Loading...
HomeMy WebLinkAboutApplicationO Y FOR OFF4ES &Z CASE NO.: P DATE SUBMITTED: CITY OF COLLEGE STATION Planning c5' Derxlopmens $rrvira FINAL PLAT Ano~ICATION Amending Final ❑ Vacating ❑ Replat (Check one) ❑ Minor ❑ g F$400.00) ($400.00) (;600.00)- (;300.00) ($300.00) `Includes public hearing fee The following items must be submitted by an established filing deadline date for P&Z Commission consideration. MINIMUM SUBMITTAL REQUIREMENTS: t/ Filing Fee (see above) NOTE: Multiple Sheets - $55.00 per additional sheet AL Variance Request to Subdivision Regulations - $100 (if applicable) A~q_- Development Permit Application Fee of $200.00 (if applicable). AW_ Infrastructure Inspection Fee of $600.00 (applicable if any public infrastructure is being constructed) y Application completed in full. Copy of original deed restrictions/covenants for replats (if applicable). Thirteen (13) folded copies of plat. (A signed mylar original must be submitted after staff review.) One (1) copy of the approved Preliminary Plat and/or one (1) Master Plan (if applicable). Paid tax certificates from City of College Station, Brazos County and College Station I.S.D. _ A copy of the attached checklist with all items checked off or a brief explanation as to why they are not. ~i Two (2) copies of public infrastructure plans associated with this plat (if applicable). Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of approval (if applicable). Date of Preapplication Conference: NAME OF SUBDIVISION SPECIFIED LOCATION OF PROPOSED SUBDIVISION I p,4 (Lot & Block) n. mob. : rte G f) CA rci ` Qtc3i~Yle~ APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name I Cif" Su`e8i nuuress y, State Zip Code JJy7z /c7 E-Mail Address lau,"so barker -(!2086&n . ne1=_ Phone Number Fax Number ~ j1 !Dq PROPERTY OWNER'S INFORMATION: Name City Street Address )5Fnr 4 State Zip Code _7 7 3,8,q E-Mail Address Phone Number'(u -'an ! Fax Number ARCHITECT OR ENGINEER'S INFORMATION: Name Street Address State Zip Code Phone Number 6/13/03 E-Mail Address Fax Number City 1 of 5 ~ Is there a temporary blanket :esement on this property. If so, provide .,,e Volume _ and Page # R-aw Acreage 0 /y 3 Total # Of Lots Acreage -Total Property / 7 XI / Proposed Use: _ p~reejor~44 Existing Use: ~nl? Number Of Lots By Zoning District Average Acreage Of Each Residential Lot By Zoning District: Floodplain Acreage A statement addressing any differences between the Final Plat and approved Master Plan and/or Preliminary Plat (if applicable): Requested Variances To Subdivision Regulations & Reason For Same: Requested Oversize Participation: Total Linear Footage of Proposed Public: Streets Sidewalks Sanitary Sewer Lines Water Lines Channels Storm Sewers Bike Lanes / Paths Parkland Dedication due prior to filing the Final Plat: ACREAGE: # of acres to be dedicated + $ - development fee # of acres in floodplain # of acres in detention # of acres in greenways OR FEE IN LIEU OF LAND: _ # of Single-Family Dwelling Units X $556 = $ (date) Approved by Parks & Recreation Board NOTE: DIGITAL COPY OF PLAT MUST BE SUBMITTED PRIOR TO FILING. herein and a Station o~he above ereto'are ttrue, The applicant has prepared this application and certifies that t facts stated correct, and complete. The undersigned hereby requests approval Y Y of Colleg final plat and attests that this request does not amend any covenants or restrictions associated with this plat. iDate 2of5 6/13103 CITY OF COLLEGE STATION Planning C ' D~"*Ivpmrnt Servitor SUBMIT APPLICATION AND THIS LIST CHECKED OFF WITH 13 FOLDED COPIES OF PLAT FOR REVIEW FINAL PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE INCLUDING o BUT survey maTrlcOed THE by monuLmOeVnfs and markers. ents based /1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. locat subj ect ion Vicinity map which includes enough Staof surrounding area to show tion and is City Lim its. No sca general equ red but include north property in relationship to College arrow. ❑r' 3. Title Block with the following information: Name and address of subdivider, recorded owner, planner, engineer and surveyor. Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to~reettain original subdivision name.) • Date of preparation. Aoc~C. S 0.4 Engineer's scale in feet. Total area intended to be developed. .E5'~,-4. North Arrow. 5. Subdivision boundary indicated by heavy lines. ❑ ,/6. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. 