HomeMy WebLinkAbout02-00500132- 00073756FOR OFFICE USE ONLY
P&Z CASE NO.: a- 130.
DATE SUBMITTED: o a-0O
430 PM
(check one)
PRELIMINARY PLAT APPLICATION
Preliminary Plat Master Preliminary Plat
The following items must be submitted by an established filing deadline date for P & Z Commission
consideration.
MINIMUM SUBMITTAL REQUIREMENTS:
V ing Fee of $400.00.
plication completed in full.
irteen (13) folded copies of plat. (A revised mylar original must be submitted after staff review.)
e (1) copy of the approved Master Development Plan or Master Preliminary Plat if applicable.
opy of th e attached checklist with all items checked off or a brief explanatign as to why they ar not.
Rezoning Application if zone change is proposed. Arcady 5V6m RC.d . 3 -16 y
APPLICATION DATA
I *o ( arno(a 4
NAME OF SUBDIVISION Carroll Addition
SPECIFIED LOCATION OF PROPOSED SUBDIVISION Arnold Road next to sun Meadows
Subdivision, Phase 2
APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name Joe Gattis
Street Address 505 University Drive, Suite #803
City College Station State Texas Zip Code 77840
E-Mail Address abei@txcyber.com
Phone Number (979) 846-6914 Fax Number
PROPERTY OWNER'S INFORMATION:
Name Ali Safi
(979) 846-8914
Street Address 1923 Woodsman Drive
Citv College
E-Mail Address n/a
Station
State Texas Zip Code 77840
Phone Number (979) 260-8388 Fax Number
ARCHITECT OR ENGINEER'S INFORMATION:
Name Ash & Browne Engineering, Inc.
(979) 691-2448
Street Address 505 University Drive, Suite #803
City College Station State Texas Zip Code 77840
E-Mail Address abei@txcyber.com
Phone Number -(979) 846-6914 Fax Number (9-79) 846-8914
PRELIMINARY PLAT APPLICATION I of 2
PPAPP.DOC 12/03/01
TOTAL ACRES OF SUBDIVISION 7.913 R-O-W ACREAGE 0.962 TOTAL # OF LOTS--L6
NUMBER OF LOTS BY ZONING DISTRICT 26 / R-1
AVERAGE ACREAGE OF EACH RESIDENTIAL LOT BY ZONING DISTRICT:
0.202/ R-1_ FLOODPLAIN ACREAGE 1.648 acres
PARKLAND DEDICATION BY ACREAGE OR FEE? Fee
A STATEMENT ADDRESSING ANY DIFFERENCES BETWEEN THE PRELIMINARY PLAT AND APPROVED
MASTER DEVELOPMENT PLAN AND/OR MASTER PRELIMINARY PLAT (IF APPLICABLE):
n/a
REQUESTED VARIANCES TO SUBDIVISION REGULATIONS & REASON FOR SAME
To develop a 26 lot cul-de-sac in lieu of the maximum of 24 lots
The 26 lots are required to fiscally make the development viable
REQUESTED OVERSIZE PARTICIPATION_ we are requesting Over Participation on the
8" sanitary sewer line, the extension of the 12" water main along
Arnold Rd., and the extension of Arnold Rd.
The applicant has prepared this application and certifies that the facts stated herein and exhibits
attached here are true and correct. The undersigned hereby requests approval by the City of
College tati of the above identified plat.
) -4,~ I Vag eL J t-1 Im
Sin re an Title Date
PRELIMINARY PLAT APPLICATION 2 of 2
PPAPP.DOC 12/03/01
SUBMIT APPLICATION AND THIS
UST CHECKED OFF WITH 13
FOLDED COPIES OF PLAT FOR REVIEW
PRELIMINARY PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Include the words "PRELIMINARY
PLAT - NOT FOR RECORD" in letters 1/2" high. If more than 1 sheet, an index sheet showing
entire subdivision at a scale of 500 feet per inch or larger.
L2 2. Vicinity map which includes enough of surrounding area to show general location of subject
property in relationship to College Station and its City Limits. No scale required but include north
arrow.
3. Titl lock with the following information:
Name and address of subdivider, recorded owner, planner, engineer and surveyor.
Proposed name of subdivision. (Subdivision name & street names will be approved
through Brazos County 911.) (Replats need to retain original subdivision name.)
Date of preparation. (INCLUDE DATE THE PLAT WAS SUBMITTED AND THE DATES
OF ANY REVISIONS ON THE PLAT)
VEngineer's scale in feet.
Total area intended to be developed.
4. North Arrow.
5. Location of current city limit lines and current zoning di
tY strict boundary.
6. Subdivision boundary indicated by heavy lines. Boundary must include all of parent tract.
7. Descriptions by metes and bounds of the subdivision which shall close within accepted land survey
standards. (Labeled on boundary lines, not separate metes and bounds description.)
8. Primary control points or descriptions and ties to such control point, to which , later, all dimensions,
angles, bearings, block numbers, and similar data shall be referred. The plat shall be located with
respect to a corner of the survey or tract, or an original corner of the original survey of which it is a
part.
9. Name of contiguous subdivisions and names of owners of contiguous parcels of unsubdivided
land, and an indication whether or not contiguous properties are platted.
10. Location of the 100 Year Floodplain and Floodway, if applicable, according to the most recent
available data.
11. Topographic information, including contours at two foot (2 ft.) intervals, wooded areas, and flowline
elevation of streams.
12. Proposed land uses (In compliance with Land Use Plan).
13. Proposed zoning changes, if any, submit formal rezoning request.
PRELIMINARY PLAT CHECKLIST 10f2
PPCK.DOC 12/03/01
14. The location and description with accurate dimensions, bearings or deflection angles and radii,
area, center angle, degree of curvature, tangent distance and length of all curves for all of the
following: (Show existing items that are intersecting or contiguous with the boundary of or forming
a boundary with the subdivision, as well as, those within the subdivision).
Existing P o ed
0 treets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp.
turn around unless they are shorter than 100 feet.
Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s
sufficient to meet Thoroughfare Plan.)
~j Street offsets and/or intersection angles meet ordinance.
rlI Alleys.
Reserve tracts.
Well site locations.
Pipelines. If carrying flammable gas or fuel, also show size of line, design pressure and
product transported through the line.
Utility Services. (Water & Sanitary Sewer) All existing and proposed utilities of sufficient
size/depth to meet the utility master plan and any future growth areas.
Easements.
0 Drainage Structures and improvements including underground storm sewer and all
overland systems (flow line of existing watercourses) and showing where these will
discharge. Proposed channel cross sections, if any.
~t.►' A number or letter to identify each lot or site and each block.
El Greenbelt area/park linkages/parkland dedication ( All proposed dedications must be
.nn reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.)
N1~ -0'-5- Public areas
Other public improvements, including but not limited to parks, schools and other public
facilities
15. Proposed phasing. Each phase must be able to stand alone to meet ordinance requirements and
infrastructure costs should be distributed evenly throughout the subdivision..
vfl~K
16. Are there impact fees associated with this development?
es No
ria 17. If requesting oversize participation items, are the necessary impact studies included? Yes N/A
PRELIMINARY PLAT CHECKLIST
PPCK.DOC 12/03/01 2 of 2