Loading...
HomeMy WebLinkAbout02-00500107- 00073340FOR OFFICE USE ONLY P&Z CASE NO.: U - /0 - I W ��f ` V ' '�- ��A�L�� � DATE SUBMITTED: 6 ,-;� 02 : 3. -% FINAL PLAT APPLICATION (Check one) Minor Amending Final Vacating Replat ($300.00) ($300.00) ($400.00) ($400.00) ($400.00) The following items must be submitted by an established filing deadline date for P&Z Commission consideration. MINIMUM SUBMITTAL REQUIREMENTS: d cling Fee (see above) NOTE: Multiple Sheets - $55.00 per additional sheet evelopment Permit Application Fee of $200.00 (if applicable). Infrastructure Inspection Fee of $400.00 (applicable if any public infrastructure is being constructed.). Application completed in full. Thirteen (13) folded copies of plat. (A signed mylar original must be submitted after staff review.) One (1) copy of the approved Preliminary Plat and /or one (1) Master Plan (if applicable). Paid tax certificates from City of College Station, Brazos County and College Station I.S.D. copy of the attached checklist with all items checked off or a brief explanation as to why they are not. wo (2) copies of public infrastructure plans associated with this plat (if applicable). r Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of approval (if applicable). NAME OF SUBDIVISION University Preserve SPECIFIED LOCATION OF PROPOSED SUBDIVISION Lots 13, 14, and 15 of woodlandEstates -� near the intersection of Dominik Drive and Munson Av enue. APPLICANT /PROJECT MANAGER'S INFORMATION (Primary Contact for the Project): Name J. Dale Browne, Jr., P.E., Ashe & Browne Engineering, Inc. Street Address P.O. Box 10838 State TX Zip Code 77842 Phone Number ( 979) 846 -6914 PROPERTY OWNER'S INFORMATION: City College Station E -Mail Address abei@txcyber Fax Number ( 979) 846 -8914 Name Crux Financial Services, Inc. Street Address 502 Arrowhead Point Road State TX Zip Code 76513 E -Mail Address E -Mail Address Phone Number ( 254) 780 - 1100 Fax Number ( 254) 780 - 9975 ARCHITECT OR ENGINEER'S INFORMATION: Name Same as Applicant. Street Address State Phone Number Zip Code City Belton switzerdeaso City Fax Number FNLPAPP.DOC 02/10/2002 ) �`- 1 , , �� (�- t l J 1 of 3 Total Acres Of Subdivision 14.009 R -O -W Acreage 0 Number Of Lots By Zoning District 2 6 / R1 / Average Acreage Of Each Residential Lot By Zoning District: .525 / R1 Total # Of Lots II Floodplain Acreage None A Statement Addressing Any Differences Between The Final Plat And Approved Master Development Plan And /Or Preliminary Plat (If Applicable): Distances and Bearings Reused Base on Field Survey. Property Lines take to middle of road, detention area resize. Requested Variances To Subdivision Regulations & Reason For Same: None Requested Oversize Participation: None Total Linear Footage of Proposed Public: NA Streets NA Sidewalks 1,95 Sanitary Sewer Lines 1,87 Water Lines NA Channels NA Storm Sewers NA Bike Lanes / Paths Parkland Dedication due prior to filing the Final Plat: ACREAGE: 0 # of acres to be dedicated + $ development fee 0 # of acres in floodplain 0. 9 0 7 # of acres in detention 0 # of acres in greenways OR FEE IN LIEU OF LAND: 22 # of Single- Family Dwelling Units X $457 = $ 10054.00 (date) Approved by Pa & Recreation Board NOTE: DIGITAL COPY OF PLAT MUST BE SUBMITTED PRIOR TO FILING. The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true, correct and complete. The undersigned hereby requests approval by the City of College Station of the ab ve- identified final plat. r ignature and Title Date FNLPAPP.DOC 02/1012002 2 of 3 SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION Application is hereby made for the following development specific site /waterway alterations: None ACKNOWLEDGMENTS: I, J. Dale Browne, Jr. , design engineer /owner, hereby acknowledge or affirm that: The information and conclusions contained in the above plans and supporting documents comply with the current requirements of the City of College Station, Texas City Code, Chapter 13 and its associated Drainage Policy and Design Standards. As a condition of approv of th i ermit application, I agree to construct the improvements proposed in this apAic�1oryicccy�ding to these docyr nt nd the requirements of Chapter 13 of the College Station City Code. E n g i n ems/ Contractor CERTIFICATIONS: (for proposed alterations within designated flood hazard areas.) A.I, certify that any nonresidential structure on or proposed to be on this site as part of this application is designated to prevent damage to the structure or its contents as a result of flooding from the 100 year storm. Engineer Date B. I, certify that the finished floor elevation of the lowest floor, including any basement, of any residential structure, proposed as part of this application is at or above the base flood elevation .- .established in the latest Federal Insurance Administration Flood Hazard Study and maps, as amended. Engineer Date C. I, , certify that the alterations or development covered by this permit shall not diminish the flood- carrying capacity of the waterway adjoining or crossing this permitted site and that such alterations or development are consistent with requirements of the City of College Station City Code, Chapter 13 concerning encroachments of floodways and of floodway fringes. Engineer Date D. I, , do certify that the proposed alterations do not raise the level of the 100 year flood above elevation established in the latest Federal Insurance Administration Flood Hazard Study. Engineer Date Conditions or comments as part of approval: In accordance with Chapter 13 of the Code of Ordinances of the City of College Station, measures shall be taken to insure that debris from construction, erosion, and sedimentation shall not be deposited in city streets, or existing drainage facilities. All development shall be in accordance with the plans and specifications submitted to and approved by the City Engineer for the above named project. All of the applicable codes and ordinances of the City of College Station shall apply. u FNLPAPP.DOC 02/10/2002 3 of 3 SUBMIT APPLICATION AND THIS LWr CS uXW OFF WITH 13 FOLDED COPIES OF PLAT FOR REVIEW FINAL PLAT MINIMUM REQUIREMENTS (ALL CITY ORDINANCES MUST BE MET) INCLUDING BUT NOT LEMTED TO THE FOLLOWING: rrements based on field survey and marked by monuments and mm a WV 4. 