Loading...
HomeMy WebLinkAbout10-00500180- 00075146i CITY OF COLLEGE STATION Preliminary Plat for The Ledbetter Subdivision 10-00500180 SCALE: 3 lots on 45.56 acres LOCATION: 1404 Sebesta Road, generally located southwest of the intersection of Sebesta Road and Foxfire Drive ZONING: A-O Agricultural Open, A-OR Rural Residential Subdivision, and R-1 Single-Family Residential n APPLICANT: Rick Lemmons, Oldham Goodwin Group PROJECT MANAGER: Jennifer Prochazka, Senior Planner joochazka@cstx.gov I C ; RECOMMENDATION: Approval Planning & Zoning Commission October 5, 2010 Page 1 of 4 Planning & Zoning Commission Page 2 of 4 October 5, 2010 DEVELOPMENT HISTORY Annexation: A small portion (less than a quarter of an acre) of the subject property was annexed with adjacent properties in 1971. The majority of the property was annexed in 1977. In 1992, Lot 1, Block 6 of the Foxfire Subdivision was annexed with the larger subdivision. Zoning: A-O Agricultural Open and R-1 Single-Family Residential (upon annexations). Lot 1, Block 6 of the Foxfire Subdivision was zoned A-OR Rural Residential Subdivision in11998. Site development: The property is largely undeveloped, 6h several small residential structures located on the southwest portion of the property. Lot 1, lock 6 of the Foxfire Subdivision is currently developed as Holy Cross Lutheran Church. COMMENTS Water: The subject tract is located adjacent to a 12-inch water main that runs along Sebesta Road as well as a 12-inch water main that runs along Foxfire Drive. Sewer: The subject tract is located adjacent to two separate 8-inch sanitary sewer mains located along the northern and southern property boundaries. Off-site Easements: None known at this time. Drainage: The subject tract is located in the Carter's Creek Drainage Basin. Development of the subject tract will be required to meet the City's minimum storm water design guidelines. Flood Plain: The southeast property corner does encroach into a small amount of Zone AE, FEMA regulated Special Flood Hazard Area. Greenways: N/A Pedestrian Connectivity: Sidewalks are existing on Sebesta Road in this area. Sidewalks are proposed with the extension of Pavilion Avenue. Bicycle Connectivity: Bike lanes are existing on Sebesta Road in this area. Bike lanes are proposed with the extension of Pavilion Avenue. Streets: The City's Thoroughfare Plan shows Sebesta Road as a 2-Lane Minor Collector (77-foot right-of-way) northeast of its intersection with Pavilion Avenue and as a 2-Lane Major Collector (77-foot right-of-way) southwest of its intersection with Pavilion Avenue. The existing right-of-way width for Sebesta Road is . The proposed Preliminary Plat includes right-of-way dedication of approximately half of the deficient right-of-way width for Sebesta Road. Planning & Zoning Commission Page 3 of 4 October 5, 2010 The Thoroughfare Plan includes the extension of Pavilion Avenue (77' right-of-way) south of Sebesta Road through the subject property as a 2-Lane Major Collector. Oversize Request: None requested at this time. Parkland Dedication Fees: N/A Impact Fees: N/A REVIEW CRITERIA 1. Compliance with Comprehensive Plan and Unified Development Ordinance: The Comprehensive Plan Land Use and Character Map designates the majority of the property as General Suburban. A small portion of the property, currently developed as Holy Cross Lutheran Church, is designated as Estate. A small portion of the property at the southeastern corner is designated as Natural Areas - Reserved and is designated as 100- year FEMA floodplain. The City's Thoroughfare Plan shows Sebesta Road as a 2-Lane Minor Collector northeast of its intersection with Pavilion Avenue and as a 2-Lane Major Collector southwest of its intersection with Pavilion Avenue. The proposed Preliminary Plat includes right-of-way dedication of approximately half of the deficient right-of-way width for Sebesta Road. The Thoroughfare Plan includes the extension of Pavilion Avenue south of Sebesta Road through the subject property as a 2-Lane Major Collector. The majority of the property is zoned A-O Agricultural Open, requiring a minimum 5-acre lot size. The proposed Preliminary Plat is in compliance with all zoning district requirements. 2. Compliance with Subdivision Regulations: The proposed Preliminary Plat is in compliance with the City's subdivision regulations contained in the Unified Development Ordinance. STAFF RECOMMENDATION Staff recommends approval. SUPPORTING MATERIALS 1. Application 2. Copy of Preliminary Plat (provided in packet) Planning & Zoning Commission Page 4 of 4 October 5, 2010