HomeMy WebLinkAboutapplication (2)CITY OF COLLEGE STATION
Planning, 13cve1op ent Services
FOR MSEINtY
P&Z CASE NO.: `
DATE SUBMITTED:
FINAL PLAT APPLICATION
eqt',I -
(Check one) ❑ Minor ❑ Amending [Final ❑ Vacating ❑ Re lat
($300.00) ($300.00) ($400.00 p
($400.00) ($600.00)'
'Includes public hearing fee
Is this plat in the ETJ? zYes ❑ No Is this plat Commercial ❑ or Residential P-111
MINIMUM SUBMITTAL REQUIREMENTS:
$300 - $600 Filing Fee (see above) NOTE: Multiple Sheets - $55.00 per additional sheet
Nj, $100 Variance Request to Subdivision Regulations (if applicable)
$200 Development Permit Application Fee (if applicable). tyW,fk pHme 4
> $600.00 Infrastructure Inspection Fee (applicable if any pu InfrastructLire is being constructed)
7 Application completed in full. This application form provided by the City of College Station must be used
and may not be adjusted or altered. Please attach pages if additional information is provided.
Fourteen (14) folded copies of plat. (A signed Mylar original must be submitted after approval.)
N Copy of original deed restrictions/covenants for replats (if applicable).
Title report for property current within ninety (90) days or accompanied by a Nothing Further Certificate
current within ninety (90) days. The report must include applicable information such as ownership, liens,
/encumbrances, etc.
Paid tax certificates from City of College Station, Brazos County and College Station I.S.D.
Proof of parkland dedication consideration by the Parks & Recreation Board or Parks & Recreation
Department (if applicable). PP vi ?_<5-04
~,lA copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
✓ Two (2) copies of public infrastructure plans associated with this plat (if applicable).
NOTE: A mylar of the approved preliminary plat must be on file before a final plat application will be
considered complete. If the mylar is submitted with the final plat application, it shall be considered a
submittal for the preliminary plat project and processed and reviewed as such. Until the mylar has been
confirmed by staff to be correct, the final plat application will be considered incomplete.
Date of Optional Preapplication Conference:
NAME OF SUBDIVISION M CD_GM- S5[) r uI Stout bNAS1= CIA
SPECIFIED LOCATION OF PROPOSED SUBDIVISION (Lot & Block)
APPLICANT/PROJECT tM~ANAGER'S INFORMATION (Primary Contact for the Project):
Name LViL !l(wa'0&0f'1J i L-A. KEar- (434
Street Address •,3; ]~t}PuGV J441T-_ cc. /DKW~ City (666X5!= _57,f7-,,✓
State -Ty Zip Code 77Fyv E-Mail Address (t L 422 Gq
Phone Number el - 7 - ?74 3 Fax Number y • 7<<t 7 i
PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for multiple
owners): l
Name iW ~ 126_/i ,Ke5 - ~S Gfcl
Street Address q60 ~o:~< ^ers Ave, City
State Tk Zip Code ?,P7e, i E-Mail Address i
Phone Number _ Sid ~6 ~ ~Sy 3a Fax Number f h - ~i - r-iLff
1 of 6
04/20/09 MON 15:43 FAX 5124786498 PRUD OWENS REALTY
8002
ARCHITECT OR ENGINEER'S INFORMATION:
Name _ COAL, fl-vat.o /a-ffrn rj Lam.
Street Address &3.3 jag 'M('m tk a't-- AKw x city
Rate _ ?-C zip Code 77PYa E-Mail Address k(gea Il~ cd Ibss,
Phone Number 9 • ?!y 774 3 Fax Number 12f.
