08/03
Qty Unit Charge
Per Extension
BASE FEE 460.00
60.00 3.0000
---------------
THOU BLDG, VAL 100001-500000 180.00
7------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS WITHIN
20 FEET OF MECHANICAL EQUIPMENT
PROVIDE COMBUSTION AIR
FOR GAS FIRED APPLIANCES PER
-----------------------------------------� --- ------------------
BUILDING DEPT REPRESS ATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 03-00001015 Date 4/11/03
----------------------------------------------------------------------------
Special Notes and Comments
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
000,
BUILDING DEPT REPRESE TATIVE:
APPLICANT://'�L�
BUILDING PERMIT
CITY OF COLLEGE STATIO
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
3
Application Number
----------------------------------------------------------------------------
. . . . .
03-00001015
Date
4/11/03
Other Fees . . .
. . . . . .
WATER TAP 3/4"
CITY INSTL
400.00
Fee summary
-----------------
Charged
Paid
Credited
Due
Permit Fee Total
----------
640.00
----------
640.00
--------------------
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1390.00
1390.00
.00
.00
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATIOI
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . .
. . .
03-00001016 Date 4/11/03
Property Address . . .
. . .
3709 BRIDLE TRAILS CT
Property ID
. .
159010-0102-0050
R. # . . . . . . . . . .
. . .
R106731
Application description
. . .
TEMP POLE
Subdivision Name . . .
. . .
BRIDLE GATE ESTATES PH 1
Property Use . . . . .
. . .
RESIDENTIAL
Property Zoning . . . .
. . .
SINGLE FAMILY RESIDENTIAL
Application valuation .
. . .
0
Owner
------------------------
Contractor
OCC CONSTRUCTION CORP
------------------------
OAKWOOD CUSTOM HOMES
PO BOX 9849
ALTON OFCZARZAK
COLLEGE STATION TX
778427849
PO BOX 9849
COLLEGE STATION
TX 77842
----------------------------------------------------------------------------
(979) 690-1504
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . LL
Permit Fee . . . .
20.00
Issue Date . . . .
----------------------------------------------------------------------------
4/11/03
Valuation . . . .
0
Other Fees . . . . . .
. . .
TEMP ELECT POLE CONNECT
45.00
Fee summary Charged
-----------------
Paid Credited
Due
----------
Permit Fee Total
20.00
------------------------------
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
BUILDING DEPT REPRES NTATIVE:
APPLICANT:
dr
150 DD
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEG E-STATION.TX. US
Fa Off— Use 0*
DATE:
APPLICATION
TEMP POLE #
ADDRESS/LOCATION: 3-704 A ;1.4Ir 7/2+4i%S e�
�"
LOT s' BLOCK Z- SUBDIVISION ,aj?i/)(E EsI¢TC
BUSINESS/OWNER NAME: "14t0004 C, 4&rb.&l PHONE: f•4-% -;jz)�
CONTRACTOR/HOMEOWNER: ,54--f r PHONE:
CONTRACTOR ADDRESS: 4060 % S+ • l( tro�%pT S fa►�f/:a,, ��'���j�j
ELECTRICIAN: �,¢,�,0�1 L�/EtTit�c PLUMBER:
n T
HVAC: �!eC 'jpa" GOOD CENTS (Residential only): c�Q�►
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK: AII&V I~E
STRUCTURE USE: �.vGror /w**/
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD ) PROJECT REGISTRATION# EABPRJ
VALUATION: $ �do� rvo V(T STOTAL AREA: TAP3 HEATED AREA: zo
(Cost of Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP:
SIZE
[rWATER TAP:
SIZE
OTHER TAP:
SIZE
&I -TEMP POLE
GARAGE TYPE: SINGLE
ATTACHED
SIGNATURE OF APPLICANT: Y'e
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE
FOUNDATION TYPE
ROOF TYPE:
DOUBLE E0I 'TRIPLE
DETAA!4D I X-P0a0R
Official Use Only
Plans Examiner
Zoning Official
0
k
ments:
YE or NO
Energy Code Compliance Information
v
% Glazing of exterior walls I q to
Insulation R value of exterior walls / 3
Insulation R value of ceiling 1 (flat areas) 3 0
Insulation R value of ceiling 2 (vaulted areas/no attic) I C?
Glazing SHGC .12 U
Glazing U-Factor - & 20
R value of ductwork 6
A/C SEER rating / 2— t
T-9 3/4'
3709 BRIDLE TRXLS COURT
LOT 5 BLOCK
'-11 1/4u
3
03'1D15
Permit Number
MECcheck Compliance Report
2000 IECC
MECcheck Software Version 3.2 Release I Checked By/Date
TITLE: NOTTINGHAM
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 09/ 19/02
DATE OF PLANS: 1/11/01
PROJECT INFORMATION:
3709 BRIDLE TRAILS COURT
LOT 5, BLOCK 2
COMPANY INFORMATION:
OAKWOOD CUSTOM HOMEBUILDERS, L.L.C.
NOTES:
NEW CONSTRUCTION
COMPLIANCE: Passes
Maximum UA = 921
Your Home = 768
16.6% Better Than Code
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter R-Value
R-Value
U-Factor
UA
Ceiling 1: Flat Ceiling or Scissor Truss
2147
30.0
0.0
75
Ceiling 2: Cathedral Ceiling (no attic)
193
19.0
0.0
10
Wall 1: Wood Frame, 16" o.c.
2419
13.0
0.0
161
Window 1:
Metal Frame with Thermal Break, Double Pane with Low-E
338
0.670
226
Door 1: Solid
18
0.140
3
Door 2: Glass
100
0.170
17
Slab 1: Unheated, 0.0' insul.
265
0.0
276
Air Conditioner 1: Electric Central Air, 12 SEER
Furnace 1: Forced Hot Air, 78 AFUE
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building
plans, specifications, and other calculations submitted with the permit application. The proposed building has
been designed to meet the 20 ECC requirements in MECcheck Version 3.2 Release Ib.
r
Builder/Designer Date Q Z
MECcheck Inspection Checklist
2000 IECC
MECcheck Software Version 3.2 Release lb
DATE: 09/19/02
TITLE: NOTTINGHAM
Bldg.
Dept.
�f Use
[ ]
[ ]
[ ]
[ ]
[ ]
[ ]
Ceilings:
1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation
Comments:
Above -Grade Walls:
1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
1. Window 1: Metal Frame with Thermal Break, Double Pane with Low-E, U-factor: 0.670
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
1. Door 1: Solid, U-factor: 0.140
Comments:
2. Door 2: Glass, U-factor: 0.170
# Panes Frame Type
Comments:
Slab -On -Grade Floors:
1. Slab 1: Unheated, R-0 (uninsulated)
I Comments:
Thermal Break? [ ] Yes [ ] No
Heating and Cooling Equipment:
[ ] 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher
Make and Model Number
[ ] 2. Furnace 1: Forced Hot Air, 78 AFUE or higher
Make and Model Number
[ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
[ J Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate
air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation.
Materials Identification:
Materials and equipment must be installed in accordint to the manufacturer's installation instructions.
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values, glazing U-values, and cooling equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
[ ] Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at
less than 2 in. w.g. (500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ) Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ J Air filters are required in the return air system.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the
I levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature ( F)
Up to 1„
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4"
kp Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)