HomeMy WebLinkAbout01-00500259- 00075380CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone (979) 764-3570 / Fax (979) 764-3496 MEMORANDUM December 10, 2001 TO: Larry Wells, Municipal Development Group, Via fax 693-4243 FROM: Bridgette George, Assistant Development Manager SUBJECT: NANTUCKET PH 2 BLK 7 (FP-MINOR) - Final Plat Staff reviewed the above-mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by Monday, December 17, 10:00 a.m. to be placed on the next available Planning and Zoning Commission meeting scheduled for January, 3, 2002, 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue. Ten (10) copies of the revised final plat; and, One (1) Mylar original of the revised final plat with the appropriate signatures. One (1) copy of the digital file of the final plat on diskette or e-mail to nmanhart@ci.college-station.tx.us If you have any questions or need additional information, please call me at 764-3570. Attachments: Staff review comments cc: W. L. Scrutchfield, 2111 Arrington Road, College Station, TX, 77840 Case file #1-500259 Home of Texas A&M University STAFF REVIEW COMMENTS NO. 1 Project: NANTUCKET PH 2 BLK 7 (FP-MINOR)-FINAL PLAT - MINOR OR AMENDING (1-500259) ENGINEERING This is should be considered a Vacating Plat. 1. Please label in title block "Vacating and Final Plat". By vacating, the easements will truly be erased. By re-platting, easements are still in place unless one goes through the abandonment process in addition to the re-plat. 2. Due to the fact that easements are being affected, this is not a Minor Plat. This plat will go to the P&Z. It should be a consent item. Please change the certificate from staff approval to P&Z approval. 3. Please change Original Subdivision to Vacating Plat and change Resubdivision to Final Plat. 4. Please include a Certificate for the City Engineer. 5. Please check your survey measurements. I can not get the survey to close. 6. On the lot line between the 2R lot and Lot 1, please change to read North and West rather than North and East. 7. Please be aware that the County will need to see letters from the various utility companies (TXU, BTU, etc) stating their willingness to vacate this easement before action will be taken on the plat. The City can process the plat without this letter. Reviewed by: Spencer Thompson Date: December 6, 2001 ELECTRICAL 1. This is in ETJ. Reviewed by: Ronnie Bolin Date: 12/10/01 Home of Texas A&M University