HomeMy WebLinkAbout02-00500108- 00073306<.OL I. EGE STATION
FOR OFFICE USE ONLY
P&Z CASE NO.: oZ`'
DATE SUBMITTED:
FINAL PLAT APPLICATION
(check one) Minor Amending X Final Vacating Replat
The following items must be submitted by an established filing deadline date for P&Z Commission
consideration.
MINIMUM SUBMITTAL REQUIREMENTS:
X Filing Fee of $400.00.
X Development Permit Application Fee of $200.00 (if applicable).
X Infrastructure Inspection Fee of $600.00 (applicable if any public infrastructure is being constructed.).
X Application completed in full.
X Thirteen (13) folded copies of plat. (A signed mylar original must be submitted after staff review.)
N/A One (1) copy of the approved Preliminary Plat and/or one (1) Master Plan (if applicable).
X Paid tax certificates from City of College Station, Brazos County and College Station I.S.D.
X A copy of the attached checklist with all items checked off or a brief explanation as to why they are not.
X Two (2)copies of public infrastructure plans associated with this plat (if applicable).
N/A Parkland Dedication requirement approved by the Parks & Recreation Board, please provide proof of
approval (if applicable).
NAME OF SUBDIVISION Lot 3 Block 1 One Lincoln Place
SPECIFIED LOCATION OF PROPOSED SUBDIVISION 1010 University Drive
APPLICANT/PROJECT MANAGER'S INFORMATION (Primary Contact for the Project):
Name Urban Design Group
Street Address 2700 Earl Rudder Frwy., S., Suite 4300 City College Station
State Texas Zip Code 77845 E-Mail Address dkeatingO-udgcs.com
Phone Number 979-696-6953 Fax Number 979-696-9752
PROPERTY OWNER'S INFORMATION:
Name Thomas Kirkland
Street Address 7502 Greenville Avenue, Suite 500 City Dallas
State Texas Zip Code 75231 E-Mail Address
Phone Number 214-890-9225 Fax Number 2-1'4 - S2 L - 4 04
ARCHITECT OR ENGINEER'S INFORMATION:
Name Urban Design Group
Street Address 2700 Earl Rudder Frwy., S., Suite 4300 City College Station
rotate Texas Zip Code 77845 E-Mail Address dkeating(&-udgcs.com
Phone Number 979-696-6953 Fax Number 979-696-9752
Total Acres Of Subdivision 2.888 R-O-W Acreage 0 # Of Lots 2
Number Of Lots By Zoning District 2 /C-B
Average Acreage Of Each Residential Lot By Zoning District:
N/A
Floodplain Acreage 0
A Statement Addressing Any Differences Between The Final Plat And Approved Master Development Plan
And/Or Preliminary Plat (If Applicable):
N/A
Requested Variances To Subdivision Regulations & Reason For Same
N/A
Requested Oversize Participation
N/A
Total Linear Footage of
Proposed Public:
Streets
Sidewalks
275 FT Sanitary Sewer Lines
Water Lines
Channels
Storm Sewers
Bike Lanes / Paths
Parkland Dedication due prior to filing the Final Plat:
ACREAGE:
0
# of Acres to be dedicated
0
# of acres in floodplain
0
# of acres in detention
0
# of acres in greenways
OR
FEE IN LIEU OF LAND:
# of Single-Family Dwelling Units X $457
(date) Approved by Parks & Recreation Board
NOTE: DIGITAL COPY OF PLAT MUST BE SUBMITTED PRIOR TO FILING.
The applicant has prepared this application and certifies that the facts stated herein and exhibits attached
hereto are true, correct and complete. The undersigned hereby requests approval by the City of College
Station of the above-identified final plat.
Signature and Title Date
FNI PAPP rX)C: 5/99/(19 9 of 3
May 23 02 01:01p Thomas Kirkland
214 090--1355 P.1
FROM : URBAN DESIGN GRIUP FAX NO. : 979-6%-9752 May. 23 2002 06:13FMt F~
SUPPLEMENTAL DEVELOPMENT PERMIT INFORMATION
Appitcabon is hereby mace for the f allowing development specific siteMiateiv t alterations:
_~'anSd ir- c-+S'e,~ o F (o ~ " Sg r7 1- •1, 5 G•+~ a. W-
V
LEDGMENTS:
1, Yhomial and , owner, hereby ar.;knawSWge of affirm that
The information and conclusions Wntained In the above plans and supporting documents comply with the current
requirements of the City of College Station, Texas City Code, Chapter 13 and its associated Drainage Policy and Design
Standards. As a condition of approval of this permit application, i agree to constn,ct the improvements proposed in this
applicafio acoordln to th docunrmts and the requirements of Chapter 13 of the College Station City Code.
P►ope+ty' er(s1 f~ji~l ~f > ~dr<hr` 1~ rf Contr"or -
CERTIFICATIOffl, (for proposed alterations within designated flood hazard amas.)
A. I. _ certify that any nonresidential structure on or proposed to be on this site
as pars of this application is designated to prevent damage to the structure or its contents as a result of flooding from the
100 year storm.
Engineer - - Date
B- 1, certify that the finished floor elevation of the iawiest flow, including any
basement, of arry residential structure, propacd as part of this application is at or above the base flood elevation
established In the latest Federal nsuiancei Adn, inia.ration t=lppd Hazaurl Study and maps, as amended,
Engineer - Date
C. I, D~3er11'J-4,,t ►cf~-_--. certify that the alterations or development covered by this permit shall
not diminish the flood-carrying catkrcity of the waterway adjoining or crossing this permitted site and that such alterations
or development are consistent with requimments of the City of College Station City Code, Chapter 13 conceming
encroachments of floodvrays and of foodway fringes.