7~4~• 7 7S~
Do any deed iestrictlons or covenants exist for this property? Yes No ✓
Is there a temporary blanket easement on this property? If so, please provide the Volume and Page #
Acreage Total Property t3, da?6 Total # of Lots Sb R-O-WAcreage D. 047
Existing Use: _ Uaiaw 4- Proposed Use; (V-5; drH frg l
Number of Lots By Zoning District S~ i A-0 Average Acreage Of Each Residentlal Lot By Zoning District:
IJ3 i -l3 / I 1
Floodplain Acreage N _
A statement addressing any differences between the Final Plat and Preliminary Plat (if applicable):
NA
Requested Variances To Subdivision Regulations & Reason For Same:
Requested Oversize Participation:
Total Linear Footage of
Proposed Public:
190 Streets
12.7 Sidewalks
WOO Sanitary Sewer Lines
8a 7 Water Lines
Channels
Lf my Storm Sewers
Bike Lanes I Paths
Parkland Dedication due prior to filing the Final Plat:
ACREAGE:
No. of acres to be dedicated + $ development fee
No. of acres in floodplain
No. of acres in detention
No. of acres in greenways
OR
FEE IN LIEU OF LAND:
No. of SF Dwelling Units X $ = $
(date) Approved by Parks & Recreation Advisory Board
NOTE: DIGITAL COPY OF PLAT MUST BE SUBMITTED PRIOR TO FILING.
The applicant has prepared this application and certifies that the facts stated herein and exhibits affached'hereto are UU9,
correct, and complete. IF THIS APPLICATION IS FILED BY ANYONE OTHER THAN THE OWNER OF THE
PROPERTY, this application must be accompanied by a power of attorney statement from the owner. if there is more
than one owner, all owners must sign ft application or the power of attorney. If the owner is a company, the application
must be accompanied by proof of authority for the company's representative to sign the application on its behalf. LIEN
HOLDERS identified in the title report are also considered owners and the appropriate signatures must be provided as
des a e
vie& f / i 4jp,_r
Signature d Title Date
2 of6
04/20/09 MON 15:43 FAX 5124786498 PRUD OWENS REALTY
SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION
Application is hereby made for the following development specific sitetwaterway alterations:
hereby acknowledge or affirm that
IM 003
The information and c holusions contained in the above plans and supporting documents comply with the current
requirements of the City of College Station, Texas City Code, Chapter 13 and its associated Drainage Policy and Design
Standards. As a condition of approval of this permit application, I agree to construct the improvements proposed in this
application according to these documents and the requirements of Chapter 13 of the College Station City Code.
M AiN 5 eZ~T c5- G 5.
Prope a Contractor
CERTIFICA NS: (for proposed alterations within designated flood hazard areas.)
A.1, e» a 2 a certify that any nonresidential structure on or proposed to be on this site
as part of this application is designated to prevent damage to the structure or its contents as a result of flooding from the
100 y storm.
ZI /20%4
Engineer Da e
13. I, - den f 14 z ig certify that the finished floor elevation of the lowest floor. Including any
basement, of any residential structure, proposed as part of this application is at or above the base flood elevation
estabji ed in the I test Federal Insurance Administration Flood Hazard Study and maps, as amended.
Engineer Date
C. I, l&2 a certify that the alterations or development covered by this permit shall
not diminish the flood-carrying capacity of the waterway adjoining or crossing this permitted site and that such alterations
or development are consistent with requirements of the City of College Station City Code, Chapter 13 concerning
en menu floodways and of floodway fringes.
c. I;t /Z O/09
Engineer Date
D.1, r►, 7' &Z Q , do certify that the proposed alterations do not ralse the level of the 100
year floo above elevation established in the latest Federal Insurance Administration Flood Hazard Study.
f/ L/ /W 9
Engineer Date
Conditions or comments as part of approval:
In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to
insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage
facilities, All development shall be in accordance with the plans and specifications submitted to and approved by the City
Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall
apply.
3 of 6
or'l*"
Crry OF COLLEGE STATION
Xwflirg is Derr kP.Jmr srn:ie a
SUBMIT APPLICATION AND THIS
LIST CHECKED OFF WITH 13
FOLDED COPIES OF PLAT FOR REVIEW
FINAL PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
(Requirements based on field survey and marked by monuments and markers.)
1. ❑ 2. Paid tax certificates.
3. Drawn on 24" x 36" sheet to scale of 100' per inch.
[g" 4. Vicinity map which includes enough of surrounding area to show general location of subject
property in relationship to College Station and its City Limits. No scale required but include north
arrow.
