Loading...
HomeMy WebLinkAboutApplication CASE NFOOR OFFIC7S0E gNLY DATE SUBMITTED 41q CITY Or COLLLGL STATION TIME Home ofTAexasIA University STAFF FINAL PLAT APPLICATION Check one Minor Amending X Final Vacating Replat 50000 50000 60f60i8 60608 60608 Is this plat in the ETJ Yes X No Is this plat Commercial or ResidentialX MINIMUM SUBMITTAL REQUIREMENTS X 560608 Final Plat Application Fee see above 1W I uIlAF 167 Variance Request to Subdivision Regulations Fee if applicable X 600 minimum Development Permit Application Public Infrastructure Review and Inspection Fee Fee is 705 of acceptable Esngineer Estimate for public infrastructure 600 minimum if fee is 600 the balance is due prior to the issuance of any plans or development permit 0 Application completed in full This application form provided by the City of College Station must be used and may not be adjusted or altered Please attach pages if additional information is provided 0 Fourteen 14 folded copies of plat A signed mylar original must be submitted after approval X Two 2 copies of the grading drainage and erosion control plans with supporting drainage report X Two 2 copies of the Public infrastructure plans and supporting documents if applicable X Notice of Intent NOI if disturbed area is greater than five 5 acres cumulatively Q Copy of original deed rceosvtericntaionn tss for replats if applicable X Title report for property current within ninety 90 days or accompanied by a Nothing Further Certificate current within ninety 90 days The report must include applicable information such as ownership liens encumbrances etc 0 Paid tax certificates from City of College Station Brazos County and College StationISD Proof of parkland dedication consideration by the Parks Recreation Board or Parks Recreation Department if applicable 0 The attached Final Plat checklist with all items checked off or a brief explanation as to why they are not NOTE A mylar of the approved preliminary plat must be on file before a final plat application will be considered complete If the mylar is submitted with the final plat plat application it shall be considered a submittal for the preliminary plat project and processed and reviewed as such Until the mylar has been confirmed by staff to be correct the final plat application will be considered incomplete Date of Optional Preapplication or Stormwater Management Conference NAME OF PROJECT Emerald Ridge Estates Phase 1 ADDRESS Eastern end of Emerald Parkway adjacent to Emerald Forest Phase Vll SPECIFIED LOCATION OF PROPOSED PLAT Eastern end of Emerald Parkway adjacent to Emerald Forest Phase Vll APPRPOLIJCEACNTT MSANAGER INFORMATION Primary contact for the project Name Sam Vernon PE mEail scvernono@bleylemngineering Street Address 1722 Broadmoor Dr Ste 210 City Bryan State Tx Zip Code 77802 Phone Number 979 1216285 Fax Number 979 3286409 0109 Page 1 of 7 PROPERTY OSWNER jIANTFIOON ALL owners must be identified crase attach an additional sheet for multiple owners Name Emerald Ridge Estates LTD mEail Pcaull@obrazmostrace Street Address 1722 Broadmoor Dr Ste 212 City Bryan State Tx Zip Code 77802 Phone Number 979 2797040 Fax Number 979 2797949 ARCHITECT OR ESNGINEER INFORMATION Name Sam Vernon PE mEail secevnegorinneoymenr@inbg Street Address 1722 Broadmoor Dr Ste 210 City Bryan State Tx Zip Code 77802 Phone Number 979 1216285 Fax Number 979 3286409 Do any deed restrictions or covenants exist for this property Yes No X Is there a temporary blanket easement on this property If so please provide the Volume 8305 and Page No 22294 Total Acreage 236 Total No of Lots 21 RWOAcreage an Existing Use Agriculture Proposed Use Single Family Residential Number of Lots By Zoning District 21 R1 Average Acreage Of Each Residential Lot By Zoning District 982 R1 Floodplain Acreage 0176 acwno acreage within lots Is there Special Flood Hazard Area Zone A or Zone AE on FEMA FIRM panels on the property FX Yes F No A statement addressing any differences between the Final Plat and Preliminary Plat if applicable Only Phase 1 of Emerald Ridge Estates is being platted as opposed to all phases as was shown on the Preliminary Plat Requested variance to subdivision regulations and reason for same if applicable o additional variances are requested with this application Regarding the variance request explain how 1 There are special circumstances or conditions affecting the land involved such that strict application of the subdivision regulations will deprive the applicant of the reasonable use of his land NA2 The waiver is necessary for the preservation and enjoyment of a substantial property right of the applicant NA 0109 Page 2 of 7 3 The granting of the w6aiv will not be detrimental to the public healtrj safety or welfare or injurious to other property in the area or to the City in administering subdivision regulations A 4 The granting of the waiver will not be detrimental to the public health safety or welfare or injurious to other property in the area or to the City in