Loading...
HomeMy WebLinkAboutapplication (2)CITY OF COLLEGE STATION Planning, 13cve1op ent Services FOR MSEINtY P&Z CASE NO.: ` DATE SUBMITTED: FINAL PLAT APPLICATION eqt',I - (Check one) ❑ Minor ❑ Amending [Final ❑ Vacating ❑ Re lat ($300.00) ($300.00) ($400.00 p ($400.00) ($600.00)' 'Includes public hearing fee Is this plat in the ETJ? zYes ❑ No Is this plat Commercial ❑ or Residential P-111 MINIMUM SUBMITTAL REQUIREMENTS: $300 - $600 Filing Fee (see above) NOTE: Multiple Sheets - $55.00 per additional sheet Nj, $100 Variance Request to Subdivision Regulations (if applicable) $200 Development Permit Application Fee (if applicable). tyW,fk pHme 4 > $600.00 Infrastructure Inspection Fee (applicable if any pu InfrastructLire is being constructed) 7 Application completed in full. This application form provided by the City of College Station must be used and may not be adjusted or altered. Please attach pages if additional information is provided. Fourteen (14) folded copies of plat. (A signed Mylar original must be submitted after approval.) N Copy of original deed restrictions/covenants for replats (if applicable). Title report for property current within ninety (90) days or accompanied by a Nothing Further Certificate current within ninety (90) days. The report must include applicable information such as ownership, liens, /encumbrances, etc. Paid tax certificates from City of College Station, Brazos County and College Station I.S.D. Proof of parkland dedication consideration by the Parks & Recreation Board or Parks & Recreation Department (if applicable). PP vi ?_<5-04 ~,lA copy of the attached checklist with all items checked off or a brief explanation as to why they are not. ✓ Two (2) copies of public infrastructure plans associated with this plat (if applicable). NOTE: A mylar of the approved preliminary plat must be on file before a final plat application will be considered complete. If the mylar is submitted with the final plat application, it shall be considered a submittal for the preliminary plat project and processed and reviewed as such. Until the mylar has been confirmed by staff to be correct, the final plat application will be considered incomplete. Date of Optional Preapplication Conference: NAME OF SUBDIVISION M CD_GM- S5[) r uI Stout bNAS1= CIA SPECIFIED LOCATION OF PROPOSED SUBDIVISION (Lot & Block) APPLICANT/PROJECT tM~ANAGER'S INFORMATION (Primary Contact for the Project): Name LViL !l(wa'0&0f'1J i L-A. KEar- (434 Street Address •,3; ]~t}PuGV J441T-_ cc. /DKW~ City (666X5!= _57,f7-,,✓ State -Ty Zip Code 77Fyv E-Mail Address (t L 422 Gq Phone Number el - 7 - ?74 3 Fax Number y • 7<<t 7 i PROPERTY OWNER'S INFORMATION (ALL owners must be identified. Please attach an additional sheet for multiple owners): l Name iW ~ 126_/i ,Ke5 - ~S Gfcl Street Address q60 ~o:~< ^ers Ave, City State Tk Zip Code ?,P7e, i E-Mail Address i Phone Number _ Sid ~6 ~ ~Sy 3a Fax Number f h - ~i - r-iLff 1 of 6 04/20/09 MON 15:43 FAX 5124786498 PRUD OWENS REALTY 8002 ARCHITECT OR ENGINEER'S INFORMATION: Name _ COAL, fl-vat.o /a-ffrn rj Lam. Street Address &3.3 jag 'M('m tk a't-- AKw x city Rate _ ?-C zip Code 77PYa E-Mail Address k(gea Il~ cd Ibss, Phone Number 9 • ?!y 774 3 Fax Number 12f. 7~4~• 7 7S~ Do any deed iestrictlons or covenants exist for this property? Yes No ✓ Is there a temporary blanket easement on this property? If so, please provide the Volume and Page # Acreage Total Property t3, da?6 Total # of Lots Sb R-O-WAcreage D. 047 Existing Use: _ Uaiaw 4- Proposed Use; (V-5; drH frg l Number of Lots By Zoning District S~ i A-0 Average Acreage Of Each Residentlal Lot By Zoning District: IJ3 i -l3 / I 1 Floodplain Acreage N _ A statement addressing any differences between the Final Plat and Preliminary Plat (if applicable): NA Requested Variances To Subdivision Regulations & Reason For Same: Requested Oversize Participation: Total Linear Footage of Proposed Public: 190 Streets 12.7 Sidewalks WOO Sanitary Sewer Lines 8a 7 Water Lines Channels Lf my Storm Sewers Bike Lanes I Paths Parkland Dedication due prior to filing the Final Plat: ACREAGE: No. of acres to be dedicated + $ development fee No. of acres in floodplain No. of acres in detention No. of acres in greenways OR FEE IN LIEU OF LAND: No. of SF Dwelling Units X $ = $ (date) Approved by Parks & Recreation Advisory Board NOTE: DIGITAL COPY OF PLAT MUST BE SUBMITTED PRIOR TO FILING. The applicant has prepared this application and certifies that the facts stated herein and exhibits affached'hereto are UU9, correct, and complete. IF THIS APPLICATION IS FILED BY ANYONE OTHER THAN THE OWNER OF THE PROPERTY, this application must be accompanied by a power of attorney statement from the owner. if there is more than one owner, all owners must sign ft application or the power of attorney. If the owner is a company, the application must be accompanied by proof of authority for the company's representative to sign the application on its behalf. LIEN HOLDERS identified in the title report are also considered owners and the appropriate signatures must be provided as des a e vie& f / i 4jp,_r Signature d Title Date 2 of6 04/20/09 MON 15:43 FAX 5124786498 PRUD OWENS REALTY SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION Application is hereby made for the following development specific sitetwaterway alterations: hereby acknowledge or affirm that IM 003 The information and c holusions contained in the above plans and supporting documents comply with the current requirements of the City of College Station, Texas City Code, Chapter 13 and its associated Drainage Policy and Design Standards. As a condition of approval of this permit application, I agree to construct the improvements proposed in this application according to these documents and the requirements of Chapter 13 of the College Station City Code. M AiN 5 eZ~T c5- G 5. Prope a Contractor CERTIFICA NS: (for proposed alterations within designated flood hazard areas.) A.1, e» a 2 a certify that any nonresidential