7. All a Iicable certifications based on the type of final plat. ,pp nership and Dedication Surveyor and/or Engineer City Engineer (and City Planner, if a minor plat) Planning and zoning Commission (delete if minor plat) Brazos County Clerk ❑ Brazos County Commissioners Court Approval (ETJ Plats only) (]'~//18 Paid tax certificates. improvements, submit survey ❑ )?9- If submitting a replat where meeto rensure'that no encroachments wi I be createdof the subject property showing the improvements hat private may County 10. If using private septic systems, abddd' s general without thenisthe suanice tof a I cense by the B facility L be installed on any lot in in this the Health Unit under the provisions privafacility te of Section t21 004 ofthe Texas Wa erlCode issioner's Court of Brazos County, pursuant to the provisions 11. Location of the 100 Year Floodplain and floodway, if applicable, according to the most recent available data. 12. Lot comer markers and survey monuments (by symbol) and clearly tied to basic survey data. K13. Matches the approved preliminary plat and/or master development plan. 4of5 6113/03 sions defle rad p~ 14. The location aitu description with accurate lndi tancecandgength of al,curveslfor aloof the degree of curvature, tangent area, center angle, following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as well as, those within the subdivision). Existing Proposed Streets. Continuous or aend in a cul-de-sac, re shorter than 100 feet. out streets must end into a temp turn around unless they Q~ Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to meet Thoroughfare Plan.) ❑ ❑ Street offsets and/or intersection angles meet ordinance. ❑ ❑ Alleys. Easements. ❑ ©-/'A number or letter to identify each lot or site and each block. l proposed ded ations must ❑ ❑ Greenbelt area/park linkages/parkland eaion Board prior to P l& Z Commission'cconside at on )e reviewed by y the the Parks and Recreation include the followings" sheets and properly sealed 15. Construction documents for all public infrastructure by a Licensed Texas Professional Engineer that et must the show overall ❑ Street, alley and sidewalk plans, profiles of the subdivision. (mayebe comb ned w th other street, alley and/or sidewalk layout utilities). Sanitary sewer plan and profile showing depth and grades. One sheet must show the overall sewer layout of the subdivision. ion. (Utilities of sufficient size/depth to meet the utility master plan and any future growth ) lines ❑ Water line plan showing fire hydrUS{shovalves, etc. w the overall with waplan ter layout ofprofile the subdi ~s o 9 must depth and grades. One sheet (Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) ❑ Storm drainage system plan with contours, street profile, inlets, storm sae a runoff drainage channels, and 100 year sections. d ainage structure design, with profiles and based 5, 10, 25, 50 channel l lining design & detention if used. One sheet must show the overall drainage layout of the subdivision. ❑ Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E. ❑ Drainage Report. ❑ Erosion Control Plan (must be included in construction plans). ❑ 16. All off-site easements necessary for infrastructure construction must be shown on the final plat with concurrently instrument easements were filed. a volume and page listed to indicate filed the Separate instrument easements must be prior or with Final Plat. ❑ 17. Are there impact fees associated with this development? ❑ Yes Impact fees for R-1, R-2, & R-3 zoned final plats, must be paid prior to filing. ❑ Yes No 18. Will any construction occur in TexDOT rights-of-way? If yes, TexDOT permit must be submitted along with the 'in digital form if available prior to NOTE: 1. We will be requesting the corrected Final Plat to be submitted filing the plat at the Courthouse. 2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted prior to issuance of a development permit. 5of5 6113103 DEVELOPMENT SERVICES TRANSMITTAL LETTER Project: Z Date: Name/Firm: Address: Fax: Phone: 5 transmitting the following for Development Services to review and comment: (Check all ethat nt Perm. App. We are F1 Development ❑ Masten Development Plan w/ E] Redlines E] Conditional Use Permit v~ Preliminary Plat- MA ~ w/ ❑ Redlines ❑ Rezoning Application w/ ❑ Redlines ~inal Plat - 6o~+~`~ ❑ FEMA CLOMA/CLOMR/LOMA/LOMR w/ Redlines ❑ Variance Request Site Plan w/ ❑ ether -Please specify ❑ F-1 Redlines ❑ Grading Plan w/ ❑ Redlines w/ ❑ Redlines ❑ Landscape Plan ❑ Irrigation Plan w/ ❑ Redlines ❑ Building Construction Documentsw/ ❑ Redlines INFRASTRUCTURE AND ENGINEERING DOCUMENTS All infrastructure documents must be submitted as a complete set. The following are included in the complete set: ❑ TxDOT Driveway Permit ❑ Waterline Construction Documents w/ ❑ Redlines i?F1 TxDOT Utility Permit Sewerline Construction Documents w/ Redlines ❑ Other -Please specify ❑ Drainage Construction Documents w/ ❑ Redlines w/ ❑ Redlines ❑ Street Construction Documents ❑ Easement application with metes & bounds decsription I ❑ Drainage Letter or Report w/❑ Redlines ❑ Fire Flow Analysis w/ ❑ Redlines VVVV Special Instructions: 1 of 1 1-Aug-02