Loading...
HomeMy WebLinkAbout02-00500101- 00073273CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone (979) 764 -3570 / Fax (979) 764 -3496 MEMORANDUM TO: Dave Smith via fax 713.934.8772 FROM: Bridgette George, Assistant Development Manager SUBJECT: EASTERWOOD- KINMAN WTF- Conditional Use Permit Site Plan Staff reviewed the above - mentioned site plan as requested and determined that the application is incomplete. The following pages include staff review comments detailing items that need to be addressed. Please address the comments and submit the necessary information by an established deadline date to be scheduled for the next available Planning and Zoning Commission meeting. If you have any questions or need additional information, please call me at 764 -3570. Attachments: Staff review comments cc: Gerald & Joyce Kinman, 1902 Lakeview Drive, Rockwall, TX 75087 -5111 Dave Ballard, Via fax (713) 690 -5037 Mark Brown, Verizon Wireless, Via fax (713) 818 -8093 Case file #02 -101 HOME OF TEXAS A &M UNIVERSITY CITY OF COLLEGE STATION DEVELOPMENT SERVICES 1101 Texas Avenue South, PO Box 9960 College Station, Texas 77842 Phone (979) 764 -3570 / Fax (979) 764 -3496 MEMORANDUM June 25, 2002 TO: File FROM: Molly Hitchcock, Staff Planner SUBJECT: EASTERWOOD- KINMAN WTF- Conditional Use Permit Site Plan I spoke with Dave Smith and Wanda from General Dynamics this afternoon and told them the case would not be accepted because the proposed tower does not meet the ordinance requirement for tower separation. The proposed tower is less than 1000 ft. from an existing tower in the county. They have commented that they will send stealth options to staff to consider before they continue with the CUP. They have been told they will not be on the July 18 P &Z meeting. HOME OF TEXAS A &M UNIVERSITY STAFF REVIEW COMMENTS NO. 1 Project: EASTERWOOD - KINMAN WTF (CUP)- USE & SITE (02 -101) Staff has stopped review of this project. The application submittal is incomplete without the following items: • A WTF facility plan drawing that identifies the location, height, and type of all existing applicant -owned wireless telecommunication facilities in Brazos County including the proposed facility. • Three collocation alternatives to the applicant's development proposal along with proof of a genuine effort in collocating on or attaching to an existing support structure OR evidence that demonstrates that no existing tower or support structure can accommodate the applicant's proposed WTF as described in Section 8.20 of the Zoning Ordinance. • A visual impact analysis as described in Section 8.20 of the Zoning Ordinance. • Certification of compliance with FCC regulations and emission standards. • A letter addressed to the City declaring an intent and willingness to construct a proposed tower that would allow at least two other service providers to locate there. • Notification of an impending environmental assessment required by NEPA and a copy when the assessment is completed. The following comments do not constitute a full review, but are items staff has addressed at this point. A full review will be made of the next submittal. PLANNING 1. This site will require fire protection. Please show the necessary hydrant, fire lanes, etc. 2. New utilities must be placed underground. On sheet C1, please confirm that the new service will be in compliance. 3. On sheet T1, please identify the City of College Station as the jurisdiction. 4. The present zoning of the property is A -O Agricultural Open. Please correct this on the application. 5. On sheet C1, please show the current zoning of the subject parcel and the ownership and current zoning of all abutting parcels. 6. Please include a north arrow on the vicinity map on sheet T1. 7. Please call out the tower's distance to a residential structure on sheet C1. If there is not a residential structure close to the site, please call out a minimum distance (e.g., at least 1000 ft. away). 8. On T1, please identify the distance of the proposed tower to the nearest existing tower. 9. Please provide a fence and gate of solid screening material (e.g., wood). 10. Please take note: If the tract plats, staff will have to further investigate the dedication of rights of way as described on the survey. 11. Sanitation is OK with this project. Reviewed by: Molly Hitchcock Date: May 13, 2002 NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out to the City, will constitute a completely new review. Page 2 of 3 ENGINEERING 1. Engineering will review the proposal once a complete submittal is received. Reviewed by: Natalie Ruiz Date: May 16, 2002 ELECTRICAL 1. Developer installs conduit per city specs and design. 2. Developer provides 30' of #4 rigid conduit for riser poles. Developer installs first 10'. City installs remainder. 3. Developer pours transformer pad(s) per city specs and design. 4. Developer installs pull boxes as per city specs and design.(pull boxes provided by the city). 5. Developer provides digital AutoCAD 2000i version of plat and /or site plan. email to rbolin(cDci.college- station.tx.us 6. Developer provides load data for project. 7. Developer provides temporary blanket easement for construction purposes. 8. Developer provides easements for electric infrastructure as installed for electric lines (including street lights). Reviewed by: Ronnie Bolin Date:5 -14 -02