HomeMy WebLinkAbout00-00000207- 00073923CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone (979) 764-3570 / Fax (979) 764-3496 MEMORANDUM November 14, 2000 TO: Joe Schultz, P. E., Texcon, Via fax 690-9797 FROM: Bridgette George, Asst. Development Coordinator SUBJECT: Castle gate Subdivision, Secdon 4, Phase I - Final Plat Staff reviewed the above-mentioned final plat as requested. The following page is a list of staff review comments detailing items that need to be addressed. Please address the comments and submit the following information by Monday, November 27, 10:00 a.m. to be placed on the next available Planning and Zoning Commission meeting scheduled for December 7, 2000, 7:00 p.m. in the City Hall Council Chambers, 1101 Texas Avenue. Ten (10) copies of the revised final plat; The Mylar original of the revised final plat with the owner's signature; Three (3) complete sets of the revised construction documents; Two (2) revised drainage reports; and, Construction documents with staff redlines (1). If you have any questions or need additional information, please call me at 764-3570. Attachments: Staff review comments Construction documents (1) Drainage Report (1) (please pick up at Development Services) cc: Wallace Phillips, Greens Prairie Investors, Ltd., Via fax 690--1480 Case file #00-207 Home of Texas A&M University STAFF REVIEW COMMENTS No. 1 Project: CASTLEGATE SUB SEC 4 PH 1 (FP)-FINAL PLAT (0-207) ENGINEERING Final Plat 1. Sheet 1: Metes and bounds description: Lot 6, Blk. 1-back line; N05*25'42"E 38.56': curve past C27-CB= S71 *-28'-56"E: Along Castlegate Drive, Lots 4&5, Blk. 2-351.49' not 318.64'. Lot 73, Blk. 2-south line-label 5' PUE. Crayke Place ROW; 50' not 60'. 2. Sheet 2: Meets and Bounds-15.40 acres not 14.50 acres; Certificate of Ownership-15.40 acres not 23.44 acres; Section 4, Phase 1. 3. Everything else looks fine. Construction Documents: 1. Sheet 2- Show ROW width of Kendal Green Circle at west end, ie-60'; add a detail to show how runoff from street ( drainage areas 64&75 will enter temporary drainageway. There is a vertical drop of over 8'. Need concrete riprap or a drop inlet to storm sewer pipe no. 408. 2. Sheet 9- Waterline W4-1; Sta. 4+58.20-8"x8" MJ Tee not 8"x6". 3.The remainder of the sheets are ok. Drainage Report: 1.Page 4- add; a small area ( approx. 1.7 acres) flows southwest from Alnwick Court and will remain undeveloped with this phase. 2. Page 6- Add areas 64, 75, and 100. Reviewed by: Ted Mayo Date: 11/13/00 ELECTRICAL 1. No Comment Reviewed by: Jennifer Reeves Date: 11/9/00 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Staff Review Comments Page 1 of 2 00 - 207 CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone (979) 764-3570 / Fax (979) 764-3496 MEMORANDUM November 15, 2000 TO: Joe Schultz, P.E., Texcon General Contractors, Via fax 690-9797 FROM: Bridgette George, Asst. Development Coordinator Of SUBJECT: Castlegato Phase 1 Design Reports - Final Plat Staff reviewed the above-mentioned design reports as requested and has no comments. The reports have been stamped approved and can be picked up at Development Services. If you have any questions or need additional information, please call me at 764-3570. Attachments: Staff review comments cc: Wallace Phillips, Greens Prairie Investors, Ltd, Via fax jrgo - Id Case file #00-207 Home of Texas A&M University N1l REVIEW COMMENTS No. 2 Project: CASTLEGATE SUB SEC 4 PH 1 (FP)-FINAL PLAT (0-207) ENGINEERING 1. Submittal of November 08,2000-Water and Sanitary Sewer Design Reports: Both of these reports are acceptable as submitted. Reviewed by: Ted Mayo Date: 11/14/00 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Staff Review Comments Page 1 of 1 STAFF REVIEW COMMENTS No. 2 Project: CASTLEGATE SUB SEC 4 PH 1 (FP)-FINAL PLAT (0-207) PLANNING 1. Reviewed by: *PLANNER NOT ASSIGNED* Date: ENGINEERING 1. Final plat is ok. 2. Construction documents are ok. 3. Drainage Report is ok. 4. Sewer design report is ok. 5. Cost Estimate needs revisions-see comments under DP 500074. Reviewed by: Ted Mayo Date: 11/21/00 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. STAFF REVIEW COMMENTS No. 2 Staff Review Comments Page 1 of 1 STAFF REVIEW COMMENTS No. 1 Project: CASTLEGATE SUB SEC 4 PH 1 (FP)-FINAL PLAT (0-207) PLANNING 1. Reviewed by: *PLANNER NOT ASSIGNEW Date: ENGINEERING Final Plat 1. Sheet 1: Metes and bounds description: Lot 6, Blk. 1-back line; N05*25'42"E 38.56': curve past C27-CB= S71 *-28'-56"E: Along Castlegate Drive , Lots 4&5, Blk. 2-351.49' not 318.64'. Lot 73, Blk. 2- south line-label 5" PUE. Crayke Place ROW; 50' not 60'. 2. Sheet 2: Meets and Bounds-15.40 acres not 14.50 acres; Certificate of Ownership-15.40 acres not 23.44 acres; Section 4, Phase 1. 3. Everything else looks fine. Reviewed by: Ted Mayo ELECTRICAL 1. No Comment Reviewed by Jennifer Reeves Date: 11 /10/00 Date: 11/9/00 Staff Review Comments Page 1 of 2