structure on or proposed to be on this site as part of this application is designated to prevent damage to the structure or its contents as a result of flooding from the 100 y storm. ZI /20%4 Engineer Da e 13. I, - den f 14 z ig certify that the finished floor elevation of the lowest floor. Including any basement, of any residential structure, proposed as part of this application is at or above the base flood elevation estabji ed in the I test Federal Insurance Administration Flood Hazard Study and maps, as amended. Engineer Date C. I, l&2 a certify that the alterations or development covered by this permit shall not diminish the flood-carrying capacity of the waterway adjoining or crossing this permitted site and that such alterations or development are consistent with requirements of the City of College Station City Code, Chapter 13 concerning en menu floodways and of floodway fringes. c. I;t /Z O/09 Engineer Date D.1, r►, 7' &Z Q , do certify that the proposed alterations do not ralse the level of the 100 year floo above elevation established in the latest Federal Insurance Administration Flood Hazard Study. f/ L/ /W 9 Engineer Date Conditions or comments as part of approval: In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities, All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply. 3 of 6 or'l*" Crry OF COLLEGE STATION Xwflirg is Derr kP.Jmr srn:ie a SUBMIT APPLICATION AND THIS LIST CHECKED OFF WITH 13 FOLDED COPIES OF PLAT FOR REVIEW FINAL PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LIMITED TO THE FOLLOWING: (Requirements based on field survey and marked by monuments and markers.) 1. ❑ 2. Paid tax certificates. 3. Drawn on 24" x 36" sheet to scale of 100' per inch. [g" 4. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. 5. Titi Block with the following information: Name and address of subdivider, recorded owner, planner, engineer and surveyor. Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) Date of preparation. Engineer's scale in feet. Total area intended to be developed. 6. North Arrow. 7. Subdivision boundary indicated by heavy lines. r 8. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. ❑ 9. All applicable certifications based on the type of final plat. Ownership and Dedication Surveyor and/or Engineer Engineer (and City Planner, if a minor plat) lanning and Zoning Commission (delete if minor plat) Brazos County Clerk Brazos County Commissioners Court Approval (ETJ Plats only) ~R 10. If submitting a replat where there are existing improvements, submit a survey of the subject property showing the improvements to ensure that no encroachments will be created. 4A 11. If using private septic systems, add a general note on the plat that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioner's Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code. 12. Location of the 100-Year Floodplain and floodway, if applicable, according to the most recent available data. 13. Lot corner markers and survey monuments (by symbol) and clearly tied to basic survey data. 14. Matches the approved preliminary plat. 4of6 ❑ 15. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as well as, those within the subdivision). Existing,. Proposed LK Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp turn around unless they are shorter than 100 feet. Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to meet Thoroughfare Plan.) Ell*" E~ Street offsets and/or intersection angles meet ordinance. 0 14 QA Alleys. Easements. [v]~ A number or letter to identify each lot or site and each block (numbered sequentially). PIT, Parkland dedication/greenbelt area/park linkages. All proposed dedications must be reviewed by the Parks and Recreation Board and documentation of their recommendation provided prior to being scheduled for P & Z Commission consideration. It is the responsibility of the applicant to provide documentation from the Parks Department of the Board's recommendation. ❑ 16. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed by a Licensed Texas Professional Engineer that include the following: Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall street, alley and/or sidewalk layout of the subdivision. (may be combined with other utilities). ❑ Sewer Design Report. pr~o~c Sanitary sewer plan and profile showing depth and grades. One sheet must show the overall sewer layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) ❑ Water Design Report and/or Fire Flow Report. Qrr;«~.s1y y Ei~Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing depth and grades. One sheet must show the overall water layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) Q` Storm drainage system plan with contours, street profile, inlets, storm sewer and drainage channels, with profiles and sections. Drainage and runoff areas, and runoff based on 5, 10, 25, 50 and 100 year rain intensity. Detailed drainage structure design, channel lining design & detention if used. One sheet must show the overall drainage layout of the subdivision. Lid Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E. ❑ Drainage Report with a Technical Design Summary. Pke'sz q Erosion Control Plan (must be included in construction plans). 17. All off-site easements necessary for infrastructure construction must be shown on the final plat with a volume and page listed to indicate where the separate instrument easements were filed. Separate instrument easements must be executed prior to being scheduled for P&Z Commission consideration. ❑ 18. Are there impact fees associated with this development? ❑ Yes E No Impact fees for R-1, R-2, & R-3 zoned final plats, must be paid prior to filing. ❑ 19. Will any construction occur in TxDOT rights-of-way? ❑ Yes 0"'N' 0 If yes, TxDOT permit must be submitted along with the construction documents. 5of6 NOTE: 1. We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat at the Courthouse. 2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted prior to issuance of a development permit. 6of6