Engineer Uwe
D. 1, , do certify that the propesod alterations do not raise the level of the 100
year flood above elevation established in the latest Federal Insurance Adminietation Flood Hazard Study.
Engineer
Date
Conditions or comments as part of approval-
in acoouance warn unapter j.3 or we uooe of urtanana= or the city o1 uonege station, measurers shat be taken to
insure that debris from construction, erosion, and sedimentation shad not be deposited in city streets, or existing drainage
facilities.
All development shall be in accordance with the plans and swifications submitted to and aprircwod by flea City Fgioeor
for tho above named project, All pf time applicable rodes and ordinances of the City of College Station shalt >t Wy,
SUBMIT APPLICATION AND THIS
LIST CHECKED OFF WITH 13
FOLDED COPIES OF PLAT FOR REVIEW
FINAL PLAT MINIMUM REQUIREMENTS
(ALL CITY ORDINANCES MUST BE MET)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
(Requirements based on field survev and marked by monuments and markers.)
X 1. Drawn on 24" x 36" sheet to scale of 100' per inch or larger.
X 2. Vicinity map which includes enough of surrounding area to show general location of subject
property in relationship to College Station and its City Limits. No scale required but include north
arrow.
X 3. Title Block with the following information:
X Name and address of subdivider, recorded owner, planner, engineer and surveyor.
X Proposed name of subdivision. (Subdivision name & street names will be approved through
Brazos County 911.) (Replats need to retain original subdivision name.)
X Date of preparation.
X Engineer's scale in feet.
X Total area intended to be developed.
X 4. North Arrow.
X 5. Subdivision boundary indicated by heavy lines.
N/A 6. If more than 1 sheet, an index sheet showing entire subdivision at a scale of 500 feet per inch or
larger.
X 7. All applicable certifications based on the type of final plat.
X Ownership and Dedication
X Surveyor and/or Engineer
X City Engineer (and City Planner, if a minor plat)
X Planning and Zoning Commission (delete if minor plat)
X Brazos County Clerk
N/A Brazos County Commissioners Court Approval (ETJ Plats only)
X 8. Paid tax certificates.
X 9. If submitting a replat where there are existing improvements, submit a survey of the subject
property showing the improvements to ensure that no encroachments will be created.
N/A 10. If using private septic systems, add a general note on the plat that no private sewage facility may
be installed on any lot in this subdivision without the issuance of a license by the Brazos County
Health Unit under the provisions of the private facility regulations adopted by the Commissioner's
Court of Brazos County, pursuant to the provisions of Section 21.004 of the Texas Water Code.
❑ 11. Location of the 100 Year Floodplain and floodway, if applicable, according to the most recent
available data. NONE
X 12. Lot corner markers and survey monuments (by symbol) and clearly tied to basic survey data.
FINAL PLAT CHECKLIST I of 2
❑ 13. Matches the approved preliminary plat and/or master development plan. NONE
X 14. The location and description with accurate dimensions, bearings or deflection angles and radii,
area, center angle, degree of curvature, tangent distance and length of all curves for all of the
following: (Show existing items that are intersecting or contiguous with the boundary of or
forming a boundary with the subdivision, as well as, those within the subdivision).
Existing Proposed
X N/A Streets. Continuous or end in a cul-de-sac, stubbed out streets must end into a temp
turn around unless they are shorter than 100 feet.
X N/A Public and private R.O.W. locations and widths. (All existing and proposed R.O.W.'s
sufficient to meet Thoroughfare Plan.)
X N/A Street offsets and/or intersection angles meet ordinance.
N/A N/A Alleys.
X X Easements.
X X A number or letter to identify each lot or site and each block.
N/A N/A Greenbelt area/park linkages/parkland dedication ( All proposed dedications must be
reviewed by the Parks and Recreation Board prior to P & Z Commission consideration.)
X 15. Construction documents for all public infrastructure drawn on 24" x 36° sheets and properly
sealed by a Licensed Texas Professional Engineer that include the following:
N/A Street, alley and sidewalk plans, profiles and sections. One sheet must show the overall
street, alley and/or sidewalk layout of the subdivision. (may be combined with other utilities).
X Sanitary sewer plan and profile showing depth and grades. One sheet must show the
overall sewer layout of the subdivision. (Utilities of sufficient size/depth to meet the utility
master plan and any future growth areas.)
N/A Water line plan showing fire hydrants, valves, etc. with plan and profile lines showing depth
and grades. One sheet must show the overall water layout of the subdivision. (Utilities of
sufficient size/depth to meet the utility master plan and any future growth areas.)
N/A Storm drainage system plan with contours, street profile, inlets, storm sewer and drainage
channels, with profiles and sections. Drainage and runoff areas, and runoff based on 5, 10,
25, 50 and 100 year rain intensity. Detailed drainage structure design, channel lining
design & detention if used. One sheet must show the overall drainage layout of the
subdivision.
X Detailed cost estimates for all public infrastructure listed above sealed by Texas P.E.
N/A Drainage Report.
NIA Erosion Control Plan (must be included in construction plans).
X 16. All off-site easements necessary for infrastructure construction must be shown on the final plat
with a volume and page listed to indicate where the separate instrument easements were filed.
Separate instrument easements must be filed prior or concurrently with Final Plat.
❑ 17. Are there impact fees associated with this development? Yes No
Impact fees for R-1, R-2, & R-3 zoned final plats, must be paid prior to filing.
❑ 18. Will any construction occur in TexDOT rights-of-way? Yes No
If yes, TexDOT permit must be submitted along with the construction documents.
NOTE:
We will be requesting the corrected Final Plat to be submitted in digital form if available prior to
filing the plat at the Courthouse.
2. If the construction area is greater than 5 acres, EPA Notice of Intent (NOI) must be submitted
prior to issuance of a development permit.