HomeMy WebLinkAbout00-00000212- 00073957CITY OF COLLEGE STATION
DEVELOPMENT SERVICES
1101 Texas Avenue South, PO Box 9960
College Station, Texas 77842
Phone (979) 764-3570 / Fax (979) 764-3496
MEMORANDUM
November 16, 2000
TO: Garrett Engineering, Via fax 846-3094
FROM: Bridgette George, Asst. Development Coordinator s
SUBJECT: RegencySouth - fYti dFlat
Staff reviewed the above-mentioned final plat as requested. The following page is a list of staff
review comments detailing items that need to be addressed. Because of the nature of this
replat, this item will be scheduled for a public hearing. Please address the comments and
submit the following information by Monday, November 27, 10:00 a.m. to be placed on the
next available Planning and Zoning Commission meeting scheduled for December 7, 2000,
7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue.
Final Plat application;
$100 Final Plat application fee;
Paid tax certificates;
Two (2) complete sets of Construction documents;
Ten (10) copies of the revised final plat; and,
The Mylar original of the revised final plat with the owner's signature.
All of the above items must be submitted prior to the filing of the final plat at the Brazos
Country Courthouse. If you have any questions or need additional information, please call me
at 764-3570.
Attachments: Staff review comments
cc: Glenn Thomas, Via fax 690-7118
Case file #00-212
Home of Texas A&M University
STAFF REVIEW COMMENTS No. 1
Project: REGENCY SOUTH (FP)-FINAL PLAT (00-212)
PLANNING
1. Show location of the knox box gate across the connector drive.
2. List the PDD rezoning requirements on the plat.
Reviewed by: Jessica Jimmerson Date: 11-16-00
ENGINEERING
1. An application is due with a $100.00 fee.
2. Paid tax certificates are necessary.
3. Please show graphically, by reference notes, or by legend, the lot corner
markers (I.E. iron pins) and survey monuments (I.E. bench marks) and
clearly tie to the survey data.
4. According to the original mylar Final Replat of Regency South, dated July
1983, that we have on file, the bearing N 41 41' 18" W - 116.0 should be
N 40 41' 18" W- 116.0.
5. S 43 13' 15" W - 6.70 appears to be a typographical error. It should be
6. S 43 13' 15" E - 6.70.
7. The measurements of 1.85 and 1.72, within the cul-de-sac, need a
bearing or curve data.
8. Show us how Lots 5R through 9R will be serviced by sanitary sewer.
Please submit construction documents showing plan, profile, depths and
grades.
9. Lots R8 and R10 appear to be a typographical error. It should be 8R and
10R.
10. Please submit construction documents showing the drainage plan and an
erosion control plan.
11. Off-site improvements will have to be made through Longmire Park to
assure proper flow without blockage in the drainage path. Longmire Park
is City property overseen by the Parks and Recreation Department. An
off-site easement necessary for this infrastructure construction must be
filed as a separate instrument prior to or concurrent with this replat and
shown by volume and page on the replat.
12. We will be requesting the corrected plat to be submitted in digital form if
available prior to filing the plat at the Courthouse.
Reviewed by: Thomas V. Vennochi Jr. Date: 11/16/00
NOTE: Any changes made to the plans, that have not been requested by the
City of College Station, must be explained in your next transmittal letter and
"bubbled" on your plans. Any additional changes on these plans that have not
been pointed out to the City will constitute a completely new review.
J:\PZTEXT\PZ03930.DOC Page 1 of 2
12/18/00
CITY OF COLLEGE STATION
DEVELOPMENT SERVICES
1101 Texas Avenue South, PO Box 9960
College Station, Texas 77842
Phone (979) 764-3570 / Fax (979) 764-3496
MEMORANDUM
December 19, 2000
TO: Garrett Engineering, Via fax 4Q.Q - '~4~ - 3 l `
FROM: Bridgette George, Asst. Development Review Manage ~y
SUBJECT: Regency South - FinalPlat J
Staff reviewed the above-mentioned final plat as requested. The following page is a list of staff
review comments detailing items that need to be addressed. Please address the comments and
submit the following information by Wednesday, December 27, 10:00 a.m. to be placed on the
next available Planning and Zoning Commission meeting scheduled for January 4, 2001, 7:00
p.m. in the City Hall Council Chambers, 1101 Texas Avenue.
Final Plat application;
$100 Final Plat application fee;
Ten (10) copies of the revised final plat;
The Mylar original of the revised final plat with the owner's signature.
If you have any questions or need additional information, please call me at 764-3570.
Attachments: Staff review comments
cc: Glenn Thomas, Via fax 690-7(18
Case file #00-212
Home of Texas A&M University
STAFF REVIEW COMMENTS
No. 2
Project: REGENCY SOUTH (FP)-FINAL PLAT (0-212)
ENGINEERING
1. An application is due with a $100.00 fee.
2. Paid tax certificates are necessary.
3. The additional drainage computations for the off-site improvements in
Longmire Park are accepted. The length of the 18' top width reinforced
concrete may be no shorter than 15', but must begin from Sta. 1+35.
The concrete shall still have 24" toewall, at the beginning and ending
stations, and 18" toewall on both sides. The remaining distance from the
end of the reinforced concrete to the opposite bank of the Bee Creek
shall be limestone rock rubble. All other items on your plan & profile
sheet should remain the same.
4. The sanitary sewer plan & profile are accepted. Please provide three
more copies of the sanitary sewer drawings for distribution.
5. The sewer line and the off-site drainage improvements in Longmire Park
must be completed before we file the plat. Or a bond, in an appropriate
amount, would be sufficient. The cost estimates for both were accepted.
Reviewed by: Thomas V. Vennochi Jr. Date: 12/18/00
NOTE: Any changes made to the plans, that have not been requested by the
City of College Station, must be explained in your next transmittal letter and
"bubbled" on your plans. Any additional changes on these plans that have not
been pointed out to the City, will constitute a completely new review.
Staff Review Comments Page 1 of 1
STAFF REVIEW COMMENTS
No. 3
Project: REGENCY SOUTH (FP)-FINAL PLAT (0-212)
ENGINEERING
1. The sanitary sewer plan & profile are accepted. Please provide three
more copies of the sanitary sewer drawings for distribution.
2. The proposed drainage improvement sheets are accepted, although a
drafting mistake was found indicating the end of the concrete rip-rap.
Please correct the drafting mistake and provide three more copies for
distribution.
Reviewed by: Thomas V. Vennochi Jr. Date: 01/03/01
NOTE: Any changes made to the plans, that have not been requested by the
City of College Station, must be explained in your next transmittal letter and
"bubbled" on your plans. Any additional changes on these plans that have not
been pointed out to the City, will constitute a completely new review.
Staff Review Comments Page 1 of 1