5. Titi Block with the following information:
Name and address of subdivider, recorded owner, planner, engineer and surveyor.
Proposed name of subdivision. (Subdivision name & street names will be approved
through Brazos County 911.)
Date of preparation.
Engineer's scale in feet.
Total area intended to be developed.
6. North Arrow.
7. Subdivision boundary indicated by heavy lines.
r
8. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or
larger.
❑ 9. All applicable certifications based on the type of final plat.
Ownership and Dedication
Surveyor and/or Engineer
Engineer (and City Planner, if a minor plat)
lanning and Zoning Commission (delete if minor plat)
Brazos County Clerk
Brazos County Commissioners Court Approval (ETJ Plats only)
~R 10. If submitting a replat where there are existing improvements, submit a survey of the subject
property showing the improvements to ensure that no encroachments will be created.
4A 11. If using private septic systems, add a general note on the plat that no private sewage facility may
be installed on any lot in this subdivision without the issuance of a license by the Brazos County
Health Unit under the provisions of the private facility regulations adopted by the Commissioner's
Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code.
12. Location of the 100-Year Floodplain and floodway, if applicable, according to the most recent
available data.
13. Lot corner markers and survey monuments (by symbol) and clearly tied to basic survey data.
14. Matches the approved preliminary plat.
4of6
❑ 15. The location and description with accurate dimensions, bearings or deflection angles and radii,
area, center angle, degree of curvature, tangent distance and length of all curves for all of the
following: (Show existing items that are intersecting or contiguous with the boundary of or forming
a boundary with the subdivision, as well as, those within the subdivision).
Existing,. Proposed
LK Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp
turn around unless they are shorter than 100 feet.
Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s
sufficient to meet Thoroughfare Plan.)
Ell*" E~ Street offsets and/or intersection angles meet ordinance.
0 14 QA Alleys.
Easements.
[v]~ A number or letter to identify each lot or site and each block (numbered sequentially).
PIT, Parkland dedication/greenbelt area/park linkages. All proposed dedications must be
reviewed by the Parks and Recreation Board and documentation of their
recommendation provided prior to being scheduled for P & Z Commission consideration.
It is the responsibility of the applicant to provide documentation from the Parks
Department of the Board's recommendation.
❑ 16. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed
by a Licensed Texas Professional Engineer that include the following:
Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall
street, alley and/or sidewalk layout of the subdivision. (may be combined with other
utilities).
❑ Sewer Design Report. pr~o~c
Sanitary sewer plan and profile showing depth and grades. One sheet must show the
overall sewer layout of the subdivision. (Utilities of sufficient size/depth to meet the utility
master plan and any future growth areas.)
❑ Water Design Report and/or Fire Flow Report. Qrr;«~.s1y y
Ei~Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing
depth and grades. One sheet must show the overall water layout of the subdivision.
(Utilities of sufficient size/depth to meet the utility master plan and any future growth
areas.)
Q` Storm drainage system plan with contours, street profile, inlets, storm sewer and
drainage channels, with profiles and sections. Drainage and runoff areas, and runoff
based on 5, 10, 25, 50 and 100 year rain intensity. Detailed drainage structure design,
channel lining design & detention if used. One sheet must show the overall drainage
layout of the subdivision.
Lid Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E.
❑ Drainage Report with a Technical Design Summary. Pke'sz q
Erosion Control Plan (must be included in construction plans).
17. All off-site easements necessary for infrastructure construction must be shown on the final plat with
a volume and page listed to indicate where the separate instrument easements were filed.
Separate instrument easements must be executed prior to being scheduled for P&Z Commission
consideration.
❑ 18. Are there impact fees associated with this development? ❑ Yes E No
Impact fees for R-1, R-2, & R-3 zoned final plats, must be paid prior to filing.
❑ 19. Will any construction occur in TxDOT rights-of-way? ❑ Yes 0"'N' 0
If yes, TxDOT permit must be submitted along with the construction documents.
5of6
NOTE: 1. We will be requesting the corrected Final Plat to be submitted in digital form if available prior to
filing the plat at the Courthouse.
2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted
prior to issuance of a development permit.
6of6