August 9, 2010
TO: RME Consulting Engineers (c/o Rabon Metcalf), via fax 764.0704
FROM: Matt Robinson, Staff Planner
SUBJECT: 1608 PARK PLACE (FP-REPLAT) - Final Plat
Staff reviewed the above-mentioned final plat as requested. The following page is a list
of staff review comments detailing items that need to be addressed. If all comments
have been addressed and the following information submitted by Monday, August 16,
10:00 a.m., your project will be placed on the next available Planning and Zoning
Commission meeting scheduled for, September 2, 7:00 p.m. in the City Hall Council
Chambers, 1,1101 Texas Avenue.
tom/ One (1) 24"x36" copy of the revised final plat,
t/ Nineteen (19) 11"x17" copies of the revised final plat:
Parkland Dedication in the amount of $2,021 must be submitted prior to
the filing of the final plat;
Z> l~-- One (1) Mylar original of the revised final plat (required after P&Z
approval); and
One (1) copy of the digital file of the final plat on diskette or e-mail to:
P&DS-Digital-Submittal@cstx.gov.
Upon receipt of the required documents for the Planning & Zoning meeting,. your project
will be considered formally filed with the City of College Station. Please note that if all
comments have not been addressed your project will not be scheduled for a Planning &
Zoning Commission meeting. Your project may be placed on a future agenda once all
the revisions have been made and the appropriate fees paid. Once your item has been
scheduled for the P&Z meeting, the agenda and staff report can be accessed at the
following web site on Monday the week of the P&Z meeting.
hftp://www.cstx.gov/pz
If you have any questions or need additional information, please call me at
979.764.3570.
Attachments: Staff review comments
cc. Charles E & Delores Thompson, via US Mail
Case file #10-00500161
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must
be explained in your next transmittal letter and `bubbled" on your plans. Any additional changes on
these plans that have not been pointed out to the City, will constitute a completely new review. 1 of 3
STAFF REVIEW COMMENTS NO.1
Project: 1608 PARK PLACE (FP-REPLAT) - 10-00500161
PLANNING
Please correct the scales. The drawing appears to be drawn at a 1" = 20' scale.
(Remove Ali Jaffar as the owner of the property. Charles E & Delores Thompson
appear to be the current owners.
an FYI, Parkland Dedication will only be required for the newly created lot.
t~V Correct Ownership & Dedication to "Lots 11R1 and 11R2, Block 1, F. S. Kapchinski
Subdivision".
5. Submit a copy of the calculation of the average lot width. The plat drawing shows
proposed lot widths as 52.13' compared to 51.52' in the variance request. Please
econcile. ~..a~ 1►~~~7~.
Provide corner markers between the two created lots.
61c.,7. Please note that any changes made to the plans, that have not been requested by
the City of College Station, must be explained in your next transmittal letter and
"bubbled" on your plans. Any additional changes on these plans that the City has not
been made aware of will constitute a completely new review.
b ~'-8. Please note that you may be required to submit paid tax certificates if they are not
current prior to the filing of your plat.
Reviewed by: Matt Robinson Date: 8/9/10
ENGINEERING COMMENTS NO. 1
There is a significant amount of fall from the street (Boardwalk Ct.) to and across the
proposed lot 11R2. With the presumable construction of a home on Lot 11R2 how
will grading and drainage be handled in order to assure that the existing adjacent
structures will not be adversely affected. A note needs to be added to the plat to
Adcd ress this concern. 6p-e- tts` e-
i i s development of the proposed lot taken into consideration with your latest
rainage report for the development of Boardwalk Ct?-6fEF A-TTj,r~ T79As "
41- fil~' How will lot 11 R2 sewer? L F..-'CEF..-~..,
Please elaborate on the note for the shed to be removed, as the shed should be
removed before any proposed development on lot 11 R1 or 11 R2.
5F ~4c-xe- -Ar
Reviewed by: Josh Norton Date: August 5, 2010
ELECTRICAL COMMENTS REQUIRING IMMEDIATE ATTENTION
1. All easements on site are existing. Electric facilities will be designed within existing
easements.
2. Developer may be responsible for locating easements on site to insure that electrical
infrastructure is installed within easement boundaries.
GENERAL ELECTRICAL COMMENTS
1. Developer installs conduit per CSU specs and design.
2. CSU will provide drawings for electrical installation.
3. Developer provides 30' of rigid or IMC conduit for riser poles. CSU installs riser.
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must
be explained in your next transmittal letter and "bubbled' on your plans. Any additional changes on
these plans that have not been pointed out to the City, will constitute a completely new review. 203
-FY
4. Developer will intercept existing conduit at designated transformers or other existing
devices and extend as required.
5. If conduit does not exist at designated transformer or other existing devices,
developer will furnish and install conduit as shown on CSU electrical layout.
6. Developer pours electric device pads or footings (i.e. transformers, pull boxes etc)
per CSU specs and design.
7. Developer installs pull boxes and secondary pedestals per CSU specs and design
(pull boxes and secondary pedestals provided by CSU).
8. Developer provides digital AutoCAD 2000 or later version of plat and / or site plan.
Email to:
g marti nez(&-cstx. oov.
9. Developer provides load data to CSU as soon as it is available to avoid construction
delays. Delivery time for transformers not in stock is approximately 40 weeks.
10. Final site plan must show all proposed electrical facilities necessary to provide
electrical service, i.e. transformer(s), pull box(es), switchgear(s), meter location and
conduit routing as designed by CSU.
11. To discuss any of the above electrical comments please contact Gilbert Martinez at
979.764.6255.
Reviewed by: Gilbert Martinez Date: 08.05.2010
GREENWAYS
1. No comments
Reviewed by: Venessa Garza Date: August 3, 2010
NOTE: Any changes made to the plans. that have not been requested by the City of College Station, must
be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on
these plans that have not been pointed out to the City, will constitute a completely new review. 3 of 3