5 6. 7. All applicable certifications based on the type of final plat. Ownership and Dedication Surveyor and/or Engineer C AY Engineer (and City Planner, if a minor plat) (� Planning and Zoning Commission (delete if minor plat) Brazos County Clerk L9' Bra County Commissioners Court Approval (ETJ Plats only) 8. Paid tax certificates. 9. If submitting a replat where there are existing i submit a survey g p of the subject property showing the improvements to ensure that no encroachments will be created. Id�f 10. If using private septic systems, add a general note on the plat that no private sewage facility may be installed on any lot in this subdivision without the issuance of a license by the Brazos County Health Unit under the provisions of the private facility regulations adopted by the Commissioner's Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code. Location of the 100 Year Floodplain and floodway, if applicable, according to the most recent available data. 12. Lot comer markers and survey onuments ey (by symbol) and clearly tied to basic survey data. Drawn on 24" x 36" sheet to scale of 100' per inch or larger. Vicinity map which includes enough of surrounding area to show general location of subject property in relationship to College Station and its City Limits. No scale required but include north arrow. Titl ock with the following information: Name and address of subdivider, recorded owner, planner, engineer and surveyor. �f Proposed name of subdivision. (Subdivision name & street names will be approved through Brazos County 911.) (Replats need to retain original subdivision name.) /Date of preparation. Iff gmeer's scale in feet. Total area intended to be developed. North Arrow. Subdivision boundary indicated by heavy lines. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or larger. FINAL PLAT CHECKLIST 142 FNLPCLDOC 03/25/99 3. Matches the approved preliminary plat and/or master development plan. 14. The location and description with accurate dimensions, bearings or deflection angles and radii, area, center angle, degree of curvature, tangent distance and length of all curves for all of the following: (Show existing items that are intersecting or contiguous with the boundary of or forming a boundary with the subdivision, as well as, those within the subdivision). EProp�d Streets. Continuous or end in a cul- ie-sac, stubbed out streets must end into a temp. turn around 0 unless they are shorter than 100 feet. [� Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s sufficient to S meet Thoroughfare Plan.) f� Street offsets and/or intersection angles meet ordinance. �d All eys. Easements. A number or letter to identify each lot or site and each block. Greenbelt area/park linkages/parkland dedication ( All proposed dedications must be reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.) O 15. Construction documents for all public infrastructure drawn on 24" x 36" sheets and properly sealed by a Li Texas Professional Engineer that include the following: Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall street, , / - alley and/or sidewalk layout of the subdivision. (may be combined with other utilities). Sanitary sewer plan and profile showing depth and grades. One sheet must show the overall sewer layout of the subdivision. (Utilities of sufficient size/depth to meet the utility master plan and any future growth areas.) Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing depth and grades. One sheet must show the overall water layout of the subdivision. (Utilities of sufficient sizeldepth to meet the utility master plan and any future growth areas.) Storm drainage system plan with contours, street profile, filets, storm sewer and drainage channels, with profiles and sections. Drainage and runoff areas, and runoff based on 5, 10, 25, 50 d 100 year rain intensity. Detailed drainage structure design, channel lining design & detention if used. One sheet must show the overall drainage layout of the subdivision. /Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E. rainage Report. Erosion Control Plan (must be included in construction plans). rl/q ❑ 16. All off -site easements necessary for infrastructure construction must be shown on the final plat with a volume and page listed to indicate where the separate instrument easements were filed. Separate instrument easements must be filed prior or concurrently with Final Plat. 17. Are there impact fees associated with this development? ❑Yes pNo Impact fees for R -1, R -2 & R -3 zoned final plats, must be paid prior to filing. 18. Will any construction occur in TexDOT rights -of -way? ❑ Yes V-No If yes, TexDOT permit must be submitted along with the construction documents. NOTE: 1. We will be requesting the corrected Final Plat to be submitted in digital form if available prior to filing the plat at the Courthouse. 2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted prior to issuance of a development permit. FINAL PLAT CHECKLIST 2 of 2