HomeMy WebLinkAbout00-00000211- 00073950CITY OF COLLEGE STATION
DEVELOPMENT SERVICES
1101 Texas Avenue South, PO Box 9960
College Station, Texas 77842
Phone (979) 764-3570 / Fax (979) 764-3496
MEMORANDUM
November 20, 2000
TO: Fred Patterson, Jr., AIA, Via fax 779-0727
FROM: Bridgette George, Asst. Development Coordinator
SUBJECT: Comfoit Inn -Site Plan
Staff reviewed the above-mentioned site plan as requested. The following page is a list of staff
review comments detailing items that need to be addressed. Please address the comments and
submit the following information for further staff review:
Two (2) revised site plans.
If there are comments that you are not addressing with the revised site plan, please attach a
letter explaining the details. If you have any questions or need additional information, please
call me at 764-3570.
Attachments: Staff review comments
cc: Zain Hyder, Comfort Inn College Station Hospitiality, Inc., 104 Texas Avenue S.,
College Station, TX, 77840
Steve E. Duncan, P.E., Via fax 731-5100
George R. Elrod, 779-0727
Case file #00-211
Home of Texas A&M University
STAFF REVIEW COMMENTS No. 1
Project: COMFORT INN (SITE PLAN)-SITE PLAN (0-211)
PLANNING
In order to ensure that the building additions do not encroach into any utility
easements, please show all easements on the site plan.
J2. Will any rooms be added in the "proposed single story building addition?" If
so, the site's off-street parking requirement will increase. This would need to
be addressed on the site plan by showing the full parking lot configuration and
a table listing the required and proposed parking.
3. Please provide a copy of the original site plan. Also, next to the line- "Partial
Site Development Plan" in the lower left corner, state in bold "Addition and
Renovation Plan - November 2000."
J4. In the title block, change Bryan, Texas to College Station, Texas.
5. Provide the site's legal description on the site plan.
.A. Sidewalks along Texas Avenue must be 6' in width. Please also note
engineering comment #1 regarding the placement of the sidewalk.
Reviewed by
Shauna Laauwe
Date: November 20, 2000
ENGINEERING
1. Please consider placing the new sidewalk approximately 10' closer to your
property line, between the sanitary sewer and waterline. By putting more
space between the Texas Avenue traffic and the pedestrian there will be an
increase in safety from errant vehicles.
2. Please line up the handicap ramps, if possible. Unaligned handicap ramps
should be avoided.
3. Per a site visit, it appeared that the dimensioning between your property line
and the existing curb is exaggerated by 5' or 6', and/or the sanitary sewer line
is misplaced on your drawing. Please check.
4. For the drainage to the gutter at either end of the property, the flow must be
under the sidewalk. Please annotate, show and detail how you plan to do so.
Staff Review Comments Page 1 of 2
5. After addressing the above comments, please submit to us a TXDOT Form
1058, `Permit to Construct Access Driveway Facilities on Highway Right of
Way', with three additional copies of your site plan.
Reviewed by: Thomas V. Vennochi Jr. Date: 11/17/00
ELECTRICAL
1. Developer responsible for installing conduit per city spec. and design.
2. Developer responsible for providing easements to cover all primary electrical
lines and equipment.
Reviewed by: Jennifer Reeves Date: 11/16/00
NOTE: Any changes made to the plans, that have not been requested by the
City of College Station, must be explained in your next transmittal letter and
"bubbled" on your plans. Any additional changes on these plans that have not
been pointed out to the City, will constitute a completely new review.
Staff Review Comments Page 2 of 2
ggR
J
CITY OF COLLEGE STATION
DEVELOPMENT SERVICES
1101 Texas Avenue South, PO Box 9960
College Station, Texas 77842
Phone (979) 764-3570 / Fax (979) 764-3496
MEMORANDUM
February 8, 2001
TO: Fred Patterson, Jr. AIA, Via fax 779-0727
FROM: Bridgette George, Asst. Development Review Manager
SUBJECT: Comfoitlrrn-Site Plan
Staff reviewed the above-mentioned site plan as requested and has comments only for your
information. The following page is a list of staff review comments. Please submit the following
information for the plans to be stamped approved and distributed:
Seven (7) copies of the revised site plan.
Please note that no work can begin on the sidewalks until the plans have been approved by
TxDOT. If you have any questions or need additional information, please call me at 764-3570.
Attachments: Staff review comments
cc: Zain Hyder, Comfort Inn College Station Hospitality, Inc., 104 Texas Avenue,
College Station, TX, 77840
Case file #00-211
Home of Texas A&M University
STAFF REVIEW COMMENTS
No. 2
Project: COMFORT INN (SITE PLAN)-SITE PLAN (0-211)
PLANNING
Developer has taken care of previous concerns that staff brought to their
attention on the first review. No comment.
Reviewed by:
Jennifer Reeves
Date: 02/01 /01
ENGINEERING
1. FYI - At one point ADA allowed single handicapped ramps at intersection
corners, facing kaddy-corner or diagonally out into the middle of the
intersection. Research was then conducted that showed that the blind or
those with limited vision or orientation were prone to wander out into the
intersection. It was then dictated that single diagonally facing ramps were
to be removed and replaced with two ramps on each side of the corner.
2. We have submitted to TXDOT, Form 1058, `Permit to Construct Access
Driveway Facilities on Highway Right of Way', with three additional copies
of your site plan for their review.
Reviewed by: Thomas V. Vennochi Jr. Date: 02/06/01
NOTE: Any changes made to the plans, that have not been requested by the
City of College Station, must be explained in your next transmittal letter and
"bubbled" on your plans. Any additional changes on these plans that have not
been pointed out to the City, will constitute a completely new review.
Staff Review Comments Page 1 of 1