administering subdivision regulations A Requested Oversize ParticipationNo oversized participation a development agreement has been approved by Council Total Linear Footage of Parkland Dedication due prior to filing the Final Plat Proposed Public 266 Streets ACREAGE 242 Sidewalks 0 No of acres to be dedicated 42492 development fee 2750 Sanitary Sewer Lines 0 No of acres in floodplain 1705 Water Lines 0 No of acres in detention 190 Channels 0 No of acres in greenways 0 Storm Sewers OR 0 Bike Lanes Paths FEE IN LIEU OF LAND 21 No of SF Dwelling Units X 619 91929 912112009 date Approved by Parks Recreation Advisory Board NOTE DIGITAL COPY OF PLAT MUST BE SUBMITTED PRIOR TO FILING The applicant has prepared this application and certifies that the facts stated herein and exhibits attached hereto are true correct and complete IF THIS APPLICATION IS FILED BY ANYONE OTHER THAN THE OWNER OF THE PROPERTY this application must be accompanied by a power of attorney statement from the owner If there is more than one owner all owners must sign the application or the power of attorney If the owner is a company the application must be accompanied by proof of authority for the csompany representative to sign the application on its behalf LIEN HOLDERS identified in the title report are also considered owners and the appropriate signatures must be provided as described above Signature and t e Date 0109 Page 3 of 7 GENERAL PROVISIONS FOR DEVELOPMENT PERMIT 1 No work of any kind may start until a permit is issued 2 The permit may be revoked if any false statements are made herein 3 If revoked all work must cease until permit is irsseued 4 Development shall not be used or occupied until a Certificate of Occupancy is issued 5 The permit will expire if no work is commenced within 24 months of issuance 6 Arepqpuliicreamntenists hereby informed that other permits may be required to fulfill local state and federal regulator 7 Acopmplpiclaianntcehereby gives consent to the City representatives to make reasonable inspections required to verify 8 In accordance with Chapter 13 of the Code of Ordinances of the City of College Station measures shall be taken to dinrsauinreagtehaftacdielibtireiss froAmll cdoenvestlorupcmtieonnt esrhoaslliobne ainndascecdoirmdaennctaetiownithshtahlel npolat nbse adnedposspiteecdificinatcioitnysstsruebemtsitteord etxoisatinngd approved by the City Engineer for the above named project All of the applicable codes and ordinances of the City of College Station shall apply 9APERPPLICATION R CERTIFY T TALL STATEMENTS HEREIN AND IN ATTACHMENTS FOR THE DEVELOPMENT A TO E BEST OF MY KNOWLEDGE TRUE AND ACCURATE 3 rs Date ACKNOWLEDGMENTS required for all development 1 rcIa ESLTD the owner hereby acknowledge or affirm that The information and conclusions contained in the above plans and supporting documents comply with the current requirements of the City of College Station Texas City Code Chapter 13 and associated BCS Unified Design Guidelines All development has been designed in accordance with all applicable codes and ordi f the City of Co ge n and State and Federal Regulations Property Owner 3y iS3c4Za Tfuc c LL s Grecrc Date 13 PLw tLikeCovs 2 IFrcal SRc eS LT O certify that all necessary State and Federal permits will be obtained prior to cons ction SLI 3o o Property Oswner 3fw os jr4Ge LC its GevwA Pdwcr Date Uy PL tNve w4 iS lit Si ewe 3 ILQAWjra j99e FaSLTD the Owner authorize release of plans toal SCS1n SOGI for bidding purposes only I understand that final approval and release of plans for construction is contingent on contractor signature on approved Development Permit 3 10 Property OLswner odCUscTrauc s GkOW MIMS Date P L S w 0109 Page 4 of 7 ENGINEERING CERTIFICATIONS required for development in Special Flood Hazard Areas A I certify that any nonresidential structure on or proposed to be on this site as part of this application is designated to prevent damage to the structure or its contents as a result of flooding from the y1e0a0r storm Engineer Date B 1 certify that the finished floor elevation of the lowest floor including any basement of any residential structure proposed as part of this application is at or above the base flood elevation established in the latest Federal Insurance Administration Flood Hazard Study and map as amended Engineer Date C 1 Syh T VeNw certify that the alterations or development covered by this permit shall not diminish the fclaorryoindg capacity of the waterway adjoining or crossing this permitted site and that such alterations or development are consistent with requirements of the City of College Station City Code Chapter 13 on rning encroa hments of floodways and of floodway fringesmil eboic gineer U Date D 1 SxM T V oJ certify that the proposed alterations do not raise the level of the y1e0a0r flood above elevation established in the latest Federal Insurance Administration Flood Hazard Study QA 4 t114 t3oIZola Engineer Date Conditions or comments as part of approval 0109 Page 5 of 7